排序方式: 共有43条查询结果,搜索用时 0 毫秒
41.
42.
Lauren J. Green Stephen H. Kennedy Lucy Mackillop Stephen Gerry Manorama Purwar Eleonora Staines Urias Leila Cheikh Ismail Fernando Barros Cesar Victora Maria Carvalho Eric Ohuma Yasmin Jaffer J. Alison Noble Michael Gravett Ruyan Pang Ann Lambert Enrico Bertino Aris T. Papageorghiou Cutberto Garza Zulfiqar Bhutta Jos Villar Peter Watkinson for the International Fetal Newborn Growth Consortium for the st Century 《PLoS medicine》2021,18(4)
BackgroundGestational hypertensive and acute hypotensive disorders are associated with maternal morbidity and mortality worldwide. However, physiological blood pressure changes in pregnancy are insufficiently defined. We describe blood pressure changes across healthy pregnancies from the International Fetal and Newborn Growth Consortium for the 21st Century (INTERGROWTH-21st) Fetal Growth Longitudinal Study (FGLS) to produce international, gestational age-specific, smoothed centiles (third, 10th, 50th, 90th, and 97th) for blood pressure.Methods and findingsSecondary analysis of a prospective, longitudinal, observational cohort study (2009 to 2016) was conducted across 8 diverse urban areas in Brazil, China, India, Italy, Kenya, Oman, the United Kingdom, and the United States of America. We enrolled healthy women at low risk of pregnancy complications. We measured blood pressure using standardised methodology and validated equipment at enrolment at <14 weeks, then every 5 ± 1 weeks until delivery.We enrolled 4,607 (35%) women of 13,108 screened. The mean maternal age was 28·4 (standard deviation [SD] 3.9) years; 97% (4,204/4,321) of women were married or living with a partner, and 68% (2,955/4,321) were nulliparous. Their mean body mass index (BMI) was 23.3 (SD 3.0) kg/m2. Systolic blood pressure was lowest at 12 weeks: Median was 111.5 (95% CI 111.3 to 111.8) mmHg, rising to a median maximum of 119.6 (95% CI 118.9 to 120.3) mmHg at 40 weeks’ gestation, a difference of 8.1 (95% CI 7.4 to 8.8) mmHg. Median diastolic blood pressure decreased from 12 weeks: 69.1 (95% CI 68.9 to 69.3) mmHg to a minimum of 68.5 (95% CI 68.3 to 68.7) mmHg at 19+5 weeks’ gestation, a change of −0·6 (95% CI −0.8 to −0.4) mmHg. Diastolic blood pressure subsequently increased to a maximum of 76.3 (95% CI 75.9 to 76.8) mmHg at 40 weeks’ gestation. Systolic blood pressure fell by >14 mmHg or diastolic blood pressure by >11 mmHg in fewer than 10% of women at any gestational age. Fewer than 10% of women increased their systolic blood pressure by >24 mmHg or diastolic blood pressure by >18 mmHg at any gestational age. The study’s main limitations were the unavailability of prepregnancy blood pressure values and inability to explore circadian effects because time of day was not recorded for the blood pressure measurements.ConclusionsOur findings provide international, gestational age-specific centiles and limits of acceptable change to facilitate earlier recognition of deteriorating health in pregnant women. These centiles challenge the idea of a clinically significant midpregnancy drop in blood pressure.Lauren Green and colleagues study blood pressure in pregnant women across a range of countries. 相似文献
43.
Hoang-Dung Nguyen So-Hyeon Yoo M. Raheel Bhutta Keum-Shik Hong 《Biomedical engineering online》2018,17(1):180
The study presents a recursive least-squares estimation method with an exponential forgetting factor for noise removal in functional near-infrared spectroscopy data and extraction of hemodynamic responses (HRs) from the measured data. The HR is modeled as a linear regression form in which the expected HR, the first and second derivatives of the expected HR, a short-separation measurement data, three physiological noises, and the baseline drift are included as components in the regression vector. The proposed method is applied to left-motor-cortex experiments on the right thumb and little finger movements in five healthy male participants. The algorithm is evaluated with respect to its performance improvement in terms of contrast-to-noise ratio in comparison with Kalman filter, low-pass filtering, and independent component method. The experimental results show that the proposed model achieves reductions of 77% and 99% in terms of the number of channels exhibiting higher contrast-to-noise ratios in oxy-hemoglobin and deoxy-hemoglobin, respectively. The approach is robust in obtaining consistent HR data. The proposed method is applied for both offline and online noise removal. 相似文献