首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
The development of phase contrast methods for diagnostic x-ray imaging is inspired by the potential of seeing the internal structures of the human body without the need to deposit any harmful radiation. An efficient class of x-ray phase contrast imaging and scatter correction methods share the idea of using structured illumination in the form of a periodic fringe pattern created with gratings or grids. They measure the scatter and distortion of the x-ray wavefront through the attenuation and deformation of the fringe pattern via a phase stepping process. Phase stepping describes image acquisition at regular phase intervals by shifting a grating in uniform steps. However, in practical conditions the actual phase intervals can vary from step to step and also spatially. Particularly with the advent of electromagnetic phase stepping without physical movement of a grating, the phase intervals are dependent upon the focal plane of interest. We describe a demodulation algorithm for phase stepping at arbitrary and position-dependent (APD) phase intervals without assuming a priori knowledge of the phase steps. The algorithm retrospectively determines the spatial distribution of the phase intervals by a Fourier transform method. With this ability, grating-based x-ray imaging becomes more adaptable and robust for broader applications.  相似文献   

2.

Purpose

To assess whether grating-based X-ray dark-field imaging can increase the sensitivity of X-ray projection images in the diagnosis of pulmonary emphysema and allow for a more accurate assessment of emphysema distribution.

Materials and Methods

Lungs from three mice with pulmonary emphysema and three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Median signal intensities of transmission (T), dark-field (V) and a combined parameter (normalized scatter) were compared between emphysema and control group. To determine the diagnostic value of each parameter in differentiating between healthy and emphysematous lung tissue, a receiver-operating-characteristic (ROC) curve analysis was performed both on a per-pixel and a per-individual basis. Parametric maps of emphysema distribution were generated using transmission, dark-field and normalized scatter signal and correlated with histopathology.

Results

Transmission values relative to water were higher for emphysematous lungs than for control lungs (1.11 vs. 1.06, p<0.001). There was no difference in median dark-field signal intensities between both groups (0.66 vs. 0.66). Median normalized scatter was significantly lower in the emphysematous lungs compared to controls (4.9 vs. 10.8, p<0.001), and was the best parameter for differentiation of healthy vs. emphysematous lung tissue. In a per-pixel analysis, the area under the ROC curve (AUC) for the normalized scatter value was significantly higher than for transmission (0.86 vs. 0.78, p<0.001) and dark-field value (0.86 vs. 0.52, p<0.001) alone. Normalized scatter showed very high sensitivity for a wide range of specificity values (94% sensitivity at 75% specificity). Using the normalized scatter signal to display the regional distribution of emphysema provides color-coded parametric maps, which show the best correlation with histopathology.

Conclusion

In a murine model, the complementary information provided by X-ray transmission and dark-field images adds incremental diagnostic value in detecting pulmonary emphysema and visualizing its regional distribution as compared to conventional X-ray projections.  相似文献   

3.

Purpose

Volume flow rate (VFR) measurements based on phase contrast (PC)-magnetic resonance (MR) imaging datasets have spatially varying bias due to eddy current induced phase errors. The purpose of this study was to assess the impact of phase errors in time averaged PC-MR imaging of the cerebral vasculature and explore the effects of three common correction schemes (local bias correction (LBC), local polynomial correction (LPC), and whole brain polynomial correction (WBPC)).

Methods

Measurements of the eddy current induced phase error from a static phantom were first obtained. In thirty healthy human subjects, the methods were then assessed in background tissue to determine if local phase offsets could be removed. Finally, the techniques were used to correct VFR measurements in cerebral vessels and compared statistically.

Results

In the phantom, phase error was measured to be <2.1 ml/s per pixel and the bias was reduced with the correction schemes. In background tissue, the bias was significantly reduced, by 65.6% (LBC), 58.4% (LPC) and 47.7% (WBPC) (p < 0.001 across all schemes). Correction did not lead to significantly different VFR measurements in the vessels (p = 0.997). In the vessel measurements, the three correction schemes led to flow measurement differences of -0.04 ± 0.05 ml/s, 0.09 ± 0.16 ml/s, and -0.02 ± 0.06 ml/s. Although there was an improvement in background measurements with correction, there was no statistical difference between the three correction schemes (p = 0.242 in background and p = 0.738 in vessels).

Conclusions

While eddy current induced phase errors can vary between hardware and sequence configurations, our results showed that the impact is small in a typical brain PC-MR protocol and does not have a significant effect on VFR measurements in cerebral vessels.  相似文献   

4.
Super-paramagnetic microbeads are widely used for cell isolation. Evaluation of the binding affinity of microbeads to cells using optical microscopy has been limited by its small scope. Here, magnetic property of microbeads was first investigated by using synchrotron radiation (SR) in-line x-ray phase contrast imaging (PCI). The cell line mouse LLC (Lewis lung carcinoma) was selected for cell adhesion studies. Targeted microbeads were prepared by attaching anti-VEGFR2 (vascular endothelial growth factor receptor-2) antibody to the shell of the microbeads. The bound microbeads were found to better adhere to LLC cells than unbound ones. PCI dynamically and clearly showed the magnetization and demagnetization of microbeads in PE-50 tube. The cells incubated with different types of microbeads were imaged by PCI, which provided clear and real-time visualization of the cell isolation. Therefore, PCI might be considered as a novel and efficient tool for further cell isolation studies.  相似文献   

5.
Off-axis illumination plasmonic lens (OAIPL) is proposed and demonstrated to improve the imaging contrast in non-contacted application manner. The spatial Fourier components of light transmitted through the nano-patterns are greatly enhanced in the imaging process by shifting the wave vectors with high numerical aperture off-axis illumination. On the other hand, a reflector in the image area helps to tailor the ratio between electric field components in the tangential and normal directions. These two effects resultantly deliver significant improvement of imaging performance, including enhanced resolution, imaging contrast, and elongation of air gap thickness. In comparison to the case of normal illumination, the air gap thickness for 30 and 60 nm half-pitch resolution is extended to 25 and 100 nm by OAIPL with numerical aperture (NA)?=?1.55, respectively.  相似文献   

6.
Conventional radiology is performed by means of digital detectors, with various types of technology and different performance in terms of efficiency and image quality. Following the arrival of a new digital detector in a radiology department, all the staff involved should adapt the procedure parameters to the properties of the detector, in order to achieve an optimal result in terms of correct diagnostic information and minimum radiation risks for the patient. The aim of this study was to develop and validate a software capable of simulating a digital X-ray imaging system, using graphics processing unit computing. All radiological image components were implemented in this application: an X-ray tube with primary beam, a virtual patient, noise, scatter radiation, a grid and a digital detector. Three different digital detectors (two digital radiography and a computed radiography systems) were implemented. In order to validate the software, we carried out a quantitative comparison of geometrical and anthropomorphic phantom simulated images with those acquired. In terms of average pixel values, the maximum differences were below 15%, while the noise values were in agreement with a maximum difference of 20%. The relative trends of contrast to noise ratio versus beam energy and intensity were well simulated. Total calculation times were below 3 seconds for clinical images with pixel size of actual dimensions less than 0.2 mm. The application proved to be efficient and realistic. Short calculation times and the accuracy of the results obtained make this software a useful tool for training operators and dose optimisation studies.  相似文献   

7.
Marsupials are born with immature lungs when compared to eutherian mammals and rely, to various extents, on cutaneous gas exchange in order to meet metabolic requirements. Indeed, the fat-tailed dunnart is born with lungs in the canalicular stage of development and relies almost entirely on the skin for gas exchange at birth; consequently undergoing the majority of lung development in air. Plane radiographs and computed tomography data sets were acquired using phase contrast imaging with a synchrotron radiation source for two marsupial species, the fat-tailed dunnart and the larger tammar wallaby, during the first weeks of postnatal life. Phase contrast imaging revealed that only two lung sacs contain air after the first hour of life in the fat-tailed dunnart. While the lung of the tammar wallaby was comparatively more developed, both species demonstrated massive increases in air sac number and architectural complexity during the postnatal period. In addition, both the tammar wallaby and fat-tailed dunnart had lower lung volumes and parenchymal surface areas than were expected from morphometrically determined allometric equations relating these variables to body mass during the neonatal period. However, lung volume is predicted to scale with mass as expected after the neonatal marsupial reaches a body mass of ∼1 g and no longer relies on the skin for gas exchange. Decreased lung volume in the marsupial neonate further supports the maxim that cutaneous gas exchange occurs in the marsupial neonate because the respiratory apparatus is not yet capable of meeting the gas exchange requirements of the newborn.  相似文献   

8.
It is crucial to understand the distribution of embolic agents inside target liver during and after the hepatic portal vein embolization (PVE) procedure. For a long time, the problem has not been well solved due to the radiolucency of embolic agents and the resolution limitation of conventional radiography. In this study, we first reported use of fluorescent carboxyl microspheres (FCM) as radiolucent embolic agents for embolizing hepatic portal veins. The fluorescent characteristic of FCM could help to determine their approximate location easily. Additionally, the microspheres were found to be fairly good embolizing agents for PVE. After the livers were excised and fixed, they were imaged by in-line phase contrast imaging (PCI), which greatly improved the detection of the radiolucent embolic agents as compared to absorption contrast imaging (ACI). The preliminary study has for the first time shown that PCI has great potential in the pre-clinical investigation of PVE with radiolucent embolic agents.  相似文献   

9.
Phase contrast X-ray computed tomography (PCI-CT) has been demonstrated as a novel imaging technique that can visualize human cartilage with high spatial resolution and soft tissue contrast. Different textural approaches have been previously investigated for characterizing chondrocyte organization on PCI-CT to enable classification of healthy and osteoarthritic cartilage. However, the large size of feature sets extracted in such studies motivates an investigation into algorithmic feature reduction for computing efficient feature representations without compromising their discriminatory power. For this purpose, geometrical feature sets derived from the scaling index method (SIM) were extracted from 1392 volumes of interest (VOI) annotated on PCI-CT images of ex vivo human patellar cartilage specimens. The extracted feature sets were subject to linear and non-linear dimension reduction techniques as well as feature selection based on evaluation of mutual information criteria. The reduced feature set was subsequently used in a machine learning task with support vector regression to classify VOIs as healthy or osteoarthritic; classification performance was evaluated using the area under the receiver-operating characteristic (ROC) curve (AUC). Our results show that the classification performance achieved by 9-D SIM-derived geometric feature sets (AUC: 0.96 ± 0.02) can be maintained with 2-D representations computed from both dimension reduction and feature selection (AUC values as high as 0.97 ± 0.02). Thus, such feature reduction techniques can offer a high degree of compaction to large feature sets extracted from PCI-CT images while maintaining their ability to characterize the underlying chondrocyte patterns.  相似文献   

10.
Calcraft L  Adams R  Davey N 《Bio Systems》2008,94(1-2):87-94
This study examines the performance of sparsely connected associative memory models built using a number of different connection strategies, applied to one- and two-dimensional topologies. Efficient patterns of connectivity are identified which yield high performance at relatively low wiring costs in both topologies. Networks with displaced connectivity are seen to perform particularly well. It is found that two-dimensional models are more tolerant of variations in connection strategy than their one-dimensional counterparts; though networks built with both topologies become less so as their connection density is decreased.  相似文献   

11.
Ultrasound-triggered phase transition sensitive nanodroplets with multimodal imaging functionality were prepared via premix Shirasu porous glass (SPG) membrane emulsification method. The nanodroplets with fluorescence dye DiR and SPIO nanoparticles (DiR-SPIO-NDs) had a polymer shell and a liquid perfluoropentane (PFP) core. The as-formed DiR-SPIO-NDs have a uniform size of 385±5.0 nm with PDI of 0.169±0.011. The TEM and microscopy imaging showed that the DiR-SPIO-NDs existed as core-shell spheres, and DiR and SPIO nanoparticles dispersed in the shell or core. The MTT and hemolysis studies demonstrated that the nanodroplets were biocompatible and safe. Moreover, the proposed nanodroplets exhibited significant ultrasound-triggered phase transition property under clinical diagnostic ultrasound irradiation due to the vaporization of PFP inside. Meanwhile, the high stability and R2 relaxivity of the DiR-SPIO-NDs suggested its applicability in MRI. The in vivo T2-weighted images of MRI and fluorescence images both showed that the image contrast in liver and spleen of rats and mice model were enhanced after the intravenous injection of DiR-SPIO-NDs. Furthermore, the ultrasound imaging (US) in mice tumor as well as MRI and fluorescence imaging in liver of rats and mice showed that the DiR-SPIO-NDs had long-lasting contrast ability in vivo. These in vitro and in vivo findings suggested that DiR-SPIO-NDs could potentially be a great MRI/US/fluorescence multimodal imaging contrast agent in the diagnosis of liver tissue diseases.  相似文献   

12.
13.
The electric quadrupole moment of the deuterium nucleus provides a nuclear magnetic resonance (NMR) probe of electric field gradients, and thereby of organization of tissue water. 8-17% of H2O in rat muscle and brain was replaced by D2O from 50% deuterated drinking water. The peak height of the steady-state NMR spectrum of D in muscle water was 74% lower than that of an equal concentration of D2O in liquid water. Longitudinal NMR relaxation times (T1) of D in water of muscle and brain averaged 0.092 and 0.131 sec, respectively, compared with 0.47 sec in D2O in liquid water. Transverse NMR relaxation times (T2) averaged 0.009 and 0.022 sec in D2O of muscle and brain, respectively, compared with 0.45 sec in D2O in liquid water. These differences cannot be explained by paramagnetic ions or by magnetic inhomogeneities, which leaves increased organization of tissue water as the only tenable hypothesis. Evidence was also obtained that 27% of muscle water and 13% of brain water exist as a separate fraction with T2 of D2O less than 2 × 10-3 sec, which implies an even higher degree of structure. Each of the two fractions may consist of multiple subfractions of differing structure.  相似文献   

14.
Multimodal imaging promises to revolutionize the understanding of biological processes across scales in space and time by combining the strengths of multiple imaging techniques. Fluorescent nanodiamonds (FNDs) are biocompatible, chemically inert, provide high contrast in light- and electron-based microscopy, and are versatile optical quantum sensors. Here it is demonstrated that FNDs also provide high absorption contrast in nanoscale 3D soft X-ray tomograms with a resolution of 28 nm in all dimensions. Confocal fluorescence, atomic force, and scanning electron microscopy images of FNDs inside and on the surface of PC3 cancer cells with sub-micrometer precision are correlated. FNDs are found inside ≈1 µm sized vesicles present in the cytoplasm, providing direct evidence of the active uptake of bare FNDs by cancer cells. Imaging artefacts are quantified and separated from changes in cell morphology caused by sample preparation. These results demonstrate the utility of FNDs in multimodal imaging, contribute to the understanding of the fate of FNDs in cells, and open up new possibilities for biological imaging and sensing across the nano- and microscale.  相似文献   

15.
Organic–inorganic hybrid lead halide perovskites are emerging as highly promising candidates for highly efficient thin film photovoltaics due to their excellent optoelectronic properties and low‐temperature process capability. However, the long‐term stability in ambient air still is a key issue limiting their further practical applications. Herein, the enhancement of both performance and stability of perovskite solar cells is reported by employing 2D and 3D heterostructured perovskite films with unique nanoplate/nanocrystalline morphology. The 2D/3D heterostructured perovskites combine advantages of the high‐performance lead‐based perovskite 3D CH3NH3PbI3 (MAPbI3) and the air‐stable bismuth‐based quasi‐perovskite 2D MA3Bi2I9. In the 2D/3D heterostructure, the hydrophobic MA3Bi2I9 platelets vertically situate between the MAPbI3 grains, forming a lattice‐like structure to tightly enclose the 3D MAPbI3 perovskite grains. The solar cell based on the optimal 2D/3D (9.2%) heterostructured film achieves a high efficiency of 18.97%, with remarkably reduced hysteresis and significantly improved stability. The work demonstrates that construction of 2D/3D heterostructured films by hybridizing different species of perovskite materials is a feasible way to simultaneously enhance both efficiency and stability of perovskite solar cells.  相似文献   

16.
The conversion of crystalline metal–organic frameworks (MOFs) into metal compounds/carbon hybrid nanocomposites via pyrolysis provides a promising solution to design electrocatalysts for electrochemical water splitting. However, pyrolyzing MOFs generally involves a complex high‐temperature treatment, which can destroy the coordinated surroundings within MOFs, and as a result not taking their full advantage of their electrolysis properties. Herein, a simple and room‐temperature boronization strategy is developed to convert nickel zeolite imidazolate framework (Ni‐ZIF) nanorods into ultrathin Ni‐ZIF/Ni? B nanosheets with abundant crystalline–amorphous phase boundaries. The combined experiment, and theoretical calculation results disclose that the ultrathin thickness allows fast electron transfer and ensures increased exposure of surface coordinatively unsaturated active sites while the crystalline–amorphous interface elaborately changes the potential‐determining step to energetically favorable intermediates. As a result, Ni‐ZIF/Ni? B nanosheets supported on nickel foam (NF) require overpotentials of 67 mV for the hydrogen evolution reaction and 234 mV for the oxygen evolution reaction to achieve a current density of 10 mA cm?2. Remarkably, Ni‐ZIF/Ni? B@NF as a bifunctional electrocatalyst for overall water splitting enables an alkaline electrolyzer with 10 mA cm?2 at an ultralow cell voltage of 1.54 V. The present work may open a new avenue to the design of MOF‐derived composites for electrocatalysis.  相似文献   

17.
目的:应用对比剂动力学时间分辨成像(Time Resolved Imaging of Contrast Kinetics,TRICKS)技术增强磁共振血管成像(MRangiography,MRA)及弥散加权成像(Diffusion Weighted Imaging,DWI)技术活体动态监测兔VX2肌肉肿瘤生物学生长与血管生成,探讨肿瘤血管生成与肿瘤生长的关系。方法:30只新西兰白兔,每只均在右后腿肌肉内接种VX2肿瘤细胞1×107建立肿瘤模型。分别在肿瘤接种后第4、7、10、13、16天(每个时间点6只)分别进行T1WI、T2WI、DWI、TRICKS动态增强MRA及T1WI增强延迟扫描,活体监测兔VX2肌肉肿瘤血管生成,肿瘤标本HE及CD31免疫组化染色进行验证。两位医师双盲法分别测量不同生长点肿瘤的长、短径及体积,并与大体病理标本比较;测定TRICKS增强动态MRA所能显示肿瘤血管的最小直径及形态变化;观察ADC值变化与肿瘤生长的关系。结果(:1)ADC值随着肿瘤体积的长大而逐渐增大。(2)MRI活体测定肿瘤大小与病理大体标本所测算肿瘤体积的差异无显著性。(3)TRICKS增强MRA动态显示肿瘤血管的最小...  相似文献   

18.

Purpose

To quantify short-term reproducibility (in fasting conditions) and postprandial changes after a meal in portal vein (PV) flow parameters measured with phase contrast (PC) imaging, liver diffusion parameters measured with multiple b value diffusion-weighted imaging (DWI) and liver stiffness (LS) measured with MR elastography (MRE) in healthy volunteers and patients with liver disease at 3.0 T.

Materials and Methods

In this IRB–approved prospective study, 30 subjects (11 healthy volunteers and 19 liver disease patients; 23 males, 7 females; mean age 46.5 y) were enrolled. Imaging included 2D PC imaging, multiple b value DWI and MRE. Subjects were initially scanned twice in fasting state to assess short-term parameter reproducibility, and then scanned 20 min. after a liquid meal. PV flow/velocity, LS, liver true diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (PF) and apparent diffusion coefficient (ADC) were measured in fasting and postprandial conditions. Short-term reproducibility was assessed in fasting conditions by measuring coefficients of variation (CV) and Bland-Altman limits of agreement. Differences in MR metrics before and after caloric intake and between healthy volunteers and liver disease patients were assessed.

Results

PV flow parameters, D, ADC and LS showed good to excellent short-term reproducibility in fasting state (CV <16%), while PF and D* showed acceptable and poor reproducibility (CV = 20.4% and 51.6%, respectively). PV flow parameters and LS were significantly higher (p<0.04) in postprandial state while liver diffusion parameters showed no significant change (p>0.2). LS was significantly higher in liver disease patients compared to healthy volunteers both in fasting and postprandial conditions (p<0.001). Changes in LS were significantly correlated with changes in PV flow (Spearman rho = 0.48, p = 0.013).

Conclusions

Caloric intake had no/minimal/large impact on diffusion/stiffness/portal vein flow, respectively. PC MRI and MRE but not DWI should be performed in controlled fasting state.  相似文献   

19.
Cell image segmentation plays a central role in numerous biology studies and clinical applications. As a result, the development of cell image segmentation algorithms with high robustness and accuracy is attracting more and more attention. In this study, an automated cell image segmentation algorithm is developed to get improved cell image segmentation with respect to cell boundary detection and segmentation of the clustered cells for all cells in the field of view in negative phase contrast images. A new method which combines the thresholding method and edge based active contour method was proposed to optimize cell boundary detection. In order to segment clustered cells, the geographic peaks of cell light intensity were utilized to detect numbers and locations of the clustered cells. In this paper, the working principles of the algorithms are described. The influence of parameters in cell boundary detection and the selection of the threshold value on the final segmentation results are investigated. At last, the proposed algorithm is applied to the negative phase contrast images from different experiments. The performance of the proposed method is evaluated. Results show that the proposed method can achieve optimized cell boundary detection and highly accurate segmentation for clustered cells.  相似文献   

20.
Competent social organisms will read the social signals of their peers. In primates, the face has evolved to transmit the organism''s internal emotional state. Adaptive action suggests that the brain of the receiver has co-evolved to efficiently decode expression signals. Here, we review and integrate the evidence for this hypothesis. With a computational approach, we co-examined facial expressions as signals for data transmission and the brain as receiver and decoder of these signals. First, we show in a model observer that facial expressions form a lowly correlated signal set. Second, using time-resolved EEG data, we show how the brain uses spatial frequency information impinging on the retina to decorrelate expression categories. Between 140 to 200 ms following stimulus onset, independently in the left and right hemispheres, an information processing mechanism starts locally with encoding the eye, irrespective of expression, followed by a zooming out to processing the entire face, followed by a zooming back in to diagnostic features (e.g. the opened eyes in “fear”, the mouth in “happy”). A model categorizer demonstrates that at 200 ms, the left and right brain have represented enough information to predict behavioral categorization performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号