首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Accurate and rapid protein quantitation is essential for screening biomarkers for disease stratification and monitoring, and to validate the hundreds of putative markers in human biofluids, including blood plasma. An analytical method that utilizes stable isotope-labeled standard (SIS) peptides and selected/multiple reaction monitoring-mass spectrometry (SRM/MRM-MS) has emerged as a promising technique for determining protein concentrations. This targeted approach has analytical merit, but its true potential (in terms of sensitivity and multiplexing) has yet to be realized. Described herein is a method that extends the multiplexing ability of the MRM method to enable the quantitation 142 high-to-moderate abundance proteins (from 31 mg/mL to 44 ng/mL) in undepleted and non-enriched human plasma in a single run. The proteins have been reported to be associated to a wide variety of non-communicable diseases (NCDs), from cardiovascular disease (CVD) to diabetes. The concentrations of these proteins in human plasma are inferred from interference-free peptides functioning as molecular surrogates (2 peptides per protein, on average). A revised data analysis strategy, involving the linear regression equation of normal control plasma, has been instituted to enable the facile application to patient samples, as demonstrated in separate nutrigenomics and CVD studies. The exceptional robustness of the LC/MS platform and the quantitative method, as well as its high throughput, makes the assay suitable for application to patient samples for the verification of a condensed or complete protein panel. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge.  相似文献   

2.
We have developed several new methods for blood-based cancer detection by diagnostic proteomics. Ultrasensitive methods of immunoassay using multiphoton-detection (IA/MPD) increase sensitivity by 200- to 1,000-fold (1 femtogram/mL). This has allowed the measurement of cancer biomarkers with very low concentrations in blood that could not be measured for full patient cohorts with conventional immunoassays. Sensitivity and specificity in cancer detection have been found to be potentiated by use of immunoassay panels which include tissue-specific cancer biomarkers as well as cytokines and angiogenic factors. The ultrasensitive immunoassays revealed that patient to patient variations in the concentrations of individual biomarkers in blood can extend over many orders of magnitude (up to six) and that the distributions of biomarker concentrations over patient cohorts are non-Gaussian. New methods of data analysis which correlate abundances of multiple, different biomarkers have been developed to deal with such data sets. Sensitivity and specificity of about 95% have been achieved for blood-based detection of breast cancer in pilot studies on 250 patients and 95 controls. Pilot studies indicate that this methodology may also allow differentiation of malignant breast cancer from benign lesions and can provide similar sensitivity and specificity for other epithelial cancers such as prostate cancer, ovarian cancer and melanoma. The methods developed for selection, application, and evaluation of very high sensitivity biomarker panels are expected to have general relevance for diagnostic proteomics.  相似文献   

3.
Inflammatory bowel disease (IBD) is an immune-mediated chronic inflammation of the intestine, which can present in the form of ulcerative colitis (UC) or as Crohn’s disease (CD). Biomarkers are needed for reliable diagnosis and disease monitoring in IBD, especially in pediatric patients. Plasma samples from a pediatric IBD cohort were interrogated using an aptamer-based screen of 1322 proteins. The elevated biomarkers identified using the aptamer screen were further validated by ELISA using an independent cohort of 76 pediatric plasma samples, drawn from 30 CD, 30 UC, and 16 healthy controls. Of the 1322 proteins screened in plasma from IBD patients, 129 proteins were significantly elevated when compared with healthy controls. Of these 15 proteins had a fold change greater than 2 and 28 proteins had a fold change >1.5. Neutrophil and extracellular vesicle signatures were detected among the elevated plasma biomarkers. When seven of these proteins were validated by ELISA, resistin was the only protein that was significantly higher in both UC and CD (p < 0.01), with receiver operating characteristic area under the curve value of 0.82 and 0.77, respectively, and the only protein that exhibited high sensitivity and specificity for both CD and UC. The next most discriminatory plasma proteins were elastase and lactoferrin, particularly for UC, with receiver operating characteristic area under the curve values of 0.74 and 0.69, respectively. We have identified circulating resistin, elastase, and lactoferrin as potential plasma biomarkers of IBD in pediatric patients using two independent diagnostic platforms and two independent patient cohorts.  相似文献   

4.
A challenge in the treatment of lung cancer is the lack of early diagnostics. Here, we describe the application of monoclonal antibody proteomics for discovery of a panel of biomarkers for early detection (stage I) of non-small cell lung cancer (NSCLC). We produced large monoclonal antibody libraries directed against the natural form of protein antigens present in the plasma of NSCLC patients. Plasma biomarkers associated with the presence of lung cancer were detected via high throughput ELISA. Differential profiling of plasma proteomes of four clinical cohorts, totaling 301 patients with lung cancer and 235 healthy controls, identified 13 lung cancer-associated (p < 0.05) monoclonal antibodies. The monoclonal antibodies recognize five different cognate proteins identified using immunoprecipitation followed by mass spectrometry. Four of the five antigens were present in non-small cell lung cancer cells in situ. The approach is capable of generating independent antibodies against different epitopes of the same proteins, allowing fast translation to multiplexed sandwich assays. Based on these results, we have verified in two independent clinical collections a panel of five biomarkers for classifying patient disease status with a diagnostics performance of 77% sensitivity and 87% specificity. Combining CYFRA, an established cancer marker, with the panel resulted in a performance of 83% sensitivity at 95% specificity for stage I NSCLC.  相似文献   

5.
Biomarkers are becoming increasingly more important in clinical decision-making, as well as basic science. Diagnosing myocardial infarction (MI) is largely driven by detecting cardiac-specific proteins in patients'' serum or plasma as an indicator of myocardial injury. Having recently shown that cardiac myosin binding protein-C (cMyBP-C) is detectable in the serum after MI, we have proposed it as a potential biomarker for MI. Biomarkers are typically detected by traditional sandwich enzyme-linked immunosorbent assays. However, this technique requires a large sample volume, has a small dynamic range, and can measure only one protein at a time.Here we show a multiplex immunoassay in which three cardiac proteins can be measured simultaneously with high sensitivity. Measuring cMyBP-C in uniplex or together with creatine kinase MB and cardiac troponin I showed comparable sensitivity. This technique uses the Meso Scale Discovery (MSD) method of multiplexing in a 96-well plate combined with electrochemiluminescence for detection. While only small sample volumes are required, high sensitivity and a large dynamic range are achieved. Using this technique, we measured cMyBP-C, creatine kinase MB, and cardiac troponin I levels in serum samples from 16 subjects with MI and compared the results with 16 control subjects. We were able to detect all three markers in these samples and found all three biomarkers to be increased after MI. This technique is, therefore, suitable for the sensitive detection of cardiac biomarkers in serum samples.  相似文献   

6.
Verification of candidate biomarkers requires specific assays to selectively detect and quantify target proteins in accessible biofluids. The primary objective of verification is to screen potential biomarkers to ensure that only the highest quality candidates from the discovery phase are taken forward into preclinical validation. Because antibody reagents for a clinical grade immunoassay often exist for a small number of candidates, alternative methodologies are required to credential new and unproven candidates in a statistically viable number of serum or plasma samples. Using multiple reaction monitoring coupled with stable isotope dilution MS, we developed quantitative, multiplexed assays in plasma for six proteins of clinical relevance to cardiac injury. The process described does not require antibodies for immunoaffinity enrichment of either proteins or peptides. Limits of detection and quantitation for each signature peptide used as surrogates for the target proteins were determined by the method of standard addition using synthetic peptides and plasma from a healthy donor. Limits of quantitation ranged from 2 to 15 ng/ml for most of the target proteins. Quantitative measurements were obtained for one to two signature peptides derived from each target protein, including low abundance protein markers of cardiac injury in the nanogram/milliliter range such as the cardiac troponins. Intra- and interassay coefficients of variation were predominantly <10 and 25%, respectively. The configured multiplex assay was then used to measure levels of these proteins across three time points in six patients undergoing alcohol septal ablation for hypertrophic obstructive cardiomyopathy. These results are the first demonstration of a multiplexed, MS-based assay for detection and quantification of changes in concentration of proteins associated with cardiac injury in the low nanogram/milliliter range. Our results also demonstrate that these assays retain the necessary precision, reproducibility, and sensitivity to be applied to novel and uncharacterized candidate biomarkers for verification of proteins in blood.Discovery of disease-specific biomarkers with diagnostic and prognostic utility has become an important challenge in clinical proteomics. In general, unbiased discovery experiments often result in the confident identification of thousands of proteins, hundreds of which may vary significantly between case and control samples in small discovery studies. However, because of the stochastic sampling of proteomes in discovery “omics” experiments, a large fraction of the protein biomarkers “discovered” in these experiments are false positives arising from biological or technical variability. Clearly discovery omics experiments do not lead to biomarkers of immediate clinical utility but rather produce candidates that must be qualified and verified in larger sample sets than were used for discovery (1).Traditional, clinical validation of biomarkers has relied primarily on immunoassays because of their specificity and sensitivity for the target analyte and high throughput capability. However, antibody reagents for a clinical grade immunoassay often only exist for a short list of candidates. The development of a reliable sandwich immunoassay for one target protein is expensive, has a long development time, and is dependent upon the generation of high quality protein antibodies. For the large majority of new, unproven candidate biomarkers, an intermediate verification technology is required that has shorter assay development time lines, lower assay cost, and effective multiplexing of dozens of candidates in low sample volumes. Ideally the approach should be capable of analyzing hundreds of samples of serum or plasma with good precision. The desired outcome of verification is a small number of highly credentialed candidates suitable for traditional preclinical and clinical validation studies.Multiple reaction monitoring (MRM)1 coupled with stable isotope dilution (SID) MS has recently been shown to be well suited for direct quantification of proteins in plasma (24) and has emerged as the core technology for candidate biomarker verification. MRM assays can be highly multiplexed such that a moderate number of candidate proteins (in the range of 10–50) can be simultaneously targeted and measured in the statistically viable number of patient samples required for verification (hundreds of serum samples). However, sensitivity for unambiguous detection and quantification of proteins by MS-based assays is often constrained by sample complexity, particularly when the measurements are being made in complex fluids such as plasma.Many biomarkers of current clinical importance, such as prostate-specific antigen and the cardiac troponins, reside in the low nanogram/milliliter range in plasma and, until recently, have been inaccessible by non-antibody approaches. Our laboratory has recently shown for the first time that a combination of abundant protein depletion with limited fractionation at the peptide level prior to SID-MRM-MS provides robust limits of quantitation (LOQs) in the 1–20 ng/ml range with coefficient of variation (CV) of 10–20% at the LOQ for proteins in plasma (3).Here we demonstrate that this work flow can be extended to configure assays for a number of known markers of cardiovascular disease and, more importantly, can be deployed to measure their concentrations in clinical samples. We modeled a verification study comprising six patients undergoing alcohol septal ablation treatment for hypertrophic obstructive cardiomyopathy, a human model of “planned” myocardial infarction (PMI), and obtained targeted, quantitative measurements for moderate to low concentrations of cardiac biomarkers in plasma. This work provides additional evidence that MS-based assays can be configured and applied to verification of new protein targets for which high quality antibody reagents are not available.  相似文献   

7.
Molecular biomarkers of early stage breast cancer may improve the sensitivity and specificity of diagnosis. Plasma biomarkers have additional value in that they can be monitored with minimal invasiveness. Plasma biomarker discovery by genome-wide proteomic methods is impeded by the wide dynamic range of protein abundance and the heterogeneity of protein expression in healthy and disease populations which requires the analysis of a large number of samples. We addressed these issues through the development of a novel protocol that couples a combinatorial peptide ligand library protein enrichment strategy with isobaric label-based 2D LC-MS/MS for the identification of candidate biomarkers in high throughput. Plasma was collected from patients with stage I breast cancer or benign breast lesions. Low abundance proteins were enriched using a bead-based combinatorial library of hexapeptides. This resulted in the identification of 397 proteins, 22% of which are novel plasma proteins. Twenty-three differentially expressed plasma proteins were identified, demonstrating the effectiveness of the described protocol and defining a set of candidate biomarkers to be validated in independent samples. This work can be used as the basis for the design of properly powered investigations of plasma protein expression for biomarker discovery in larger cohorts of patients with complex disease.  相似文献   

8.

Background

The majority of colorectal cancer (CRC) cases are preventable by early detection and removal of precancerous polyps. Even though CRC is the second most common internal cancer in Australia, only 30 per cent of the population considered to have risk factors participate in stool-based test screening programs. Evidence indicates a robust, blood-based, diagnostic assay would increase screening compliance. A number of potential diagnostic blood-based protein biomarkers for CRC have been reported, but all lack sensitivity or specificity for use as a stand-alone diagnostic. The aim of this study was to identify and validate a panel of protein-based biomarkers in independent cohorts that could be translated to a reliable, non-invasive blood-based screening test.

Principal Findings

In two independent cohorts (n = 145 and n = 197), we evaluated seven single biomarkers in serum of CRC patients and age/gender matched controls that showed a significant difference between controls and CRC, but individually lack the sensitivity for diagnostic application. Using logistic regression strategies, we identified a panel of three biomarkers that discriminated between controls and CRC with 73% sensitivity at 95% specificity, when applied to either of the two cohorts. This panel comprised of Insulin like growth factor binding protein 2 (IGFBP2), Dickkopf-3 (DKK3), and Pyruvate kinase M2(PKM2).

Conclusions

Due to the heterogeneous nature of CRC, a single biomarker is unlikely to have sufficient sensitivity or specificity for use as a stand-alone diagnostic screening test and a panel of markers may be more effective. We have identified a 3 biomarker panel that has higher sensitivity and specificity for early stage (Stage I and -II) disease than the faecal occult blood test, raising the possibility for its use as a non-invasive blood diagnostic or screening test.  相似文献   

9.

Background

Prenatal screening for Down Syndrome (DS) would benefit from an increased number of biomarkers to improve sensitivity and specificity. Improving sensitivity and specificity would decrease the need for potentially risky invasive diagnostic procedures.

Results

We have performed an in depth two-dimensional difference gel electrophoresis (2D DIGE) study to identify potential biomarkers. We have used maternal plasma samples obtained from first and second trimesters from mothers carrying DS affected fetuses compared with mothers carrying normal fetuses. Plasma samples were albumin/IgG depleted and expanded pH ranges of pH 4.5 - 5.5, pH 5.3 - 6.5 and pH 6 - 9 were used for two-dimensional gel electrophoresis (2DE). We found no differentially expressed proteins in the first trimester between the two groups. Significant up-regulation of ceruloplasmin, inter-alpha-trypsin inhibitor heavy chain H4, complement proteins C1s subcomponent, C4-A, C5, and C9 and kininogen 1 were detected in the second trimester in maternal plasma samples where a DS affected fetus was being carried. However, ceruloplasmin could not be confirmed as being consistently up-regulated in DS affected pregnancies by Western blotting.

Conclusions

Despite the in depth 2DE approach used in this study the results underline the deficiencies of gel-based proteomics for detection of plasma biomarkers. Gel-free approaches may be more productive to increase the number of plasma biomarkers for DS for non-invasive prenatal screening and diagnosis.  相似文献   

10.
An emerging approach for multiplexed targeted proteomics involves bottom‐up LC‐MRM‐MS, with stable isotope‐labeled internal standard peptides, to accurately quantitate panels of putative disease biomarkers in biofluids. In this paper, we used this approach to quantitate 27 candidate cancer‐biomarker proteins in human plasma that had not been treated by immunoaffinity depletion or enrichment techniques. These proteins have been reported as biomarkers for a variety of human cancers, from laryngeal to ovarian, with breast cancer having the highest correlation. We implemented measures to minimize the analytical variability, improve the quantitative accuracy, and increase the feasibility and applicability of this MRM‐based method. We have demonstrated excellent retention time reproducibility (median interday CV: 0.08%) and signal stability (median interday CV: 4.5% for the analytical platform and 6.1% for the bottom‐up workflow) for the 27 biomarker proteins (represented by 57 interference‐free peptides). The linear dynamic range for the MRM assays spanned four orders‐of‐magnitude, with 25 assays covering a 103–104 range in protein concentration. The lowest abundance quantifiable protein in our biomarker panel was insulin‐like growth factor 1 (calculated concentration: 127 ng/mL). Overall, the analytical performance of this assay demonstrates high robustness and sensitivity, and provides the necessary throughput and multiplexing capabilities required to verify and validate cancer‐associated protein biomarker panels in human plasma, prior to clinical use.  相似文献   

11.
The diagnosis of trypanosomosis in animals with low parasitaemia is hampered by low diagnostic sensitivity of traditional detection methods. An immunodiagnostic method based on a direct sandwich enzyme-linked immunosorbent assay (ELISA), using monoclonal antibodies, has been examined in a number of African laboratories for its suitability for monitoring tsetse control and eradication programmes. Generally, the direct sandwich ELISAs for the detection of trypanosomal antigens in serum samples have proved to be unsatisfactory with respect to diagnostic sensitivity when compared with traditional parasitological methods such as the dark ground/phase contrast buffy-coat technique. Consequently, antigen-detection systems exploiting various other direct, indirect and sandwich ELISA systems and sets of reagents are being developed to improve diagnosis. In addition, an existing indirect ELISA for the detection of antibodies has been improved and is being evaluated in the field in order to detect cattle that are or have been recently infected with trypanosomes. Developments and advantages of other diagnostic techniques, such as dip-stick assay and tests based on the polymerase chain reaction are also considered.  相似文献   

12.
13.
Diabetic nephropathy (DN) is a serious complication of diabetes caused by changes in the structure and function of the kidneys. It is important to detect diagnostic biomarkers of DN at an early stage, in which the drug can slow the loss of kidney function and prevent disease progression. In recent years, a variety of biological markers related to DN have been discovered, which is of great significance for predicting the occurrence and development of diseases. Due to the simplicity of non-invasive collection, urine is an ideal biological sample for the discovery of new biomarkers of kidney disease. We reviewed some new urinary biomarkers related to early DN patients, including urinary proteins, peptides, and exosomes biomarkers. We also highlight the proteins associated with tubular damage, glomerular damage, inflammation and oxidative stress marker. Despite the promise of these new urinary biomarkers, we next proposed a review of the most recent publications reporting on larger cohorts, focusing on those that aim at qualification or validation. This review provides important data to better understand biomarkers related to the pathophysiology of DN, and these markers have been increasingly studied for disease progression to provide effective human treatment.  相似文献   

14.
DNA microarrays were rapidly scaled up from 256 to 6.5 million targets, and although antibody microarrays were proposed earlier, sensitive multiplex sandwich assays have only been scaled up to a few tens of targets. Cross-reactivity, arising because detection antibodies are mixed, is a known weakness of multiplex sandwich assays that is mitigated by lengthy optimization. Here, we introduce (1) vulnerability as a metric for assays. The vulnerability of multiplex sandwich assays to cross-reactivity increases quadratically with the number of targets, and together with experimental results, substantiates that scaling up of multiplex sandwich assays is unfeasible. We propose (2) a novel concept for multiplexing without mixing named antibody colocalization microarray (ACM). In ACMs, both capture and detection antibodies are physically colocalized by spotting to the same two-dimensional coordinate. Following spotting of the capture antibodies, the chip is removed from the arrayer, incubated with the sample, placed back onto the arrayer and then spotted with the detection antibodies. ACMs with up to 50 targets were produced, along with a binding curve for each protein. The ACM was validated by comparing it to ELISA and to a small-scale, conventional multiplex sandwich assay (MSA). Using ACMs, proteins in the serum of breast cancer patients and healthy controls were quantified, and six candidate biomarkers identified. Our results indicate that ACMs are sensitive, robust, and scalable.  相似文献   

15.
There is a need for reliable and sensitive biomarkers for renal impairments to detect early signs of kidney toxicity and to monitor progression of disease. Here, antibody suspension bead arrays were applied to profile plasma samples from patients with four types of kidney disorders: glomerulonephritis, diabetic nephropathy, obstructive uropathy, and analgesic abuse. In total, 200 clinical renal-associated cases and control plasma samples from different cohorts were profiled. Parallel plasma protein profiles were obtained using biotinylated and nonfractionated samples and a selected set of 94 proteins targeted by 129 antigen-purified polyclonal antibodies. Out of the analyzed target proteins, human fibulin-1 was detected at significantly higher levels in the glomerulonephritis patient group compared to the controls and with elevated levels in patient samples for all other renal disorders investigated. Two polyclonal antibodies and one monoclonal antibody directed toward separate, nonoverlapping epitopes showed the same trend in the discovery cohorts. A technical verification using Western blot analysis of selected patient plasma confirmed the trends toward higher abundance of the target protein in disease samples. Furthermore, a verification study was carried out in the context of glomerulonephritis using an independent case and control cohort, and this confirmed the results from the discovery cohort, suggesting that plasma levels of fibulin-1 could serve as a potential indicator to monitor kidney malfunction or kidney damage.  相似文献   

16.
Recently, selected reaction monitoring mass spectrometry (SRM-MS) has been more frequently applied to measure low abundance biomarker candidates in tissues and biofluids, owing to its high sensitivity and specificity, simplicity of assay configuration, and exceptional multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. Low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed good correlation in several independent clinical serum sample sets. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring candidate biomarkers in human blood, without the need to develop affinity reagents. Furthermore, the simultaneous measurement of multiple biomarkers, including the free and bound forms of PSA, can be performed in a single multiplexed analysis using high-resolution liquid chromatographic separation coupled with SRM-MS. This article is part of a Special Issue entitled: Translational Proteomics.  相似文献   

17.
We developed a pipeline to integrate the proteomic technologies used from the discovery to the verification stages of plasma biomarker identification and applied it to identify early biomarkers of cardiac injury from the blood of patients undergoing a therapeutic, planned myocardial infarction (PMI) for treatment of hypertrophic cardiomyopathy. Sampling of blood directly from patient hearts before, during and after controlled myocardial injury ensured enrichment for candidate biomarkers and allowed patients to serve as their own biological controls. LC-MS/MS analyses detected 121 highly differentially expressed proteins, including previously credentialed markers of cardiovascular disease and >100 novel candidate biomarkers for myocardial infarction (MI). Accurate inclusion mass screening (AIMS) qualified a subset of the candidates based on highly specific, targeted detection in peripheral plasma, including some markers unlikely to have been identified without this step. Analyses of peripheral plasma from controls and patients with PMI or spontaneous MI by quantitative multiple reaction monitoring mass spectrometry or immunoassays suggest that the candidate biomarkers may be specific to MI. This study demonstrates that modern proteomic technologies, when coherently integrated, can yield novel cardiovascular biomarkers meriting further evaluation in large, heterogeneous cohorts.  相似文献   

18.
To date, protein and antibody microarrays have been used in reverse-phase and sandwich-based methods in order to detect known proteins such as biomarkers in samples. Our group developed "libraries" of antibodies against unknown proteins, referred to as mKIAA proteins, and we attempted to discover candidate novel biomarkers by protein expression profiling.To profile mKIAA protein expression using these antibodies, we established an antibody microarray system using chemiluminescent detection. A number of techniques for protein-antibody microarrays have been reported; however, no entirely suitable protocol for crude protein samples has been established. To address this issue, we immobilized purified antibodies on hydrophilic surface polymer slides (Maxisorp, Nunc). Although our system is based on the direct labeling of crude protein samples, we achieved sufficient sensitivity (detection limit: 50 pg mL(-1)) and low backgrounds. This sensitivity is on a level with the sandwich immunoassay-based antibody array system. Using our protocol, we developed an antibody microarray spotted with 960 anti-mKIAA antibodies (total: 3888 spots for quadruplicate assessments), and we carried out protein expression profiling of mKIAA proteins. In this study, we generated an expression profile of 960 mKIAA proteins and compared the present results with those obtained via cDNA microarray.  相似文献   

19.
Despite significant advances in treatment, cardiovascular disease (CVD) remains one of the leading causes of morbidity and mortality in developed and developing countries. Judicious monitoring of common risk factors has been unable to control this global epidemic, necessitating novel biomarkers for improved screening and earlier disease detection and management. Although numerous plasma proteins have been associated with CVD, only a few of these potential biomarkers have been validated for clinical use. Here we review the quantitative proteomic methods used to verify and validate new biomarker candidates in human plasma. These methods center on a bottom-up approach involving multiple or selected reaction monitoring, for targeted detection, with stable isotope-labeled standards, for peptide normalization. Also included are a discussion of future strategies for improved CVD protein biomarker verification and validation, recommendations for method translation to the clinic, and future projections for protein biomarker research.  相似文献   

20.
Early diagnosis and immediate therapeutic interventions are crucial factors to reduce the damage extent and the risk of death. Currently, the diagnosis of stroke relies on neurological assessment of the patient and neuro-imaging techniques including computed tomography and/or magnetic resonance imaging scan. An early diagnostic marker of stroke, ideally capable to discriminate ischemic from hemorrhagic stroke would considerably improve patient acute management. Using surface-enhanced laser desorption/ionization (SELDI) technology, we aimed at finding new early diagnostic plasmatic markers of stroke. Strong anionic exchange (SAX) SELDI profiles of plasma samples from 21 stroke patients were compared to 21 samples from healthy controls. Seven peaks appeared to be differentially expressed with significant p values (p < 0.05). Proteins were stripped from the SAX chips, separated on a one-dimensional electrophoresis (1-DE) gel and stained using mass spectrometry (MS)-compatible silver staining. Following in-gel tryptic digestion, the peptides were analyzed by MS. Four candidate proteins were identified as apolipoprotein CI (ApoC-I), apolipoprotein CIII (ApoC-III), serum amyloid A (SAA), and antithrombin-III fragment (AT-III fragment). Assessment of ApoC-I and ApoC-III levels in plasma samples using a sandwich enzyme-linked immunosorbent assay (ELISA) allowed to distinguish between hemorrhagic (n = 15) and ischemic (n = 16) stroke (p < 0.001). To the best of our knowledge, ApoC-I and ApoC-III are the first reported plasmatic biomarkers capable to accurately distinguish between ischemic and hemorrhagic stroke in a small number of patients. It requires further investigation in a large cohort of patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号