首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   170篇
  免费   32篇
  国内免费   1篇
  2024年   1篇
  2023年   5篇
  2022年   7篇
  2021年   17篇
  2020年   14篇
  2019年   25篇
  2018年   11篇
  2017年   14篇
  2016年   8篇
  2015年   11篇
  2014年   22篇
  2013年   32篇
  2012年   8篇
  2011年   5篇
  2010年   1篇
  2009年   3篇
  2008年   5篇
  2007年   1篇
  2006年   1篇
  2005年   3篇
  2004年   2篇
  1999年   1篇
  1994年   1篇
  1993年   1篇
  1992年   1篇
  1986年   2篇
  1983年   1篇
排序方式: 共有203条查询结果,搜索用时 15 毫秒
81.
BackgroundIntraluminal thrombus (ILT) formation plays a significant role in the progression of infrarenal abdominal aortic aneurysms (AAA). Potentially, as ILT thickness increases the availability of trace elements in the aneurysm wall could decrease thereby leading to oxidative stress and intensifying pro-inflammatory cytokine generation.AimTo determine if thrombus thickness is related to the concentration of trace elements in the wall of infrarenal AAA.Patients and methodsThe concentrations of trace elements in the wall of the aneurysm sack and ILT obtained from 19 consecutive patients during surgery for infrarenal AAA were determined using emission spectrometry.ResultsThe concentrations of magnesium, zinc, manganese, and lead in the wall of AAA were significantly greater than in the ILT. Only the concentration of copper was lower in the AAA wall compared with the thrombus. The concentration of calcium, phosphorus, zinc, lead, copper, and magnesium increased with ILT thickness. The concentrations of no other trace elements in the wall of AAA were found to be related to the ILT thickness.ConclusionsIntraluminal thrombus thickness is not associated with a lower concentration of trace elements in the wall of the infrarenal AAA. Thus, the intraluminal thrombus participates in the progression of AAA by mechanisms independent of trace element supply to the wall of the aneurysm sack.  相似文献   
82.
《Journal of biomechanics》2014,47(16):3882-3890
Due to the lack of patient-specific inlet flow waveform measurements, most computational fluid dynamics (CFD) simulations of intracranial aneurysms usually employ waveforms that are not patient-specific as inlet boundary conditions for the computational model. The current study examined how this assumption affects the predicted hemodynamics in patient-specific aneurysm geometries. We examined wall shear stress (WSS) and oscillatory shear index (OSI), the two most widely studied hemodynamic quantities that have been shown to predict aneurysm rupture, as well as maximal WSS (MWSS), energy loss (EL) and pressure loss coefficient (PLc). Sixteen pulsatile CFD simulations were carried out on four typical saccular aneurysms using 4 different waveforms and an identical inflow rate as inlet boundary conditions. Our results demonstrated that under the same mean inflow rate, different waveforms produced almost identical WSS distributions and WSS magnitudes, similar OSI distributions but drastically different OSI magnitudes. The OSI magnitude is correlated with the pulsatility index of the waveform. Furthermore, there is a linear relationship between aneurysm-averaged OSI values calculated from one waveform and those calculated from another waveform. In addition, different waveforms produced similar MWSS, EL and PLc in each aneurysm. In conclusion, inlet waveform has minimal effects on WSS, OSI distribution, MWSS, EL and PLc and a strong effect on OSI magnitude, but aneurysm-averaged OSI from different waveforms has a strong linear correlation with each other across different aneurysms, indicating that for the same aneurysm cohort, different waveforms can consistently stratify (rank) OSI of aneurysms.  相似文献   
83.
《Journal of biomechanics》2014,47(14):3524-3530
To investigate the hemodynamic performance of overlapping bare-metal stents intervention treatment to thoracic aortic aneurysms (TAA), three simplified TAA models, representing, no stent, with a single stent and 2 overlapped stents deployed in the aneurismal sac, were studied and compared in terms of flow velocity, wall shear stress (WSS) and pressure distributions by means of computational fluid dynamics. The results showed that overlapping stents intervention induced a flow field of slow velocity near the aneurismal wall. Single stent deployment in the sac reduced the jet-like flow formed prior to the proximal neck of the aneurysm, which impinged on the internal wall of the aneurysm. This jet-like flow vanished completely in the overlapping double stents case. Overlapping stents intervention led to an evident decrease in WSS; meanwhile, the pressure acting on the wall of the aneurysm was reduced slightly and presented more uniform distribution. The results therefore indicated that overlapping stents intervention may effectively isolate the thoracic aortic aneurysm, protecting it from rupture. In conclusion, overlapping bare-metal stents may serve a purpose similar to that of the multilayer aneurysm repair system (MARS) manufactured by Cardiatis SA (Isnes, Belgium).  相似文献   
84.
The aim of this work is to develop a unique in vitro set-up in order to analyse the influence of the shear thinning fluid-properties on the flow dynamics within the bulge of an abdominal aortic aneurysm (AAA). From an experimental point of view, the goals are to elaborate an analogue shear thinning fluid mimicking the macroscopic blood behaviour, to characterise its rheology at low shear rates and to propose an experimental device able to manage such an analogue fluid without altering its feature while reproducing physiological flow rate and pressure, through compliant AAA. Once these experimental prerequisites achieved, the results obtained in the present work show that the flow dynamics is highly dependent on the fluid rheology. The main results point out that the propagation of the vortex ring, generated in the AAA bulge, is slower for shear thinning fluids inducing a smaller travelled distance by the vortex ring so that it never impacts the anterior wall in the distal region, in opposition to Newtonian fluids. Moreover, scalar shear rate values are globally lower for shear thinning fluids inducing higher maximum stress values than those for the Newtonian fluids. Consequently, this work highlights that a Newtonian fluid model is finally inadequate to obtain a reliable prediction of the flow dynamics within AAA.  相似文献   
85.
The regional distribution of wall thickness and failure properties in human abdominal aortic aneurysm (AAA) was explored. Three unruptured and one ruptured AAA were harvested as a whole during necropsy. Thickness was measured at about every 1.5 cm2 wall surface area for an average of 100 measurement sites per AAA. Multiple longitudinally oriented rectangular specimen strips were cut at various locations from each AAA for a total of 48 strips. The strips were subjected to uniaxial extension until failure. Wall thickness varied regionally and between AAA from as low as 0.23 mm at a rupture site to 4.26 mm at a calcified site (median=1.48 mm). Wall thickness was slightly lower in the posterior and right regions. The failure tension (ultimate) of specimen strips varied regionally and between AAA from 5.5 N/cm close to a blister site in the ruptured AAA to 42.3 N/cm at the undilated neck of a 4 cm diameter unruptured AAA (median=14.8 N/cm). Failure stress (ultimate) varied from 33.6 to 235.1 N/cm2 (median=126.6 N/cm2). There was no perceptible pattern in failure properties along the circumference. Failure tension of specimen strips at or close to blisters was mostly low. The rupture site in the ruptured aneurysm had the lowest recorded wall thickness of 0.23 mm with only slightly higher readings within a 1 cm radius. The failure tension of the specimen strip close to the rupture site was low (11.1 N/cm) compared to its neighborhood in the ruptured aneurysm.  相似文献   
86.
目的:探讨瑞芬太尼联合异丙酚对全麻下颅内动脉瘤夹闭术患者麻醉效果及血清中枢神经特异蛋白(S100β)、神经元特异性烯醇化酶(NSE)的影响。方法:选取2017年2月~2019年1月期间于我院行全麻下颅内动脉瘤夹闭术的患者103例,根据随机数字表法将患者分为对照组(n=51)和研究组(n=52),对照组给予异氟醚联合异丙酚麻醉,研究组给予瑞芬太尼联合异丙酚麻醉,比较两组患者麻醉效果、再出血率及血清S100β、NSE水平。结果:研究组硬脑膜切开前(T2)~动脉瘤夹闭即刻(T4)时间点心率(HR)、中心静脉压(MAP)均低于对照组(P0.05)。研究组自主呼吸恢复时间、定向力恢复时间、呼吸后睁眼时间、气管拔管时间、离开手术室时间均短于对照组(P0.05)。研究组T2~手术结束时(T5)时间点血清S100β、NSE水平低于对照组(P0.05)。两组再出血率比较差异无统计学意义(P0.05)。结论:瑞芬太尼联合异丙酚可改善全麻下颅内动脉瘤夹闭术患者的术后指标,维持血流动力学平稳,减轻脑损害。  相似文献   
87.
Cerebral aneurysm is an irreversible dilatation causing intracranial haemorrhage with severe complications. It is assumed that the biomechanical factor plays a significant role in the development of cerebral aneurysm. However, reports on the correlations between the formation of intraluminal thrombus and the flow pattern, wall shear stress (WSS) distribution of the cerebral aneurysm as well as wall compliance are still limited. In this research, patient-specific numerical simulation was carried out for three cerebral aneurysms based on magnetic resonance imaging (MRI) data-sets. The interaction between pulsatile blood and aneurysm wall was taken into account. The biomechanical behaviour of cerebral aneurysm and its relation with the formation of intraluminal thrombus was studied systematically. The results of the numerical simulation indicated that the region of low blood flow velocity and the region of swirling recirculation were nearly coincident with each other. Besides, there was a significant correlation between the slow swirling flow and the location of thrombus deposition. Excessively low WSS was also found to have strong association with the regions of thrombus formation. Moreover, the relationship between cerebral aneurysm compliance and thrombus deposition was discovered. The patient-specific modelling study based on fluid–structure interaction) may provide a basis for future investigation on the prediction of thrombus formation in cerebral aneurysm.  相似文献   
88.
Endovascular aneurysm exclusion is a validated technique to prevent aneurysm rupture. Long-term results highlight technique limitations and new aspects of Abdominal aortic aneurysm (AAA) pathophysiology. There is no abdominal aortic aneurysm endograft exclusion model cheap and reproducible, which would allow deep investigations of AAA before and after treatment. We hereby describe how to induce, and then to exclude with a covered coronary stentgraft an abdominal aortic aneurysm in a rat. The well known elastase induced AAA model was first reported in 19901 in a rat, then described in mice2. Elastin degradation leads to dilation of the aorta with inflammatory infiltration of the abdominal wall and intra luminal thrombus, matching with human AAA. Endovascular exclusion with small covered stentgraft is then performed, excluding any interactions between circulating blood and the aneurysm thrombus. Appropriate exclusion and stentgraft patency is confirmed before euthanasia by an angiography thought the left carotid artery. Partial control of elastase diffusion makes aneurysm shape different for each animal. It is difficult to create an aneurysm, which will allow an appropriate length of aorta below the aneurysm for an easy stentgraft introduction, and with adequate proximal and distal neck to prevent endoleaks. Lots of failure can result to stentgraft introduction which sometimes lead to aorta tear with pain and troubles to stitch it, and endothelial damage with post op aorta thrombosis. Giving aspirin to rats before stentgraft implantation decreases failure rate without major hemorrhage. Clamping time activates neutrophils, endothelium and platelets, and may interfere with biological analysis.  相似文献   
89.
目的:探究球囊辅助栓塞技术治疗未破裂颅内动脉瘤的有效性和安全性。方法:选择2014年1月~2019年1月在本院介入诊疗科接受介入治疗的540例患者作为研究对象。根据治疗方案分为两组,球囊辅助栓塞组有340例,单纯栓塞组有200例。回顾性分析研究对象的一般资料、临床资料、手术并发症等情况。结果:球囊辅助栓塞组和单纯栓塞组在性别组成、年龄、颅内动脉瘤性质、位置、Hunt-Hess分级等方面,差异不具有统计学意义(P>0.05);在术后即刻及术后6个月血管造影结果显示,前者栓塞程度明显优于后者,两组差异具有统计学意义(P<0.05);前者改良Rankin量表评分明显优于后者,两组差异具有统计学意义(P=0.005);前者预后良好率明显高于后者,两组差异具有统计学意义(P<0.001);手术过程中,球囊辅助栓塞组发生2例破裂出血、2例脑血管痉挛、1例弹簧圈移位,单纯栓塞组发生2例破裂出血、1例栓塞、2例脑血管痉挛、3例弹簧圈移位。前者并发症发生率明显低于后者,两者差异具有统计学意义(P<0.001)。结论:在治疗未破裂颅内动脉瘤方面,球囊辅助栓塞技术的有效性、安全性明显优于单纯栓塞介入治疗,值得临床推广。  相似文献   
90.
Mycotic aneurysm of the aorta is an uncommon condition, and Group B Streptococcus (GBS) is exceedingly rare in this setting. We present the first reported case of a GBS-infected abdominal aortic aneurysm (AAA) in North America. Key clinical and imaging findings and pathologic correlation are highlighted. A relevant review of the literature is discussed, which will bring the reader up to date with this specific disease entity.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏