全文获取类型
收费全文 | 243篇 |
免费 | 18篇 |
专业分类
261篇 |
出版年
2022年 | 3篇 |
2021年 | 3篇 |
2019年 | 2篇 |
2018年 | 1篇 |
2017年 | 5篇 |
2016年 | 3篇 |
2015年 | 11篇 |
2014年 | 15篇 |
2013年 | 19篇 |
2012年 | 17篇 |
2011年 | 14篇 |
2010年 | 8篇 |
2009年 | 14篇 |
2008年 | 15篇 |
2007年 | 10篇 |
2006年 | 17篇 |
2005年 | 12篇 |
2004年 | 9篇 |
2003年 | 8篇 |
2002年 | 7篇 |
2001年 | 14篇 |
2000年 | 10篇 |
1999年 | 7篇 |
1998年 | 11篇 |
1997年 | 3篇 |
1996年 | 3篇 |
1995年 | 3篇 |
1994年 | 2篇 |
1993年 | 1篇 |
1989年 | 1篇 |
1988年 | 1篇 |
1987年 | 2篇 |
1984年 | 2篇 |
1983年 | 1篇 |
1982年 | 1篇 |
1981年 | 1篇 |
1979年 | 1篇 |
1976年 | 2篇 |
1971年 | 1篇 |
1967年 | 1篇 |
排序方式: 共有261条查询结果,搜索用时 15 毫秒
11.
12.
Jan AM van Laar Jasper H Kappen Paul LA van Daele P Martin van Hagen 《Arthritis research & therapy》2009,11(2):109-3
Behçet's disease is a complex vasculitis of unknown etiology. Abundant neutrophils suggest the involvement of innate immunity. Cytokines are skewed to the T-helper-1 pattern. Few sterile organs are easily accessible for analysis in Behçet's disease. Cañete and coworkers identify inflamed joints as a feasible model and suggest the involvement of innate immunity in Behçet's disease. 相似文献
13.
Synthesis and characterization of mPEG-PLA prodrug micelles 总被引:6,自引:0,他引:6
Polymeric prodrugs of mPEG-PLA-haloperidol (methoxypoly(ethylene glycol)-b-poly(lactic acid)) can self-assemble into nanoscale micelle-like structures in aqueous solutions. mPEG-PLA-haloperidol was prepared and characterized using 1H and 13C NMR. The conjugation efficiency was found to be 64.8 +/- 21%. Micelles that form spontaneously upon solubilization of the mPEG-PLA and the polymeric prodrugs in water were characterized using a variety of techniques. The mPEG-PLA and prodrug micelles were found to have diameters of 28.73 +/- 1.45 and 49.67 +/- 4.29 nm, respectively, using dynamic light scattering (DLS). The micelle size and polydispersity were also evaluated with cryogenic transmission electron microscopy (cryo-TEM) and were consistent with the DLS results. Cryo-TEM and proton NMR confirmed that the micelles were spherical in shape. DLS was also used to determine the aggregation numbers of the micelles. The aggregation numbers ranged from 351 to 603. The change in aggregation number was dependent on the total drug incorporation into the micelle core. Critical micelle concentrations were determined for the various micelle/drug formulations and found to range from 3 to 14 microg/mL. Finally, drug was incorporated into the micelle core using the conjugate, free drug with a saturated aqueous phase during production, or a combination of both techniques. Drug incorporation could be increased from 3% to 20% (w/w) using the different formulations. 相似文献
14.
The effect of neurotensin on submaximally-stimulated hepatobiliary and pancreatic secretion was studied in 6 healthy subjects. An intravenous infusion of neurotensin 1.4 ± 0.3 pmol/kg/min, designed to reproduce plasma neurotensin immunoreactivity levels within the physiological range, produced a significant increase in pancreatic bicarbonate output. Plasma concentrations of pancreatic polypeptide rose by 83 ± 16 pmol/l and were associated with a small reduction in trypsin, but no significant change in bilirubin outputs. 相似文献
15.
Andrea Vivian Alvarez-Oxiley Noelita Melo de Sousa Jean-Luc Hornick Kamal Touati Gysbert C van der Weijden Marcel AM Taverne Otto Szenci Jean-François Beckers 《Acta veterinaria Scandinavica》2010,52(1):9
Background
The involvement of placental lactogen (PL) in the regulation of foetal growth has been investigated in different species by in vivo immunomodulation techniques. However, when circulating antibodies are present together with the hormone, the procedure for hormonal measurement becomes considerably complex. The aim of this study was the immunoneutralization of bovine placental lactogen (bPL) concentrations in bovine foetal circulation by direct infusion of rabbit anti-bPL purified immunoglobulins (IgG) via a foetal catheter (in vivo study). The ability of a RIA based on guinea pig anti-bPL antiserum, for the measurement of bPL concentrations in samples containing exogenous rabbit anti-bPL immunoglobulins, was also analyzed in in vitro and in vivo conditions. 相似文献16.
Spectrometric studies on stability of tenuazonic acid (TeA) solution in organic solvents 总被引:1,自引:0,他引:1
The stability of tenuazonic acid solution at different temperatures and storage times was studied using methanol, methanol-water
(8:2 v/v), benzene and benzene-acetonitrile (98:2 v/v) as solvents. Solutions were analysed by a spectrometric method TeA
U.V.-spectrum was recorded. Results indicated that the optimum temperature for long-time storage period of tenuazonic acid
solution in any solvent assayed is -20°C. Benzene and benzene-acetonitrile (98:2 v/v) could be advised to make tenuazonic
acid solution which will be stored less than 2 months at 4°C. Methanol and methanolwater (8:2 v/v) are not recommended because
a low stability of TeA solution in this solvents. 相似文献
17.
When designing a nonviral gene delivery system based on polymeric nanoparticles (NPs), it is important to keep in mind obstacles associated with future clinical applications. Simplifying the procedure of NPs production and taking toxicity into account are the most important issues that need to be addressed. Toxicity concerns in clinical trials may be raised when using additives such as cationic polymers/lipids, buffering reagents, and proteins. Therefore, the aim of this study was to simplify the formulation of poly (lactide-co-glycolide) acid NPs by shortening steps such as sonication time and by avoiding the use of additives while preserving its efficiency. NPs (300 nm) were formulated using a modified w/o/w technique with DNA entrapment efficiency of 80%. Once achieving such NPs, formulation parameters such as DNA loading, release kinetics, DNA integrity and bioactivity, uptake by cells, and toxicity were addressed. The NPs were readily taken by several cell lines and were localized mostly in their endo-lysosomal compartments. The NPs did not affect cells viability. Most importantly, transfection studies in COS-7 and Cf2th cells resulted with a 250-fold protein expression levels when compared with the control. These expression levels are higher than ones achieved with more complicated NPs systems, demonstrating the efficiency of our simplified NPs for gene delivery. 相似文献
18.
Bittner O Gal S Pinchuk I Danino D Shinar H Lichtenberg D 《Chemistry and physics of lipids》2002,114(1):81-98
In an attempt to deepen our understanding of the mechanisms responsible for lipoprotein peroxidation, we have studied the kinetics of copper-induced peroxidation of the polyunsaturated fatty acid residues in model membranes (small, unilamellar liposomes) composed of palmitoyllinoleoylphosphatidylcholine (PLPC). Liposomes were prepared by sonication and exposed to CuCl(2) in the absence or presence of naturally occurring reductants (ascorbic acid (AA) and/or alpha-tocopherol (Toc)) and/or a Cu(I) chelator (bathocuproinedisulfonic acid (BC) or neocuproine (NC)). The resultant oxidation process was monitored by recording the time-dependence of the absorbance at several wavelengths. The observed results reveal that copper-induced peroxidation of PLPC is very slow even at relatively high copper concentrations, but occurs rapidly in the presence of ascorbate, even at sub-micromolar copper concentrations. When added from an ethanolic solution, tocopherol had similar pro-oxidative effects, whereas when introduced into the liposomes by co-sonication tocopherol exhibited a marked antioxidative effect. Under the latter conditions, ascorbate inhibited peroxidation of the tocopherol-containing bilayers possibly by regeneration of tocopherol. Similarly, both ascorbate and tocopherol exhibit antioxidative potency when the PLPC liposomes are exposed to the high oxidative stress imposed by chelated copper, which is more redox-active than free copper. The biological significance of these results has yet to be evaluated. 相似文献
19.
Danino AM Harchaoui A Malka G 《Plastic and reconstructive surgery》2003,112(3):925-6; author reply 926-7
20.
Boland JL Corbeij HA Van Der Giessen W Seabra-Gomes R Suryapranata H Wijns W Hanet C Suttorp MJ Buller C Bonnier JJ Colombo A Van Birgelen C Pieper M Mangioni JA Londero H Carere RG Hamm CW Bonan R Bartorelli A Kyriakides ZS Chauhan A Rothman M Grinfeld L Oosterwijk C Serruys PW Cumberland DC 《International journal of cardiovascular interventions》2000,3(4):215-225
AIMS: The BiodivYsio trade mark stent (Biocompatibles Ltd, Farnham, UK) is coated with a phosphorylcholine (PC)-containing copolymer to confer biocompatibility. The SOPHOS (Study Of PHosphorylcholine coating On Stents) study was designed to assess the safety and efficacy of this novel coronary stent and by indirect comparison to indicate equivalence with other formal stent studies. METHODS AND RESULTS: Patients with angina and a single short (#x2A7F;12 mm) de novo lesion in a native coronary artery of >/=2.75 mm diameter were included. A total of 425 patients were allocated in 24 centers. Clinical data were collected at one-, six- and nine-month follow-up. Angiography was performed before and after the stent implantation. In addition, in the first 200 patients (SOPHOS A) angiography was routinely performed at six months. The following 225 patients (SOPHOS B) were merely followed up clinically. The primary end-point of the study, the six-month MACE-rate (MACE = Major Adverse Cardiac Events) was 13.4% (two cardiac death; five Q-wave/nine non-Q-wave myocardial infarctions (MI); nine CABG and 32 target lesion revascularization (TLR), which is similar to the calculated 15% MACE-rate in comparable reference studies. Secondary end-points included among others restenosis at six months in the SOPHOS A population. The target vessel diameter was 2.98 +/- 0.48 mm. Minimal lumen diameter pre/post procedure and at follow-up was 1.00 +/- 0.32, 2.69 +/- 0.37, 1.91 +/- 0.71 mm, respectively. The binary restenosis rate (>/=50% diameter stenosis at follow-up) was 17.7%. CONCLUSION: The coronary BiodivYsio stent is safe and effective as a primary device for the treatment of native coronary artery lesions in patients with stable or unstable angina pectoris. Clinical and angiographic results are in the statistical range of equivalence with comparable studies with other current stents. 相似文献