首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   85篇
  免费   6篇
  91篇
  2017年   2篇
  2016年   1篇
  2015年   3篇
  2014年   1篇
  2013年   2篇
  2012年   5篇
  2011年   6篇
  2010年   4篇
  2009年   1篇
  2008年   3篇
  2007年   1篇
  2006年   4篇
  2005年   4篇
  2003年   7篇
  2002年   5篇
  2001年   2篇
  2000年   4篇
  1999年   3篇
  1998年   7篇
  1996年   1篇
  1992年   2篇
  1991年   1篇
  1989年   4篇
  1988年   4篇
  1986年   3篇
  1985年   1篇
  1983年   1篇
  1982年   2篇
  1981年   1篇
  1977年   1篇
  1975年   1篇
  1974年   1篇
  1972年   1篇
  1969年   1篇
  1967年   1篇
排序方式: 共有91条查询结果,搜索用时 0 毫秒
11.
The passive properties of skeletal muscle are often overlooked in muscle studies, yet they play a key role in tissue function in vivo. Studies analyzing and modeling muscle passive properties, while not uncommon, have never investigated the role of fluid content within the tissue. Additionally, intramuscular pressure (IMP) has been shown to correlate with muscle force in vivo and could be used to predict muscle force in the clinic. In this study, a novel model of skeletal muscle was developed and validated to predict both muscle stress and IMP under passive conditions for the New Zealand White Rabbit tibialis anterior. This model is the first to include fluid content within the tissue and uses whole muscle geometry. A nonlinear optimization scheme was highly effective at fitting model stress output to experimental stress data (normalized mean square error or NMSE fit value of 0.993) and validation showed very good agreement to experimental data (NMSE fit values of 0.955 and 0.860 for IMP and stress, respectively). While future work to include muscle activation would broaden the physiological application of this model, the passive implementation could be used to guide surgeries where passive muscle is stretched.  相似文献   
12.
We have recently reported the insensitivity of tensile failure properties of human cerebral bridging veins to strain rate. Due to data scattering, however, concerns remain regarding this finding. To pursue the issue further, the common carotid arteries and external and internal jugular veins from seven ferrets were stretched longitudinally in vitro at either a low strain rate of 0.2-2.0 s-1 or a high rate of approximately 200 s-1. The ultimate stretch ratios and loads were found to be independent of strain rate in all the vessels tested. Therefore, the present results appear to support our previous finding on human bridging veins.  相似文献   
13.
14.
The effects of strain rate on tensile failure properties of human parasagittal bridging veins were studied in eight unembalmed cadavers. While bathed in physiological saline at 37 degrees C, the intact vessel was stretched axially by a servo-controlled hydraulic testing machine at either a low strain rate of 0.1-2.5 s-1 or a high rate of 100-250 s-1. The mean ultimate stretch ratios for low and high strain rates, respectively, were 1.51 +/- 0.24 (S.D. n = 29) and 1.55 +/- 0.15 (n = 34), and the ultimate stresses were 3.24 +/- 1.65 (n = 17) and 3.42 +/- 1.38 MPa (n = 20). Neither difference between strain rates was significant (p greater than 0.45). Thus, our results do not support the hypothesis that sensitivity of the ultimate strain of bridging veins to strain rate explains the acceleration tolerance data for subdural hematoma in primates [Gennarelli, R. A. and Thibault, L. E. (1982) Biomechanics of acute subdural hematoma. J. Trauma 22, 680-686].  相似文献   
15.
ABSTRACT: BACKGROUND: The mechanisms of the antinociceptive activity of () epicatechin (EPI), a compound isolated from the hydroalcoholic fraction of Combreum leprosum Mart & Eicher. METHODS: were assessed in the model of chemical nociception induced by glutamate (20 mumol/paw). To evaluate the mechanisms involved, the animals , male Swiss mice (25-30 g), received EPI (50 mg/kg p.o.) after pretreatment with naloxone (2 mg/kg s.c. opioid antagonist), glibenclamide (2 mg/kg s.c. antagonist K + channels sensitive to ATP), ketanserin (0.3 mg/kg s.c. antagonist of receptor 5-HT2A), yoimbine (0.15 mg/kg s.c. alpha2 adrenergic receptor antagonist), pindolol (1 mg/kg s.c. 5-HT1a/1b receptor antagonist), atropine (0.1 mg/kg s.c. muscarinic antagonist) and caffeine (3 mg/kg s.c. adenosine receptor antagonist), ondansetron (0.5 mg/kg s.c. for 5-HT3 receptor) and L-arginine (600 mg/kg i.p.). RESULTS: The antinociceptive effect of EPI was reversed by pretreatment with naloxone and glibenclamide, ketanserin, yoimbine, atropine and pindolol, which demonstrates the involvement of opioid receptors and potassium channels sensitive to ATP, the serotoninergic (receptor 5HT1A and 5HT2A), adrenergic (receptor alpha 2) and cholinergic (muscarinic receptor) systems in the activities that were observed. The effects of EPI, however, were not reversed by pretreatment with caffeine, L-arginine or ondansetron, which shows that there is no involvement of 5HT3 receptors or the purinergic and nitrergic systems in the antinociceptive effect of EPI. In the Open Field and Rotarod test, EPI had no significant effect, which shows that there was no central nervous system depressant or muscle relaxant effect on the results. CONCLUSIONS: This study demonstrates that the antinociceptive activity of EPI in the glutamate model involves the participation of the opioid system, serotonin, adrenergic and cholinergic.  相似文献   
16.
Menisci are crescent shaped fibrocartilaginous structures which support load distribution of the knee. The menisci are specifically designed to fit the contour of the femoral condyles, aiding to disperse the stresses on the tibial plateau and in turn safeguarding the underlying articular cartilage. The importance of the meniscal superficial layer has not been fully revealed and it is suspected that this layer plays a pivotal role for meniscal function. In this study, both femoral (proximal) and tibial (distal) contacting meniscal surfaces were mechanically examined on the nano-level among three distinct regions (anterior, central and posterior) of the lateral and medial menisci. Nanoindentation testing showed no significant differences among regions, surfaces or anatomical locations, possibly elucidating on the homogeneity of the meniscal superficial zone structure (E(instantaneous): 3.17-4.12MPa, E(steady-state): 1.47-1.69MPa). Nanomechanical moduli values were approximately an order of magnitude greater than micro-scale testing derived moduli values. These findings validate the structural homogeneity of the meniscal superficial zone, showing that material properties are statistically similar regardless of meniscal surface and region. Understanding the mechanical behavior of meniscal surfaces is imperative to properly design an effective meniscal replacement.  相似文献   
17.
Excessive mechanical loading can lead to matrix damage and chondrocyte death in articular cartilage. Previous studies on chondral and osteochondral explants have not clearly distinguished to what extent the degree and the distribution of cell death are dependent on the presence of an underlying layer of bone. The current study hypothesized that the presence of underlying bone would decrease the amount of matrix damage and cell death. Chondral and osteochondral explants were loaded to 30 MPa at a high rate of loading (approximately 600 MPa/s) or at a low rate of loading (30 MPa/s). After 24 hours in culture, matrix damage was assessed by the total length and average depth of surface fissures. The explants were also sectioned and stained for cell viability in the various layers of the cartilage. More matrix damage was documented in chondral than osteochondral explants for each rate of loading experiment. The total amount of cell death was also less in osteochondral explants than chondral explants. The presence of underlying bone significantly reduced the extent of cell death in all zones in low rate of loading tests. The percentage of cell death was also reduced in the intermediate zone and deep zones of the explant by the presence of the underlying bone for a high rate of loading. This study indicated that the presence of underlying bone significantly limited the degree of matrix damage and cell death, and also affected the distribution of dead cells through the explant thickness. These data may have relevance to the applicability of experimental data from chondral explants to the in situ condition.  相似文献   
18.
Mechanical circulatory support (MCS) devices are blood pumps that support or replace the function of the native heart. It is important to minimize the material stresses in the flexing blood sac or diaphragm in order to increase the duration of support these devices can provide. An axisymmetric finite element model of a pusherplate blood pump was constructed to evaluate the effect of various design parameters on the material stresses in a segmented poly(ether polyurethane urea) seamless blood sac. The design parameters of interest were the sac thickness, pump case wall taper, and radius of the sac between the pusherplate and pump case wall. The analysis involved a quasi-static analysis of the systolic ejection phase of the pump. The finite element solution suggested that the principal stresses and strains increased almost linearly with sac thickness. The pump case wall taper had the largest effect; decreasing the peak principal stresses by approximately 35% when the pump case was straight versus tapered. Lastly, the model demonstrated that the radius of the blood sac between the pusherplate and pump case wall had little or no effect on the magnitude of the blood sac stresses. Therefore, this study suggests that in order to minimize the stresses in a blood sac of a pusherplate blood pump, a straight pump case should be chosen with the thinnest sac.  相似文献   
19.
As a step towards developing a finite element model of the knee that can be used to study how the variables associated with a meniscal replacement affect tibio-femoral contact, the goals of this study were 1) to develop a geometrically accurate three-dimensional solid model of the knee joint with special attention given to the menisci and articular cartilage, 2) to determine to what extent bony deformations affect contact behavior, and 3) to determine whether constraining rotations other than flexion/extension affects the contact behavior of the joint during compressive loading. The model included both the cortical and trabecular bone of the femur and tibia, articular cartilage of the femoral condyles and tibial plateau, both the medial and lateral menisci with their horn attachments, the transverse ligament, the anterior cruciate ligament, and the medial collateral ligament. The solid models for the menisci and articular cartilage were created from surface scans provided by a noncontacting, laser-based, three-dimensional coordinate digitizing system with an root mean squared error (RMSE) of less than 8 microns. Solid models of both the tibia and femur were created from CT images, except for the most proximal surface of the tibia and most distal surface of the femur which were created with the three-dimensional coordinate digitizing system. The constitutive relation of the menisci treated the tissue as transversely isotropic and linearly elastic. Under the application of an 800 N compressive load at 0 degrees of flexion, six contact variables in each compartment (ie., medial and lateral) were computed including maximum pressure, mean pressure, contact area, total contact force, and coordinates of the center of pressure. Convergence of the finite element solution was studied using three mesh sizes ranging from an average element size of 5 mm by 5 mm to 1 mm by 1 mm. The solution was considered converged for an average element size of 2 mm by 2 mm. Using this mesh size, finite element solutions for rigid versus deformable bones indicated that none of the contact variables changed by more than 2% when the femur and tibia were treated as rigid. However, differences in contact variables as large as 19% occurred when rotations other than flexion/extension were constrained. The largest difference was in the maximum pressure. Among the principal conclusions of the study are that accurate finite element solutions of tibio-femoral contact behavior can be obtained by treating the bones as rigid. However, unrealistic constraints on rotations other than flexion/extension can result in relatively large errors in contact variables.  相似文献   
20.
Chronic degeneration of articular cartilage and bone in a rabbit model of post-traumatic osteoarthrosis has been hypothesized to occur due to acute stresses that exceed a threshold for injury. In this study, we impacted the rabbit patellofemoral joint at low and high intensities. High-intensity impacts produced degenerative changes in the joint, such as softening of retropatellar cartilage, as measured by indentation, an increase in histopathology of the cartilage, and an increase in thickness of subchondral bone underlying the cartilage. Low-intensity impacts did not cause these progressive changes. These data suggest that low-intensity impacts produced acute tissue stresses below the injury threshold, while high-intensity impacts produced stresses that exceeded the threshold for disease pathogenesis. This study begins to identify "safe" and "unsafe" ranges of acute tissue stress, using the rabbit patella, which may have future utility in the design of injury prevention devices for the human.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号