首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   241篇
  免费   56篇
  国内免费   2篇
  2024年   4篇
  2023年   9篇
  2022年   16篇
  2021年   8篇
  2020年   21篇
  2019年   28篇
  2018年   24篇
  2017年   25篇
  2016年   24篇
  2015年   12篇
  2014年   29篇
  2013年   39篇
  2012年   3篇
  2011年   16篇
  2010年   1篇
  2009年   6篇
  2008年   4篇
  2007年   3篇
  2006年   2篇
  2005年   2篇
  2004年   3篇
  2003年   2篇
  2002年   4篇
  2001年   2篇
  2000年   3篇
  1999年   1篇
  1998年   4篇
  1997年   2篇
  1996年   2篇
排序方式: 共有299条查询结果,搜索用时 15 毫秒
291.
The application of 3D printing patient specific instrumentation model in total knee arthroplasty was explored to improve the operative accuracy and safety of artificial total knee arthroplasty. In this study, a total of 52 patients who need knee replacement were selected as the study objects, and 52 patients were divided into experimental group and control group. First, the femoral mechanical-anatomical angle (FMAA), lateral femoral angle (LFA), hip-knee-ankle angle (HKA), femorotibial angle (FTA) of research objects in both groups were measured. Then, the blood loss during the operations, drainage volume after operations, total blood loss, hidden blood loss, and hemoglobin decrease of the experiment group and the control group were measured and calculated. Finally, the postoperative outcomes of patients who underwent total knee arthroplasty were evaluated. The results showed that before the operations, in the PSI group, the femoral mechanical-anatomical angle (FMAA) was (6.9 ± 2.4)°, the lateral femoral angle (LFA) was (82.4 ± 1.6)°, the hip-knee-ankle angle (HKA) was (166.4 ± 1.4)°, and the femorotibial angle (FTA) was (179.5 ± 7.3)°. In the CON group, the FMAA was (5.8 ± 2.4)°, the LFA was (81.3 ± 2.1)°, the HKA was (169.5 ± 1.9)°, and the FTA was (185.4 ± 5.4)°. The differences in these data between the two groups were not statistically significant (P > 0.05). After the operations, in the PSI group, the total blood loss, the hidden blood loss, and the hemoglobin (Hb) decrease were respectively (420.2 ± 210.5), (240.5 ± 234.5), and (1.7 ± 0.9); in the CON group, the total blood loss, the hidden blood loss, and the Hb decrease were respectively (782.1 ± 340.4), (450.9 ± 352.6), and (2.9 ± 1.0). These data of both groups were statistically significant (P < 0.05). Therefore, it can be seen that the 3D printing patient specific instrumentation model can effectively simulate the lower limb coronal force line and was highly consistent of the preoperative software simulation plan. In addition, the random interviews of patients who underwent total knee arthroplasty showed that the knees of patients had recovered well. The application of 3D printing patient specific instrumentation model in artificial total knee arthroplasty can effectively improve the operative accuracy and safety, and the clinical therapeutic effects were significant.  相似文献   
292.
A multitude of morphological aspects of the human middle ear (ME) were studied qualitatively and/or quantitatively through the postprocessing and interpretation of micro‐CT (micro X‐ray computed tomography) data of six human temporal bones. The samples were scanned after phosphotungstic acid staining to enhance soft‐tissue contrast. The influence of this staining on ME ossicle configuration was shown to be insignificant. Through postprocessing, the image data were converted into surface models, after which the approaches diverged depending on the topics of interest. The studied topics were: the ME ligaments; morphometric and mechanical parameters of the ossicles relating to inertia and the ossicular lever arm ratio; the morphology of the distal incus; the contact surface areas of the tympanic membrane (TM) and of the stapes footplate; and the thickness of the TM, round window of the cochlea, ossicle joint spaces, and stapedial annular ligament. Some of the resulting insights are relevant in ongoing discussions concerning ME morphology and mechanical functions, while other results provide quantitative data to add to existing data. All findings are discussed in the light of other published data and many are relevant for the construction of mechanical finite element simulations of the ME. J. Morphol. 276:1025–1046, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   
293.
膝骨关节炎(knee osteoarthritis,KOA)是以关节软骨退变为主要病变的退行性疾病。目前,KOA尚无有效治疗药物。细胞外囊泡(extracellular vesicles,EVs)是由细胞释放的脂质双分子层包绕形成的球状膜性囊泡,可在细胞间传递核酸、蛋白质等生物活性分子。与动物来源EVs相比,植物来源EVs因其来源广泛且经济,在药物载体递送研究领域引起广泛关注。通过基因工程等方法改造EVs进行药物递送,可极大提高药物递送效率及其疗效。本文综述了动、植物两种来源的EVs在KOA中的治疗进展,特别聚焦于工程化EVs作为药物递送载体在KOA治疗中的研发现状,旨在为利用EVs治疗KOA提供参考。  相似文献   
294.
骨关节炎是一种涉及所有关节成分(包括关节软骨、软骨下骨、滑膜、韧带、关节囊和关节周围肌肉)的关节退行性疾病,会导致严重的残疾,其中最常见的是膝骨关节炎(knee osteoarthritis,KOA)。外泌体是一种由不同细胞分泌的直径为40~100 nm的胞外囊泡,可以传递DNA、微小RNA、mRNA、蛋白质等多种物质,并通过多种方式进行细胞间的信息传递和功能调节。间充质干细胞(mesenchymal stem cells,MSCs)可以从骨髓、脂肪、滑膜及外周血等组织分离,是一类具有多向分化潜能的祖细胞,以干细胞为基础的疗法可以修复软骨损伤,对抗KOA的发展,间充质干细胞能够分泌多种营养因子来调节受损的微环境,其中间充质干细胞来源的外泌体被认为在KOA炎症反应及软骨细胞代谢中发挥着重要的作用,其能够调节膝骨关节微环境中B细胞、T细胞、滑膜细胞、软骨细胞代谢及其细胞外基质的分解与合成平衡,维持软骨稳态。近期有多项研究表明,不同组织来源的间充质干细胞外泌体对骨关节炎均有明确的治疗作用,本文就MSCs来源的外泌体治疗KOA的具体机制进行综述,以期对干细胞治疗KOA提供理论依据。  相似文献   
295.
Prominent conservative treatment options for medial-compartment knee osteoarthritis include footwear that reduces knee adduction moment (KAM) correlated with detrimental loads in the medial compartment of the knee, thus providing clinical benefit. The proposed mechanism by which they reduce KAM is a lateral shift in foot center of pressure (COP) and a consequent shortening of the knee lever arm (KLA), thereby reducing KAM, which can be simply calculated as KLA multiplied by the frontal plane ground reaction force (FP-GRF). The present study investigated this mechanism for a unique biomechanical device capable of shifting COP by means of moveable convex elements attached to the shoe. Fourteen healthy young male subjects underwent gait analysis in two COP configurations of the device for comparison: (1) laterally and (2) medially deviated. Average midstance KLA and KAM were decreased by 8.2% and 8.7%, respectively, in the lateral COP compared to medial. Ground reaction force parameters, frontal plane knee angle (FP-KA), and spine lateral flexion angle (SLF) did not differ between COP configurations. No study parameters differed for terminal stance. Linear mixed effects models showed that COP and FP-GRF components, but not FP-KA and SLF, were significant predictors of KLA. In addition, KLA and FP-GRF were significant predictors of KAM; although, FP-GRF did not change significantly with medio-lateral COP shift, while KLA did. This suggests that the mechanism by which the study device reduces KAM is primarily through shortening of KLA brought on by a lateral shift in COP.  相似文献   
296.
297.
Misalignment and soft-tissue imbalance in total knee arthroplasty (TKA) can cause discomfort, pain, inadequate motion and instability that may require revision surgery. Balancing can be defined as equal collateral ligament tensions or equal medial and lateral compartmental forces during the flexion range. Our goal was to study the effects on balancing of linear femoral component misplacements (proximal, distal, anterior, posterior); and different component rotations in mechanical alignment compared to kinematic alignment throughout the flexion path. A test rig was constructed such that the position of a standard femoral component could be adjusted to simulate the linear and rotational positions. With the knee in neutral reference values of the collateral tensions were adjusted to give anatomic contact force patterns, measured with an instrumented tibial trial. The deviations in the forces for each femoral component position were then determined. Compartmental forces were significantly influenced by 2 mm linear errors in the femoral component placement. However, the errors were least for a distal error, equivalent to undercutting the distal femur. The largest errors mainly increase the lateral condyle force, occurred for proximal and posterior component errors. There were only small contact force differences between kinematic and mechanical alignment. Based on these results, surgeons should avoid overcutting the distal femur and undercutting the posterior femur. However, the 2–3 degrees varus slope of the joint line as in kinematic alignment did not have much effect on balancing, so mechanical or kinematic alignment were equivalent.  相似文献   
298.
Unbalanced contact force on the tibial component has been considered a factor leading to loosening of the implant and increased wear of the bearing surface in total knee arthroplasty. Because it has been reported that good alignment cannot guarantee successful clinical outcomes, the soft tissue balance should be checked together with the alignment. Finite element models of patients' lower extremities were developed to analyse the medial and lateral contact force distribution on the tibial insert. The distributions for four out of five patients were not balanced equally, even though the alignment angles were within a clinically acceptable range. Moreover, the distribution was improved by changing soft tissue release and ligament tightening for the specific case. Integration of the biomechanical modelling, image matching and finite element analysis techniques with the patient-specific properties and various dynamic loading would suggest a clinically relevant pre-operative planning for soft tissue balancing.  相似文献   
299.
Persistent changes in joint biomechanics resulting from knee injury are thought to contribute to progressive cartilage damage and post-traumatic osteoarthritis (PTOA). The identification and quantification of in vivo tibiofemoral surface interactions are critical to understanding them, particularly abnormal interactions that are damaging to articular cartilage and other structures of the knee. In this study, we describe an approach for understanding such potential interactions by using a weighted centroid derived from in vivo stifle kinematics in sheep. Collectively, repeatability and sensitivity analyses indicate that the magnitude of the changes in tibiofemoral centroid location resulting from combined ligament transection is greater than the repeatability and precision of the current weighted centroid approach, making this method useful for describing the changes in dynamic surface interactions that may be relevant in the pathogenesis of PTOA in this stifle injury model.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号