排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
Chungsying Lu Kwotsair Chang Shihchieh Hsu 《World journal of microbiology & biotechnology》2004,20(2):185-192
A mathematical model that incorporates mass transfer process and biofilm reactions is presented to predict the performance of a trickle-bed air biofilter (TBAB) for treating toluene (T) and acetone (ACE) mixtures. The model consists of a set of mass balance equations for T, ACE and oxygen in the bulk gas phase and within the biofilm. The gas phase T and ACE concentrations predicted by the model were in good agreement with the measured data available in a previous study. The important parameters were evaluated in the sensitivity analysis to determine their respective effects on the model performance. Four parameters were identified as strongly influencing the model performance, the surface area of the biofilm per unit volume of packing material (A
S), the empty-bed residence time (EBRT), the maximum specific growth rate of microorganism (
m), and the microbial yield coefficient (Y). A practical application of the model to derive the performance equation of TBAB is also given. 相似文献
2.
Chang S Lu C Hsu S Lai HT Shang WL Chuang YS Cho CH Chen SH 《Bioresource technology》2011,102(2):1028-1034
This study applied a pilot-scale trickle-bed air biofilter (TBAB) system for treating waste gas emitted from the breather vent of a vertical fixed roof storage tank containing p-xylene (p-X) liquid. The volatile organic compound (VOC) concentration of the waste gas was related to ambient temperature as well as solar radiation, peaking at above 6300 ppmv of p-X and 25000 ppmv of total hydrocarbons during the hours of 8 AM to 3 PM. When the activated carbon adsorber was employed as a VOC buffer, the peak waste gas VOC concentration was significantly reduced resulting in a stably and efficiently performing TBAB system. The pressure drop appeared to be low, reflecting that the TBAB system could be employed in the prolonged operation with a low running penalty. These advantages suggest that the TBAB system is a cost-effective treatment technology for VOC emission from a fixed roof storage tank. 相似文献
3.
The performance of trickle-bed air biofilter (TBAB) for the removal of isopropyl alcohol (IPA) was evaluated in concentrations varying from 100 to 500 ppmv and at empty-bed residence time (EBRT) varying from 20 to 90 s. Nearly complete IPA removal could be achieved for influent carbon loading between 6 and 88 g/m3·h. The TBAB appears efficient for controlling IPA emission under low-to-high carbon loading conditions. Carbon recoveries of 95-99% were achieved demonstrating the accuracy of results. Applicable operating conditions of TBAB for controlling IPA emission were suggested. 相似文献
4.
Summary Three laboratory-scale water pipe systems were set up to study the effects of adding two levels of acetic acid (10 and 50
μg acetate eq-C l−1) on the bacterial regrowth in water pipes. The results of the water pipe test showed that nearly all carbon in the acetic
acid could be readily utilized by bacteria and resulted in an increase in biomass concentration. The maximum heterotrophic
plate counts in biofilm were equal to 3.5 × 104, 8.9 × 105 and 2.9 × 107 c.f.u. cm−2 while the maximum heterotrophic plate counts of free bacteria were equal to 1.2 × 103, 5.0 × 103 and 6.8 × 104 c.f.u. ml−1 for the blank and with addition of 10 and 50 μg acetate eq-C l−1. These results showed that addition of acetic acid to drinking water has a positive effect on the assimilable organic carbon
content of drinking water and bacterial regrowth in the distribution system. This effect is enhanced with addition of high-level
acetic acid. Batch tests were also conducted using water samples collected from a Taiwanese drinking water distribution system.
The bacterial regrowth potentials of the blank were equal to 4.3 × 103, 1.5 × 104, 4.9 × 104 and 7.5 × 104 c.f.u. ml−1 for water samples collected from treatment plant effluent, commercial area, mixed area, and residential area, respectively.
These results showed that the biological stability of drinking water is the highest in treatment plant effluent, followed
by distributed water of the commercial area, distributed water of the mixed area, and then the distributed water of residential
area. 相似文献
5.
A model for treating isopropyl alcohol and acetone mixtures in a trickle-bed air biofilter 总被引:2,自引:0,他引:2
A mathematical model that incorporates mass transfer process and biofilm reactions is presented to predict the performance of a trickle-bed air biofilter (TBAB) for treating isopropyl alcohol (IPA) and acetone (ACE) mixtures. The model consists of a set of mass balance equations for IPA, ACE and oxygen in the bulk gas phase and within the biofilm. The effluent gas phase IPA and ACE concentrations predicted by the present model were in good agreement with the measured data available in a previous study. The important parameters were evaluated by sensitivity analysis to determine their respective effects on model performance. Four parameters were identified that strongly influenced model performance: surface area of the biofilm per unit volume of packing material (AS), empty-bed residence time (EBRT), maximum specific growth rate of microorganism (μm), and microbial yield coefficient (Y). Practical applications of the model to derive the performance equation of TBAB for treating different inlet IPA and ACE concentrations were also demonstrated. 相似文献
6.
Toluene and acetone mixtures are commonly encountered from the manufacture of semi-conductor or opto-electronic apparatus. This study attempts to employ a trickle-bed air biofilter (TBAB) for treating toluene and acetone mixtures under different gas flow rates and influent concentrations. In the pseudo-steady-states, the elimination capacities of toluene and acetone increased but the removal efficiencies decreased with the increase of influent carbon loading. The removal efficiencies of toluene were higher than those of acetone, indicating that toluene is a preferred substrate in the mixtures. Greater than 90% removal efficiencies were achieved with influent carbon loadings of toluene and acetone below 125 and 15 g/m3 h, respectively. The TBAB appears efficient for controlling toluene and acetone mixture with medium toluene and low acetone loadings. Applicable operating conditions of TBAB for treating mixed toluene and acetone emission are suggested. 相似文献
1