首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.

Purpose

To examine a potential association between intraocular pressure (IOP) and cerebrospinal fluid pressure (CSFP) in a population-based setting.

Methods

The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years (range: 50–93 years). A detailed ophthalmic examination was performed. Based on a previous study with lumbar cerebrospinal fluid pressure (CSFP) measurements, CSFP was calculated as CSFP [mm Hg] = 0.44×Body Mass Index [kg/m2]+0.16×Diastolic Blood Pressure [mm Hg]–0.18×Age [Years].

Results

In multivariate analysis, IOP was associated with higher estimated CSFP (P<0.001; standardized correlation coefficient beta: 0.27; regression coefficient B: 0.20; 95% confidence interval (CI): 0.16, 0.24), after adjusting for thinner central corneal thickness (P<0.001; beta: 0.45; B: 0.04;95%CI: 0.04,0.04), smaller corneal curvature radius (P<0.001; beta:−0.11; B:−1.13;95%CI:−1.61,−0.64), shallower anterior chamber depth (P = 0.01; beta:−0.05; B:−0.33;95%CI:−0.59,−0.08) and longer axial length (P = 0.002; beta: 0.08; B: 0.20;95%CI: 0.08,0.32)), and after adjusting for the systemic parameters of higher pulse rate (P<0.001; beta: 0.08; B: 0.02;95%CI: 0.01,0.03), higher prevalence of arterial hypertension (P = 0.002; beta: 0.06; B: 0.32;95%CI: 0.12,0.53)), frequency of drinking alcohol (P = 0.02; beta: 0.04; B: 0.09;95%CI: 0.01,0.17), higher blood concentration of triglycerides (P = 0.001; beta: 0.06; B: 0.06;95%CI: 0.02,0.10) and cholesterol (P = 0.049; beta: 0.04; B: 0.08;95%CI: 0.00,0.17), and body mass index (P<0.001; beta:−0.13; B:−0.09;95%CI:−0.13,−0.06). In a parallel manner, estimated CSFP (mean: 10.8±3.7 mm Hg) was significantly associated with higher IOP (P<0.001; beta: 0.13; B: 0.18;95%CI: 0.13,0.23) after adjusting for rural region of habitation (P<0.001; beta:−0.37; B:−2.78;95%CI:−3.07,−2.48), higher systolic blood pressure (P<0.001; beta: 0.34; B: 0.06;95%CI: 0.05,0.07), higher pulse rate (P = 0.003; beta: 0.05; B: 0.02;95%CI: 0.01,0.03), taller body height (P<0.001; beta: 0.11; B: 0.05;95%CI: 0.03,0.07), higher blood concentration of cholesterol (P = 0.003; beta: 0.05; B: 0.17;95%CI: 0.06,0.28) and higher level of education (P = 0.003; beta: 0.09; B: 0.30;95%CI: 0.16,0.45).

Conclusions

IOP was positively associated with estimated CSFP after adjusting for other ocular and systemic parameters. As a corollary, higher estimated CSFP was significantly associated with higher IOP in multivariate analysis. It fits with the notion that the arterial blood pressure, estimated CSFP and IOP are physiologically correlated with each other.  相似文献   

2.

Purpose

The cerebrospinal fluid pressure (CSFP) is a major determinant of central retinal vein pressure and thus of retinal capillary pressure. We tested the hypothesis whether prevalence and severity of diabetic retinopathy are associated with CSFP.

Methods

The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years. A detailed ophthalmic examination was performed including fundus photography for the assessment of diabetic retinopathy according. Based on a previous study with lumbar cerebrospinal fluid pressure (CSFP) measurements, CSFP was calculated as CSFP[mmHg] = 0.44xBody Mass Index[kg/m2]+0.16 Diastolic Blood Pressure[mmHg]–0.18xAge[Years]−1.91.

Results

In binary regression analysis, presence of diabetic retinopathy was significantly associated with higher levels of HbA1c (P<0.001; regression coefficient B:0.25; odds ratio (OR):1.28; 95% confidence interval (CI):1.15,1.43), higher blood concentration of glucose (P<0.001; B:0.40;OR:1.49;95%CI:1.36,1.63), longer known duration of diabetes mellitus (P<0.001; B:0.14;OR:1.15; 95%CI:1.11,1.19), higher systolic blood pressure (P<0.001; B:0.03;OR:1.03;95%CI:1.02,1.04), lower diastolic blood pressure (P<0.001; B:−0.06;OR:0.94;95%CI:0.91,0.97), and higher CSFP (P = 0.002; B:0.13;OR:1.14;95%CI:1.05,1.24). Severity of diabetic retinopathy was significantly associated with higher HbA1c value (P<0.001; standardized coefficient beta: 0.19; correlation coefficient B: 0.07;95%CI:0.05,0.08), higher blood concentration of glucose (P<0.001; beta:0.18;B:0.04;95%CI:0.04,0.05), longer known duration of diabetes mellitus (P<0.001; beta:0.20;B:0.03;95%CI:0.02,0.03), lower level of education (P = 0.001; beta:−0.05;B:−0.02;95%CI:−0.03,−0.01), lower diastolic blood pressure (P = 0.002; beta:−0.08;B:−0.001;95%CI:−0.004,−0.001), higher systolic blood pressure (P = 0.006; beta:0.06;B:0.001;95%CI:0.000,0.001), and higher CSFP (P = 0.006; beta:0.06;B:0.006;95%CI:0.002,0.010).

Conclusions

Higher prevalence and severity of diabetic retinopathy were associated with higher estimated CSFP after adjusting for systemic parameters. Higher CSFP through a higher retinal vein pressure may lead to more marked retinal venous congestion and vascular leakage in diabetic retinae.  相似文献   

3.

Purpose

To examine characteristics of ocular hypertensive subjects and potential associations with estimated cerebrospinal fluid pressure (estCSFP).

Methods

The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years. Ocular hypertension was defined as intraocular pressure (IOP) >21 mmHg, normal optic nerve head appearance and normal retinal nerve fiber layer thickness. IOP was corrected for its dependence on central corneal thickness (CCT) and corneal curvature radius. Estimated CSFP was calculated as CSFP [mmHg] = 0.44×Body Mass Index [kg/m2]+0.16×Diastolic Blood Pressure [mmHg]−0.18×Age [Years]−1.91. Estimated trans-lamina cribrosa pressure difference (estTLCPD) was IOP–estCSFP.

Results

EstCSFP (10.5±3.6 mmHg versus 9.0±3.7 mmHg; P = 0.003) and estTLCPD (12.0±4.4 mmHg versus 5.4±3.8 mmHg; P<0.001) were higher in the ocular hypertensive group than in the normotensive group. In binary regression analysis, ocular hypertension was associated with increased estCSFP (P = 0.03; odds ratio (OR): 1.08; 95% confidence interval (CI): 1.01, 1.17) after adjusting for prevalence of arterial hypertension (P = 0.07; OR: 1.79; 95%CI: 0.96, 3.34), retinal nerve fiber layer thickness (P = 0.03; OR: 0.97; 95%CI: 0.95, 0.997) and blood glucose concentration (P = 0.006; OR: 1.17; 95%CI: 1.04, 1.30).

Conclusions

Ocular hypertensive subjects (with IOP correction for CCT and corneal curvature) as compared to ocular normotensive subjects had a significantly higher estCSFP in univariate analysis and in multivariate analysis. Despite of a higher estCSFP, estTLCPD was still markedly higher in ocular hypertensive eyes than in ocular normotensive eyes.  相似文献   

4.

Purpose

To examine subfoveal choroidal thickness (SFCT) in eyes with glaucoma, using enhanced depth imaging spectral domain optical coherence tomography.

Methods

The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years (range: 50–93 years). A detailed ophthalmic examination was performed including spectral-domain optical coherence tomography (SD-OCT) with enhanced depth imaging for measurement of SFCT, and assessment of fundus photographs for presence of glaucoma. In addition, the group of patients with chronic angle-closure glaucoma (ACG) from the Beijing Eye Study (n = 37) was merged with a group of patients with chronic ACG from the Tongren hospital (n = 52).

Results

Assessments of SFCT and glaucoma were available for 3232 (93.2%) subjects. After adjusting for age, axial length, gender, anterior chamber and lens thickness, SFCT was not significantly associated with presence of glaucoma (P = 0.08; regression coefficient B:−15.7). As a corollary, in logistic regression analysis with adjustment for age, axial length and intraocular pressure, presence of glaucoma was not significantly associated with SFCT (P = 0.20). If only open-angle glaucoma was considered, multivariate analysis revealed no significant association between SFCT and presence of open-angle glaucoma (P = 0.44). As a corollary, in logistic regression analysis, open-angle glaucoma was not significantly associated with SFCT (P = 0.91). In a similar manner if only ACG was taken into account, SFCT was not significantly associated with the presence of ACG (P = 0.27) in multivariate analysis. As a corollary in binary regression analysis, presence of ACG was not significantly associated with SFCT (P = 0.27).

Conclusions

In multivariate analysis with adjustment for age, axial length, gender, anterior chamber and lens thickness, neither OAG nor ACG was associated with an abnormal SFCT.  相似文献   

5.

Purpose

To assess associations of the trans-lamina cribrosa pressure difference (TLCPD) with glaucomatous optic neuropathy.

Methods

The population-based Central India Eye and Medical Study included 4711 subjects. Based on a previous study with lumbar cerebrospinal fluid pressure (CSFP) measurements, CSFP was calculated as CSFP[mmHg] = 0.44 Body Mass Index[kg/m2]+0.16 Diastolic Blood Pressure[mmHg]−0.18×Age[Years] −1.91. TLCPD was IOP–CSFP.

Results

Mean TLCPD was 3.64±4.25 mm Hg in the non-glaucomatous population and 9.65±8.17 mmHg in the glaucomatous group. In multivariate analysis, TLCPD was associated with older age (P<0.001; standardized coefficient beta:0.53; regression coefficient B:0.18; 95% confidence interval (CI):0.17, 0.18), lower body mass index (P<0.001; beta: −0.28; B: −0.36; 95%CI: −0.38, −0.31), lower diastolic blood pressure (P<0.001; beta: −0.31; B: −0.12; 95%CI: −0.13, −0.11), higher pulse (P<0.001; beta:0.05; B:0.02; 95%CI:0.01,0.2), lower body height (P = 0.02; beta: −0.02; B: −0.01; 95%CI: −0.02,0.00), higher educational level (P<0.001; beta:0.04; B:0.15; 95%CI:0.09,0.22), higher cholesterol blood concentrations (P<0.001; beta:0.04; B:0.01; 95%CI:0.01,0.01), longer axial length (P = 0.006; beta:0.03; B:0.14; 95%CI:0.04,0.24), thicker central cornea (P<0.001; beta:0.15; B:0.02; 95%CI:0.02,0.02), higher corneal refractive power (P<0.001; beta:0.07; B:0.18; 95%CI:0.13,0.23) and presence of glaucomatous optic neuropathy (P<0.001; beta:0.11; B:3.43; 95%CI:2.96,3.99). Differences between glaucomatous subjects and non-glaucomatous subjects in CSFP were more pronounced for open-angle glaucoma (OAG) than for angle-closure glaucoma (ACG) (3.0 mmHg versus 1.8 mmHg), while differences between glaucomatous subjects and non-glaucomatous subjects in IOP were higher for ACG than for OAG (8.5 mmHg versus 3.0 mmHg). Presence of OAG was significantly associated with TLCPD (P<0.001; OR:1.24; 95%CI:1.19,1.29) but not with IOP (P = 0.08; OR:0.96; 95%CI:0.91,1.00). Prevalence of ACG was significantly associated with IOP (P = 0.04; OR:1.19; 95%CI:1.01,1.40) but not with TLCPD (P = 0.92).

Conclusions

In OAG, but not in ACG, calculated TLCPD versus IOP showed a better association with glaucoma presence and amount of glaucomatous optic neuropathy. It supports the notion of a potential role of low CSFP in the pathogenesis of open-angle glaucoma.  相似文献   

6.
7.
Aim: To investigate the relationship between glaucoma and intraocular pressure (IOP), intracranial pressure (ICP), trans-laminar cribrosa pressure difference (TLCPD), and the newly proposed fractional pressure reserve (FPR). Methods: Ten articles were analyzed by meta-analysis, and subgroup analysis of three factors was conducted. Results: The patients with normal tension glaucoma (NTG) and open-angle glaucoma (OAG) have higher TLCPD and lower ICP than healthy subjects, with obvious heterogeneity. The greater heterogeneity may arise from different ICP measurements and from different countries or regions. FPR performs better than TLCPD in some ways. Conclusion: Both FPR and TLCPD can be used as indicators of NTG and OAG, and FPR is more effective than TLCPD in comparisons between different experiments or individuals.  相似文献   

8.

Purpose

To measure retinal nerve fiber layer (RNFL) thickness in a population-based setting.

Methods

In the population-based Beijing Eye Study 2011 with 3468 individuals, RNFL thickness was measured in a subgroup of 1654 (47.7%) study participants by spectral domain optical coherence tomography (iVue SD-OCT).

Results

Mean RNFL thickness was significantly (P<0.001) higher in the inferior sector (131.4±20.6 µm) than the superior sector (126.1±19.1 µm), where it was higher than in the temporal sector (79.8±12.2 µm;P<0.001), where it was higher than in the nasal sector (75.1±12.6 µm;P<0.001). In multivariate analysis, mean global RNFL thickness (103.2±12.6 µm) increased significantly with younger age (standardized correlation coefficient beta:−0.30;P<0.001), larger neuroretinal rim area (beta:0.26;P<0.001), shorter axial length (beta:−0.21;P<0.001), thicker subfoveal choroidal thickness (beta:0.15;P<0.001), larger optic disc area (beta:0.10;P<0.001), less refractive lens power (beta:0.10;P<0.001), flatter anterior cornea (beta:0.07;P = 0.01) and female gender (beta:0.05;P = 0.03). In this population with an age of 50+ years, the age-related decline in RNFL thickness was 0.5 µm per year of life or 0.36% of an original RNFL thickness of 137 µm at baseline of the study at 50 years of age. Mean global RNFL thickness decreased by 2.4 µm for each mm enlargement of axial length.

Conclusions

The RNFL profile shows a double hump configuration with the thickest part in the inferior sector, followed by the superior sector, temporal sector and nasal sector. Factors influencing global RNFL thickness were younger age, larger neuroretinal rim, shorter axial length, thicker subfoveal choroid, larger optic disc, less refractive lens power, flatter anterior cornea and female gender. Beyond an age of 50+ years, RNFL decreased by about 0.3% per year of life at an age of 50+ years and by 2.4 µm per mm of axial elongation. These findings may be of interest for the knowledge of the normal anatomy of the eye and may be of help to diagnose diseases affecting the RNFL.  相似文献   

9.

Purpose

To examine a potential association between longitudinal changes in intraocular pressure (IOP), arterial blood pressure and body mass index (BMI) in a population-based setting.

Methods

The longitudinal population-based Beijing Eye Study included 2355 subjects with an age of 45+ years who were examined in 2006 and in 2011. The participants underwent a detailed ophthalmic examination including tonometry and measurement of arterial blood pressure and BMI.

Results

Data on IOP, arterial blood pressure and BMI measured in 2006 and in 2011 were available for 2257 (95.8%) subjects with a mean age of 59.5±9.7 years. The mean change in IOP was −1.25±2.26 mm Hg, mean change in mean blood pressure −7.4±12.1 mmHg, and mean change in BMI was 0.01±2.04 kg/m2. In multivariate analysis, the 5-year change in IOP was significantly associated with a higher change in mean blood pressure (P<0.001; standardized regression coefficient Beta:0.11; regression coefficient B:0.02; 95% confidence interval (CI):0.01,0.03) after adjusting for younger age (P<0.001;Beta:−0.18;B:−0.04;95% CI:−0.05,−0.03), shorter body stature (P = 0.002;Beta:−0.06;B:−0.06;95% CI:−0.03,−0.01), thicker central corneal thickness (P<0.001;Beta:0.19;B:0.02;95% CI:0.01,0.02), deeper anterior chamber depth (P = 0.01;Beta:0.05;B:0.33;95% CI:0.07,0.60), and lower intraocular pressure at baseline (P<0.001;Beta:−0.56;B:−0.42;95% CI:−0.45,−0.39). If the analysis included only longitudinal parameters, the change in IOP was significantly associated with a higher change in mean arterial blood pressure (P<0.001;Beta:0.10;B:0.02;95% CI:0.01,0.03) and a higher change in body mass index (P<0.04;Beta:0.04;B:0.04;95% CI:0.01,0.09).

Conclusions

In the 5-year follow-up of our population-based sample, a change in IOP was associated with a corresponding change in arterial blood pressure and with a corresponding change in body mass index. These longitudinal data support the notion of a physiological relationship between arterial blood pressure, intraocular pressure and body mass index. These findings may be of interest for the discussion of the pathogenesis of glaucomatous optic neuropathy.  相似文献   

10.

Purpose

To measure the distance between the optic disc center and the fovea (DFD) and to assess its associations.

Methods

The population-based cross-sectional Beijing Eye Study 2011 included 3468 individuals aged 50+ years. The DFD was measured on fundus photographs.

Results

Readable fundus photographs were available for 2836 (81.8%) individuals. Mean DFD was 4.76 ± 0.34mm (median: 4.74 mm; range: 3.76–6.53mm). In multivariate analysis, longer DFD was associated with longer axial length (P<0.001; standardized correlation coefficient beta: 0.62), higher prevalence of axially high myopia (P<0.001; beta:0.06), shallower anterior chamber depth (P<0.001; beta:-0.18), thinner lens thickness (P = 0.004; beta: -0.06), smaller optic disc-fovea angle (P = 0.02; beta: -0.04), larger parapapillary alpha zone (P = 0.008; beta: 0.05), larger parapapillary beta/gamma zone (P<0.001; beta: 0.11), larger optic disc area (P<0.001; beta: 0.08), lower degree of cortical cataract (P = 0.002; beta: -0.08), and lower prevalence of age-related macular degeneration (P = 0.001; beta: -0.06). Bruch´s membrane opening-fovea distance (DFD minus disc radius minus parapapillary beta/gamma zone width) in non-glaucomatous eyes was not significantly (P = 0.60) related with axial length in emmetropic or axially myopic eyes (axial length ≥23.5 mm), while it increased significantly (P<0.001; r: 0.32) with longer axial length in eyes with an axial length of <23.5mm. Ratio of mean DFD to disc diameter was 2.65 ± 0.30. If the ratio of disc-fovea distance to disc diameter was considered constant and if the individual disc diameter was calculated as the individual disc-fovea distance divided by the constant factor of 2.65, the resulting calculated disc diameter differed from the directly measured disc diameter by 0.16 ±0.13 mm (median: 0.13 mm, range: 0.00–0.89 mm) or 8.9 ± 7.3% (median: 7.4%; range: 0.00–70%) of the measured disc diameter.

Conclusions

DFD (mean: 4.76mm) increases with longer axial length, larger parapapillary alpha zone and parapapillary beta/gamma zone, and larger disc area. The axial elongation associated increase in DFD was due to an enlargement of parapapillary beta/gamma zone while the Bruch’s membrane opening-fovea distance did not enlarge with longer axial length. This finding may be of interest for the process of emmetropization and myopization. Due to its variability, the disc-fovea distance has only limited clinical value as a relative size unit for structures at the posterior pole.  相似文献   

11.

Purpose

To determine the optic disc-fovea angle (defined as angle between the horizontal and the line between the optic disc center and the fovea) and to assess its relationships with ocular and systemic parameters.

Methods

The population-based cross-sectional Beijing Eye Study 2011 included 3468 individuals. A detailed ophthalmic examination was carried out. Using fundus photographs, we measured the disc-fovea angle.

Results

Readable fundus photographs were available for 6043 eyes of 3052 (88.0%) individuals with a mean age of 63.6±9.3 years (range: 50–91 years) and a mean axial length of 23.2±1.0 mm (range: 18.96–28.87 mm). Mean disc-fovea angle was 7.76 ± 3.63° (median: 7.65°; range: -6.3° to 28.9°). The mean inter-eye difference was 4.01 ± 2.94° (median: 3.49°; range: 0.00–22.3°). In multivariate analysis, larger disc-fovea angle was associated (regression coefficient r2: 0.08) with older age (P = 0.009; standardized regression coefficient beta: 0.05), thinner RNFL in the nasal superior sector (P<0.001; beta: -0.17), superior sector (P<0.001; beta: -0.10) and temporal superior sector (P<0.001; beta: -0.11) and thicker RNFL in the inferior sector (P<001; beta: 0.13), nasal inferior sector (P<001; beta: 0.13) and nasal sector (P = 0.007; beta: 0.06), higher prevalence of retinal vein occlusion (P = 0.02; beta: 0.04), and with larger cylindrical refractive error (P = 0.04; beta: 0.04).

Conclusions

The optic disc-fovea angle markedly influences the regional distribution of the RNFL thickness pattern. The disc-fovea angle may routinely be taken into account in the morphological glaucoma diagnosis and in the assessment of structure-function relationship in optic nerve diseases. Future studies may address potential associations between a larger disc-fovea angle and retinal vein occlusions and between the disc-fovea angle and the neuroretinal rim shape.  相似文献   

12.

Objective

To assess the cumulative 10-year incidence of diabetic retinopathy (DR) and its associated factors in a population living in Greater Beijing.

Methods

The population-based longitudinal Beijing Eye Study, which included 4439 subjects (age in 2001: 40+years) in 2001, was repeated in 2011 with 2695 subjects participating (66.4% of the survivors). The study participants underwent a detailed ophthalmic examination. Fundus photographs were examined for the new development of DR.

Results

After excluding individuals with DR at baseline (n = 87) or no sufficient fundus photographs in 2011 (n = 6), the study included 2602 subjects with a mean age of 64.6±9.7 years (median: 64.0 years; range: 50 to 93 years). In the 10-year period, 109 subjects (39 men) developed new DR with an incidence of 4.2% (95% confidence interval (CI): 3.45,5.03). In multiple logistic regression analysis, incident DR was significantly associated with higher HbA1c value (P<0.001; Odds Ratio (OR): 1.73; 95% Confidence Interval (CI): 1.35,2.21), longer duration of diabetes mellitus (P<0.001; OR: 1.16; 95% CI: 1.10,1.22), higher serum concentration of creatinine (P = 0.02; OR: 1.01; 95% CI: 1.002,1.022), lower educational level (P = 0.049; OR: 0.74; 95% CI: 0.55,0.99), higher estimated cerebrospinal fluid pressure (P = 0.038; OR: 1.10; 95% CI: 1.01,1.22), and shorter axial length (P<0.001; OR: 0.48; 95% CI: 0.33,0.71).

Conclusions

The cumulative 10-year incidence (mean: 4.2%) of DR in a North Chinese population was significantly associated with a higher HbA1c value, longer known duration of diabetes mellitus, higher estimated CSFP and shorter axial length (P<0.001). Shorter axial length (or hyperopia) and, potentially, higher CSFP may be additional risk factors to be taken into account when counseling and treating patients with diabetes mellitus.  相似文献   

13.

Purpose

To assess prevalence, size and location of peripapillary intrachoroidal cavitations (PICCs) and their associations in a population-based sample. .

Methods

The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years (range:50-93 years). A detailed ophthalmic examination included enhanced depth imaging of the choroid by spectral-domain optical coherence tomography and fundus photography. PICCs were defined as triangular thickening of the choroid with the base at the optic disc border and a distance between Bruch´s membrane and sclera of ≥200μm. Parapapillary large choroidal vessels were excluded.

Results

Out of 94 subjects with high myopia (refractive error <-6.0 diopters or axial length >26.5mm in right eyes), OCT images were available for 89 (94.7%) participants. A PICC was detected in 15 out of these 89 highly myopic subjects (prevalence:16.9±4.0%) and in none of hyperopic, emmetropic or medium myopic subgroups each consisting of 100 randomly selected subjects. Mean PICC width was 4.2±2.3 hours (30°) of disc circumference and mean length was 1363±384μm. PICCs were located most frequently (40%) at the inferior disc border. On fundus photos, a typical yellow-orange lesion was found in 8 (53%) eyes with PICCs. In binary regression analysis, presence of PICCs was significantly associated with optic disc tilting (P=0.04) and presence of posterior staphylomata (P=0.046).

Conclusions

Prevalence of PICCs in the adult Chinese population was 16.9±4.0% in the highly myopic group, with no PICCs detected in non-highly myopic eyes. PICCs were located most frequently at the inferior optic disc border. Only half of the PICCs detected on OCT images showed a yellow-orange lesion on fundus photos. Presence of PICC was significantly associated only with an increased optic disc tilting and presence of posterior staphylomata, while it was not associated with axial length, refractive error or other ocular or systemic parameters.  相似文献   

14.
Intracranial hypertension is a severe therapeutic problem, as there is insufficient knowledge about the physiology of cerebrospinal fluid (CSF) pressure. In this paper a new CSF pressure regulation hypothesis is proposed. According to this hypothesis, the CSF pressure depends on the laws of fluid mechanics and on the anatomical characteristics inside the cranial and spinal space, and not, as is today generally believed, on CSF secretion, circulation and absorption. The volume and pressure changes in the newly developed CSF model, which by its anatomical dimensions and basic biophysical features imitates the craniospinal system in cats, are compared to those obtained on cats with and without the blockade of craniospinal communication in different body positions. During verticalization, a long-lasting occurrence of negative CSF pressure inside the cranium in animals with normal cranio-spinal communication was observed. CSF pressure gradients change depending on the body position, but those gradients do not enable unidirectional CSF circulation from the hypothetical site of secretion to the site of absorption in any of them. Thus, our results indicate the existence of new physiological/pathophysiological correlations between intracranial fluids, which opens up the possibility of new therapeutic approaches to intracranial hypertension.  相似文献   

15.
16.

Objective

To investigate the 5-year incidence and progression rate of primary open-angle glaucoma (POAG) in a health-center-based Korean population.

Methods

The study population comprised 5,021 subjects who participated in standardized health screening (including non-contact tonometry and fundus photography) at the Gangnam Healthcare Center during the period from January 2005 to December 2006 and again from January 2010 to December 2011. Among these subjects, 948 (18.9%) with findings suggestive of glaucoma were subjected to a comprehensive glaucoma evaluation, which included applanation tonometry and standard automated perimetry. Based on the results, the subjects were diagnosed as POAG suspect or definite POAG.

Results

The 5-year incidences of POAG suspect and definite POAG were 0.84% (42 subjects) and 0.72% (36 subjects), respectively. The rate of progression from POAG suspect to definite POAG was 4.75% per year. In subjects with a baseline intraocular pressure (IOP) >21 mmHg, the incidence of POAG suspect or definite POAG was significantly higher than in those with a baseline IOP≤21 mmHg (32% vs. 1.05%; P<0.001). A multivariate analysis showed that the progression from POAG suspect to definite POAG was significantly associated with older age (odds ratio [OR], 1.07; 95% confidence interval [CI], 1.03–1.10), higher baseline IOP (OR, 1.10; 95% CI, 1.01–1.24), higher body mass index (BMI) (OR, 1.15; 95% CI, 1.03–1.31), higher education level (OR, 1.57; 95% CI, 1.05–2.17), and higher hematocrit level (OR, 1.22; 95% CI, 1.08–1.43).

Conclusions

In the health-center-based Korean population, the 5-year incidence of POAG was 0.72%, and the rate of progression from POAG suspect to definite POAG was 4.75% per year. This study identified old age, high baseline IOP, high BMI, high level of education, and high hematocrit level as significant risk factors for incident POAG.  相似文献   

17.

Purpose

To assess the short-term day-to-day reproducibility of 24-hour intraocular pressure (IOP) curves in various respects in untreated primary open-angle glaucoma (POAG) and ocular hypertension (OHT) patients.

Methods

47 subjects with POAG and 34 subjects with OHT underwent IOP measurements every 2 hours in both eyes for consecutive 48 hours by a non-contact tonometer (NCT). IOP values at each time point were recorded. Mean IOP, peak IOP, time difference of peak IOP between two days and IOP fluctuation were also calculated. Intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate reproducibility.

Results

ICCs of the entire IOP values for a complete 24-hour curve were 0.577 and 0.561 in POAG and OHT patients, respectively. ICCs of IOP values at different time points ranged from 0.384 (10am) to 0.686 (4am) in POAG patients and from 0.347 (6am) to 0.760 (4am) in OHT patients. ICCs of mean IOP, peak IOP and IOP fluctuation were respectively 0.832, 0.704, 0.367 in POAG patients and 0.867, 0.816 0.633 in OHT patients. Only 37.23% and 35.29% of the peak IOP time points appeared within the time difference of 2 hours in POAG and OHT patients, respectively, while 53.19% and 48.53% appeared within 4 hours in POAG and OHT patients, respectively.

Conclusion

A 24-hour IOP curve in a single day is not highly reproducible in short-term and has limited use for evaluating individual IOP condition. Mean IOP and peak IOP for a 24-hour IOP curve are useful parameters in clinical follow-up, while IOP value at a certain time point, IOP fluctuation and peak IOP time point should be interpreted with caution.  相似文献   

18.
19.

Background

Glaucoma surgery is the most effective means for lowering intraocular pressure by providing a new route for fluid to exit the eye. This new pathway is through the sclera of the eye into sub-conjunctival tissue, where a fluid filled bleb typically forms under the conjunctiva. The long-term success of the procedure relies on the capacity of the sub-conjunctival tissue to absorb the excess fluid presented to it, without generating excessive scar tissue during tissue remodeling that will shut-down fluid flow. The role of inflammatory factors that promote scarring are well researched yet little is known regarding the impact of physical forces on the healing response.

Methodology

To help elucidate the interplay of physical factors controlling the distribution and absorption of aqueous humor in sub-conjunctival tissue, and tissue remodeling, we have developed a computational model of fluid production in the eye and removal via the trabecular/uveoscleral pathways and the surgical pathway. This surgical pathway is then linked to a porous media computational model of a fluid bleb positioned within the sub-conjunctival tissue. The computational analysis is centered on typical functioning bleb geometry found in a human eye following glaucoma surgery. A parametric study is conducted of changes in fluid absorption by the sub-conjunctival blood vessels, changes in hydraulic conductivity due to scarring, and changes in bleb size and shape, and eye outflow facility.

Conclusions

This study is motivated by the fact that some blebs are known to have ‘successful’ characteristics that are generally described by clinicians as being low, diffuse and large without the formation of a distinct sub-conjunctival encapsulation. The model predictions are shown to accord with clinical observations in a number of key ways, specifically the variation of intra-ocular pressure with bleb size and shape and the correspondence between sites of predicted maximum interstitial fluid pressure and key features observed in blebs, which gives validity to the model described here. This model should contribute to a more complete explanation of the physical processes behind successful bleb characteristics and provide a new basis for clinically grading blebs.  相似文献   

20.

Purpose

To evaluate the prevalence and associated factors of steep cornea/keratoconus in the adult Chinese population.

Methods

The population-based Beijing Eye Study 2011 included 3468 individuals with a mean age of 64.6±9.8 years (range: 50–93 years). A detailed ophthalmic examination was performed including optical low-coherence reflectometry. Steep cornea/keratoconus were defined as an anterior corneal refractive power exceeding 48 diopters.

Results

Mean refractive power of the cornea was 43.16±1.45 diopters (range: 36.51 to 48.46 diopters; flattest meridian) and 43.98±1.52 diopters (range: 37.00 to 52.88 diopters; steepest meridian). A steep cornea/keratoconus defined as corneal refractive power of ≥48 diopters and ≥49 diopters was detected in 27 subjects (prevalence rate: 0.9±0.2%) and 6 (0.2± 0.1%) subjects, respectively. Presence of steep cornea/keratoconus was associated with shorter axial length (P<0.001), smaller interpupillary distance (P = 0.038), lower best corrected visual acuity (P = 0.021), higher cylindrical refractive error (P<0.001) and more myopic refractive error (P<0.001). It was not significantly associated with gender, body height, psychic depression, cognitive function, blood concentrations of glucose, lipids, creatinine and C-reactive protein, blood pressure and quality of life score, nor with intraocular pressure, dry eye feeling, and lens thickness.

Conclusions

A steep cornea/keratoconus defined as corneal refractive power of 48+ diopters has a prevalence of 0.9±0.2% among Chinese aged 50 years and above. Its prevalence was significantly associated with the ocular parameters of shorter axial length, smaller interpupillary distance, higher cylindrical and myopic refractive error and lower best corrected visual acuity, however, with none of the systemic parameters tested.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号