首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   25篇
  免费   1篇
  2015年   1篇
  2012年   1篇
  2010年   1篇
  2009年   1篇
  2006年   1篇
  2005年   2篇
  1999年   1篇
  1998年   1篇
  1995年   1篇
  1993年   1篇
  1990年   2篇
  1989年   3篇
  1988年   1篇
  1987年   2篇
  1986年   1篇
  1985年   1篇
  1984年   2篇
  1983年   1篇
  1977年   1篇
  1974年   1篇
排序方式: 共有26条查询结果,搜索用时 15 毫秒
11.
Noncoding RNAs have recently been identified as essential components of the nuclear suborganelles called paraspeckles. This finding will facilitate our understanding of the molecular dynamics and physiological role of these enigmatic macromolecular structures.  相似文献   
12.
The objective of this project was to develop and test a new technology for imaging growing joints by means of diffraction-enhanced imaging (DEI) combined with CT and using a synchrotron radiation source. DEI–CT images of an explanted 4-wk-old piglet stifle joint were acquired by using a 40-keV beam. The series of scanned slices was later ‘stitched’ together, forming a 3D dataset. High-resolution DEI-CT images demonstrated fine detail within all joint structures and tissues. Striking detail of vasculature traversing between bone and cartilage, a characteristic of growing but not mature joints, was demonstrated. This report documents for the first time that DEI combined with CT and a synchrotron radiation source can generate more detailed images of intact, growing joints than can currently available conventional imaging modalities.Abbreviations: DEI, diffraction-enhanced imagingDiffraction-enhanced imaging (DEI) is a biomedical imaging technique that, compared with conventional radiography, generates very detailed images with more edge contrast but deposits a lower radiation dose to the object. DEI generates enhanced contrast both from absorption, the process involved in conventional radiography, and from of X-ray refraction, a process that harnesses photons that otherwise typically are imperceptibly diffracted.4 The DEI technique collects information from X-rays that are refracted as they pass through tissues that have different refractive indices as it almost completely removes diffracted X-rays. In comparison, conventional radiography produces images from X-rays that are attenuated by the tissues through which they pass, but X-rays that are refracted within those same tissues confound, rather than clarify, image contrast. The creation of contrast from the refraction of X-rays, rather than exclusively from absorption, yields images that display more detail with clearer distinction between tissue interfaces. Refraction-based imaging can reveal tiny structures that are transparent to X-ray attenuation but have sufficient variation in density to produce refraction contrast. Furthermore, refraction-based imaging decreases the required radiation dose.21To obviate the superimposing effects in a 2-dimensional DEI refraction image, we considered that combining CT with DEI would yield images with even greater clarity. CT allows a 3D representation of the sample, such that contrast from features at different depths are no longer superimposed on one another but can be separated and viewed as independent structures. Although this advantage is valuable in traditional absorption imaging, the additional features that provide contrast in a refraction-based image enhance the value of CT. Combining DEI technology, which is capable of imaging soft-tissue detail, with CT, which allows segregation of the contrast images at different depths, overcomes limitations of conventional X-ray imaging, namely lack of distinction of soft tissues and 2-dimensionality. As we report here, DEI combined with CT and a synchrotron-generated X-ray source yields 3D images of growing joint tissues at a resolution on the order of micrometers, which is much higher than can be generated using conventional imaging techniques.A synchrotron radiation source was required for the development of DEI because a synchrotron currently is the only source capable of providing an intensely brilliant light (millions of times brighter than sunlight and conventional X-ray sources), is highly collimated (light rays in the beam remain parallel with negligible dispersion over distance), can be made to be monochromatic (having a single wavelength), and can be tuned precisely to an array of energy ranges. The Canadian Light Source (www.lightsource.ca), which began operations in 2005, is one of only 47 synchrotron facilities worldwide and the only such facility in Canada. Although nonsynchrotron sources of X-rays for DEI–CT are conceivable,16,18 such technology requires considerable image-acquisition time. Regardless, the quality of images generated by using synchrotron technology likely would remain the standard with which any new nonsynchrotron DEI–CT technological innovations would be compared.14Despite refinements in medical imaging, conventional radiography, CT scanning, and MRI still are insufficient to discern fine details, particularly in growing joints in which soft tissues (including cartilage) predominate and change with physiologic growth. The impetus for the current research was to develop an imaging technique that better demonstrated normal joint characteristics during growth and, in the future, could be applied to pathologic joints for experimental research and eventually clinical applications. In particular, we were motivated by a need to more effectively and reliably image growing joints affected by arthritis, a disease associated with alterations of bone and cartilage growth, tissue morphology and vascularity. Childhood arthritis research likely will benefit from having an improved imaging technique to aid in early diagnosis, monitor disease progression, and assess responses to therapies. The long-term outcomes of childhood arthritis are improved with early diagnosis and prompt and effective response to treatment interventions. Clinical and laboratory-based indicators of inflammation are not always adequate to detect and monitor subclinical intraarticular inflammation which, as with overt disease, can lead to progressive joint damage. Imaging can augment clinical and laboratory assessment of arthritis activity, but even the most sensitive currently available modalities are unable to detect all joint pathology.In juvenile arthritis, joint-imaging outcomes are difficult to evaluate because variations associated with normal growth cannot always be easily discerned from variations induced by the disease. Conventional radiography tends to detect advanced joint damage that has affected bone, but cartilage can be assessed only indirectly, and soft tissue abnormalities cannot be fully evaluated. Consequently, conventional radiography has insufficient sensitivity and specificity to be considered useful for diagnosing or monitoring children with inflammatory joint disease.6,20 MRI, which evaluates both soft tissues and osteochondral structures, can be used to detect cartilage loss, bone erosions, and synovial hypertrophy in children and adolescents, and contrast-enhanced MRI detects active synovitis.1,10 However, standardized approaches to acquire and interpret MRI data are not established for children in general and, in particular, for children with arthritis;12,15 it is not always clear, for example, if observed thinning of cartilage is physiologic or pathologic. Furthermore, although MRI is more sensitive than conventional radiography, MRI too has limited precision in detecting fine structures and pathologic changes; a clinical MRI has less than 50% sensitivity in detecting cartilage damage that subsequently is seen arthroscopically.8,13CT offers another option for joint visualization, given that it provides high-resolution, 3D images of bone from any angle. Despite its high spatial resolution, however, CT cannot match MRI''s soft-tissue contrast resolution, because CT provides negligible variability of attenuation coefficients of soft tissues so attenuation is nearly the same for cartilage, muscles, and ligaments. Furthermore, CT''s value is offset by the necessity for radiation exposure, a particular concern in the pediatric population. Therefore, for joint research and clinical applications, each of the conventional imaging techniques currently available has limitations. A safe, higher resolution imaging system that generates good contrast for all joint structures is required.Because the DEI technique initially was developed by using a synchrotron light source, we similarly used synchrotron technology in the current experiments. In contrast to conventional X-ray tubes, a synchrotron generates light by using radiofrequency waves and electromagnets to energize and accelerate electrons, thus producing brilliant, highly focused light from the entire wavelength spectrum, including X-rays. For the development and evaluation of DEI–CT imaging of joints, we chose to use healthy commercial piglet stifle joints because porcine stifle joints are anatomically similar to human knees.5 In addition, pigs grow quickly, reaching skeletal maturity at the distal femur and proximal tibia in 20 mo,19 thus allowing for the use of the pig as a model to study growth patterns in normal and disease states in a relatively short time period. The current study aimed to develop and test a new technology for imaging growing joints by using DEI combined with CT and a synchrotron radiation source. This report is the first to document the application of DEI–CT for imaging intact, growing joints.  相似文献   
13.
The authors studied the influence of synthetic polyelectrolytes of polyacrylic acid and poly-2-methyl-5-vinylpyridine and of complete Freund's adjuvant on the migration of stem cells and B-lymphocytes from mouse bone marrow. The stem cell count was evaluated by the number of splenic colonies; as to B-cell migration--it was assessed by the accumulation of the antibody-forming cells forming from B-lymphocytes migrating in the spleen in the transfer of fixed number of T-lymphocytes. As revealed the synthetic substances under study intensified the migration of stem cells and of B-lymphocytes to a much greater extent than Freund's adjuvant. The mechanisms of the influence of the adjuvants used on cell migration processes are discussed.  相似文献   
14.
Theoretical considerations have shown that the five possible overlapping reading-frame configurations differ significantly in their coding flexibility and thus in their information content (Siegel and Fitch 1980; Smith and Waterman 1980). Contrary to expectation, the overlapping frame configuration allowing the greatest coding flexibility is rarely seen, whereas one of the most constraining is common. We point out here that this overlapping reading-frame paradox and an observed but unexplained preference in coding regions for a pyrimidine-purine at codon boundaries (Shepherd 1981; Jones and Kafatos 1982; Smith et al. 1983) are intimately linked. The codon boundary preference, which may be related to translation efficiency or accuracy, places constraints on the evolution of overlapping coding regions. These considerations may help identify actual coding regions in DNA sequences. We have analyzed five sequenced (enteric) bacterial insertion sequences for codon boundary incidences and reading-frame configurations and find that they are consistent with these proposed constraints.   相似文献   
15.
We introduce here a simple approach for rapidly determining restriction maps for a number of regions of a genome; this involves "anchoring" a map with a rare restriction site (in this case the seldom-cutting EagI) followed by partial digestion of a frequent-cutting enzyme (e.g., Sau 3A). We applied this technology to five species of the Anopheles gambiae complex. In a single Southern blot we obtained about a 15-kb restriction map each for the mtDNA, rRNA gene, and a scnDNA region for each of five species. Phylogenetic analyses of these regions yield trees at odds with the more traditional chromosome inversion-based trees. The value of the approach for systematic purposes is the ease with which several large, independent regions of the genome can be quickly assayed for molecular variation.   相似文献   
16.
Effects of crambin on the phospholipase activity, lipid peroxidation and structure of mitochondrial membranes have been investigated. Crambin has been shown to inhibit lipid peroxidation and phospholipase activity induced by Ca2+ and freezing-thawing of mitochondria. As shown by ESR studies, these effects are based on the ability of crambin to cause changes in mitochondrial membrane structure.  相似文献   
17.
Evolutionary relatedness of some primate models of Plasmodium   总被引:1,自引:0,他引:1  
Primate--and, specifically, monkey--malaria infections are commonly used for understanding the pathology of and immune response to the human disease because they are thought to resemble most closely the host-parasite relationship found in humans. Plasmodium cynomolgi is used extensively as a model for the human parasite, P. vivax, and P. knowlesi is used primarily as a model for the development of erythrocytic-stage vaccines. Both of these simian parasites can naturally infect man, resulting in mildly symptomatic episodes of the disease. The phylogenetic relationship between these two simian parasites and previously characterized Plasmodium species, including P. vivax, was examined by comparison of the asexually expressed small- subunit ribosomal RNA genes. Our analysis confirmed that P. vivax is most closely related to P. cynomolgi and that it remains an appropriate model of the human pathogen. Furthermore, with P. knowlesi and P. fragile, these two species form a group of closely related species, distant from other Plasmodium species. What is considered to be the most ancient of the human malaria pathogens, P. malariae, was also included in the analysis and does not group at all with other simian or human parasites.   相似文献   
18.

Background  

High throughput microarray analyses result in many differentially expressed genes that are potentially responsible for the biological process of interest. In order to identify biological similarities between genes, publications from MEDLINE were identified in which pairs of gene names and combinations of gene name with specific keywords were co-mentioned.  相似文献   
19.
In a recent study, we reported that the combined average mutation rate of 10 di-, 6 tri-, and 8 tetranucleotide repeats in Drosophila melanogaster was 6.3 x 10(-6) mutations per locus per generation, a rate substantially below that of microsatellite repeat units in mammals studied to date (range = 10(-2)-10(-5) per locus per generation). To obtain a more precise estimate of mutation rate for dinucleotide repeat motifs alone, we assayed 39 new dinucleotide repeat microsatellite loci in the mutation accumulation lines from our earlier study. Our estimate of mutation rate for a total of 49 dinucleotide repeats is 9.3 x 10(-6) per locus per generation, only slightly higher than the estimate from our earlier study. We also estimated the relative difference in microsatellite mutation rate among di-, tri-, and tetranucleotide repeats in the genome of D. melanogaster using a method based on population variation, and we found that tri- and tetranucleotide repeats mutate at rates 6.4 and 8.4 times slower than that of dinucleotide repeats, respectively. The slower mutation rates of tri- and tetranucleotide repeats appear to be associated with a relatively short repeat unit length of these repeat motifs in the genome of D. melanogaster. A positive correlation between repeat unit length and allelic variation suggests that mutation rate increases as the repeat unit lengths of microsatellites increase.   相似文献   
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号