1.
Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances the effectiveness of continuous chlorination in biofouling control. This information suggests that control of Legionella species in cooling towers can be accomplished by operating the towers under alkaline conditions. To test this possibility, we collected water samples over a period of months from a hospital cooling tower. The samples were analyzed for a variety of chemical parameters. Subsamples were pasteurized and inoculated with non-agar-passaged Legionella pneumophila which had been maintained in tap water. Correlation of subsequent Legionella growth with corresponding pH and alkalinity values revealed statistically significant inverse associations. These data support the hypothesis that operating cooling towers outside of the optimal conditions for Legionella growth (e.g., at elevated alkalinities and a pH greater than 9) may be a useful approach to controlling growth in this habitat.  相似文献   

2.
Legionella spp. in Puerto Rico cooling towers.   总被引:1,自引:1,他引:0       下载免费PDF全文
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10(5) cells per ml, which is within the range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.  相似文献   

3.
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10(5) cells per ml, which is within the range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.  相似文献   

4.
We describe a new species of Legionella represented by 10 strains isolated from industrial cooling towers. Legionella oakridgensis differed genetically from the other seven species of Legionella in DNA hybridization studies and differed serologically in direct fluorescent-antibody tests. The new species, unlike all other species except L. jordanis, did not require added L-cysteine for growth in serial transfer on charcoal-yeast extract agar. L. oakridgensis, as well as three other species tested, required L-cysteine for primary isolation from animal tissues. L. oakridgensis was the only species of Legionella that failed to produce alkaline phosphatase at pH 8.5. In all other respects, it resembled other species of Legionella, including having a high content of branched-chain cellular fatty acids and being pathogenic for guinea pigs. These bacteria have not yet been associated with human disease, but they are potential causes of legionellosis.  相似文献   

5.
The effect of Aeromonas strains on the growth of Legionella   总被引:1,自引:0,他引:1  
Thirty-one environmental and two type strains of Aeromonas were tested for their ability to inhibit the growth of strains of several Legionella species. Of 10 Legionella spp. tested, only Legionella pneumophila and Leg. longbeachae were able to resist the inhibitory effects of some of the Aeromonas strains. Selected Aeromonas strains were also tested for their ability to inhibit the growth of several non-legionella strains. None of the non-legionella strains were inhibited by any of the selected Aeromonas strains. Attempts were made to isolate Aeromonas strains from cooling towers and Aeromonas hydrophila was isolated from one of the cooling towers tested. The results suggest that many strains of Aeromonas can inhibit the growth of Legionella strains on solid media and could affect the isolation of legionellas from water sources.  相似文献   

6.
A protocol for sampling environmental sites was developed and used to identify possible sources of Legionella species in support of epidemiologic investigations at two hospitals. In hospital A, legionellae were isolated from 43 of 106 (40%) different sites. Three separate Legionella pneumophila serotypes and a previously unrecognized species were present in different combinations in the positive samples. Two of five cooling towers contained the same L. pneumophila serogroup 1 monoclonal type (1,2,4,5) as was isolated from patients. The same monoclonal type was also isolated from make-up water for the two cooling towers, a hot water tank, water separators in four main air compressor systems for respiratory therapy, and cold and hot water faucets. In hospital B, 13 of 37 (38%) sample sites contained legionellae, all of which were L. pneumophila serogroup 1. The monoclonal type matching isolates from patients (1,2,4,5) was found at the highest concentration in a hot water tank, but it was also present at four other sample sites. Since legionellae not related to disease may be found in many of the sites sampled, an epidemiologic association with the probable source should be established before intervention methods, such as disinfection, are undertaken.  相似文献   

7.
Protocol for sampling environmental sites for legionellae.   总被引:4,自引:2,他引:2       下载免费PDF全文
A protocol for sampling environmental sites was developed and used to identify possible sources of Legionella species in support of epidemiologic investigations at two hospitals. In hospital A, legionellae were isolated from 43 of 106 (40%) different sites. Three separate Legionella pneumophila serotypes and a previously unrecognized species were present in different combinations in the positive samples. Two of five cooling towers contained the same L. pneumophila serogroup 1 monoclonal type (1,2,4,5) as was isolated from patients. The same monoclonal type was also isolated from make-up water for the two cooling towers, a hot water tank, water separators in four main air compressor systems for respiratory therapy, and cold and hot water faucets. In hospital B, 13 of 37 (38%) sample sites contained legionellae, all of which were L. pneumophila serogroup 1. The monoclonal type matching isolates from patients (1,2,4,5) was found at the highest concentration in a hot water tank, but it was also present at four other sample sites. Since legionellae not related to disease may be found in many of the sites sampled, an epidemiologic association with the probable source should be established before intervention methods, such as disinfection, are undertaken.  相似文献   

8.
Studies on Legionella show a continuum from environment to human disease. Legionellosis is caused by Legionella species acquired from environmental sources, principally water sources such as cooling towers, where Legionella grows intracellularly in protozoa within biofilms. Aquatic biofilms, which are widespread not only in nature, but also in medical and dental devices, are ecological niches in which Legionella survives and proliferates and the ultimate sources to which outbreaks of legionellosis can be traced. Invasion and intracellular replication of L. pneumophila within protozoa in the environment play a major role in the transmission of Legionnaires' disease. Protozoa provide the habitats for the environmental survival and reproduction of Legionella species. L. pneumophila proliferates intracellularly in various species of protozoa within vacuoles studded with ribosomes, as it also does within macrophages. Growth within protozoa enhances the environmental survival capability and the pathogenicity (virulence) of Legionella . The growth requirements of Legionella , the ability of Legionella to enter a viable non-culturable state, the association of Legionella with protozoa and the occurrence of Legionella within biofilms complicates the detection of Legionella and epidemiological investigations of legionellosis. Polymerase chain reaction (PCR) methods have been developed for the molecular detection of Legionella and used in environmental and epidemiological studies. Various physical and chemical disinfection methods have been developed to eliminate Legionella from environmental sources, but gaining control of Legionella in environmental waters, where they are protected from disinfection by growing within protozoa and biofilms, remains a challenge, and one that must be overcome in order to eliminate sporadic outbreaks of legionellosis.  相似文献   

9.
Amoeba-resisting bacteria (ARB) such as Legionella spp. are currently regarded as potential human pathogens living in the environment. To detect ARB from both human and environmental samples, co-culture with amoebae has been demonstrated as an efficient tool. However, using this procedure, mostly water from cooling towers and hospital water supplies have been investigated as the possible reservoir of ARB. In the present study, we studied ARB population in 77 environmental water samples including rivers, fountains, lakes and domestic wells in the south of France. As a result, a total of 244 isolates corresponding to 89 different species of ARB, but not Legionella spp., were identified. Ability to grow within and/or to be lytic for amoebae was revealed for the first time for several human pathogens . Six isolates are likely to be the members of a new or uncharacterized genus/species. An anaerobic bacterium, Clostridium frigidicarnis was demonstrated to be lytic for amoebae. This preliminary work demonstrates that the water environment in the vicinity of humans is a reservoir of ARB, including well-known pathogens for which amoebae and/or water was not recognized earlier as a possible reservoir.  相似文献   

10.
An investigation of the chemical environment and growth of Legionella pneumophila in plumbing systems was conducted to gain a better understanding of its ecology in this habitat. Water samples were collected from hospital and institutional hot-water tanks known to have supported L. pneumophila and were analyzed for 23 chemical parameters. The chemical environment of these tanks was found to vary extensively, with the concentrations of certain metals reaching relatively high levels due to corrosion. The effect of various chemical conditions on L. pneumophila growth was then examined by observing its multiplication in the chemically analyzed hot-water tank samples after sterilization and reinoculation with L. pneumophila. L. pneumophila and associated microbiota used in these experiments were obtained from a hot-water tank. These stains were maintained in tap water and had never been passaged on agar. The results of the growth studies indicate that although elevated concentrations of a number of metals are toxic, lower levels of certain metals such as iron, zinc, and potassium enhance growth of naturally occurring L. pneumophila. Parallel observations on accompanying non-Legionellaceae bacteria failed to show the same relationship. These findings suggest that metal plumbing components and associated corrosion products are important factors in the survival and growth of L. pneumophila in plumbing systems and may also be important in related habitats such as cooling towers and air-conditioning systems.  相似文献   

11.
Methods are described for detection of Legionella pneumophila in cooling tower water or other water sources by direct fluorescent-antibody staining. A procedure for isolation of Legionella bacteria from water samples by guinea pig inoculation is described. Two different serogroups of L. pneumophila were isolated repeatedly from one of the cooling towers.  相似文献   

12.
The presence of PCR inhibitors in water samples is well known and contributes to the fact that a practical PCR assay has not been developed for legionella surveillance. In this study, we devised a new seminested PCR assay for detection of Legionella spp. in water samples as a means of overriding the PCR inhibitors without loss of sensitivity. The seminested PCR assay utilized primers to amplify the 16S rRNA gene (LEG primers) of 39 Legionella spp. The assay was specific to legionellae, and the sensitivity was 1 fg of extracted Legionella DNA in laboratory examination. To evaluate the feasibility and sensitivity of the PCR assay in identifying the presence of legionellae, it was used to survey Legionella contamination in the water of 49 cooling towers of 32 hospitals. A commercially available EnviroAmp Legionella kit and a culture method were also used in the survey for comparison with the seminested PCR assay. The detection rates of legionellae in the samples were 91.8% (45 of 49) by the PCR assay and 79.5% (39 of 49) by the culture method. The EnviroAmp kit revealed that 30.6% of the water samples (15 of 49) contained inhibitors of the PCR amplification. However, the seminested PCR assay could produce the Legionella-specific DNA bands in 14 of the 15 samples. Although 8 of the 14 samples were positive in the first-step PCR, 6 of the 14 samples became positive in the second-step PCR. These results suggest that the effect of PCR inhibitors in samples, if any, can be reduced because of the dilution of the sample in the second-step PCR and that sensitivity of detection can be increased by the second-step PCR. Thus, the seminested PCR assay with LEG primers to amplify the 16S rRNA gene of 39 Legionella spp. was a practical and sensitive method to detect Legionella spp. in water samples.  相似文献   

13.
Aims:  In vitro experiments were undertaken to evaluate biocide formulations commonly used in cooling water systems against protozoa previously isolated from cooling towers. The investigations evaluated the efficacy of these formulations against amoebic cysts and trophozoites.
Methods and Results:  Laboratory challenges against protozoa isolated from cooling towers using chlorine, bromine and isothiazolinone biocides showed that all were effective after 4 h. The presence of molybdate and organic phosphates resulted in longer kill times for bromine and isothiazolinones. All treatments resulted in no detectable viable protozoa after 4 h of exposure.
Conclusions:  The chemical disinfection of planktonic protozoa in cooling water systems is strongly influenced by the residence time of the formulation and less so by its active constituent. Bromine and isothiazolinone formulations may require higher dosage of concentrations than currently practiced if used in conjunction with molybdate- and phosphate-based scale/corrosion inhibitors.
Significance and Impact of the Study:  Cooling water systems are complex microbial ecosystems in which predator–prey relationships play a key role in the dissemination of Legionella . This study demonstrated that at recommended dosing concentrations, biocides had species-specific effects on environmental isolates of amoebae that may act as reservoirs for Legionella multiplication in cooling water systems.  相似文献   

14.
15.
Genotypic variability and clonal persistence are important concepts in molecular epidemiology as they facilitate the search for the source of sporadic cases or outbreaks of legionellosis. We studied the genotypic variability and persistence of Legionella pulsed-field gel electrophoresis (PFGE) patterns over time (period > 6 months) in 34 positive cooling towers from two different areas. In area A, radius of 70 km, 52 indistinguishable PFGE patterns were differentiated among the 27 cooling towers. In 13 cooling towers we observed ≥ 2 PFGE patterns. Each cooling tower had its own indistinguishable Legionella PFGE pattern which was not shared with any other cooling tower. In area B, radius of 1 km, 10 indistinguishable PFGE patterns were obtained from the seven cooling towers. In four, we observed ≥ 2 PFGE patterns. Three of these 10 indistinguishable PFGE patterns were shared by more than one cooling tower. In 27 of 34 cooling towers the same PFGE pattern was recovered after 6 months to up to 5 years of follow-up. The large genotypic diversity of Legionella observed in the cooling towers aids in the investigation of community outbreaks of Legionnaires' disease. However, shared patterns in small areas may confound the epidemiological investigation. The persistence of some PFGE patterns in cooling towers makes the recovery of the Legionella isolate causing the outbreak possible over time.  相似文献   

16.
Free-living amoebae (FLA) are ubiquitous organisms that have been isolated from various domestic water systems, such as cooling towers and hospital water networks. In addition to their own pathogenicity, FLA can also act as Trojan horses and be naturally infected with amoeba-resisting bacteria (ARB) that may be involved in human infections, such as pneumonia. We investigated the biodiversity of bacteria and their amoebal hosts in a hospital water network. Using amoebal enrichment on nonnutrient agar, we isolated 15 protist strains from 200 (7.5%) samples. One thermotolerant Hartmannella vermiformis isolate harbored both Legionella pneumophila and Bradyrhizobium japonicum. By using amoebal coculture with axenic Acanthamoeba castellanii as the cellular background, we recovered at least one ARB from 45.5% of the samples. Four new ARB isolates were recovered by culture, and one of these isolates was widely present in the water network. Alphaproteobacteria (such as Rhodoplanes, Methylobacterium, Bradyrhizobium, Afipia, and Bosea) were recovered from 30.5% of the samples, mycobacteria (Mycobacterium gordonae, Mycobacterium kansasii, and Mycobacterium xenopi) were recovered from 20.5% of the samples, and Gammaproteobacteria (Legionella) were recovered from 5.5% of the samples. No Chlamydia or Chlamydia-like organisms were recovered by amoebal coculture or detected by PCR. The observed strong association between the presence of amoebae and the presence of Legionella (P < 0.001) and mycobacteria (P = 0.009) further suggests that FLA are a reservoir for these ARB and underlines the importance of considering amoebae when water control measures are designed.  相似文献   

17.
The occurrence and viable counts of Legionella pneumophila in acid-treated water samples of 62 cooling towers on the main island of Japan were determined by inoculating them onto plates of Wadowsky-Yee-Okuda (WYO) agar medium. WYO plate cultures of 39 (63%) of the samples yielded L. pneumophila with viable counts ranging from 10 to 10(4) colony-forming units per 100 ml. Of the L. pneumophila isolates, 157 were serologically identified as serogroup 1, and the remaining 21 were agglutinated by serogroup 3 (2 strains) and serogroup 6 (19 strains) antisera. In each culture-positive water sample, the pH and the number of other bacteria were found not be statistically significantly correlated with the viable counts of L. pneumophila. However, a higher rate of recovery of L. pneumophila was obtained with the water samples with a smaller number of other bacteria. Practical use of commercially available antialgal or antimicrobial agents was found not to be significantly effective for controlling the occurrence and growth of L. pneumophila in cooling tower water.  相似文献   

18.
Investigation of epidemic outbreaks of Legionnaires disease by Center for Disease Control personnel has resulted in the isolation of Legionella pneumophila from water in the air-conditioning cooling towers or evaporative condensers at the site of the outbreak. It is suspected that improperly maintained open, recirculating water systems may play a role in the growth and dissemination of this pathogen. The objective of this study was to determine the antimicrobial activity of three chemically different, commercially available, cooling tower microbicides against L. pneumophila. Using two in vitro test systems, a combination of N-alkyl dimethyl benzyl ammonium chloride and bis (tri-n-butyltin) oxide was found to kill L. pneumophila at a concentration 25 times less than the minimum recommended use concentration, whereas N-alkyl 1,3-propanediamine and methylene bis (thiocyanate) were active at concentrations equal to or greater than the concentrations recommended for use by the manufacturer.  相似文献   

19.
Quantitative Legionella PCRs targeting the 16S rRNA gene (specific for the genus Legionella) and the mip gene (specific for the species Legionella pneumophila) were applied to a total of 223 hot water system samples (131 in one laboratory and 92 in another laboratory) and 37 cooling tower samples (all in the same laboratory). The PCR results were compared with those of conventional culture. 16S rRNA gene PCR results were nonquantifiable for 2.8% of cooling tower samples and up to 39.1% of hot water system samples, and this was highly predictive of Legionella CFU counts below 250/liter. PCR cutoff values for identifying hot water system samples containing >10(3) CFU/liter legionellae were determined separately in each laboratory. The cutoffs differed widely between the laboratories and had sensitivities from 87.7 to 92.9% and specificities from 77.3 to 96.5%. The best specificity was obtained with mip PCR. PCR cutoffs could not be determined for cooling tower samples, as the results were highly variable and often high for culture-negative samples. Thus, quantitative Legionella PCR appears to be applicable to samples from hot water systems, but the positivity cutoff has to be determined in each laboratory.  相似文献   

20.
A preliminary survey of water systems in hospitals and hotels showed that Legionella pneumophila may be found in water storage and distribution systems as well as in the recirculating cooling water of air-conditioning plants. Altogether 42 isolates of L pneumophila were made from 31 establishments, six of which were associated with cases of legionnaires'' disease but in 25 of which there was no known association with disease. In the six establishments implicated epidemiologically as the source of legionnaires'' disease, these organisms were found in each of their water-distribution systems and also in the cooling water from each of the three with cooling towers. In establishments not associated with cases, water from three out of nine cooling towers, four out of 24 taps or showers, and one out of 15 storage tanks was found to contain legionellae. The organisms were isolated by guinea-pig inoculation and subsequent culture of their peritoneal fluid, liver, and spleen. Finding L pneumophila in water systems in the absence of cases of legionnaires'' disease should not at present be an indication for attempts at eradication.  相似文献   