全文获取类型
收费全文 | 86篇 |
免费 | 7篇 |
专业分类
93篇 |
出版年
2019年 | 1篇 |
2018年 | 1篇 |
2017年 | 2篇 |
2016年 | 3篇 |
2015年 | 1篇 |
2014年 | 1篇 |
2013年 | 9篇 |
2012年 | 4篇 |
2011年 | 4篇 |
2010年 | 4篇 |
2009年 | 5篇 |
2008年 | 3篇 |
2007年 | 1篇 |
2006年 | 1篇 |
2005年 | 1篇 |
2004年 | 1篇 |
2003年 | 2篇 |
2002年 | 1篇 |
2001年 | 1篇 |
2000年 | 1篇 |
1999年 | 1篇 |
1997年 | 1篇 |
1993年 | 2篇 |
1991年 | 2篇 |
1989年 | 2篇 |
1988年 | 2篇 |
1987年 | 3篇 |
1986年 | 9篇 |
1985年 | 5篇 |
1984年 | 1篇 |
1983年 | 5篇 |
1982年 | 1篇 |
1981年 | 2篇 |
1980年 | 5篇 |
1979年 | 1篇 |
1977年 | 1篇 |
1971年 | 1篇 |
1970年 | 1篇 |
1928年 | 1篇 |
排序方式: 共有93条查询结果,搜索用时 0 毫秒
91.
J. R. Aldrich J. E. Oliver W. R. Lusby J. P. Kochansky 《Archives of insect biochemistry and physiology》1986,3(1):1-12
In the nearctic predaceous stink bugs (Asopinae), Perillus bioculatus and Stiretrus anchorago, and the neotropical asopine, Oplomus severus, males possess conspicuous sternal glands that are absent in females. In each of these species, the male sternal gland secretion contains predominantly a single compound; 6,10,13-trimethyltetradecyl isovalerate in the allopatric species, P. bioculatus and O. severus, and 6,10,13-trimethyltetradecanol in S. anchorago, a species sympatric with P. bioculatus. The function of the sternal gland secretions from asopine hemipterans is unknown. 相似文献
92.
Panagrellus redivivus produced 24-methyl-23-dehydrocholesterol as 4.0% of the 4-desmethylsterols when propagated in a medium containing campesterol as the dietary sterol. The re-examination of previous data revealed that Caenorhabditis elegans produced 1.8% 24-methyl-23-dehydrocholesterol when propagated in medium containing campesterol. 24-Methyl-23-dehydrocholesterol was not detected when the nematodes were propagated in medium containing 22-dihydrobrassicasterol or 24-methylenecholesterol. This may be a result of the greater efficiency of dealkylation of the latter two sterols. This is the first report of the natural occurrence of this sterol in a non-photosynthetic organism, and the first report in organisms that dealkylate 24-alkylsterols. 相似文献
93.
Blaine F. Severin Ph. D PE. Peter F. Roessler Jyotirmoy Dey 《Quantitative Microbiology》1999,1(2):111-136
A UV reactor with an annular design, a total liquid volume of 460[emsp4 ]ml, and outfitted with a single lamp with 1690[emsp4 ]mW of germicidal power was tested. Coliphage MS2 was used as a bioactinometer to measure the UV dose at a flow rate of 56.7[emsp4 ]ml/sec in water with a very low absorbance. The Beers Law coefficient was A100.003. The measured dose (MS2 bioactinometry) was 35.2±1.1[emsp4 ]mW-sec/cm2.A retention time distribution was generated with a dye tracer study. The reactor was modeled as if flow was confined to ten equal volume paths existing as concentric rings around the lamp. The UV intensity along each path (ith intensity) was calculated to generate a simulated distribution of UV intensity in the reactor. The retention time distribution was subdivided to estimate the retention time associated with each decile jth time) of the total flow.Seven methods of associating the ith intensity with the jth retention time were used to produce simulated dose distributions for the reactor. The average UV dose for each distribution was calculated as the average of the products of I and t (AP protocol) and by the apparent survival (AS protocol), in which the predicted survival along each path was averaged to back-calculate dose from the reference batch inactivation curve. The average dose predicted assuming that time and intensity were independent was 51.5[emsp4 ]mW-sec/cm2 based on the arithmetic average (AP protocol). Using the apparent survival method, the predicted dose for the independent distribution (I independent of t) was 36.4[emsp4 ]mW-sec/cm2. Three methods of developing dependent structure between time and intensity were tested. In the best possible case for stratified flow (I negatively correlated with t) the calculated (AS) intensity was 46.3[emsp4 ]mW-sec/cm2. In the worst case for stratified flow (I positively correlated with t) the AS intensity was 32.0[emsp4 ]mW-sec/cm2. In a rational case where flows were assumed to be distributed parabolically (low flow at the wall and at the lamp) produced an AS intensity of 37.7[emsp4 ]mW-sec/cm2. When either time or intensity was averaged, while the other variable was allowed to keep its distribution, the (AS) dose (time averaged 43.3[emsp4 ]mW-sec/cm2, intensity averaged 41.0[emsp4 ]mW-sec/cm2), yielded a poor prediction compared to the measured value.The errors associated with averaging time, intensity, or both, far outweigh the errors associated with choosing a rational distribution or an independent distribution of time and intensity in the prediction. This observation is generally true whenever an organism is exposed to UV light in a flow through reactor such that the range of doses is within the portion of the inactivation curve exhibiting strong exponential decay. 相似文献