排序方式: 共有129条查询结果,搜索用时 10 毫秒
41.
Komyod W Bauer UM Heinrich PC Haan S Behrmann I 《The Journal of biological chemistry》2005,280(23):21700-21705
42.
Tisgratog R Tananchai C Bangs MJ Tainchum K Juntarajumnong W Prabaripai A Chauhan KR Pothikasikorn J Chareonviriyaphap T 《Journal of vector ecology》2011,36(2):321-331
Behavioral responses of female mosquitoes representing two species in the Minimus Complex exposed to an operational field dose of bifenthrin or DEET (N,N-diethyl-m-toluamide) were described using an excito-repellency test system. Two test populations of An. minimus, one from the field (Tak Province, western Thailand), the other from a long-established laboratory colony, and Anopheles harrisoni collected from Kanchanaburi Province, western Thailand, were used. Results showed that all test populations rapidly escaped after direct contact with surfaces treated with either bifenthrin or DEET compared to match-paired untreated controls. Greater escape response by exposed females to bifenthrin and DEET were observed in the An. minimus colony compared to the two field populations. Field-collected An. minimus demonstrated a more rapid escape response to DEET than to bifenthrin, whereas An. harrisoni showed a converse response. Although fewer females escaped from test chambers without direct contact with treated surfaces compared to contact tests, the spatial repellency response was significantly pronounced in all test populations compared to match-paired controls (P < 0.05). DEET was found to perform as both a contact stimulant and moderate spatial repellent. 相似文献
43.
Maneewan Suwansaard Wanna Choorit Jill H. Zeilstra-Ryalls Poonsuk Prasertsan 《Biotechnology letters》2010,32(11):1667-1671
Rhodopseudomonas palustris TN1 was isolated from Songkhla Lake, Thailand. It phototrophically generates H2 from the predominant volatile fatty acids (VFAs) produced from microbial dark-fermentations of palm oil milling effluent; yields from 20 mM butyrate, acetate and propionate were 4.7, 2.5, and 1.7 mol H2 mol VFA−1 with light efficiencies of 1.8, 1, and 0.2%, respectively. Optimum conditions were pH 7 and 3000 lux, although production was reduced by only 33% at 1000 lux. CO2 evolution never exceeded 9 mmol mol VFA−1. 相似文献
44.
45.
Pimwan Thongdee Wanna Chaijaroenkul Jiraporn Kuesap Kesara Na-Bangchang 《The Korean journal of parasitology》2014,52(4):377-381
Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application. 相似文献
46.
Saichit Khummuang Waraporn Phanphrom Witida Laopajon Watchara Kasinrerk Ponlatham Chaiyarit Supansa Pata 《Biological procedures online》2017,19(1):14
Background
Human trefoil factor (TFF) peptides consist of three members: TFF1, TFF2 and TFF3. TFF3 is the most abundant TFF peptide in saliva. TFF3 homodimer was suggested to be involved in apoptosis inhibition and malignancy. Determination of TFF3 homodimer expression profiles in saliva may lead to new information about oral biology and diseases. The objective of this study was to generate monoclonal antibodies (mAbs) against TFF3 and apply the produced mAbs for the establishment of ELISA for quantification of dimeric TFF3 in saliva.Results
With our modified hybridoma technique, three hybridoma clones producing anti-TFF3 mAbs having IgG isotype were generated. The mAbs were specific for TFF3 with no cross-reactivity to other TFFs. Using the generated mAbs, a modified-sandwich ELISA with high sensitivity for the quantification of dimeric TFF3 in saliva was developed. Using this ELISA, the amount of dimeric TFF3 in saliva could be measured.Conclusions
A modified-sandwich ELISA for the quantification of TFF3 dimeric form was established. The established ELISA will be a valuable tool for facilitating the investigation of the physiological roles and the diagnostic values of TFF3 in oral diseases. The concept of this modified-sandwich ELISA may be applied for the determination of other homodimeric peptides of interest.47.
48.
49.
Enzyme‐linked immunosorbent assay by enhanced chemiluminescence detection for the standardization of estrogenic miroestrol in Pueraria candollei Graham ex Benth 下载免费PDF全文
Gorawit Yusakul Orapin Udomsin Hiroyuki Tanaka Satoshi Morimoto Thaweesak Juengwatanatrakul Waraporn Putalun 《Luminescence》2015,30(5):568-575
Miroestrol (ME) is a potent phytoestrogen from the P. candollei tuberous root. It has been approved for use in clinical trials due to its beneficial effect on disorders associated with estrogen deficiency. To ensure medical efficacy and safety, high performance analytical methods for ME analysis are required to standardize products from the P. candollei root. An enhanced chemiluminescence enzyme‐linked immunosorbent assay (ECL‐ELISA) was developed and validated using a polyclonal antibody against ME and a chemiluminescent system of luminol–H2O2–horseradish peroxidase‐4‐(1‐imidazolyl) phenol. The ECL‐ELISA system exhibited linearity over a concentration range of 0.31–10.00 ng mL?1, for which the relative standard variation (%RSD) was less than 10% for both intra‐ and interplate determinations. The ECL‐ELISA is reliable for the determination of ME as reflected by the high recovery percentage (101.22–103.06%). As a comparative analysis, the ME content in each sample determined by ECL‐ELISA was correlated with high coefficients of determination with colorimetric ELISA (R2 = 0.998) and high performance liquid chromatography (HPLC) (R2 = 0.998) methods. The ECL‐ELISA method could be applied to all of the commercial products containing P. candollei root, when the products contain between 0.706 ± 0.046 and 13.123 ± 0.794 µg g?1 dry wt. of ME. This method is useful as a high performance analytical method for the quantity control of ME in raw materials and end products at both the research and industrial levels. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
50.
Development of a one-step immunochromatographic strip test for the detection of sennosides A and B 总被引:5,自引:0,他引:5
An immunochromatographic strip test was developed to detect sennoside A (1) and sennoside B (2) using anti-1 and anti-2 monoclonal antibodies. The qualitative assay was based on a competitive immunoassay in which the detector reagent consisted of colloidal gold particles coated with the respective sennoside antibodies. The capture reagents were 1- and 2-human serum albumin (HSA) conjugates immobilised on a nitrocellulose membrane on the test strip. The sample containing 1 and 2, together with detector reagent, passed over the zone where the capture reagents had been immobilised. The analytes in the sample competed for binding to the limited amount of antibodies in the detector reagent with the immobilised 1- and 2-HSA conjugates on the membrane and hence positive samples showed no colour in the capture spot zone. Detection limits for the strip test were 125 ng/mL for both sennosides. The assay system is useful as a rapid and simple screening method for the detection of 1 and 2 in plants, drugs and body fluids. 相似文献