1.
BackgroundThe leadless pacemaking transcatheter system, Micra, is a miniaturized, single-chamber pacemaker system. We report herein our experience with implantation of the Micra TPS system.ObjectiveThe current study was conducted to evaluate the safety and efficacy of the leadless Micra Transcatheter Pacemaker System (Medtronic).Research design and methodsThis was a prospective single centre nonrandomized study without controls. A transcatheter pacemaker was implanted in patients who had guideline based indications for ventricular pacing. 28 subjects were screened based on the selection criteria. Mica TPS was implanted. Parameters assessed were: duration of procedure (from femoral vein puncture to venous access closure), fluoroscopy time, number of device repositions, periprocedural electrical measurements (sensing, threshold and impedance) and in-hospital, intermediate to long term adverse events related to procedure.Result and conclusions: The device was successfully implanted in 28 subjects. The mean intraoperative sensing value was 9.04 ± 1.5 mV and the impedance was 766.89 ± 213.9 Ω. At discharge from hospital, those values were 13.2 ± 15.83 mV and 855 ± 111.7, respectively. The recommended pacing threshold value as achieved in all subjects was 0.78 V, i.e. ≤ 1 V at 0.24 ms. There was no adverse event or complications reported for any of the subjects. Mean time from hospitalization to discharge was 1.5 days. Implantation of leadless pacemakers is feasible, safe and provides advantages over the conventional system.  相似文献   

2.
目的:探讨经胸超声心动图引导下行房间隔缺损封堵术治疗先天性房间隔缺损(Atrial septal defect,ASD)的临床疗效。方法:比较先天性ASD患者行超声心动图组(49例)或介入组(53例),患者的疗效及心脏功能的变化。结果:超声心动图组并发症发生率显著低于介入组(P0.05);术后4周,两组患者的心率、舒张期室间隔厚度(Interventricular septal thickness,IVST)、左室后壁厚度(Left ventricular posterior wall thickness,LVPWT)、左心室心肌重量(Left ventricular mass,LVM)和左心室心肌重量指数(Left ventricular mass index,LVMI)明显降低(P0.05),左心室射血分数(Left ventricular ejection fraction,LVEF)和左心室高峰充盈率(Left ventricular peak filling rate,LVPFR)均显著升高(P0.05),其余指标则无明显变化(P0.05);但术后1周超声心动图组的LVEF、IVST和LVMI即显著高于术前(P0.05)。结论:胸超声心动图引导下行ASD封堵术与X线介入封堵术疗效相当,但前者可能对ASD患者的心脏功能的改善更为显著。  相似文献   

3.
In contrast with transthoracic echocardiography, transesophageal echocardiography provides a sure way to make the diagnosis of sinus venosus atrial septal defect; on the other hand this abnormality is more complex than that seen with the secundum atrial septal defect, and inexperienced operators may fail to recognize properly the defect. In front of a high reported sensitivity using transesophageal echocardiography, specificity is difficult to assess, due to possible underreporting of diagnostic errors. We describe a false positive diagnosis of sinus venosus atrial septal defect, in the setting of enlarged right chambers of the heart because of pressure overload. Modified anatomy of the heart, together with the presence of a prominent linear structure(probably Eustachian Valve) and an incomplete examination in this case made image interpretation very prone to misinterpretation. In this anatomical setting transesophageal longitudinal "bicaval" view may be sub-optimal for examining the atrial septum, potentially showing false images that need to be known for correct image interpretation. Nonetheless, a scan plane taken more accurately at the superior level would have demonstrated/excluded the pathognomonic feature of sinus venosus atrial septal defect in the high atrial septum, between the fatty limbus and the inferior aspect of the right pulmonary artery; moreover TEE allows morphological information about the posterior structures of the heart that need to be investigated in detail for a complete diagnosis.  相似文献   

4.
ObjectivesComparison of outcomes, device deployment time (DT), and total time (TT) using a single tapered Coons dilator versus sequential serial dilation for implantation of the Micra leadless pacemaker.BackgroundMicra leadless pacemaker placement requires a 23 French Micra introducer sheath (MIS) for percutaneous delivery. We sought to evaluate outcomes with use of a single tapered Coons dilator (CD) versus sequential serial dilatation (SD) method to facilitate insertion of the Micra introducer sheath.Methods35 patients were included in the SD arm and 49 in the CD arm. DT and TT were recorded in minutes and cost in dollars. Analysis was performed using independent t-test between two groups and one-way ANOVA to evaluate inter-operator variability in the CD arm.ResultsBoth DT and TT were significantly lower for the CD arm (15.1 ± 5.1 vs 23.5 ± 9.3, p < 0.0005 and 29.9 ± 14 vs 39.3 ± 13.5 min, p = 0.000374; respectively). The cost was also significantly lower using a CD versus SD. There was no inter-operator variability in the CD arm between 6 operators (p = 0.177 for DT and p = 0.304 for TT). No complications occurred in the SD arm. There were 3 vascular access site complications in the CD arm, all of which occurred early in the operator’s experience.ConclusionCoons dilator is an efficient and cost-effective method for vascular dilatation to facilitate Micra leadless pacemaker insertion. Rate of complications is low and expected to improve with greater experience.  相似文献   

5.
A 92-year-old woman underwent an implantation of a leadless pacemaker (Micra; Medtronic, Inc, Minneapolis, MN) for complete atrioventricular block after a transvenous lead extraction due to a pocket infection of a dual chamber pacemaker. Marked scoliosis and a humpback due to an advanced age made it impossible to direct the tip of the pacemaker delivery catheter towards the right ventricular septum or apex and shape the catheter into a gooseneck-shape. Thus, by attaining a halo-catheter shape of the delivery catheter, the catheter tip could be directed toward the infero-basal portion of the right ventricular septum. The pacemaker was successfully deployed at that site without any complications, and good device parameters were achieved. The halo-shape technique may be also an alternative method for delivering a leadless pacemaker in patients with an unsuccessful delivery of a leadless pacemaker to the right ventricular septum using the conventional gooseneck-shape technique.  相似文献   

6.
目的:探讨起搏器术后新发房性心律失常的发生情况及其相关影响因素。方法:选择2006年1月至2007年12月于沈阳军区总医院首次植入永久起搏器的107例患者,男性50例,平均年龄65.0±11.9岁,术前通过追问病史及相关检查均排除房性心律失常(房颤、房扑、房速),术后平均随访3.9年,观察新发房性心律失常情况。按术后是否出现房性心律失常,将患者分为新发房性心律失常组和无房性心律失常组,比较两组患者术前和术后心脏超声结果的变化、心室起搏比例、起搏部位及起搏模式,并通过logistic回归分析起搏器术后发生房性心律失常的影响因素。结果:新发房性心律失常组26例(24.3%),其中房颤17例(15.9%),房扑2例(1.9%),房速7例(6.5%);无房性心律失常组81例。与无房性心律失常组比较,新发房性心律失常组左房内径明显增加(P=0.040)、二尖瓣返流程度较重(P=0.032)及左室射血分数明显下降(P=0.001),心室起搏百分比(VP%)显著升高(P=0.017)。心尖部起搏患者房性心律失常的发生率明显高于间隔部起搏(33.3%vs 16.9%,P<0.05),双腔起搏组患者房性心律失常发生率明显低于单腔起搏器组(18.7%vs 37.5%,P<0.05)。Logistic回归分析显示术后新发房性心律失常的发生与高比例的心室起搏(P=0.006)、VVI(R)起搏模式(P=0.014)及右心室起搏电极导线植于心尖部(P=0.024)显著相关。结论:起搏模式、心室起搏百分比、起搏部位是起搏器术后发生房性心律失常的影响因素。  相似文献   

7.
摘要 目的:探究永久起搏器程控在心房颤动诊断中的临床应用及意义。方法:选择78例我院收治的心房颤动患者随机分为程控组和非程控组2组,其中观察组患者给与永久起搏器程控诊断,非程控组则仅给植入永久起搏器,但非程控。对比分析两组患者基本资料、房颤负荷、心房与心室起搏比、心房结构重构及左心功能、P波结果;比较永久起搏器程控诊断与临床诊断结果的差异,分析永久起搏器程控在心房颤动诊断敏感度。结果:程控组和非程控组患者的男女比例、年龄、心率失常的类型、存在的基础性疾病以及使用过的治疗药物比较,差异均无统计学意义(P>0.05);程控组和非程控组患者的房颤负荷、VP值和P波最小时限均显著小于非程控组,AP值、P波最大时限和P波离散度则显著大于非程控组(P<0.05);程控组和非程控组患者的LAD、RAD、LVEDD和LVEF值在植入前和植入后均不存在显著性差异(P>0.05)。与临床诊断结果比较可以发现,永久起搏器程控对心房颤动检出率为97.44 %,且永久起搏器程控应用于诊断心房颤动敏感度高达98.72 %。结论:对心房颤动患者采用永久起搏器程控进行诊断,可以在心电图检查的各项指标结果上对患者的心房颤动给与准确的判断,具有较高的临床应用价值,值得临床推广使用。  相似文献   

8.
BackgroundWe demonstrate a case series of 8 pediatric patients, all under 30 kg, who had leadless pacemaker implants via the internal jugular vein.MethodsA retrospective review of pediatric leadless pacing placement via the internal jugular vein at the University of Minnesota Masonic Children's Hospital and UC Davis Medical Center from 2018 through 2021 was performed. Rationales for pacing, demographics of patients, pacing thresholds, and longevity of devices were recorded.ResultsEight internal jugular pacemaker insertions were performed successfully in patients weighing between 10.9 kg and 29 kg. Five patients had Micra implantation via the right internal jugular vein, whereas 3 patients had insertion via the left internal jugular vein. No surgical cut-downs were performed. No venous complications occurred. Up to 3 years of follow-up were noted.ConclusionLeadless pacemaker implantation, via left or right internal jugular veins, is feasible without surgical cutdown in patients <30 kg  相似文献   

9.

Background

Cor triatriatum is a very rare congenital abnormality, usually symptomatic during childhood, diagnosis in adult age is less common.

Case Presentation

We report the case of a 40 years old woman referred to our hospital for atrial flutter ablation, transthoracic cardiac bidimensional echocardiography showed an abnormal membrane bisecting the left atrium, the diagnosis of cor triatriatum was fully made via three dimensional transesophageal echocardiography. More interstingly three other cardiac anomalies were associated: ostium secundum atrial septal defect, dilated coronary sinus due probably to persistent left superior vena cava and normally functioning bicuspid aortic valve.

Conclusions

Cor triatriatum sinister in adult life is important to recognize because it may be easily surgically correctable when hemodynamically significant. Three Dimensional transesophageal echocardiography is a minimally invasive and highly sensitive diagnostic modality.  相似文献   

10.

Introduction

The risk of developing conduction disturbances after coronary bypass grafting (CABG) or valvular surgery has been well established in previous studies, leading to permanent pacemaker implantation in about 2% to 3% of patients, and in 10% of patients undergoing repeat cardiac surgery. We sought to determine the incidence, features and predictors of conduction disorders in the immediate post-operative period of patients subjected to open-heart surgery, and the need for permanent pacemaker implantation.

Material and Method

We prospectively studied 374 consecutive patients who underwent open-heart surgery in our institution: coronary artery bypass (CABG) (n=128), Mitral valve replacement(MVR)(n=18), aortic valve replacement(AVR) (n=21), MVR and AVR(n=56), repair of ventricular septal defect (VSD) (n=51), repair of tetralogy of Fallot (TOF) (n=57),CABG and valvular surgery (n=6), others (n=37).

Results

Among 374 patients included in our study (mean age 34.46±25.68; 146 males), 192 developed new conduction disorders: symptomatic sinus bradycardia in 8%, atrial fibrillation with slow ventricular response (AF) in 4.5%, first-degree atrioventricular block (AVB)in 6.4%, second-degree AVB in 0.3%, third-degree AVB in 7%, new right bundle branch block (RBBB) in 33%, and new left bundle branch block (LBBB) in 2.1%. In 5.6% patients, a permanent pacemaker was implanted, 47.6% of them underwent valvular surgery. In 44.1% of patients the conduction defects occurred in the first 48 hr. after surgery. In CABG group, 29.7% of patients developed new conduction disturbances; the most common of them was symptomatic sinus bradycardia. After valvular surgery 44.2% of patients developed conduction disturbances, of those the most common was atrial fibrillation with slow ventricular response . After VSD and TOF repair, the most common conduction disturbance was new RBBB. Perioperative myocardial infarction (MI) occurred in 1.9% of patients. The occurrence conduction disturbance was compared with patient age, sex, occurrence of perioperative MI, ejection fraction (EF), postoperative use of ß-adernergic receptor blocking agents and digitalis and type of cardiac surgery. By regression analysis there was a correlation between type of surgery and new conduction defects, being significant for CABG and TOF repair. Only the occurrence of perioperative MI was related to PPM implantation.

Conclusion

Irreversible AVB requiring a PPM is an uncommon complication after open-heart surgery. Peri-operative MI is a risk factor.  相似文献   

11.
Transvenous pacing in patients with postoperative complex congenital heart disease (CHD) can be challenging and pose technical challenges to lead placement because of the complex anatomy, distortions produced by the surgical procedures, and the altered relationship of cardiac chambers. We describe the utility of angiography for transvenous dual chamber pacemaker implantation in a post-operative complex congenital heart disease.  相似文献   

12.
Although previous studies showed that transthoracic echocardiography (TTE) can be used to guide transcatheter closure of atrial septal defect (ASD), whether TTE can be used to guide transcatheter closure of secundum ASD with a deficient superior-anterior rim is unknown and this critical issue was addressed in the present study. A total of 280 patients with secundum ASD who underwent transcatheter ASD closure were recruited and divided into groups A and B depending on ASD superior-anterior rim>4 mm (n = 118) or ≤4 mm (n = 162). TTE was used to guide Amplatzer-type septal occluder (ASO) positioning and assess residual shunt. Procedure success was defined as no, trivial and small residual shunt immediately after the procedure as assessed by color Doppler flow imaging. Group A and group B did not differ in complication rate (8.55% vs.7.55%), procedure success rate (98.3% vs. 95.0%) or complete closure rate immediately after the procedure (89.7% vs. 89.3%) or at 6-month follow-up (98.3% vs. 96.8%). The mean procedure and fluoroscopy time in group B were much longer than those in group A. In conclusion, the absence of a sufficient superior-anterior rim in patients undergoing percutaneous closure of secundum-type ASDs using fluoroscopic and TTE guidance is associated with slightly greater device malposition and migration as well as increased procedural and fluoroscopic times, but the overall complication rate did not differ with TTE guidance when compared to historical controls that used TEE guidance.  相似文献   

13.
We present a case of 36-year-old woman with twin pregnancy, Chagas cardiomyopathy and history of multiple episodes of dizziness and syncope. The patient's Holter study revealed sinus pauses of up to 5.3 seconds, frequent premature ventricular contractions (PVC) and some episodes of non-sustained ventricular tachycardia at 110 bpm. To avoid teratogenic radiation, dual chamber pacemaker implantation was performed guided by transthoracic echocardiography. The patient was treated with metoprolol succinate 100 mg once a day to reduce PVC and nonsustained ventricular tachycardia. During follow up, the patient reported complete resolution of syncope and dizziness. She went on to have a normal delivery without complications. PCRs for Chagas in both twins were negative.  相似文献   

14.
The diagnosis of uncomplicated ventricular septal defect and uncomplicated patent ductus arteriosus presents few hazards. Differential diagnosis of atrial septal defect and of transposed pulmonary veins is technically more difficult. The complex nature of most types of cyanotic congenital heart disease requires the combined use of catheterization, determination of circulation times, ventilation studies, and possibly angiocardiography.Reports of eight cases in which cardiac catheterization was carried out illustrate the common forms of acyanotic and cyanotic heart disease and the factors in diagnosis.  相似文献   

15.
目的:探讨植入心脏起搏器的老年阵发性房颤患者再发房颤(包括无症状性房颤)发生率及左房容积指数对再发房颤的影响。方法:收集2012年1月-2013年12月在我院起搏器门诊长期随访且未服用抗心律失常药物的起搏器术后老年阵发性房颤患者148例,记录基线特征、超声心动图参数及随访期间内房颤发生情况。分别根据左房容积指数及房颤负荷进行分组,应用Cox回归分析探讨起搏器检测的再发房颤及房颤高负荷的危险因素。结果:患者平均随访时间为22.79个月,期间57.43%的患者再发房颤,22.97%的患者为房颤高负荷,15.54%的患者为无症状房颤。多因素Cox回归分析发现左房增大分别是再发房颤及房颤高负荷的独立危险因素。结论:左房容积指数是预测起搏器术后老年阵发性房颤患者房颤复发及房颤高负荷的独立危险因素。  相似文献   

16.
目的:探讨非侵入起搏器负荷超声心动图对永久起搏器植入术后合并冠脉病变的临床诊断意义。方法:采用前瞻性研究,实验对象为24名因房室传导阻滞或慢性心房纤颤而植入永久起搏器的患者(男12人,女12人,平均年龄70.2±6.1岁),所有患者均因不典型心绞痛入院和完全起搏依赖,心电图改变无法判断是否存在心肌缺血。通过体外程控进行非侵入性起搏器负荷超声心动图检测室壁运动幅度如左室射血分数评估心功能,检测后行冠脉造影术评估冠脉狭窄情况,及实验前后测定B型脑钠肽的变化。结果:24例患者中,有13例通过起搏器负荷超声心动图应激实验测得LVEF随起搏心率增加而降低,这其中又有11例患者通过冠状动脉造影证实其冠脉存在不同程度的狭窄,诊断的准确性84.62%;11例冠脉造影结果阳性的患者实验后30分钟测得的BNP水平较实验前明显升高。结论:非侵入性起搏器负荷超声心动图应激实验作为一种简单、快速、安全及具有诊断意义的方法,可用来评价植入起搏器术后完全起搏依赖,心电图继发性ST-T改变难以判断的心肌缺血,为进一步检查及治疗提供可靠临床数据。  相似文献   

17.
The diagnosis of uncomplicated ventricular septal defect and uncomplicated patent ductus arteriosus presents few hazards. Differential diagnosis of atrial septal defect and of transposed pulmonary veins is technically more difficult. The complex nature of most types of cyanotic congenital heart disease requires the combined use of catheterization, determination of circulation times, ventilation studies, and possibly angiocardiography. Reports of eight cases in which cardiac catheterization was carried out illustrate the common forms of acyanotic and cyanotic heart disease and the factors in diagnosis.  相似文献   

18.
We report a case of a 52-year-old patient with dilated cardiomyopathy who presented with worsening heart failure. Two-dimensional transthoracic echocardiography and real-time three dimensional transthoracic echocardiography showed severe dilated cardiac chambers, impaired ejection fraction and a mobile right atrial thrombus 2.6 × 1.0 cm in size, traversing the right atrial cavity during the whole cardiac cycle. After one week therapeutic anticoagulation, echocardiography confirmed no evidence of residual thrombus.  相似文献   

19.
Upper venous system anatomic variations may cause difficulties during cardiac pacemaker implantation. Persistent left superior vena cava (PLSVC) and absent right superior vena cava could be an arrhythmogenic source of atrial arrhythmias and cardiac conduction disease. We represent dual-chamber pacemaker implantation in a patient with a very rare upper venous system anomaly, paroxysmal atrial fibrillation, sick sinus syndrome, that cause unusual fluoroscopic image.  相似文献   

20.

Background

Good and reliable atrial sensing is a fundamental part of atrioventricular (AV) synchrony in dual chamber pacemakers. Due to the floating nature of atrial sensing electrode in single pass dual chamber pacemakers (VDD) compared with two-lead dual chamber pacemakers (DDD), they are more prone to atrial under-sensing and the resulting loss of AV synchrony. We hypothesized that there is a relation between the chronicity of AV block and the amplitude of intracardiac atrial signal amplitudes (IASA).

Methods

Detailed demographic, electrocardiographic and echocardiographic data were recorded in 34 consecutive patients with congenital and acquired complete heart block (CHB). The intracardiac atrial signal amplitudes (IASA) were recorded at implantation time, 48 hours and 2 months post-implantation and compared between the two groups of patients.

Results

The mean age of the study group was 38.73±12.53 years (congenital: 30.08±11.07, acquired: 47.38±6.5). There were no important differences in left atrial or ventricular sizes and in P-wave amplitude in lead II, but the IASA was significantly higher in the congenital group at implantation time (5.21±1.86 vs. 3.38±0.84 mV, P<0.001) and during the follow-up.

Conclusion

The intracardiac atrial signal amplitudes were higher in congenital CHB compared with the acquired CHB. Chronicity (and may be the congenital type) of CHB may be an affecting factor in case selection for VDD pacemaker implantation.  相似文献   