全文获取类型
收费全文 | 146篇 |
免费 | 7篇 |
国内免费 | 1篇 |
专业分类
154篇 |
出版年
2023年 | 3篇 |
2022年 | 2篇 |
2021年 | 11篇 |
2020年 | 14篇 |
2019年 | 10篇 |
2018年 | 7篇 |
2017年 | 9篇 |
2016年 | 11篇 |
2015年 | 8篇 |
2014年 | 15篇 |
2013年 | 11篇 |
2012年 | 6篇 |
2011年 | 3篇 |
2010年 | 5篇 |
2009年 | 1篇 |
2008年 | 7篇 |
2007年 | 2篇 |
2006年 | 5篇 |
2005年 | 1篇 |
2004年 | 2篇 |
2003年 | 6篇 |
2002年 | 2篇 |
2001年 | 2篇 |
1999年 | 1篇 |
1998年 | 1篇 |
1996年 | 2篇 |
1994年 | 2篇 |
1992年 | 1篇 |
1985年 | 3篇 |
1972年 | 1篇 |
排序方式: 共有154条查询结果,搜索用时 11 毫秒
61.
From its inception, EFOMP has pursued a policy to improve and coordinate education and training of medical physicists across all its participating European countries. Several EFOMP policy statements on education and training have been published and surveys have been held to get an overview of the actual situation. At the beginning of 2020 a new survey was distributed amongst the 36 National Member Organizations (NMOs), in which questions were based on recommendations published in the most recent policy statements. Thirty-three of the NMOs (91%) responded, of which 22 indicated having a National Registration Scheme (NRS) for Medical Physics Experts (MPEs) in place. Another 6 indicated considering such a scheme.Results of the questionnaire showed that there was good correspondence between education and training programmes, i.e. a division between a BSc phase, an MSc phase and a clinical phase after completion of the MSc. Differences between NRSs were primarily seen in the availability and composition of a supervising committee and in the availability of guidelines for handling professional misconduct. In addition, some differences were seen in the topics that were part of the education and training programme.The goal of a universal (registered) MPE accepted by all European countries is still far away despite the progress being made. The new procedure for approving an existing NRS, which fulfils all EFOMP criteria is seen as an important step forward. Exchange of experience, knowledge, ideas and, above all, MPE trainees between European countries is seen as the best approach to achieve this goal. 相似文献
62.
Peptide receptor radionuclide therapy (PRRT) is an effective MRT (molecular radiotherapy) treatment, which consists of multiple administrations of a radiopharmaceutical labelled with 177Lu or 90Y. Through sequential functional imaging a patient specific 3D dosimetry can be derived. Multiple scans should be previously co-registered to allow accurate absorbed dose calculations. The purpose of this study is to evaluate the impact of image registration algorithms on 3D absorbed dose calculation.A cohort of patients was extracted from the database of a clinical trial in PRRT. They were administered with a single administration of 177Lu-DOTATOC. All patients underwent 5 SPECT/CT sequential scans at 1 h, 4 h, 24 h, 40 h, 70 h post-injection that were subsequently registered using rigid and deformable algorithms. A similarity index was calculated to compare rigid and deformable registration algorithms. 3D absorbed dose calculation was carried out with the Raydose Monte Carlo code.The similarity analysis demonstrated the superiority of the deformable registrations (p < .001).Average absorbed dose to the kidneys calculated using rigid image registration was consistently lower than the average absorbed dose calculated using the deformable algorithm (90% of cases), with percentage differences in the range [−19; +4]%. Absorbed dose to lesions were also consistently lower (90% of cases) when calculated with rigid image registration with absorbed dose differences in the range [−67.2; 100.7]%. Deformable image registration had a significant role in calculating 3D absorbed dose to organs or lesions with volumes smaller than 100 mL.Image based 3D dosimetry for 177Lu-DOTATOC PRRT is significantly affected by the type of algorithm used to register sequential SPECT/CT scans. 相似文献
63.
Conventional measures of model fit for indexed data (e.g., time series or spatial data) summarize errors in y, for instance by integrating (or summing) the squared difference between predicted and measured values over a range of x. We propose an approach which recognizes that errors can occur in the x-direction as well. Instead of just measuring the difference between the predictions and observations at each site (or time), we first "deform" the predictions, stretching or compressing along the x-direction or directions, so as to improve the agreement between the observations and the deformed predictions. Error is then summarized by (a) the amount of deformation in x, and (b) the remaining difference in y between the data and the deformed predictions (i.e., the residual error in y after the deformation). A parameter, lambda, controls the tradeoff between (a) and (b), so that as lambda-->infinity no deformation is allowed, whereas for lambda=0 the deformation minimizes the errors in y. In some applications, the deformation itself is of interest because it characterizes the (temporal or spatial) structure of the errors. The optimal deformation can be computed by solving a system of nonlinear partial differential equations, or, for a unidimensional index, by using a dynamic programming algorithm. We illustrate the procedure with examples from nonlinear time series and fluid dynamics. 相似文献
64.
65.
Entomopathogenic fungi being developed as biological control agents (BCAs) may have the potential to spread and become established in the environment. For registration purposes, the risks concerning their persistence have to be evaluated according to EU legislation which requires the decline of BCAs to acceptable background levels unless related risks are acceptable. In order to deal with this requirement, applicants of a BCA need to give information on its persistence and natural background levels. For risk assessors and registration authorities guidance on how to evaluate data on natural background levels of indigenously occurring species (=same species as the introduced BCA) is needed. For this purpose, an overview is presented on background levels of some indigenous fungi as well as persistence data of some applied fungal BCAs. Data were restricted to commerical species. It was found that for the species Metarhizium anisopliae, Beauveria bassiana and Beauveria brongniartii natural densities were relatively low and introduced strains of these fungi decreased gradually in time. Many factors were found in the literature, such as intrinsic, edaphic, biotic, climatic, and cultural factors, that could explain this decline. 相似文献
66.
PurposeAn investigation was carried out into the effect of three image registration techniques on the diagnostic image quality of contrast-enhanced magnetic resonance angiography (CE-MRA) images.MethodsWhole-body CE-MRA data from the lower legs of 27 patients recruited onto a study of asymptomatic atherosclerosis were processed using three deformable image registration algorithms. The resultant diagnostic image quality was evaluated qualitatively in a clinical evaluation by four expert observers, and quantitatively by measuring contrast-to-noise ratios and volumes of blood vessels, and assessing the techniques' ability to correct for varying degrees of motion.ResultsThe first registration algorithm (‘AIR’) introduced significant stenosis-mimicking artefacts into the blood vessels' appearance, observed both qualitatively (clinical evaluation) and quantitatively (vessel volume measurements). The two other algorithms (‘Slicer’ and ‘SEMI’), based on the normalised mutual information (NMI) concept and designed specifically to deal with variations in signal intensity as found in contrast-enhanced image data, did not suffer from this serious issue but were rather found to significantly improve the diagnostic image quality both qualitatively and quantitatively, and demonstrated a significantly improved ability to deal with the common problem of patient motion.ConclusionsThis work highlights both the significant benefits to be gained through the use of suitable registration algorithms and the deleterious effects of an inappropriate choice of algorithm for contrast-enhanced MRI data. The maximum benefit was found in the lower legs, where the small arterial vessel diameters and propensity for leg movement during image acquisitions posed considerable problems in making accurate diagnoses from the un-registered images. 相似文献
67.
E. Brännäs 《Journal of fish biology》2014,84(1):133-144
Feeding activity from a larger refuge site into two visually separated feeding sites with temporally restricted food availability, one in the morning and one in the evening was studied in duplicate groups of Arctic charr Salvelinus alpinus. A passive integrated transponder (PIT) system enabled continuous monitoring of individual movements between the sites. Both groups synchronized their diel pattern of visit activity to the two feeding sites when food was available. One group showed significant anticipatory visit activity into both feeding sites during the hours before the feed was available, suggesting a time and place learning of resource availability. The anticipatory activity of the other group was, however, less pronounced and only occurred into one of the feeding sites. Individual S. alpinus entered the feeding sites independently and no obvious patterns of leaders and followers were identified. All S. alpinus gained mass and moved between a refuge and the feeding sites. Different strategies of how individual S. alpinus utilized the feeding sites were not correlated with growth. 相似文献
68.
Background and purposeThe aim was to evaluate dosimetric uncertainties of a mixed beam approach for patients with high-risk prostate cancer (PCa). The treatment consists of a carbon ion radiotherapy (CIRT) boost followed by whole-pelvis intensity-modulated RT (IMRT).Materials and methodsPatients were treated with a CIRT boost of 16.6 Gy/4 fractions followed by whole-pelvis IMRT of 50 Gy/25 fractions, with consequent long term androgen deprivation therapy. Deformable computed tomography image registration (DIR) was performed and corresponding doses were used for plan sum. A comparative IMRT photon plan was obtained as whole-pelvis IMRT of 50 Gy/25 fractions followed by a boost of 28 Gy/14 fractions. DIR performances were evaluated through structure-related and image characteristics parameters.ResultsUntil now, five patients out of ten total enrolled ended the treatment. Dosimetric parameters were lower in CIRT + IMRT than IMRT-only plans for all organs at risk (OARs) except femoral heads.Regarding DIR evaluation, femoral heads were the less deformed OAR. Penile bulb, bladder and anal canal showed intermediate deformation. Rectum was the most deformed. DIR algorithms were patient (P)-dependent, as performances were the highest for P3 and P4, intermediate for P2 and P5, and the lowest for P1.ConclusionsCIRT allows better OARs sparing while increasing the efficacy due to the higher radio-biological effect of carbon ions. However, a mixed beam approach could introduce DIR problems in multi-centric treatments with different operative protocols. The development of this prospective trial will lead to more mature data concerning the clinical impact of implementing DIR procedures in dose accumulation applications for high-risk PCa treatments. 相似文献
69.
In this contribution we describe the implementation of a novel solution for image guided particle therapy, designed to ensure the maximal accuracy in patient setup. The presented system is installed in the central treatment room at Centro Nazionale di Adroterapia Oncologica (CNAO, Italy), featuring two fixed beam lines (horizontal and vertical) for proton and carbon ion therapy. Treatment geometry verification is based on robotic in-room imaging acquisitions, allowing for 2D/3D registration from double planar kV-images or 3D/3D alignment from cone beam image reconstruction. The calculated six degrees-of-freedom correction vector is transferred to the robotic patient positioning system, thus yielding automated setup error compensation. Sub-millimetre scale residual errors were measured in absolute positioning of rigid phantoms, in agreement with optical- and laser-based assessment. Sub-millimetre and sub-degree positioning accuracy was achieved when simulating setup errors with anthropomorphic head, thorax and pelvis phantoms. The in-house design and development allowed a high level of system customization, capable of replicating the clinical performance of commercially available products, as reported with preliminary clinical results in 10 patients. 相似文献
70.
Hiroshi Koyama Kanae Kishi Seiya Mikoshiba Toshihiko Fujimori 《Development, growth & differentiation》2023,65(1):65-74
Three-dimensional (3D) registration (i.e., alignment) between two microscopic images is very helpful to study tissues that do not adhere to substrates, such as mouse embryos and organoids, which are often 3D rotated during imaging. However, there is no 3D registration tool easily accessible for experimental biologists. Here we developed an ImageJ-based tool which allows for 3D registration accompanied with both quantitative evaluation of the accuracy and reconstruction of 3D rotated images. In this tool, several landmarks are manually provided in two images to be aligned, and 3D rotation is computed so that the distances between the paired landmarks from the two images are minimized. By simultaneously providing multiple points (e.g., all nuclei in the regions of interest) other than the landmarks in the two images, the correspondence of each point between the two images, i.e., to which nucleus in one image a certain nucleus in another image corresponds, is quantitatively explored. Furthermore, 3D rotation is applied to one of the two images, resulting in reconstruction of 3D rotated images. We demonstrated that this tool successfully achieved 3D registration and reconstruction of images in mouse pre- and post-implantation embryos, where one image was obtained during live imaging and another image was obtained from fixed embryos after live imaging. This approach provides a versatile tool applicable for various tissues and species. 相似文献