首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   26篇
  免费   0篇
  2012年   3篇
  2011年   1篇
  2010年   2篇
  2009年   1篇
  2008年   2篇
  2007年   2篇
  2006年   1篇
  2005年   1篇
  2004年   3篇
  2001年   1篇
  2000年   1篇
  1997年   1篇
  1996年   1篇
  1995年   1篇
  1994年   1篇
  1992年   1篇
  1983年   1篇
  1977年   1篇
  1956年   1篇
排序方式: 共有26条查询结果,搜索用时 359 毫秒
21.
Non-aqueous phase liquid (NAPL) contaminants comprised of polycyclic aromatic hy drocarbons (PAHs) can be detected using fluorescence spectroscopic methods. Dense non-aqueous phase liquid (DNAPL) contaminant source zones can be delineated us ing commercially available cone penetrometer (CPT)devices by detecting commingled oils fuels, and naturally occurring organic materials entrained by DNAPLs and carried to depths below the water table. It has been demonstrated that commercially avail able CPT based fluorescence detection systems can be ranked based on how effectively their excitation source wavelengths induce fluorescence using excitation emission ma trices (EEMs). Several neat NAPLs and dilutions with selected DNAPLs were analyzed for specific fluorescence characteristics to determine the optimal excitation source for site characterization efforts. A comprehensive spectral library and corresponding opti mization matrix were generated for complex petroleum mixtures. Based onfield results documenting successful indirect CPT fluorescence detection of a DNAPL source zone, aviation and dieselfuels were selected from this library, diluted with chlorinated sol vents, and evaluated for fluorescence characteristics. Dilution of these complex NAPL mixtures led to changes in the corresponding EEMs. The optimal excitation source for aviationfuel remained relatively constantf or each dilution. However, sensitivityf or each of the commercially available CPT excitation sources was strongly dependent on diesel concentration, whereby higher energy (lowerwavelength) sources yielded improved sen-sitivityfor lower concentrations. Since field concentrations can be highly variable, these observations support the need for multiple wavelength excitation sources for optimal detection capabilities, particularly when diesel fuel ispresent.  相似文献   
22.
The surface morphology of Entamoeba histolytica trophozoites of HM 1:IMSS (axenic and monoxenic) and HK9 (axenic) strains cultured on plastic and MDCK cell substrates was examined using scanning electron microscopy (SEM). The conditions for processing trophozoites were determined by comparing the SEM observations with the morphology of living amebas examined by light microscopy. The most frequent surface differentiations in all the amebas observed with SEM were lobopodia. Round cytoplasmic projections were found in approximately half of the axenic amebas. Endocytic stomas and filopodia were more common in monoxenic cultures while the uroid was found in only 2–8% of all examined amebas. The basal surfaces of the trophozoites, involved in both attachment and cytolysis, showed no unusual features, except for the presence of a small number of short filopodia at the outer edge. No differences were found in the morphology of amebas grown on artificial and natural substrates. These observations demonstrate that there are significant quantitative differences in the surface morphology of cultured trophozoites of different strains of E. histolytica and that association with bacteria produces an increase in the relative number of surface specializations of the parasite.  相似文献   
23.
Meliwillea bivea gen.n., sp.n. is the only known stingless bee genus endemic to Central America. External morphology and male genitalia show affinity of Meliwillea with Scaptotrigona . Its plesiomorphies and current sympatry with Scaptotrigona suggest Meliwillea is relictual and diverged in montane habitat during the Tertiary, predating the Pleistocene connection between Central and South America which allowed immigration by Scaptotrigona . Addition of Meliwillea to the list of Neotropical genera changes the phylogenetic position of Nannotrigona , making it sister to Paratrigona instead of Scaptotrigona .  相似文献   
24.
Commercially available cone penetrometer (CPT)fluorescence based sensor platforms have been used to detect non-aqueous phase liquids (NAPLs), such as petroleum oils and lubricants, in situf or more than a decade. These approaches have also been used to detect dense non-aqueous phase liquid (DNAPL) source zones by detecting commingled oilsfuels, and naturally occurring organic materials entrained by DNAPLs and carried to depths below the water table. Several neat NAPLs and mixtureswere added to various soil types and analyzedfor specific fluorescence characteristics to determine the optimal excitation source for site characterization efforts. Using excitationlemission matrices (EEMs), we demonstrate that an optimized excitation wavelength can be determinedfor specific fiuowphores within the NAPL mixtures, and that available systems can be ranked based on the specific contaminant and site soil types. An optimal excitation wavelength yields the maximum fluorescence within an EEM spectrum. We ranked commercially available cone penetrometer fluorescence detection systems according to the potential for ease of detection based on maximum fluorescence response. When soils were added tocomplexNAPLmixtures,analytefluorescence emissionwasattenuatedinpreferential portions of the EEM, leading to differences in the optimal excitation source wavelength. Furthermore, impure silica-containing minerals impact the emission signal, potentially leading to incorrect conclusionsf or several commercially available systems. Our find ings suggest that afrequency-agile (e.g., tunable excitation source) probe system would be superior to any other system commercially available, provided the system would be relatively easy to operate and would have rapid in-situ EEM generating capabilitiesfo r optimization in the field.  相似文献   
25.
Vectors of cutaneous leishmaniasis in north-central Venezuela   总被引:1,自引:0,他引:1  
Abstract. An entomological survey was undertaken from January 1991 to February 1992 in El Ingenio, Miranda State, Venezuela, an endemic area of cutaneous leishmaniasis: prevalence of 10.7 cases per 100,000 inhabitants.
A total of 4863 female sandflies (Phlebotominae) of fourteen species were collected in Shannon traps, then dissected and examined for leishmanial infections.
Lutzomyia ovallesi (85.4%) and Lu. gomezl (11.2%) were the predominant anthropophilic species of sandfly. Fifty-one (1.19%) Lu. ovallesi and two(0.47%) Lu. gomezi had natural infection with Leishmania promastigotes. Identification of the parasites was done by using the polymerase chain reaction (PCR) and DNA hybridization. Two isolates from Lu. gomezi and forty-nine from Lu. ovallesi were typed as Leishmania braziliensis and three of the latter reacted with Le. mexicana also. This is the first report of Lu. gomezi with parasites typed as Le. braziliensis.
We concluded that Lu. ovallesi is the primary vector of cutaneous leishmaniasis in the north-central area of Venezuela and Lu. gomezi should be regarded as an additional vector.  相似文献   
26.
Fluorescence has been demonstrated to be a viable method for detecting non-aqueous phase liquid (NAPL) contaminants comprised of polycyclic aromatic hydrocarbons (PAHs). Commercially available cone penetrometer (CPT)induced fluorescence based sensor platforms can be used to detect NAPLs such as petroleum oils and lubricants in-situ. In addition, these approaches can be used to detect dense non-aqueous phase liquid (DNAPL) source zones by detecting commingled oils, fuels, and naturally oc curring organic materials entrained by or in solution with DNAPLs and carried to depths below the water table. The currently available CPT-based fluorescence systems are typically restricted to a single wavelength excitation source, each demonstrating specific advantages and disadvantages with respect to detection capabilities for partic ular fluorophores. Several neat NAPLs and mixtures were analyzedfor specificfluores-cence characteristics to determine the optimal excitation source for site characterization efforts. Commercially available cone penetrometer based fluorescence detection systems were ranked according to the potential for likelihood of detection. Our work demon strates that an optimal range of excitation wavelength can be determined for specific fluorophores within NAPL mixtures, and that available systems can be ranked based on the specific contaminant and site characteristics. We have identified optimal excitation sourcesfor a number of common NAPL mixtures, including petroleum-basedfuels and a lubricant mixed with a chlorinated solvent.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号