首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The quartz crystal microbalance (QCM) was first introduced as a mass sensor in gas phase and in vacuum. Since oscillator circuits capable of exciting shear vibrations of quartz resonators under liquid loading have been developed, the QCM became accepted as a new, powerful technique to follow adsorption processes at solid-liquid interfaces in chemical and biological research. Lately, the QCM technique has attracted considerable interest as a novel means to monitor cell-substrate interactions of mammalian cells in vitro. Because the establishment and modulation of cell-substrate contacts is important for many physiological processes, and potent techniques to measure these interactions noninvasively are rare, the present review highlights applications of the QCM technique in this field. The suitability of the QCM device to monitor attachment and spreading of mammalian cells in real time has been well established. The QCM response is dependent on the individual cell type that is examined. In order to identify the sources for these cell-type-specific results of QCM readings, and to understand the information content of the signal, attempts have been made to decompose the overall QCM response into subcellular contributions. The aforementioned subjects, together with a condensed introduction into the QCM technology, are included in this article.  相似文献   

2.
用石英晶体微天平(quartz crystal microbalance,QCM)和活细胞成像技术实时监测人脐静脉内皮细胞(HUVEC)在ITO石英晶体电极上的动态粘附响应过程。在ITO晶体电极上加入不同浓度的HUVEC,测定细胞在QCM上谐振频率以及耗散的实时变化。通过ITO电极与光学显微镜的联用,监测了HUVEC在药物处理前后的动态变化过程。用细胞粘弹性指数(QCM的动态电阻变化与频移变化之比,CVI=ΔR/Δf)表征细胞的粘弹性变化,同时通过活细胞成像技术的联用,实时监测细胞的形态变化。结果表明:细胞浓度为10万个/m L时,细胞在ITO电极上铺展完全且粘弹性最大。抑制剂y-27632和激动剂凝血酶thrombin药物处理细胞前后,在显微镜的实时监测下细胞形态变化不明显,但CVI粘弹性指数变化较大,说明QCM信号比光学信号更为敏感,且在药物筛选方面有有很大的应用前景。  相似文献   

3.
The processes of adhesion, spreading and proliferation of human mammary cancer cells MCF-7 on two Au electrodes with different surface roughness (R(f) and R(f)=3.2 or 1.1) were monitored and clearly identified with the quartz crystal microbalance (QCM) technique. Analyses of the QCM responses on the resonant frequency shifts (Deltaf(0)) vs. the motional resistance changes (DeltaR(1)) revealed a significant surface-stress effect in the involved courses, in addition to a viscodensity effect and a relatively small mass effect (especially at the smooth electrode). Experiments of fluorescence microscopy, cyclic voltammetry and electrochemical impedance spectroscopy were conducted to investigate the cell population on the electrode vs. the electrode-surface roughness. Simplified equations are deduced to quantitatively evaluate the surface stress, and a novel QCM method for dynamically measuring the surface stress on an electrode in cell-culture course is thus described. It was found that the smoother surface (R(f)=1.1) gave a higher surface stress during cell attachment and less cell population on it than the rougher surface (R(f)=3.2). In addition, real-time QCM monitoring showed on the same electrode the surface stress induced by hepatic normal cells being notably higher than that caused by hepatic cancer cells at cell-attachment stage, suggesting that the surface-stress measurement can exhibit the difference of adhesion-performance between the healthy and ill-behaved cells.  相似文献   

4.
The quartz crystal microbalance (QCM) has been widely accepted as a sensitive technique to follow adsorption processes in gas as well as in liquid environments. However, there are only a few reports about the use of this technique to monitor the attachment and spreading of mammalian cells onto a solid support in culture. Using a QCM-setup we investigated the time course of cell attachment and spreading as a function of seeding density for three widespread and frequently used cell lines (MDCK strains I and II and Swiss 3T3-fibroblasts). Results were found to be in good agreement with the geometrical properties of the individual cell types. The shifts of the resonance frequency associated with confluent cell layers on top of the quartz resonators were found to be dependent on the cell species [MDCK-I: (320±20) Hz; MDCK-II: (530±25) Hz; 3T3: (240±15) Hz] reflecting their individual influence on the shear oscillation of the resonator. These findings are discussed with respect to the basic models of materials in contact with an oscillating quartz resonator. We furthermore showed by inhibition-assays using soluble RGD-related peptides, that only specific, integrin mediated cell adhesion is detected using this QCM approach, whereas the sole presence of the cellular body in close vicinity to the resonator surface is barely detectable.  相似文献   

5.
The quartz crystal microbalance (QCM) was used to create a piezoelectric biosensor utilizing living endothelial cells (ECs) as the biological signal transduction element. ECs adhere to the hydrophilically treated gold QCM surface under growth media containing serum. At 24 h following cell addition, calibration curves were constructed relating the steady state Δf and ΔR shift values observed to the numbers of electronically counted cells requiring trypsinization to be removed from the surface. We then utilized this EC QCM biosensor for the detection of the effect of [nocodazole] on the steady state Δf and ΔR shift values. Nocodazole, a known microtubule binding drug, alters the cytoskeletal properties of living cells. At the doses used in these studies (0.11–15 μM), nocodazole, in a dose dependent fashion, causes the depolymerization of microtubules in living cells. This leads a monolayer of well spread ECs to gradually occupy a smaller area, lose cell to cell contact, exhibit actin stress fibers at the cell periphery and acquire a rounded cell shape. We observed the negative Δf shift values and the positive ΔR shift values to increase significantly in magnitude over a 4-h incubation period following nocodazole addition, in a dose dependent fashion, with a transition midpoint of 900 nM. Fluorescence microscopy of the ECs, fixed on the gold QCM surface and stained for actin, demonstrated that the shape and cytoskeleton of ECs were affected by as little as 330 nM nocodazole. These results indicate that the EC QCM biosensor can be used for the study of EC attachment and to detect EC cytoskeletal alterations. We suggest the potential of this cellular biosensor for the real time identification or screening of all classes of biologically active drugs or biological macromolecules that affect cellular attachment, regardless of their molecular mechanism of action.  相似文献   

6.
Biocompatibility of polymers is an important parameter for the successful application of polymers in tissue engineering. In this work, quartz crystal microbalance (QCM) devices were used to follow the adhesion of NIH 3T3 fibroblasts to QCM surfaces modified with fibronectin (FN) and poly-D -lysine (PDL). The variations in sensor resonant frequency (Δf) and motional resistance (ΔR), monitored as the sensor signal, revealed that cell adhesion was favored in the PDL-coated QCMs. Fluorescence microscopy images of seeded cells showed more highly spread cells on the PDL substrate, which is consistent with the results of the QCM signals. The sensor signal was shown to be sensitive to extracellular matrix (ECM)-binding motifs. Ethylenediaminetetraacetic acid (EDTA) and soluble Gly-Arg-Gly-Asp-Ser (GRGDS) peptides were used to interfere with cell-ECM binding motifs onto FN-coated QCMs. The acquired acoustic signals successfully showed that in the presence of 30 mM EDTA or 1 mM GRGDS, cell adhesion is almost completely abolished due to the inhibition/blocking of integrin function by these compounds. The results presented here demonstrate the potential of the QCM sensor to study cell adhesion, to monitor the biocompatibility of polymers and materials, and to assess the effect of adhesion modulators. QCM sensors have great potential in tissue engineering applications, as QCM sensors are able to analyze the biocompatibility of surfaces and it has the added advantage of being able to evaluate, in situ and in real time, the effect of specific drugs/treatments on cells.  相似文献   

7.
During transformation of a normal cell to a cell capable of forming a cancerous growth, cellular morphology, the cytoskeleton, and focal contacts undergo significant changes. These changes should be capable of being characterized via real-time monitoring of the dynamic cell adhesion process and viscoelastic properties of cells. Here, we describe use of the quartz crystal microbalance (QCM) to distinguish the dynamic cell adhesion signatures of human normal (HMEC) versus malignant (MCF-7) mammary epithelial cells. The significantly reduced QCM responses (changes in frequency [Δf] and motional resistance ΔR) of MCF-7 cells compared with those of HMECs mirror the cancer cells' morphological features as observed via optical microscope. We analyzed the initial 2-h cell adhesion kinetics, suggesting cell-cell cooperativity for HMECs and no or weak cell-cell interactions for MCF-7 cells. We propose that changes of the ΔR/Δf ratio, which we term the cell viscoelastic index (CVI), reflect the establishment of cytoskeleton structure and dynamic viscoelastic properties of living cells. The CVI decreases significantly on initiation of cell to surface interactions as cells establish their cytoskeletal structures. During the cell adhesion process, MCF-7 cells were consistently softer, exhibiting up to a 2.5-fold smaller CVI when compared with HMECs.  相似文献   

8.
The quartz crystal microbalance (QCM) was used to create piezoelectric whole-cell biosensors utilizing either living endothelial cells (ECs) or the metastatic human mammary cancer cell line MDA-MB-231 adhering to the gold QCM surface under in vitro growth conditions. We utilized the whole-cell QCM biosensors for the detection of the effects of varying concentrations of the microtubule binding drugs taxol and nocodazole by measuring changes in the QCM steady state frequency (Deltaf) and motional resistance (DeltaR), shift values. Using 0.11-50 microM nocodazole, we observed the Deltaf shift values of the biosensors, consisting of 20,000 ECs, to decrease significantly in magnitude (nearly 100%) to a limiting value, in a dose-dependent fashion, over a 5- to 6-h incubation period following drug addition. This effect is consistent with nocodazole's known disruption of intracellular microtubules. On the other hand, 10 microM taxol caused little alteration in Deltaf over the same time period, consistent with its microtubule hyperstabilization effect. When the EC QCM biosensor Deltaf shift values were normalized by the number of ECs found firmly attached to the QCM surface via trypsin removal and electronic counting, the dose curve was shifted to lower nocodazole concentrations, resulting in a more sensitive drug biosensor. The kinetics of the Deltaf decrease with increasing nocodazole concentrations measured by the EC QCM biosensor was found to be similar at all drug concentrations and was well fit by a single first-order exponential decay equation. For all nocodazole doses, t(0.5) was invariant, averaging t(0.5)=0.83+/-0.14 h. These data demonstrate that a single dynamic sensing system within the cell, the microtubules, is disrupted by the addition of nocodazole and this process is sensed by the cell QCM biosensor. This interpretation of the data was confirmed by a fluorescence light microscopy investigation of ECs undergoing treatment with increasing nocodazole doses using a fluorescent antibody to alpha-tubulin. These studies revealed a corresponding loss of the spread morphology of the cells, concomitant with a rearrangement of the extended native microtubules into increasingly large aggregates with the cells eventually lifting from the surface in significant numbers at 50 microM. At 6 microM nocodazole, partial reversibility of the EC QCM biosensor was demonstrated. These results indicate that the EC QCM biosensor can be used to detect and study EC cytoskeleton alterations and dynamics. We suggest the potential of this cellular biosensor for the real-time identification or screening of all classes of biologically active drugs or biological macromolecules that affect cellular attachment and cellular spreading, regardless of their molecular mechanism of action.  相似文献   

9.
A polymer film of porphyrin was formed through electropolymerization of p-amino-substituted tetraphenylporphyrin on indium tin oxide (ITO) surfaces. The adhesion and proliferation of MCF-7 cells (human breast cancer cell line) on the film were investigated. It was found that cells cultured on this film could attach and spread more rapidly than on glass, ITO and tissue culture polystyrene (TCPS), and thus the film was demonstrated to be a good adhering substrate. MTT experimental results show that the viability of cells cultured on this film is higher than on TCPS, and fluorescence microscopic observation indicates that cells cultured on the film are not under apoptosis. Based on its excellent cytocompatibility, the polyporphyrin film was used to modify the gold electrode surface of a piezoelectric quartz crystal, and quartz crystal microbalance (QCM) technique was applied for real-time monitoring of MCF-7 cell growth and assessment of chemical cytotoxicity. The proliferation and condition of cells on the surface of the film-modified quartz crystal gold electrode were investigated through fluorescence microscopic observation. The results obtained from QCM experiments are consistent with that from microscopic observation. Additionally, the polymerized film on gold surface can be removed completely and easily, which greatly improves the reproducibility of the quartz crystal gold electrode.  相似文献   

10.
The suitability of the quartz crystal microbalance (QCM) technique for monitoring the attachment and spreading of mammalian cells has recently been established. Different cell species were shown to generate an individual response of the QCM when they make contact with the resonator surface. Little is known, however, about the underlying mechanisms that determine the QCM signal for a particular cell type. Here we describe our results for different experimental approaches designed to probe the particular contributions of various subcellular compartments to the overall QCM signal. Using AC impedance analysis in a frequency range that closely embraces the resonators' fundamental frequency, we have explored the signal contribution of the extracellular matrix, the actin cytoskeleton, the medium that overlays the cell layer, as well as the liquid compartment that is known to exist between the basal plasma membrane and the culture substrate. Results indicate that the QCM technique is only sensitive to those parts of the cellular body that are involved in cell substrate adhesion and are therefore close to the resonator surface. Because of its noninvasive nature, sensitivity, and time resolution, the QCM is a powerful means of quantitatively studying various aspects of cell-substrate interactions.  相似文献   

11.
Quartz crystal microbalance (QCM) sensors are widely used for determining liquid properties or probing interfacial processes. For some applications the sensitivity of the QCM sensors typically used (5–20 MHz) is limited compared with other biosensor methods. In this study ultrasensitive QCM sensors with resonant frequencies from 39 to 110 MHz for measurements in the liquid phase are presented. The fundamental sensor effect of a QCM is the decrease of the resonant frequency of an oscillating quartz crystal due to the binding of mass on a coated surface during the measurement. The sensitivity of QCM sensors increases strongly with an increasing resonant frequency and, therefore, with a decreasing thickness of the sensitive area. The new kind of ultrasensitive QCM sensors used in this study is based on chemically milled shear mode quartz crystals which are etched only in the center of the blank, forming a thin quartz membrane with a thick, mechanically stable outer ring. An immunoassay using a virus specific monoclonal antibody and a M13-Phage showed an increase in the signal to noise ratio by a factor of more than 6 for 56 MHz quartz crystals compared with standard 19 MHz quartz crystals, the detection limit was improved by a factor of 200. Probing of acoustic properties of glycerol/water mixtures resulted in an increase in sensitivity, which is in very good agreement with theory. Chemically milled QCM sensors strongly improve the sensitivity in biosensing and probing of acoustic properties and, therefore, offer interesting new application fields for QCM sensors.  相似文献   

12.
Recent applications of quartz crystal resonant sensor technology to monitor cell adhesion and specific ligand interaction processes has triggered the development of a new category of quartz crystal microbalance (QCM) based biosensors. In this study human oral epithelial cells (H376) were cultured on quartz sensors and their response to microspheres investigated in situ using the QCM technique. The results demonstrated that this novel biosensor was able to follow cell-microsphere interactions in real-time and under conditions of flow as would occur in the oral cavity. Unique frequency profiles generated in response to the microspheres were postulated to be due to phases of mass addition and altered cellular rigidity. Supporting microscopic evidence demonstrated that the unique frequency responses obtained to these interactions were in part due to binding between the cell surface and the microspheres. Furthermore, a cellular uptake process, in response to microsphere loading was identified and this, by influencing the rigidity of the cellular cytoskeleton, was also detectable through the frequency responses obtained.  相似文献   

13.
The quartz crystal microbalance (QCM) was used to monitor specific, integrin-mediated adhesion of human ovarian cancer cells to distinct extracellular matrix (ECM) proteins immobilized on gold-coated quartz crystal resonators. The QCM was operated in the impedance analysis mode, where frequency shift as well as bandwidth are accessible on a broad range of overtones. The increase in bandwidth caused by covering the quartz resonator with cells was reproducible and largely independent of overtone order, whereas the frequency shift displayed some variability. Thus the bandwidth proved to be the more robust parameter for sensing cell adhesive events. The bandwidth increased in proportion to the number of seeded cells to the quartz crystal as long as the number was below 150,000 cells/ml. Comparing the resonance parameters on different harmonics, one finds that viscoelastic modeling with homogeneous layer systems cannot reproduce the results: lateral heterogeneity has to be taken into account. The differences in adhesive strength of human ovarian cancer cells towards selected ECM proteins monitored by QCM was in good agreement with data obtained by conventional cell adhesion assays. Strong cell adhesion was observed to the ECM proteins vitronectin (VN) and fibronectin (FN), while only weak attachment occurred on laminin. In order to prove specific, integrin alphavbeta3-mediated cell adhesion to its ligands FN and VN, the cyclic integrin alphavbeta3-directed peptide c(RGDfV) was used as competitor and significantly reversed cell adhesion. Since integrin interaction with ECM proteins is dependent on the presence of bivalent cations, cell detachment was also seen after treatment of cell monolayers with the chelator ethylene-dinitro-tetra-acetic acid (EDTA). The QCM technique is a reliable method to monitor cell adsorption to ECM-pretreated surfaces in real time. It may be an alternative tool for screening specific and selective antagonists of integrin/ECM interaction.  相似文献   

14.
For investigating effects of chemical stressors to cultured cells, we have developed a quartz crystal microbalance (QCM) system with a micro CCD camera that enables microscopic observations simultaneously with the QCM measurements. Human hepatoma cell line (HepG2) cells were cultured on the collagen coated quartz crystal which has indium tin oxide (ITO) electrodes that enable transmission imaging of the cultured cells by the micro CCD camera during the QCM measurements. Glutaraldehyde (GA) and t-butylhydroperoxide (t-BHP) were used for the chemical stressors. The response of the QCM was monitored and analyzed with the resonance frequency and the resonance resistance (F-R) diagram. At the same time, the photographs of the cells were recorded to observe the morphological change. In the case of GA, the QCM responded in two steps which consisted of the rapid response of the cross-linking reactions and successive decreasing cytoskeletons in the cells. In the case of t-BHP, the response showed two steps. At first, the cells changed their shapes to round, and then the weakened cells were unsticked from the surface.  相似文献   

15.
The quartz crystal microbalance (QCM) was used to monitor endothelial cell (EC) adhesion on the gold surface of an oscillating quartz crystal contained in a QCM device. A number of parameters were investigated. First, we observed differential QCM O-ring toxicities for ECs. Second, appropriate conditions for cell culture and QCM cell environment were identified that can eliminate large-scale frequency oscillations in the measurements. These artifacts are not due to added cells but originate in the time-dependent evaporation of water. Having eliminated these artifacts, we then demonstrated that the measured steady-state crystal frequency shift, Delta f, and motional resistance shift, DeltaR, were determined by the number of firmly attached ECs requiring trypsinization from the crystal surface. Last, following steady-state attachment of ECs, the EC growth stimulation by fibroblast growth factor was monitored in a continuous fashion by measuring f and R values over a 72 h. period. We observed the Delta f values to increase in a way that reflected the increase in EC number bound to the QCM surface. Following addition of ECs to the QCM, the time-dependent increase in DeltaR can be interpreted in terms of increase by the ECs of the energy dissipation properties of the solution at the solution-gold surface interface. This effect is due to their rapid surface attachment and the elaboration of their cytoskeletal properties. These results indicate that the QCM technique can be used for the study of EC attachment and growth and suggest its potential for the real time study of per unit surface area cell mass distribution dynamics and viscoelastic properties and the cells' responses to stresses or perturbations brought about using biologically active molecules.  相似文献   

16.
L.ymphocyte interactions with endothelial cells in microcirculation are an important regulatory step in the delivery of lymphocytes to peripheral sites of inflammation. In normal circumstances, the predicted wall shear stress in small venules range from 10 to 100 dyn/cm2. Attempts to measure the adhesion of lymphocytes under physiologic conditions have produced variable results, suggesting the importance of studying biologically relevant migratory lymphocytes. To quantify the effect of shear stress on these migratory lymphocytes, we used lymphocytes obtained from sheep efferent lymph ducts, defined as migratory cells, to perfuse sheep endothelial monolayers under conditions of flow. Quantitative cytomorphometry was used to distinguish cells in contact with the endothelial monolayers from cells in the flow stream. As expected, migratory cells in contact with the normal endothelial monolayer demonstrated flow velocities less than the velocity of cells in the adjacent flow stream. The flow velocities of these efferent lymphocytes were independent of cell size. To model the inflammatory microcirculation, lymphocytes were perfused over sequential endothelial monolayers to directly compare the velocity of cells in contact with cytokine-activated and unactivated control monolayers. The tumor necrosis factor and interleukin-1-activated endothelial monolayers marginally decreased cell velocities at 1.2 dyn/cm2 (3.6%), but significantly reduced cell velocities 0.3 dyn/cm2 (27.4%; P < 0.05). Similarly, the fraction of statically adherent lymphocytes decreased as shear stress increased to 1.2 dyn/cm2. These results suggest that typical wall shear stress in small venules. of the order of 20 dyn/cm2, are too high to permit adhesion and transmigration of migratory lymphocytes. Additional mechanisnis must be present in vivo to facilitate lymphocyte transmigration in the inflammatory microcircu-  相似文献   

17.
A parallel-plate flow chamber was used to quantify the detachment of normal, transformed, and reverted rat fibroblasts from a confluent monolayer of normal fibroblasts. In this method, known shear stresses were applied to the adherent cells and the percent of cells detached from the monolayer was determined. Results indicate that the detachment of all cell types increased with increasing shear stress and detachment of highly metastatic ras-transformed cells was significantly higher than that of either nonmetastatic normal cells or transformed cells reverted with the Kirsten ras revertant (K-rev 1a) gene, which are lowly metastatic. From these results, it is concluded that a correlation exists between the metastatic phenotype of the cell and its ability to detach from normal cells.  相似文献   

18.
Shear stress is one of mechanical constraints which are exerted by blood flow on endothelial cells (ECs). To adapt to shear stress, ECs align in the direction of flow through adherens junction (AJ) remodeling. However, mechanisms regulating ECs alignment under shear stress are poorly understood. The scaffold protein IQ domain GTPase activating protein 1 (IQGAP1) is a scaffold protein which couples cell signaling to the actin and microtubule cytoskeletons and is involved in cell migration and adhesion. IQGAP1 also plays a role in AJ organization in epithelial cells. In this study, we investigated the potential IQGAP1 involvement in the endothelial cells alignment under shear stress. Progenitor-derived endothelial cells (PDECs), transfected (or not) with IQGAP1 small interfering RNA, were exposed to a laminar shear stress (1.2 N/m2) and AJ proteins (VE-cadherin and β-catenin) and IQGAP1 were labeled by immunofluorescence. We show that IQGAP1 is essential for ECs alignment under shear stress. We studied the role of IQGAP1 in AJs remodeling of PDECs exposed to shear stress by studying cell localization and IQGAP1 interactions with VE-cadherin and β-catenin by immunofluorescence and Proximity Ligation Assays. In static conditions, IQGAP1 interacts with VE-cadherin but not with β-catenin at the cell membrane. Under shear stress, IQGAP1 lost its interaction from VE-cadherin to β-catenin. This “switch” was concomitant with the loss of β-catenin/VE-cadherin interaction at the cell membrane. This work shows that IQGAP1 is essential to ECs alignment under shear stress and that AJ remodeling represents one of the mechanisms involved. These results provide a new approach to understand ECs alignment under to shear stress.  相似文献   

19.
The quartz crystal microbalance (QCM) technique has been applied to the real time monitoring of endothelial cell (EC) adhesion and spreading on the QCM gold surface. We previously showed that the measured QCM Deltaf and DeltaR shifts were due to cells adhering to the gold crystal surface, requiring proteolytic enzyme treatment to be removed from the surface, in order for the Deltaf and DeltaR shifts to return to zero. In the present report, we demonstrate the quantitative dependence and saturation of the measured Deltaf and DeltaR shifts on the number of firmly attached ECs as measured by electronic counting of the cells. We demonstrate through a light microscope simulation experiment that the different Deltaf and DeltaR regions of the QCM temporal response curve correspond to the incident ECs contacting the surface, followed by their adhesion and spreading, which reflect cellular mass distribution and cytoskeletal viscoelasticity changes. Also, we demonstrate that the dose response curve of Deltaf and DeltaR values versus attached EC number is more sensitive and possesses less scatter for the hydrophilically treated surface compared to the native gold surface of the QCM. For both surfaces, a Deltaf and DeltaR versus trypsinized, attached EC number plot 1 h post-seeding exhibits a sigmoid curve shape whereas a similar plot 24 h post-seeding exhibits a hyperbolic curve shape. This number dependence suggests cell-cell cooperativity in the initial cell adhesion and spreading processes. These QCM data and our interpretation are corroborated by differences in cell appearance and spreading behavior we observed for ECs in a light microscope fluorescence simulation experiment of the cell density effect. For a stably attached EC monolayer at 24 h post-addition, steady-state Deltaf and DeltaR values are higher and exhibit saturation behavior for both the hydrophilically treated gold surface as compared to the untreated surface. The steady-state 24 h Deltaf and DeltaR values of stably attached ECs are shifted from the 1 h attached ECs. The 24 h values are characteristic of a more energy-dissipative structure. This is consistent with the time-dependent elaboration of surface contacts in anchorage-dependent ECs via the attachment of intregrins to underlying extracellular matrix. It is also in agreement with the known energy dissipation function of the ECs that cover the interior of blood vessels and are exposed to continuous pulsatile blood flow.  相似文献   

20.
We have developed a technique to manipulate human red blood cells (RBCs) in hydrodynamic flows. This method applies optical tweezers to trap and move microbead-attached RBCs in a liquid medium at various speeds, while it significantly minimizes laser heating and photon-induced stress for normal operation with laser-trapped cells. Computational fluid dynamics is applied to simulate flow-induced shear stress over the cell membrane and to correlate quantitatively the forces with the cell deformations. RBCs can be manipulated under physiological conditions by this approach, which may open an avenue to design principles for the next generation of cell sorting and delivery.  相似文献   