Arquimedes Paixão de Santana-FilhoGuilhermina Rodrigues Noleto Philip Albert James GorinLauro Mera de Souza Marcello IacominiGuilherme Lanzi Sassaki 《Carbohydrate polymers》2012,87(4):2730-2734
The most common method used to quantify lipopolysaccharide (LPS) in polysaccharide samples is the Limulus amebocyte lysate (LAL) test. It is a very sensitive and simple, although not accurate with samples containing carbohydrates, such as widely distributed (1 → 3)-linked β-glucans. Another method, the Polymyxin B assay, suffers interference with samples containing negatively charged polysaccharides. We have now developed a method to detect and quantify LPS in carbohydrate-containing samples, using GC-MS of derived acetylated 3-OH fatty acid methyl esters. The method proved to be robust, highly specific and sensitive, allowing detection of LPS at 1 ng, 100 times less than the amount of LPS frequently used as positive control in immunological experiments. In order to demonstrate the applicability of the method, 14 polysaccharide samples were analyzed. On two of them, the presence of LPS was detected at concentrations of 16.1 and 12.7 ng/300 μg polysaccharide. 相似文献
12.
13.
Mingfei Pan Junping WangGuozhen Fang Weiwei TangShuo Wang 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(19):1531-1536
A novel molecularly imprinted polymer that could be applied as enrichment sorbent was prepared using methimazole (MMZ) as the template molecule, methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker. Though evaluated by static, kinetic and competitive adsorption tests, the polymer exhibited high adsorption capacity, fast kinetics and good selective ability. A method for determination of trace MMZ was developed using this polymer as enrichment sorbent coupled with high performance liquid chromatography focusing on complex biological matrices. Under the optimum experimental conditions, the MMZ standard is linear within the concentration range studied, that is, from 0.5 μg L−1 to 150 μg L−1 (r2 = 0.9941). Lower limits of detection (LOD, at S/N = 3) and quantification (LOQ, at S/N = 10) in pig samples were 0.63 μg kg−1 and 2.10 μg kg−1 for kidney, 0.51 μg kg−1 and 1.70 μg kg−1 for liver, 0.56 μg kg−1 and 1.86 μg kg−1 for muscle, respectively. Recoveries and relative standard deviation (RSD, n = 9) values for precision in the developed method were from 71.14% to 88.41% and from 2.53% to 6.18%. 相似文献
14.
Lena Hausdorf Maria NeumannIngo Bergmann Kerstin SobiellaKerstin Mundt Antje FröhlingOliver Schlüter Michael Klocke 《Systematic and applied microbiology》2013
Some species of the genus Arcobacter are considered to be emerging food pathogens. With respect to recent vegetable-borne outbreaks, the aim of this work was to investigate the occurrence and diversity of Arcobacter within the production chain of a spinach-processing plant by a combination of cultivation and molecular methods. Samples including spinach, water, and surface biofilm were taken over a period of three years from the entire processing line. Ten 16S rRNA (rrs) gene clone libraries were constructed and analysed using amplified rRNA gene restriction analysis (ARDRA). Approximately 1200 clones were studied that resulted in 44 operational taxonomic units (OTUs). Sequences with high similarities to Arcobacter cryaerophilus (13% of clones, 3 OTUs), A. ellisii (4%, 6 OTUs), A. suis (15%, 3 OTUs), and the type strain of A. nitrofigilis (1%, 7 OTUs) were identified. This represents the first report of the detection of the recently described species A. ellisii, A. suis and, in addition, A. venerupis from alternative habitats. A total of 67% of the clones (22 OTUs) could not be assigned to a genus, which indicated the presence of uncharacterised Arcobacter species. 相似文献
15.
Several different techniques suggested by the International Conference on Harmonization (ICH) Q2R1 guideline were used to assess the signal and concentration at the limit of detection (LOD) and limit of quantitation (LOQ) for a purity method. These approaches were exemplified with a capillary isoelectrofocusing (cIEF) method, which has been developed to quantify the distribution of the charge isoforms of a monoclonal antibody. The charge isoforms are the result of incomplete posttranslational processing of C-terminal lysine residues of the heavy chain by carboxypeptidase. Results showed no significant discrepancy between LOD/LOQ obtained by the different techniques. Validation experiments corroborated the calculated LOQ. The results indicate that any single technique can provide meaningful values for the LOD and LOQ. Finally, important points to consider when applying these techniques to purity methods are discussed. 相似文献
16.
Shu-Ping Hui Hitoshi Chiba Shigeki Jin Hironori Nagasaka Takao Kurosawa 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(20):1677-1682
A new liquid chromatography mass spectrometry (LC/MS) method has been developed for the qualitative and quantitative analyses of phosphatidylcholine hydroperoxides (PC-OOH) in human plasma using a synthetic hydroperoxide (1-stearoyl-2-erucoyl-PC monohydroperoxide, PC 18:0/22:1-OOH) as an internal standard. 1-Stearoyl-2-linoleoyl-PC monohydroperoxide (PC 18:0/18:2-OOH) was identified in plasma by LC/MS by comparison with an authentic standard. The calibration curves obtained for 1-palmitoyl-2-linoleoyl-PC monohydroperoxide, PC 16:0/18:2-OOH and PC 18:0/18:2-OOH were linear throughout the calibration range (0.1–1.0 pmol). The limit of detection (LOD) (S/N = 3:1) was 0.01 pmol, and the limit of quantification (LOQ) (S/N = 6:1) was 0.1 pmol for both PC 16:0/18:2-OOH and PC 18:0/18:2-OOH. Plasma concentrations of PC 16:0/18:2-OOH and PC 18:0/18:2-OOH were 89 and 32 nM, respectively, in a healthy volunteer. 相似文献
17.
Susanne H. Kirsch Jean-Pierre KnappWolfgang Herrmann Rima Obeid 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(1):68-75
Folates act as essential coenzymes in many biological pathways. Alteration in folate form distribution might have biological significance, especially in relation to certain genetic polymorphisms. We developed a stable-isotope dilution ultra performance liquid chromatography–mass spectrometry (UPLC–MS/MS) method for quantification of the folate forms 5-methyltetrahydrofolate (5-methylTHF), 5-formylTHF, 5,10-methenylTHF, THF, and folic acid in serum. After extraction using an ion exchange and mixed mode solid-phase, samples were separated and detected using an UPLC–MS/MS system. The quantification limits were between 0.17 nmol/L (5-formylTHF) and 1.79 nmol/L (THF), and the assay was linear up to 100 nmol/L (5-methylTHF) and 10 nmol/L (5-formylTHF, 5,10-methenylTHF, THF, and folic acid). The intraassay CVs for 5-methylTHF and 5-formylTHF were 2.0% and 7.2%, respectively. Mean recoveries were between 82.3% for THF and 110.8% for 5,10-methenylTHF. Concentrations of total folate measured by the new method showed a strong correlation with those measured by an immunologic assay (r = 0.939; p < 0.001). The mean total folate from 32 apparently healthy subjects was 18.09 nmol/L, of which 87.23% was 5-methylTHF. Concentrations of homocysteine showed a better correlation to the total folate measured by the new method compared to that obtained by an immunologic assay. We also confirmed that MTHFR polymorphism has a significant effect on folate distribution in this small population of non-supplemented subjects. 相似文献