首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The response of a tissue-equivalent proportional counter (TEPC) to different ions having a similar linear energy transfer (LET) has been studied. Three ions, 14N, 20Ne and 28Si, were investigated using the HIMAC accelerator at the National Institute of Radiological Sciences at Chiba, Japan. The calculated linear energy transfer (LET( infinity )) of all ions was 44 +/- 2 keV/microm at the sensitive volume of the TEPC. A particle spectrometer was used to record the charge and position of each incident beam particle. This enabled reconstruction of the location of the track as it passed though the TEPC and ensured that the particle survived without fragmentation. The spectrum of energy deposition events in the TEPC could be evaluated as a function of trajectory through the TEPC. The data indicated that there are many events from particles that did not pass through the sensitive volume. The fraction of these events increased as the energy of the particle increased due to changes in the maximum energy of the delta rays. Even though the LET of the incident particles was nearly identical, the frequency-averaged lineal energy, y(F), as well as the dose-averaged lineal energy, y(D), varied with the velocity of the incident particle. However, both values were within 15% of LET in all cases.  相似文献   

2.
Determinations of the LET distribution, phi(L), of charged particles within a spacecraft in low-Earth orbit have been made. One method used a cylindrical tissue-equivalent proportional counter (TEPC), with the assumption that for each measured event, lineal energy, y, is equal to LET and thus phi(L) = phi(y). The other was based on the direct measurement of LETs for individual particles using a charged-particle telescope consisting of position-sensitive silicon detectors called RRMD-III. There were differences of up to a factor of 10 between estimates of phi(L) using the two methods on the same mission. This caused estimates of quality factor to vary by a factor of two between the two methods.  相似文献   

3.
The radiation environment on board the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 particles are considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPCs) are used as active dosimeters on manned space flights. These TEPCs are further used to determine the average quality factor for each space mission. A TEPC simulating a 1-microm-diameter sphere of tissue was exposed as part of a particle spectrometer to (56)Fe particles at energies from 200-1000 MeV/nucleon. The response of TEPCs in terms of mean lineal energy, y(F), and dose mean lineal energy, y(D), as well as the energy deposited at different impact parameters through the detector was determined for six different incident energies of (56)Fe particles in this energy range. Calculations determined that charged-particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model, and the results were compared to experimental data.  相似文献   

4.
The paper presents a theoretical model for the response of a tissue-equivalent proportional counter (TEPC) irradiated with charged particles. Heavy ions and iron ions in particular constitute a significant part of radiation in space. TEPCs are used for all space shuttle and International Space Station (ISS) missions to estimate the dose and radiation quality (in terms of lineal energy) inside spacecraft. The response of the tissue-equivalent proportional counters shows distortions at the wall/cavity interface. In this paper, we present microdosimetric investigation using Monte Carlo track structure calculations to simulate the response of a TEPC to charged particles of various LET (1 MeV protons, 2.4 MeV alpha particles, 46 MeV/nucleon 20Ne, 55 MeV/nucleon 20Ne, 45 MeV/nucleon 40Ar, and 1.05 GeV/nucleon 56Fe). Data are presented for energy lost and energy absorbed in the counter cavity and wall. The model calculations are in good agreement with the results of Rademacher et al. (Radiat. Res. 149, 387-389, 1998), including the study of the interface between the wall and the sensitive region of the counter. It is shown that the anomalous response observed at large event sizes in the experiment is due to an enhanced entry of secondary electrons from the wall into the gas cavity.  相似文献   

5.
A modified analytical expression is proposed for the revised quality factor that has been suggested by a liaison group of ICRP and ICRU. With this modification one obtains, for sparsely ionizing radiation, a quality factor which is proportional to the dose average of lineal energy, y. It is shown that the proposed relation between the quality factor and lineal energy can be translated into a largely equivalent dependence on LET. The choice between the reference parameters LET or y is therefore a secondary problem in an impending revision of the quality factor.  相似文献   

6.
In this paper we present an investigation of the electron spin resonance (ESR) line shape of ammonium tartrate (AT) dosimeters exposed to radiation with different linear energy transfer (LET). We exposed our dosimeters to gamma-ray photons ((60)Co), 7 MeV and 14 MeV initial energy electrons, and 19.3 MeV initial energy protons. The differences in the power saturation behavior of ESR spectra of AT irradiated with photons, electrons and protons could be correlated to the effective LET of the radiation beams. We analyzed the behavior of peak-to-peak amplitude as a function of microwave power, and we developed a fitting procedure that permits us to obtain the dependence of the homogeneity parameter of the line shape on the LET of the radiation using the Castner saturation theory. This simple procedure allows us to distinguish the LET of the radiation beam.  相似文献   

7.
Delta-ray transport is important in microdosimetric studies, and how Monte Carlo models handle delta electrons using condensed histories is important for accurate simulation. The purpose of this study was to determine how well FLUKA can simulate energy deposition spectra in a tissue-equivalent proportional counter (TEPC) and produce a reliable estimate of delta-ray events produced when a TEPC is exposed to high-energy heavy ions (HZE) like those in the galactic cosmic-ray (GCR) environment. A 1.27-cm spherical TEPC with a low-pressure gas simulating a 1-μm site, typical of the one flown on the ISS, was constructed in FLUKA, and its response was compared to experimental data for an (56)Fe-ion beam at 360 MeV/nucleon. Several narrow beams at different impact parameters were used to explain the response of the same detector exposed to a uniform field of radiation. Additionally, the effect that wall thickness had on the response of the TEPC and the range of delta rays in the tissue-equivalent (TE) wall material was investigated, and FLUKA produced the expected wall effect for primary particles passing outside the sensitive volume. A final comparison to experimental data was made for the simulated TEPCs exposed to various broad beams in the energy range of 200-1000 MeV/nucleon. FLUKA overestimated energy deposition in the gas volume in all cases. The FLUKA results differed from the experimental data by an average of 25.2% for y(F) and 12.4% for y(D). It is suggested that this difference can be reduced by adjusting the FLUKA default ionization potential and density correction factors. Accurate transport codes are desirable because of the high cost of beam time for experimental evaluation of energy deposition spectra produced by HZE ions and the flexibility that calculations offer in the TEPC engineering and design process.  相似文献   

8.
Track structure in DNA irradiated with heavy ions   总被引:1,自引:0,他引:1  
The spatial properties of trapped radicals produced in heavy-ion-irradiated solid DNA at 77 K have been probed using pulsed electron paramagnetic double resonance (PELDOR or DEER) techniques. Salmon testes DNA hydrated to 12 water molecules per nucleotide was irradiated with 40Ar ions of energy 100 MeV/nucleon and LET ranging from 300 to 400 keV/microm. Irradiated samples were maintained at cryogenic temperature at all times. PELDOR measurements were made using a refocused echo detection sequence that allows dipolar interaction between trapped radicals to be observed. The EPR spectrum is attributed to electron loss/gain DNA base radicals and neutral carbon-centered radicals that likely arise from sugar damage. We find a radical concentration of 13.5 x 10(18) cm(-3) in the tracks and a track radius of 6.79 nm. The cross section of these tracks is 144 nm2, yielding a lineal radical density of 2.6 radicals/nm. Based on the yields determined previously for particles having calculated LET values of 300-400 keV/microm and our measured lineal density, we obtain an LET of 270 keV/microm, which is in good agreement with the calculated range of values. These measurements of radical density and spatial extent provide the first direct experimental determination of track characteristics in irradiated DNA.  相似文献   

9.
In proton therapy, secondary fragments are created in nuclear interactions of the beam with the target nuclei. The secondary fragments have low kinetic energies and high atomic numbers as compared to primary protons. Fragments have a high LET and deposit all their energy close to the generation point. For their characteristics, secondary fragments can alter the dose distribution and lead to an increase of RBE for the same delivered physical dose. Moreover, the radiobiological impact of target fragmentation is significant mostly in the region before the Bragg peak, where generally healthy tissues are present, and immediately after Bragg peak. Considering the high biological impact of those particles, especially in the case of healthy tissues or organs at risk, the inclusion of target fragmentation processes in the dose calculation of a treatment planning system can be relevant to improve the treatment accuracy and for this reason it is one of the major tasks of the MoVe IT project.In this study, Monte Carlo simulations were employed to fully characterize the mixed radiation field generated by target fragmentation in proton therapy. The dose averaged LET has been evaluated in case of a Spread Out Bragg Peak (SOBP). Starting from LET distribution, RBE has been evaluated with two different phenomenological models. In order to characterize the mixed radiation field, the production cross section has been evaluated by means of the FLUKA code. The future development of present work is to generate a MC database of fragments fluence to be included in TPS.  相似文献   

10.
This study was initiated following conclusions from earlier experimental work, performed in a low-energy carbon ion beam, indicating a significant LET dependence of the response of a PTW-60019 microDiamond detector. The purpose of this paper is to present a comparison between the response of the same PTW-60019 microDiamond detector and an IBA Roos-type ionization chamber as a function of depth in a 62 MeV proton beam. Even though proton beams are considered as low linear energy transfer (LET) beams, the LET value increases slightly in the Bragg peak region. Contrary to the observations made in the carbon ion beam, in the 62 MeV proton beam good agreement is found between both detectors in both the plateau and the distal edge region. No significant LET dependent response of the PTW-60019 microDiamond detector is observed consistent with other findings for proton beams in the literature, despite this particular detector exhibiting a substantial LET dependence in a carbon ion beam.  相似文献   

11.
Accelerated helium ions with mean energies at the target location of 3-7 MeV were used to simulate alpha-particle radiation from radon daughters. The experimental setup and calibration procedure allowed determination of the helium-ion energy distribution and dose in the nuclei of irradiated cells. Using this system, the induction of DNA double-strand breaks and their spatial distributions along DNA were studied in irradiated human fibroblasts. It was found that the apparent number of double-strand breaks as measured by a standard pulsed-field gel assay (FAR assay) decreased with increasing LET in the range 67-120 keV/microm (corresponding to the energy of 7-3 MeV). On the other hand, the generation of small and intermediate-size DNA fragments (0.1-100 kbp) increased with LET, indicating an increased intratrack long-range clustering of breaks. The fragment size distribution was measured in several size classes down to the smallest class of 0.1-2 kbp. When the clustering was taken into account, the actual number of DNA double-strand breaks (separated by at least 0.1 kbp) could be calculated and was found to be in the range 0.010-0.012 breaks/Mbp Gy(-1). This is two- to threefold higher than the apparent yield obtained by the FAR assay. The measured yield of double-strand breaks as a function of LET is compared with theoretical Monte Carlo calculations that simulate the track structure of energy depositions from helium ions as they interact with the 30-nm chromatin fiber. When the calculation is performed to include fragments larger than 0.1 kbp (to correspond to the experimental measurements), there is good agreement between experiment and theory.  相似文献   

12.
A standardized dichlorofluorescin (DCF) fluorometric assay capable of measuring radiation-induced oxidative stress was used to determine the effectiveness of protons and high-mass, high-atomic number (Z) and high-energy (HZE) particles to produce oxidative stress in vitro. Protons were found to be about equally as effective as X rays in the generation of oxidative stress in cultured cells. However, 56Fe-ion beams with energies of 1 GeV/nucleon and 5 GeV/nucleon were less effective than X rays or gamma rays in inducing dichlorofluorescin (DCFH) oxidation. The relatively lower slope values for the dose responses of HZE-particle radiation-induced DCFH oxidation indicate that the sensitivity of the DCF fluorometric assay is probably dependent on the linear energy transfer (LET) of the radiation beam.  相似文献   

13.
Introduction: Cyclotron-based proton therapy facilities use an energy degrader of variable thickness to deliver beams of the different energies required by a patient treatment plan; scattering and straggling in the degrader give rise to an inherent emittance increase and subsequent particle loss in the downstream energy-selection system (ESS). Here we study alternative graphite degrader geometries and examine with Monte-Carlo simulations the induced emittance growth and consequent particle transmission.Methods: We examined the conventional multiple-wedge degrader used in the Paul Scherrer Institute PROSCAN proton therapy system, the equivalent parallel-sided degrader, and a single block degrader of equivalent thickness. G4Beamline Monte-Carlo tracking of protons was benchmarked against measurements of the existing degrader for proton energies from 75 to 230 MeV, and used to validate simulations of the alternative geometries.Results: Using a careful calculation of the beam emittance growth, we determined that a single-block degrader placed close to the collimators of the ESS is expected to deliver significantly larger transmission, up to 17% larger at 150 MeV. At the lowest deliverable of 75 MeV there is still a clear improvement in beam transmission.Conclusions: Whilst dose rates are not presently limited on the PROSCAN system at higher energies, a single-block degrader offers the ability to access either lower energies for treatment or a larger dose rate at 75 MeV in case transmission optimisation is desired. Single-block degraders should be considered for the delivery of low-energy protons from a cyclotron-based particle therapy system.  相似文献   

14.
The calculations presented compared the performances of two Monte Carlo codes used for the estimation of microdosimetric quantities: Positive Ion Track Structure code (PITS) and a main user code based on the PENetration and Energy Loss of Positrons and Electrons code (PENELOPE-2000). Event-by-event track structure codes like PITS are believed to be superior for microdosimetric applications, and they are written for this purpose. PITS tracks electrons in water down to 10 eV. PENELOPE is one of the few general-purpose codes that can simulate random electron-photon showers in any material for energies from 100 eV to 1 GeV. The model used in the comparison is a water cylinder with an internal scoring geometry made of spheres 1 microm in diameter where the scoring quantities are calculated. The source is a 25 keV electron pencil beam impinging normally on the sphere surface. This work shows only the lineal energy y and spectra graphical presentation as a function of y since for microdosimetry and biology applications, and for discussion of radiation quality in general, these results are more appropriate. The computed PENELOPE results are in agreement with those obtained with the PITS code and published previously in this journal. This paper demonstrates PENELOPE's usefulness at low energies and for small geometries. What is still needed are experimental results to confirm these analyses.  相似文献   

15.
Cell survival, mutations and chromosomal effects were studied in primary human lymphocytes exposed in G0 phase to a proton beam with an incident energy of 0.88 MeV (incident LET of 28 keV/microm) in the dose range 0.125-2 Gy. The curves for survival and mutations at the hypoxanthine-guanine phosphoribosyl transferase locus were obtained by fitting the experimental data to linear and linear-quadratic equations, respectively. In the dose interval 0-1.5 Gy, the alpha parameters of the curves were 0.42/Gy and 3.6 x 10(-6) mutants/Gy, respectively. The mutation types at the HPRT locus were analyzed by multiplex-PCR in 94 irradiated and 41 nonirradiated clones derived from T lymphocytes from five healthy donors. All clones showed a normal multiplex-PCR pattern and were classified as point mutations. Chromosome aberration data were fitted as a linear function of dose (alpha = 0.62 aberrations per cell Gy(-1)). By irradiating G0 lymphocytes from a single subject with 28 keV/microm protons and gamma rays, an RBE of 6.07 was obtained for chromosome aberrations. An overinvolvement of chromosome 9 relative to chromosome 7 was found in chromosome breaks after chromosome painting analysis.  相似文献   

16.
The LET-RBE spectra for cell killing for cultured mammalian cells exposed to accelerated heavy ions were investigated to design a spread-out Bragg peak beam for cancer therapy at HIMAC, National Institute of Radiological Sciences, Chiba, prior to clinical trials. Cells that originated from a human salivary gland tumor (HSG cells) as well as V79 and T1 cells were exposed to (3)He-, (12)C- and (20)Ne-ion beams with an LET ranging from approximately 20-600 keV/micrometer under both aerobic and hypoxic conditions. Cell survival curves were fitted by equations from the linear-quadratic model and the target model to obtain survival parameters. RBE, OER, alpha and D(0) were analyzed as a function of LET. The RBE increased with LET, reaching a maximum at around 200 keV/micrometer, then decreased with a further increase in LET. Clear splits of the LET-RBE or -OER spectra were found among ion species and/or cell lines. At a given LET, the RBE value for (3)He ions was higher than that for the other ions. The position of the maximum RBE shifts to higher LET values for heavier ions. The OER value was 3 for X rays but started to decrease at an LET of around 50 keV/micrometer, passed below 2 at around 100 keV/micrometer, and then reached a minimum above 300 keV/micrometer, but the values remained greater than 1. The OER was significantly lower for (3)He ions than the others.  相似文献   

17.
Summary The influence of neutron collimation on the shape of energy deposition spectra was investigated using a spherical walled proportional counter. Experimental dose averaged lineal energies were obtained and compared with theoretical values. The fractions of total absorbed dose corresponding to various intervals of lineal energies were also deduced from the measured distributions.Contribution No. 1289 of the Biology Programme, Directorate General XII of the Commission of the European Communities  相似文献   

18.
The absorption spectrum of the main antenna complex of photosystem II, LHCII, has been modeled using, as starting points, the chlorophyll (chl) atomic coordinates as obtained by the LHCII crystal analysis [Liu, Z., Yan, H., Wang, K., Kuang, T., Zhang, J., Gui, L., An, X., and Chang, W. (2004) Nature 428, 287-292] of three different trimers. The chl site Q(y) transition energies have been obtained in terms of the chl macrocycle deformations influencing the energy level of the chl frontier orbitals. Using these chl site transition energy values and the entire set of interaction energies, calculated in the ideal dipole approximation, the complete Hamiltonians for the three LHCII trimers have been written and the full set of 42 eigenstates of each LHCII trimer have been calculated. With the 42 transition energies and transition dipole strengths, either unperturbed or associated to the eigenstates, the LHCII Q(y) absorption spectrum has been calculated using a chl absorption band shape. These calculations have been performed both in vacuo and in the presence of a medium. Despite the number of approximations, a good correlation with the measured absorption spectrum of a LHCII preparation is obtained. This analysis shows that, although a substantial C3 symmetry of the LHCII trimer in terms of both chl-chl distances and interaction energies is present, a marked variation among monomer subsets of site transition energies is estimated. This leads to a C3 symmetry breaking in the unperturbed chl site transition energies set and, consequently, in the trimer eigenstates. It is also concluded that interactions among chlorophylls do not significantly modify the light absorption role of LHCII in plant leaves.  相似文献   

19.
The extent of hydroxyl radical mediated cell inactivation was measured for a variety of particle beams ranging from 8.5 Me V/u neon ions to 570 Me V/u argon ions. In general, the fraction of the total radiosensitivity caused by OH decreases from close to 60 per cent at low ionization density or low linear energy transfer (low LET) to close to 25 per cent at high LET for aerobically irradiated mammalian cells. The extent of OH induced cell lethality can be explained in terms of LET infinity only for low energy or low atomic number particles where fragmentations and complicated track structures do not contaminate the characteristic particle LET. For example, at a calculated LET infinity of 100 ke V/micron, the OH mediated fraction of the total radiation damage is about 25 per cent for low energy carbon but close to 40 per cent for high energy carbon ions. For low energy charged nuclei of approximately the same energy, as the 5.4-13.4 MeV/u He, Li, C and Ne ions in this report, there is a predictable diminution of the OH mediated effect with increasing LET infinity; however, the biological effect cannot be predicted accurately from calculated LET infinity values for high energy particle irradiation, nor indeed from a variety of low energy charged particles of quite different energies (incident velocities). This illustrates the unsuitability of using LET as a unifying parameter, except under specific circumstances. As more is learned about the energy deposition for energized charged particles in terms of track structure (core and penumbra), it may be possible to characterize the radiobiological data with a better physical parameter than LET infinity.  相似文献   

20.
The abundance, identities, and degradation abilities of indigenous polychlorinated biphenyl (PCB)-degrading bacteria associated with five species of mature trees growing naturally in a contaminated site were investigated to identify plants that enhance the microbial PCB degradation potential in soil. Culturable PCB degraders were associated with every plant species examined in both the rhizosphere and root zone, which was defined as the bulk soil in which the plant was rooted. Significantly higher numbers of PCB degraders (2.7- to 56.7-fold-higher means) were detected in the root zones of Austrian pine (Pinus nigra) and goat willow (Salix caprea) than in the root zones of other plants or non-root-containing soil in certain seasons and at certain soil depths. The majority of culturable PCB degraders throughout the site and the majority of culturable PCB degraders associated with plants were identified as members of the genus Rhodococcus by 16S rRNA gene sequence analysis. Other taxa of PCB-degrading bacteria included members of the genera Luteibacter and Williamsia, which have not previously been shown to include PCB degraders. PCB degradation assays revealed that some isolates from the site have broad congener specificities; these isolates included one Rhodococcus strain that exhibited degradation abilities similar to those of Burkholderia xenovorans LB400. Isolates with broad congener specificity were widespread at the site, including in the biostimulated root zone of willow. The apparent association of certain plant species with increased abundance of indigenous PCB degraders, including organisms with outstanding degradation abilities, throughout the root zone supports the notion that biostimulation through rhizoremediation is a promising strategy for enhancing PCB degradation in situ.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号