首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   70篇
  免费   3篇
  国内免费   3篇
  76篇
  2020年   1篇
  2019年   1篇
  2018年   1篇
  2016年   4篇
  2015年   3篇
  2014年   6篇
  2013年   3篇
  2012年   5篇
  2011年   3篇
  2010年   7篇
  2009年   7篇
  2008年   4篇
  2007年   4篇
  2006年   2篇
  2005年   2篇
  2004年   2篇
  2003年   2篇
  1999年   1篇
  1998年   1篇
  1996年   1篇
  1993年   1篇
  1989年   2篇
  1987年   2篇
  1981年   3篇
  1980年   4篇
  1979年   1篇
  1977年   2篇
  1974年   1篇
排序方式: 共有76条查询结果,搜索用时 15 毫秒
21.
Bats account for 30% of mammal diversity in SE Asia and are potential bioindicators of wider biodiversity impacts resulting from habitat loss and climate change.As existing sampling techniques in the region typically fail to record bats that habitually fly in open areas and at higher altitudes,current inventory efforts are less than comprehensive.Acoustic sampling with bat detectors may help to overcome these limitations for insectivorous bats,but has yet to be tested in mainland SE Asia.To do so,we sampled...  相似文献   
22.
Tetraploid parenchymal rat liver nuclei incorporate about twice as much (3H)dexamethasone as diploid parenchymal nuclei both in vivo and in vitro. This suggests that the ability of hepatic nuclei to incorporate glucocorticoid hormone is influenced by the number of copies of the genome in these nuclei.  相似文献   
23.
24.
25.

Background

Flexible video bronchoscopes, in particular the Olympus BF Type 3C160, are commonly used in pediatric respiratory medicine. There is no data on the magnification and distortion effects of these bronchoscopes yet important clinical decisions are made from the images. The aim of this study was to systematically describe the magnification and distortion of flexible bronchoscope images taken at various distances from the object.

Methods

Using images of known objects and processing these by digital video and computer programs both magnification and distortion scales were derived.

Results

Magnification changes as a linear function between 100 mm (×1) and 10 mm (×9.55) and then as an exponential function between 10 mm and 3 mm (×40) from the object. Magnification depends on the axis of orientation of the object to the optic axis or geometrical axis of the bronchoscope. Magnification also varies across the field of view with the central magnification being 39% greater than at the periphery of the field of view at 15 mm from the object. However, in the paediatric situation the diameter of the orifices is usually less than 10 mm and thus this limits the exposure to these peripheral limits of magnification reduction. Intraclass correlations for measurements and repeatability studies between instruments are very high, r = 0.96. Distortion occurs as both barrel and geometric types but both types are heterogeneous across the field of view. Distortion of geometric type ranges up to 30% at 3 mm from the object but may be as low as 5% depending on the position of the object in relation to the optic axis.

Conclusion

We conclude that the optimal working distance range is between 40 and 10 mm from the object. However the clinician should be cognisant of both variations in magnification and distortion in clinical judgements.  相似文献   
26.

Introduction

We have previously demonstrated that ex vivo inhibition of costimulatory molecules on antigen-pulsed dendritic cells (DCs) can be useful for induction of antigen-specific immune deviation and suppression of autoimmune arthritis in the collagen induced arthritis (CIA) model. The current study evaluated a practical method of immune modulation through temporary systemic inhibition of the costimulatory molecule CD40.

Methods

Mice with collagen II (CII)-induced arthritis (CIA) were administered siRNA targeting the CD40 molecule. Therapeutic effects were evaluated by clinical symptoms, histopathology, Ag-specific T cell and B cell immune responses.

Results

Systemic administration of CD40-targeting siRNA can inhibit antigen-specific T cell response to collagen II, as well as prevent pathogenesis of disease in both a pre- and post-immunization manner in the CIA model. Disease amelioration was associated with suppression of Th1 cytokines, attenuation of antibody production, and upregulation of T regulatory cells.

Conclusions

These studies support the feasibility of transient gene silencing at a systemic level as a mechanism of resetting autoreactive immunity.  相似文献   
27.
Summary An allele giving rise to a polymorphism within the 3 part of the chicken vitellogenin gene was cloned, sequenced, and compared to the previously cloned allele. The polymorphism is formed by a perfect copy of 343 bp from intron 32 in tandem array with a perfect copy of 244 bp from intron 33; this 587-bp element is inserted in a head-to-tail arrangement in intron 33. We propose a mechanism in which an unequal crossing-over resulted in a vitellogenin gene with two exons 33, one of which was subsequently deleted. Thus, intron 33 was enlarged by the tandem repeats without affecting the protein-encoding sequence of the gene. At the boundaries of the repeated elements, two short direct repeats are found that resemble the recombination signals of immunoglobulin genes. They may have had a key role in the formation of the new allele.  相似文献   
28.
The gene encoding the major vitellogenin from chicken has been completely sequenced and its exon-intron organization has been established. The gene is 20,342 base-pairs long and contains 35 exons with a combined length of 5787 base-pairs. They encode the 1850-amino acid pre-peptide of vitellogenin, which is the precursor of the mature yolk proteins, the serine-rich and heavily phosphorylated phosvitin and the lipovitellin. The 217-amino acid phosvitin polypeptide occupies an internal position (residue 1112 through 1328) within the vitellogenin molecule. The 125,000 and 30,000 Mr lipovitellin polypeptides are encoded by the sequences at the N-terminal and the C-terminal sides of the phosvitin section, respectively. The main features of the gene and protein sequences, and the evolutionary implications, are discussed.  相似文献   
29.
30.

Background

Injurious mechanical ventilation (MV) may augment organ injury remote from the lungs. During sepsis, myocardial dysfunction is common and increased endothelial activation and permeability can cause myocardial edema, which may, among other factors, hamper myocardial function. We investigated the effects of MV with injuriously high tidal volumes on the myocardium in an animal model of sepsis.

Methods

Normal rats and intraperitoneal (i.p.) lipopolysaccharide (LPS)-treated rats were ventilated with low (6 ml/kg) and high (19 ml/kg) tidal volumes (Vt) under general anesthesia. Non-ventilated animals served as controls. Mean arterial pressure (MAP), central venous pressure (CVP), cardiac output (CO) and pulmonary plateau pressure (Pplat) were measured. Ex vivo myocardial function was measured in isolated Langendorff-perfused hearts. Cardiac expression of endothelial vascular cell adhesion molecule (VCAM)-1 and edema were measured to evaluate endothelial inflammation and leakage.

Results

MAP decreased after LPS-treatment and Vt-dependently, both independent of each other and with interaction. MV Vt-dependently increased CVP and Pplat and decreased CO. LPS-induced peritonitis decreased myocardial function ex vivo but MV attenuated systolic dysfunction Vt-dependently. Cardiac endothelial VCAM-1 expression was increased by LPS treatment independent of MV. Cardiac edema was lowered Vt-dependently by MV, particularly after LPS, and correlated inversely with systolic myocardial function parameters ex vivo.

Conclusion

MV attenuated LPS-induced systolic myocardial dysfunction in a Vt-dependent manner. This was associated with a reduction in cardiac edema following a lower transmural coronary venous outflow pressure during LPS-induced coronary inflammation.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号