首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   373篇
  免费   5篇
  国内免费   13篇
  2014年   1篇
  2013年   21篇
  2012年   1篇
  2011年   67篇
  2010年   22篇
  2009年   19篇
  2008年   14篇
  2007年   5篇
  2006年   3篇
  2005年   4篇
  2004年   4篇
  2003年   7篇
  2002年   2篇
  2001年   51篇
  2000年   94篇
  1999年   1篇
  1998年   15篇
  1997年   20篇
  1996年   26篇
  1995年   2篇
  1994年   2篇
  1993年   1篇
  1991年   3篇
  1990年   1篇
  1987年   1篇
  1981年   1篇
  1974年   1篇
  1967年   1篇
  1930年   1篇
排序方式: 共有391条查询结果,搜索用时 31 毫秒
121.

Background

Studies on the relationship between occlusal problems and the spine are of increasing interest. In this study, we monitored the sEMG activity of masticatory, neck, and trunk muscles during the treatment of scoliosis in young patients, and compared the data with a control of untreated group.

Subjects and methods

Twelve white Caucasian patients (nine males and three females; mean age of 8.0 ± 1.5 years) with scoliosis and Class I occlusion (without crowding) were included in this study (study group). Fifteen healthy subjects (nine males and six females; mean age of 9.5 ± 0.8 years) were recruited as control group. The subjects were visited before they underwent the treatment of scoliosis, as well as after 3 (T1) and 6 months (T2) of their treatment for scoliosis. The patients were instructed to wear the device during sleep and during the day, according to the protocol given by their orthopedic.

Results

The treated group showed statistically significant changes in the sEMG activity of masticatory, neck, and trunk muscles, both at rest and during MVC of the mandible with respect to T0. The masseter and the anterior temporalis showed a significant improvement in the asymmetry index from T0 to T2. On the other hand, subjects in the control group did not register much change.

Conclusion

Our findings suggest that the use of a functional device for the treatment of scoliosis induces a significant reduction in the asymmetry index of the trunk muscles, as well as a significant increase in the contractility of masticatory muscles.  相似文献   
122.

Objective

Previous studies have demonstrated that ankle muscle fatigue alters postural sway. Our aim was to better understand postural control mechanisms during upright stance following plantar flexor fatigue.

Method

Ten healthy young volunteers, 25.7 ± 2.2 years old, were recruited. Foot center-of-pressure (CoP) displacement data were collected during narrow base upright stance and eyes closed (i.e. blindfolded) conditions. Subjects were instructed to stand upright and as still as possible on a force platform under five test conditions: (1) non-fatigue standing on firm surface; (2) non-fatigue standing on foam; (3) ankle plantar flexor fatigue, standing on firm surface; (4) ankle plantar flexor fatigue, standing on foam; and (5) upper limb fatigue, standing on firm surface. An average of the ten 30-s trials in each of five test conditions was calculated to assess the mean differences between the trials. Traditional measures of postural stability and stabilogram-diffusion analysis (SDA) parameters were analyzed.

Results

Traditional center of pressure parameters were affected by plantar flexor fatigue, especially in the AP direction. For the SDA parameters, plantar flexor fatigue caused significantly higher short-term diffusion coefficients, and critical displacement in both mediolateral (ML) and anteroposterior (AP) directions. Long-term postural sway was different only in the AP direction.

Conclusions

Localized plantar flexor fatigue caused impairment to postural control mainly in the Sagittal plane. The findings indicate that postural corrections, on average, occurred at a higher threshold of sway during plantar flexor fatigue compared to non-fatigue conditions.  相似文献   
123.
Muscle fatigue may be a precursor to workplace musculoskeletal disorders, with the low back resulting in the most frequently injured body part. Work/rest ratios have an effect on fatigue due to the amount of rest allowance provided following muscle contraction. This study explored various work/rest ratios by electrically stimulating rat medial longissimus muscles. A 3 V stimulus with 0.2 ms pulse duration was applied at a frequency of 30 Hz. There were four stimulation groups consisting of the following duty cycles (DC) and cycle times (CT): DC25%:CT20s, DC25%:CT280s, DC75%:CT20s, and DC75%:CT180s. Muscle fatigue was measured as a decrease in M-wave amplitude and area, and an increase in M-wave duration. The results indicated that fatigue occurred immediately in each of the groups. The higher duty cycle and shorter cycle time group resulted in significantly greater fatigue than the lower duty cycle and longer cycle time group, as measured by increased M-wave amplitude and area. A longer M-wave duration was observed in the high duty cycle long cycle time group. This suggests that the combination of low duty cycle and long cycle times leads to less fatigue. In high duty cycle scenarios, short cycle times result in less fatigue.  相似文献   
124.
Recent studies indicate that rotator cuff (RC) muscles are recruited in a reciprocal, direction-specific pattern during shoulder flexion and extension exercises. The main purpose of this study was to determine if similar reciprocal RC recruitment occurs during bench press (flexion-like) and row (extension-like) exercises. In addition, shoulder muscle activity was comprehensively compared between bench press and flexion; row and extension; and bench press and row exercises. Electromyographic (EMG) activity was recorded from 9 shoulder muscles sites in 15 normal volunteers. All exercises were performed at 20, 50 and 70% of subjects’ maximal load. EMG data were normalized to standard maximal voluntary contractions. Infraspinatus activity was significantly higher than subscapularis during bench press, with the converse pattern during the row exercise. Significant differences in activity levels were found in pectoralis major, deltoid and trapezius between the bench press and flexion exercises and in lower trapezius between the row and extension exercises. During bench press and row exercises, the recruitment pattern in each active muscle did not vary with load. During bench press and row exercises, RC muscles contract in a reciprocal direction-specific manner in their role as shoulder joint dynamic stabilizers to counterbalance antero-posterior translation forces.  相似文献   
125.
Postural reactions in healthy individuals in the seated position have previously been described and have been shown to depend on the direction of the perturbation; however the neck response following forward and backward translations has not been compared. The overall objective of the present study was to compare neck and trunk kinematic, kinetic and electromyographic (EMG) stabilization patterns of seated healthy individuals to forward and backward translations. Ten healthy individuals, seated on a chair fixed onto a movable platform, were exposed to forward and backward translations (distance = 0.15 m, peak acceleration = 1.2 m/s2). The head and trunk kinematics as well as the EMG activity of 16 neck and trunk muscles were recorded. Neck and trunk angular displacements were computed in the sagittal plane. The centers of mass (COMs) of the head (HEAD), upper thorax (UPTX), lower thorax (LOWTX) and abdomen (ABDO) segments were also computed. Moments of force at the C7-T1 and L5-S1 levels were calculated using a top-down, inverse dynamics approach. Forward translations provoked greater overall COM peak displacements. The first peak of moment of force was also reached earlier following forward translations which may have played a role in preventing the trunk from leaning backwards. These responses can be explained by the higher postural threat imposed by a forward translation.  相似文献   
126.
The purpose of this study was to assess the reproducibility of fascicle length (FL) and pennation angle (PA) of gastrocnemius medialis (GM) muscle during running in vivo. Twelve male recreational long distance runners (mean ± SD; age: 24 ± 3 years, mass: 76 ± 7 kg) ran on a treadmill at a speed of 3.0 m/s, wearing their own running shoes, for two different 10 min sessions that were at least 2 days apart. For each test day 10 acceptable trials were recorded. Ankle and knee joint angle data were recorded by a Vicon 624 system with three cameras operating at 120 Hz. B-mode ultrasonography was used to examine fascicle length and pennation angle of gastrocnemius medialis muscle. The ultrasound probe was firmly secured on the muscle belly using a lightweight foam fixation. The results indicated that fascicle length and pennation angle demonstrated high reproducibility values during treadmill running both for within and between test days. The root mean square scores between the repeated waveforms of pennation angle and fascicle length were small (∼2° and ∼3.5 mm, respectively). However, ∼14 trials for pennation angle and ∼9 trials for fascicle length may be required in order to record accurate data from muscle architecture parameters. In conclusion, ultrasound measurements may be highly reproducible during dynamic movements such as treadmill running, provided that a proper fixation is used in order to assure the constant location and orientation of the ultrasound probe throughout the movement.  相似文献   
127.
To evaluate the time-course of stretching-induced changes in mechanical properties of the muscle-tendon unit (MTU), 11 participants (age 22 ± 1 yr; body mass 77 ± 5 kg; stature 1.78 ± 0.05 m; mean ± SD) underwent tetanic electrical stimulations of the medial gastrocnemius muscle before and after (up to 2 h) stretching administration. During contractions, surface electromyogram (EMG), mechanomyogram (MMG) and force were recorded simultaneously. From MMG, peak-to-peak (p–p) and root mean square (RMS) were calculated during the on-phase and plateau phase of tetanic contraction, respectively. After stretching: (i) no differences were found in EMG parameters; (ii) MMG p–p and slope decreased (−16% and −10%, respectively; P < 0.05) and remained depressed for the entire recovery period; (iii) MMG RMS increased (+20%; P < 0.05), returning to pre-stretching values within 15 min; and (iv) peak force (pF), with its first (dF/dt) and second (d2F/dt2) derivative, decreased significantly by 32%, 35% and 54%, respectively, and remained depressed for the entire recovery period. The lack of MMG p–p and pF recovery could be ascribable to a reduced muscle force generating capacity due to persisting changes in viscoelastic characteristics of series elastic components. The early return of MMG RMS to pre-stretching values suggests that changes in viscoelastic parallel components recovered after few minutes.  相似文献   
128.
The aim of this study was to explore the electromyographic, kinetic and kinematic patterns during a partially restricted sit-to-stand task in subjects with and without Parkinson’s disease (PD). If the trunk is partially restricted, different behavior of torques and muscle activities could be found and it can serve as a reference of the deterioration in the motor performance of subjects with PD. Fifteen subjects participated in this study and electromyography (EMG) activity of the tibialis anterior (TA), soleus (SO), vastus medialis oblique (VMO), biceps femoris (BF) and erector spinae (ES) were recorded and biomechanical variables were calculated during four phases of the movement. Subjects with PD showed more flexion at the ankle, knee and hip joints and increased knee and hip joint torques in comparison to healthy subjects in the final position. However, these joint torques can be explained by the differences in kinematic data. Also, the hip, knee and ankle joint torques were not different in the acceleration phase of movement. The use of a partially restricted sit-to-stand task in PD subjects with moderate involvement leads to the generation of joint torques similar to healthy subjects. This may have important implications for rehabilitation training in PD subjects.  相似文献   
129.
130.
云南含笑天然居群的表型多样性分析   总被引:3,自引:0,他引:3  
为揭示云南含笑天然居群表型变异程度和变异规律,以云南昆明地区天然分布的云南含笑为研究对象,调查了6个居群180个单株的14个表型性状,采用巢式方差分析、变异系数、相关分析、Shannon-Weaver多样性指数分析和聚类分析等方法,分析了居群间和居群内表型多样性.结果表明:(1)云南含笑表型性状在居群间和居群内存在极其丰富的多样性,14个表型性状平均表型分化系数(24.38%)小于居群内变异(75.62%),居群内变异是表型变异的主要来源;14个表型性状的变异系数(CV)在16.20%~60.11%之间,表明云南含笑居群内表型性状离散程度较高.(2)对云南含笑各居群的Shannon-Weaver指数分析表明,云南含笑各居群具有丰富的多样性,总体表型多样性指数为1.772.(3)利用居群间欧氏距离进行的UPGMA聚类分析结果表明,云南含笑6个天然居群可以聚为3类,而且表型性状并没有严格依地理距离而聚类.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号