首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   468篇
  免费   39篇
  国内免费   2篇
  509篇
  2024年   1篇
  2023年   11篇
  2022年   64篇
  2021年   93篇
  2020年   64篇
  2019年   40篇
  2018年   39篇
  2017年   28篇
  2016年   18篇
  2015年   27篇
  2014年   30篇
  2013年   29篇
  2012年   14篇
  2011年   9篇
  2010年   6篇
  2009年   4篇
  2008年   7篇
  2007年   4篇
  2006年   4篇
  2005年   2篇
  2004年   1篇
  2002年   1篇
  1999年   2篇
  1997年   3篇
  1996年   2篇
  1994年   1篇
  1993年   1篇
  1992年   3篇
  1987年   1篇
排序方式: 共有509条查询结果,搜索用时 15 毫秒
461.
PurposeAdaptive Stereotactic Body Radiotherapy (SBRT) of prostate cancer (PC) by online 1.5 T MRi-guidance prolongs session-time, due to contouring and planning tasks, thus increasing the risk of prostate motion. Hence, the interest to verify the adequacy of the delivered dose.Material and methodsFor twenty PC patients treated by 35 Gy (Dp) in five fractions, daily pre- and post- delivery MRi scans were respectively used for adapt-to-shape (ATS) optimization, and re-computation of the delivered irradiation (Drec). Two expansion recipes, from Clinical (CTV) to Planning target volume (PTV), which slightly differed in the posterior margin were used for groups I and II, of ten patients each. Plans had to assure D95% ≥ 95%Dp to PTV, and D1cc ≤ Dp to rectum, bladder, penile bulb, and urethral planning-risk-volume (urethral-PRV). The adequacy of the delivered dose was estimated by inter-fraction average (ifa) of dose-volume metrics computed from Drec. A cumulative dose (Dsum) was calculated from the five daily Drec deformed onto the simulation MRi.ResultsFor each patient, CTV coverage resulted in D95% > 95%Dp when estimated as ifa by Drec. No significant difference for D95% and D99% metrics to CTV resulted between groups I and II. D1cc was < Dp for rectum, urethral-PRV, and penile bulb, whereas < 103.5%Dp for the bladder.Significant correlations resulted between metrics computed by Dsum and as ifa by Drec, by both linear-correlation analysis, and Receiver-Operating-Characteristic curve analysis.ConclusionsOur results for PC-SBRT confirm the adequacy of the delivered dose by ATS with 1.5 T MR-linac, and the consistency between dose-volume metrics computed by Drec and Dsum.  相似文献   
462.
Radical radiotherapy of lung cancer with dose escalation has been associated with increased tumor control. However, these attempts to continually improve local control through dose escalation, have met mixed results culminating in the findings of the RTOG trial 0617, where the heart dose was associated with a worse overall survival, indicating a significant contribution to radiation-induced cardiac morbidity. It is, therefore, very likely that poorly understood cardiac toxicity may have offset any potential improvement in overall survival derived from dose escalation and may be an obstacle that limits disease control and survival of patients. The manifestations of cardiac toxicity are relatively common after high dose radiotherapy of advanced lung cancers and are independently associated with both heart dose and baseline cardiac risk. Toxicity following the treatment may occur earlier than previously thought and, therefore, heart doses should be minimized. In patients with lung cancer, who not only receive substantial heart dose, but are also older with more comorbidities, all cardiac events have the potential to be clinically significant and life-threatening.Sophisticated radiation treatment planning techniques, charged particle therapy, and modern imaging methods in radiotherapy planning, may lead to reduction of the heart dose, which could potentially improve the clinical outcomes in patients with lung cancer. Efforts should be made to minimize heart radiation exposure whenever possible even at doses lower than those generally recommended. Heart doses should be limited as much as possible.A heart dosimetry as a whole is important for patient outcomes, rather than emphasizing just one parameter.  相似文献   
463.
Aim and backgroundTo assess the use of hypofractionated (HG-RT) versus normofractionated radiation therapy (NF-RT) in Breast Cancer in German speaking countries.Materials and methodsBetween July 2017 and August 2017, an email-based survey was sent to all 1408 physicians that are members of the German Society of Radiation Oncology (DEGRO). The survey was completed by 180 physicians including 10 private practice owners and 52 heads of departments. The majority (82.1%) of the participants had >15 years of experience in radiation therapy (RT).ResultsThe majority (83.9%) of the heads of the departments agreed on using the normofractionated regimen of RT as standard treatment for breast cancer. Several physicians were skeptical about HF-RT with 6.5% of the heads refusing to use HF-RT. 40.3% of the departments had not seen the new German guidelines suggesting HF-RT as the standard treatment for all patients as positive or merely adopted a neutral position toward the guidelines (33.9%). The main points of criticism were increased side effects, an impaired toxicity profile and insufficient data. Most departments (46.8%) that perform HF-RT do so in an individual based manner.ConclusionsHF-RT remains controversial in German speaking countries. Our data shows that NF-RT remains the predominant method of treatment. HF-RT is only used in a defined group of patients as most German physicians agree that particular patients, especially those at higher risk of RT late effects, may benefit from a less intense, extended fractionation schedule.  相似文献   
464.
PurposeCarbon ion radiotherapy (CIRT) is sensitive to anatomical density variations. We examined the dosimetric effect of variable intestinal filling condition during CIRT to ten sacral chordoma patients.MethodsFor each patient, eight virtual computed tomography scans (vCTs) were generated by varying the density distribution within the rectum and the sigmoid in the planning computed tomography (pCT) with a density override approach mimicking a heterogeneous combination of gas and feces. Totally full and empty intestinal preparations were modelled. In addition, five different intestinal filling conditions were modelled by a mixed density pattern derived from two combined and weighted Gaussian distributions simulating gas and feces respectively. Finally, a patient-specific mixing proportion was estimated by evaluating the daily amount of gas detected in the cone beam computed tomography (CBCT). Dose distribution was recalculated on each vCT and dose volume histograms (DVHs) were examined.ResultsNo target coverage degradation was observed at different vCTs. Rectum and sigma dose degradation ranged respectively between: [−6.7; 21.6]GyE and [−0.7; 15.4]GyE for D50%; [−377.4; 1197.9] and [−95.2; 1027.5] for AUC; [−1.2; 10.7]GyE and [−2.6; 21.5]GyE for D1%.ConclusionsVariation of intestinal density can greatly influence the penetration depth of charged particle and might compromise dose distribution. In particular cases, with large clinical target volume in very close proximity to rectum and sigmoid colon, it is appropriate to evaluate the amount of gas present in the daily CBCT images even if it is totally included in the reference planning structures.  相似文献   
465.
AimThe primary aim of this study is to provide preliminary indications for safe constraints of rectum and bladder in patients re-irradiated with stereotactic body RT (SBRT).MethodsData from patients treated for prostate cancer (PCa) and intraprostatic relapse, from 1998 to 2016, were retrospectively collected. First RT course was delivered with 3D conformal RT techniques, SBRT or volumetric modulated arc therapy (VMAT). All patients underwent re-irradiation with SBRT with heavy hypofractionated schedules. Cumulative dose-volume values to organs at risk (OARs) were computed and possible correlation with developed toxicities was investigated.ResultsTwenty-six patients were included. Median age at re-irradiation was 75 years, mean interval between the two RT courses was 5.6 years and the median follow-up was 47.7 months (13.4–114.3 months). After re-irradiation, acute and late G ≥ 2 GU toxicity events were reported in 3 (12%) and 10 (38%) patients, respectively, while late G ≥ 2 GI events were reported in 4 (15%) patients. No acute G ≥ 2 GI side effects were registered. Patients receiving an equivalent uniform dose of the two RT treatments < 131 Gy appeared to be at higher risk of progression (4-yr b-PFS: 19% vs 33%, p = 0.145). Cumulative re-irradiation constraints that appear to be safe are D30% < 57.9 Gy for bladder and D30% < 66.0 Gy, D60% < 38.0 Gy and V122.1 Gy < 5% for rectum.ConclusionPreliminary re-irradiation constraints for bladder and rectum have been reported. Our preliminary investigation may serve to clear some grey areas of PCa re-irradiation.  相似文献   
466.
467.
PurposeEvaluation of the out-of-field dose is an important aspect in radiotherapy. Due to the fetus radiosensitivity, this evaluation becomes even more conclusive when the patient is pregnant. In this work, a linear accelerator Varian Clinac 2100c operating at 6 MV, a pregnant anthropomorphic phantom (Maria), and different shields added above the abdominal region of the phantom were used for the analysis based on MCNPX. Methods: The simulations were performed for the medial and lateral projections, using either an open field collimation (10×16 cm2) or a multileaf collimator. The added shields (M1 and M2) were designed based on models proposed by Stovall et al. [1], intending to reduce the deposited dose on the fetus and related structures. Results: The presence of the shields showed to be effective in reducing the doses on the fetus, amniotic sac, and placenta, for example. A reduction of about 43% was found in the dose on the fetus when M2 was added, using the open field collimation, in comparison with the situation with no shield, being the lateral projection the main responsible for the dose. The use of MLC significatively reduced the doses in different structures, including on the fetus and amniotic sac, for example, in comparison to the open field situation. A slight increment on the dose in organs such as the eyes, thyroid and brain was found in both collimation systems, due to the presence of the shields. The contribution of the leakage radiation from the tube head of the linear accelerator was found to be in the order of µGy, being reduced by the presence of the M2 shield. Conclusion: Using the shields showed to be an essential feature in order to reduce the dose not only on the fetus, but also in important structures responsible to its development.  相似文献   
468.
IntroductionDeformable image registration (DIR) can play an important role in the context of adaptive radiotherapy. The AAPM Task Group 132 (TG-132) has described several quantitative measures for DIR error assessment but they can only be accurately defined when there is a ground-truth present in high-contrast regions. This work aims to set out a framework to obtain optimal results for CT-CT lung DIR in clinical setting for a commercially available system by quantifying the DIR performance in both low- and high-contrast regions.MethodsFive publicly available thorax datasets were used to assess the DIR quality. A “Ghost fiducial” method was implemented by windowing the contrast in a new feature provided by Varian Velocity v4.1. Target registration error (TRE) of the landmarks and Dice-similarity coefficient of the tumour were calculated at three different contrast settings to assess the algorithm in high- and low-contrast scenarios.ResultsFor the original unedited dataset, higher resolution DIR methods showed best performance acceptable within the recommended limit according to TG-132, when actual displacements were less than 10 mm. The relation of the actual displacement of the landmarks and TRE shows the limited capacity of the algorithm to deal with movements larger than 10 mm.ConclusionThis work found the performance of DIR methods and settings available in Varian Velocity v4.1 to be a function of contrast level as well as extent of motion. This highlights the need for multiple metrics to assess different aspects of DIR performance for various applications related to low-contrast and/or high-contrast regions.  相似文献   
469.
PurposeA situational awareness Bayesian network (SA-BN) approach is developed to improve physicians’ trust in the prediction of radiation outcomes and evaluate its performance for personalized adaptive radiotherapy (pART).Methods118 non-small-cell lung cancer patients with their biophysical features were employed for discovery (n = 68) and validation (n = 50) of radiation outcomes prediction modeling. Patients’ important characteristics identified by radiation experts to predict individual’s tumor local control (LC) or radiation pneumonitis with grade ≥ 2 (RP2) were incorporated as expert knowledge (EK). Besides generating an EK-based naïve BN (EK-NBN), an SA-BN was developed by incorporating the EK features into pure data-driven BN (PD-BN) methods to improve the credibility of LC or / and RP2 prediction. After using area under the free-response receiver operating characteristics curve (AU-FROC) to assess the joint prediction of these outcomes, their prediction performances were compared with a regression approach based on the expert yielded estimates (EYE) penalty and its variants.ResultsIn addition to improving the credibility of radiation outcomes prediction, the SA-BN approach outperformed the EYE penalty and its variants in terms of the joint prediction of LC and RP2. The value of AU-FROC improves from 0.70 (95% CI: 0.54–0.76) using EK-NBN, to 0.75 (0.65–0.82) using a variant of EYE penalty, to 0.83 (0.75–0.93) using PD-BN and 0.83 (0.77–0.90) using SA-BN; with similar trends in the validation cohort.ConclusionsThe SA-BN approach can provide an accurate and credible human–machine interface to gain physicians’ trust in clinical decision-making, which has the potential to be an important component of pART.  相似文献   
470.
Radiotherapy is being performed in many situations as a curative approach for head and neck cancer instead of surgery due to the current novel coronavirus disease (COVID-19) pandemic. A recent publication reported that even hypofractionation was being conducted in order to reduce the daily exposure of both patients and the medical staff involved in cancer therapies. As a result, dental teams may be requested more frequently than usual to fabricate intraoral stents (IOS). Given that IOS may be a potential source of COVID-19 contagion, the main purpose of the present correspondence is to offer a guide on how health professionals may be safely presented in the room, on the management of the IOS and also how to sanitize the stents.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号