首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   11篇
  免费   3篇
  2021年   1篇
  2020年   2篇
  2017年   1篇
  2015年   2篇
  2014年   4篇
  2013年   1篇
  2011年   1篇
  2010年   1篇
  2005年   1篇
排序方式: 共有14条查询结果,搜索用时 15 毫秒
11.
Precise localization of epileptic foci is an unavoidable prerequisite in epilepsy surgery. Simultaneous EEG-fMRI recording has recently created new horizons to locate foci in patients with epilepsy and, in comparison with single-modality methods, has yielded more promising results although it is still subject to limitations such as lack of access to information between interictal events. This study assesses its potential added value in the presurgical evaluation of patients with complex source localization. Adult candidates considered ineligible for surgery on account of an unclear focus and/or presumed multifocality on the basis of EEG underwent EEG-fMRI. Adopting a component-based approach, this study attempts to identify the neural behavior of the epileptic generators and detect the components-of-interest which will later be used as input in the GLM model, substituting the classical linear regressor. Twenty-eight sets interictal epileptiform discharges (IED) from nine patients were analyzed. In eight patients, at least one BOLD response was significant, positive and topographically related to the IEDs. These patients were rejected for surgery because of an unclear focus in four, presumed multifocality in three, and a combination of the two conditions in two. Component-based EEG-fMRI improved localization in five out of six patients with unclear foci. In patients with presumed multifocality, component-based EEG-fMRI advocated one of the foci in five patients and confirmed multifocality in one of the patients. In seven patients, component-based EEG-fMRI opened new prospects for surgery and in two of these patients, intracranial EEG supported the EEG-fMRI results. In these complex cases, component-based EEG-fMRI either improved source localization or corroborated a negative decision regarding surgical candidacy. As supported by the statistical findings, the developed EEG-fMRI method leads to a more realistic estimation of localization compared to the conventional EEG-fMRI approach, making it a tool of high value in pre-surgical evaluation of patients with refractory epilepsy. To ensure proper implementation, we have included guidelines for the application of component-based EEG-fMRI in clinical practice.  相似文献   
12.
13.
There are currently several initiatives that aim to produce binding reagents for proteome‐wide analysis. To enable protein detection, visualization, and target quantification, covalent coupling of reporter molecules to antibodies is essential. However, current labeling protocols recommend considerable amount of antibodies, require antibody purity and are not designed for automation. Given that small amounts of antibodies are often sufficient for downstream analysis, we developed a labeling protocol that combines purification and modification of antibodies at submicrogram quantities. With the support of magnetic microspheres, automated labeling of antibodies in parallel using biotin or fluorescent dyes was achieved.  相似文献   
14.
Abstract

In this paper, we have studied the in vitro binding of neotame (NTM), an artificial sweetener, with native calf thymus DNA using different methods including spectrophotometric, spectrofluorometric, competition experiment, circular dichroism (CD), and viscosimetric techniques. From the spectrophotometric studies, the binding constant (Kb) of NTM-DNA was calculated to be 2?×?103 M?1. The quenching of the intrinsic fluorescence of NTM in the presence of DNA at different temperatures was also used to calculate binding constants (Kb) as well as corresponding number of binding sites (n). Moreover, the obtained results indicated that the quenching mechanism involves static quenching. By comparing the competitive fluorimetric studies with Hoechst 33258, as a known groove probe, and methylene blue, as a known intercalation probe, and iodide quenching experiments it was revealed that NTM strongly binds in the grooves of the DNA helix, which was further confirmed by CD and viscosimetric studies. In addition, a molecular docking method was employed to further investigate the binding interactions between NTM and DNA, and confirm the obtained results.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号