排序方式: 共有34条查询结果,搜索用时 15 毫秒
31.
Background
In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress-shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress-shielding at the fracture-interface immediately after fracture-fixation delays callus formation and bone healing. Likewise, the tensile stress-shielding of the layer of the bone underneath the plate can cause osteoporosis and decrease in tensile strength of this layer. 相似文献32.
Huang J Gautam N Bathena SP Roy U McMillan J Gendelman HE Alnouti Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(23):2332-2338
Animal pharmacokinetic and tissue distribution assays of antiretroviral therapeutic drugs require accurate drug quantification in biological fluids and tissues. Here we report a simple, rapid, and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for quantification of commonly used antiretroviral drugs ritonavir (RTV), indinavir (IDV), atazanavir (ATV), and efavirenz (EFV) in mouse serum and tissues (liver, kidney, lung, and spleen). These antiretroviral drugs are currently the cornerstones of common therapeutic regimens for human immunodeficiency virus (HIV) infection. Chromatographic separation was achieved using a gradient mobile phase (5% acetonitrile in methanol and 7.5mM ammonium acetate (pH 4.0)) on an ACQUITY UPLC(?)BEH Shield RP 18 column. All compounds eluted within a 7 min run time. Lopinavir was used as an internal standard. Detection was achieved by dual positive and negative ionization modes on a quadrupole linear ion trap hybrid mass spectrometer with an electrospray ionization (ESI) source. The dynamic range was 0.2-1000 ng/mL for RTV, IDV, and ATV, and 0.5-1000 for EFV. The method was validated and showed high and consistent intra-day and inter-day accuracy and precision for all analytes. This method is used to support the preclinical development studies of targeted- and sustained-release combination ART (nanoART). The current data demonstrate a 1.5-4 fold increase in serum and tissue AUC of nanoformulated ATV, RTV, and EFV administered to mice when compared to native drug. In addition, the tested formulation enhanced exposure of the same anti-HIV drugs in mouse tissues. 相似文献
33.
Revathi?Rajkumar Jheelam?Banerjee Hima?Bindu?Gunturi R?Trivedi VK?KashyapEmail author 《BMC evolutionary biology》2005,5(1):26
Background
Analysis of human complete mitochondrial DNA sequences has largely contributed to resolve phylogenies and antiquity of different lineages belonging to the majorhaplogroups L, N and M (East-Asian lineages). In the absence of whole mtDNA sequence information of M lineages reported in India that exhibits highest diversity within the sub-continent, the present study was undertaken to provide a detailed analysis of this macrohaplogroup to precisely characterize and unravel the intricate phylogeny of the lineages and to establish the antiquity of M lineages in India. 相似文献34.
P. Diana Subramanian Saravanakumar D. Sivaganesh V. Sivakumar Yang Li S. Sebastian Ji-Man Kim Padmanathan Karthick Kannan L. Sangeetha Vijayendran K. K. Praneeth 《Luminescence》2023,38(5):625-636
The present investigation deals with the effect of calcination temperature on the structural and thermoluminescent (TL) properties of Zn2SiO4 materials. For this study, Zn2SiO4 was prepared via a simple hydrothermal route and calcinated at temperatures from 700°C to 1100°C in an air atmosphere. TL data of all Zn2SiO4 samples showed two peaks at around 240°C and 330°C due to the formation of the luminescence centre during X-ray irradiation. More interestingly, the Zn2SiO4 sample calcinated at 900°C exhibited a shift in the TL peak (282°C and 354°C) with an optimal TL intensity attributed to its good crystallinity with a well-defined hexagonal plate-like morphology. X-ray-irradiated Zn2SiO4 samples calcinated at 900°C exhibited a high-temperature TL glow curve peak, suggesting that the present material could be used for high-temperature dosimetry applications. 相似文献