首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Q H Qazi  J G Hill 《Steroids》1973,22(3):311-325
A method is described for simultaneous determination of seven common urinary 17-ketosteroids, pregnanediol (5β-pregnane- 3α, 20α-diol) and pregnanetriol (5β-pregnane-3α,17α,20α-triol) by gas-liquid chromatography. The essential steps include hydrolysis of conjugates by an extract from Helixpomatia, use of 5β-cholestan-3α-ol as an internal standard, silylation and gas chromatography using 3% XE-60 as a stationary phase. The chromatograms were clear and the peaks easily identifiable. Laborious purification procedures were not necessary. 5β-pregnane-3α,20α-diol and 5β-pregnane-3α, 17α,20α-triol were measured in 22 adult males and 17 adult females. The subjects were trained hospital personnel, healthy and without medications. The results, in general, were in agreement with those reported by others.  相似文献   

2.
1. A new highly sensitive and accurate ultramicro method for the estimation of testosterone in human peripheral plasma is described. The method uses paper-and thin-layer-chromatographic separation of plasma testosterone, which is determined as testosterone diheptafluorobutyrate by electron-capture detection after gas-liquid chromatography. 2. The average difference between duplicates is +/-2% (range 1-5%) with as little as 2.5ml. of human male peripheral plasma. With 10ml. of plasma the method is sensitive enough for the accurate determination of testosterone in human female plasma. The high order of accuracy is achieved by the use of a radioactive label and an internal standard for gas chromatography, and by obtaining several gas chromatograms from the same plasma sample. 3. As little as 40mumug. of peripheral plasma testosterone can be detected. The method is 20 times as sensitive as electron-capture techniques with the monochloroacetate derivative. 4. The method is simpler and quicker than double-isotope-derivative methods, and slightly more sensitive. The advantages of the method, which is specific for testosterone, are its high sensitivity and accuracy, which are achieved with relative convenience.  相似文献   

3.
A gas-liquid chromatographic method employing on-column alkylation and a nitrogen-sensitive detector was developed for the analysis of 5-fluoro-2'-deoxyuridine, 5-fluorouridine, and 5-fluorouracil in plasma and urine. Samples (0.72 ml) containing the fluoropyrimidine and internal standard (5-chloro-2'-deoxyuridine for nucleoside analyses and 6-methyluracil for 5-fluorouracil analyses) were prepared for gas-liquid chromatography by sequential cation-exchange and anion-exchange column chromatography. Recoveries of fluoropyrimidines were 71-95% over the concentration ranges studied. The dried eluate from the anion-exchange column was dissolved in p-tolyltrimethylammonium hydroxide in methanol before gas-liquid chromatographic analysis. Columns packed with either 3% SP-2100 on Supelcoport or 3% OV-1 on Gas-Chrom Q were suitable for nucleoside analyses; a column packed with 0.75% Carbowax 20M-5% KOH on Chromsorb G was used for 5-fluorouracil analyses. The fluoropyrimidine nucleosides were well separated from each other and from the potentially interfering endogenous compounds 2'-deoxyuridine and uridine; 5-fluorouracil was well separated from uracil. Linear standard curves (peak area ratio method) were obtained for plasma containing 0.025 to 20 micrograms FdUrd (0.1 to 81 microM) or 0.05 to 1.0 microgram FUrd (0.2 to 3.8 microM), and for urine containing 0.2 to 1.0 microgram (0.8 to about 4 microM) of the nucleosides. Standard curves for 5-fluorouracil (1.5 to 7.9 microM) and 2'-deoxyuridine (0.9 to 4.4 microM) were also linear. A measurable amount of 5-fluorouracil, equivalent to 4 to 7% of the 5-fluoro-2'-deoxyuridine injected, was formed from the nucleoside on the gas-liquid chromatographic column, requiring correction of 5-fluorouracil concentrations measured in the presence of 5-fluoro-2'-deoxyuridine.  相似文献   

4.
Prostaglandin and thromboxane production by rat decidual microsomes   总被引:4,自引:0,他引:4  
The preparation of a microsomal fraction from the decidual tissue of pregnant rat uteri is described. Incubation of such microsomes with a mixture of radiolabelled and cold arachidonic acid (51 micrometer) plus cofactors resulted in a 30% substrate conversion. Products were resolved into four peaks (A, B, C and D) by thin-layer chromatography. Combined gas-liquid chromatography-mass spectrometry and further thin-layer chromatography identified the products as PGF2 alpha (A); thromboxane B2 (B); a mixture of 6-OXO PGF1 alpha and PGE2 (C); PGD2 and PGE2 (D). PGE2 was the major product.  相似文献   

5.
Chlorophenols are readily converted to methyl ethers by the reaction with diazomethane. Mixtures of methyl ethers of mono-, di-, tri-, tetra- and pentachlorophenols can be separated completely by gas-liquid chromatography on silicone high vacuum grease and sodium alkyl-benzene sulfonate columns at 150~190°C. The peaks of chlorophenol methyl ethers are sharper than that of free chlorophenols. Pentachlorophenol and tetrachlorophenol in technical products and commercial herbicide formulations can be determined by internal standard method with dibutyl phthalate.  相似文献   

6.
Vitamin D2 is less toxic in rats when compared to vitamin D3. Our laboratory has been involved in research projects which were directed towards identifying the possible mechanisms responsible for the toxicity differences between vitamins D2 and D3 in rats. The present research project was designed to isolate and identify new metabolites of vitamin D2 from serum of rats which were fed toxic doses of vitamin D2. Hypervitaminosis D2 was induced in 30 rats by feeding each rat with 1000 nmol of vitamin D2/day x 14 days. The rats were sacrificed on the 15th day and obtained 180 ml of serum. The lipid extract of the serum was directly analyzed by a straight phase HPLC system. The various vitamin D2 metabolites were monitored by their ultraviolet (UV) absorbance at 254 nm. One of the UV absorbing peaks did not comigrate with any of the known vitamin D2 metabolites. This unknown metabolite peak was further purified by HPLC and was then subjected to UV absorption spectrophotometry and mass spectrometry. The structure assignment of the new metabolite was established to be 4,25-dihydroxyvitamin D2 [4,25(OH)2D2] by the techniques of UV absorption spectrophotometry and mass spectrometry and by the new metabolite's susceptibility to sodium metaperiodate oxidation. At present the biological activity of this unique 'A-ring' hydroxylated vitamin D2 metabolite is not known. As this new metabolite is isolated from the serum of rats intoxicated with vitamin D2, we speculate that 4,25(OH)2D2 may be playing an important role in the deactivation of vitamin D2.  相似文献   

7.
A specific and sensitive method is described for the detection of clofibrate in biological fluids. The drug is separated from associated fatty acids by thin-layer chromatography and the methyl ester is quantified by gas-liquid chromatography. Recovery is excellent, and any small losses are corrected with an internal recovery standard. Although more time-consuming than other available techniques, the method offers advantages for accurate studies of clofibrate metabolism.  相似文献   

8.
The total serum concentration of 25-hydroxyvitamins D (25-hydroxyvitamin D3 and 25-hydroxyvitamin D2) is currently used as an indicator of vitamins D status. Vitamins D insufficiency is claimed to be associated with multiple diseases, thus accurate and precise reference methods for the quantification of 25-hydroxyvitamins D are needed. Here we present a novel enzyme-assisted derivatisation method for the analysis of vitamins D metabolites in adult serum utilising 25-[26,26,26,27,27,27-2H6]hydroxyvitamin D3 as the internal standard. Extraction of 25-hydroxyvitamins D from serum is performed with acetonitrile, which is shown to be more efficient than ethanol. Cholesterol oxidase is used to oxidize the 3β-hydroxy group in the vitamins D metabolites followed by derivatisation of the newly formed 3-oxo group with Girard P reagent. 17β-Hydroxysteroid dehydrogenase type 10 is shown to oxidize selectively the 3α-hydroxy group in the 3α-hydroxy epimer of 25-hydroxyvitamin D3. Quantification is achieved by isotope-dilution liquid chromatography–tandem mass spectrometry. Recovery experiments for 25-hydroxyvitamin D3 performed on adult human serum give recovery of 102–106%. Furthermore in addition to 25-hydroxyvitamin D3, 24,25-dihydroxyvitamin D3 and other uncharacterised dihydroxy metabolites, were detected in adult human serum.  相似文献   

9.
A convenient, accurate assay was developed for determining skin cholesta-5,7-dien-3 beta-ol (7,8-didehydrocholesterol) concentrations. Ultraviolet spectrophotometry provided quantitation of the sterol from rat skins following saponification and chromatography on Lipidex and high-performance liquid chromatography. Correction for recoveries was accomplished by using 7,8-didehydro[3 alpha-3H]cholesterol as an internal standard. Chronic dosing of vitamin D-deficient rats with 1,25-dihydroxyvitamin D3 caused a 4-fold increase in skin 7-dehydrocholesterol content. This rise was not the result of changes in food consumption, body weight, or plasma calcium. Cholesterol concentrations were not significantly elevated although some of the other nonsaponifiable lipid components found in the high-performance liquid chromatogram appeared to be increased by the treatment. These results suggest that the vitamin D hormone 1,25-(OH)2D3 may exert a positive feedback regulation on the production of vitamin D3 in skin.  相似文献   

10.
The results for the quantitative analysis and identification of steroidal sapo-genins of 16 species of Dioscorea rhizomes are given in Table 1. The amount of steroidal sapogenin varies from 0.073%–5.93%, its highest content of diosgenin is 5.93% in D. zingiberensis C. H. Wright. 2. The results observed from paper chromatography, thin layer chromatography and gas-liquid chromatography revealed that except the sapogenin of D. chingii Pr. and Br. is similar to tokorogenin, all other sapogenins after recrystallization yield a spot identical to diosgenin or yamogenin. Meanwhile, in most Dioscorea sample, a spot identical to △ 3, 5-diene-25D-spirostane was shown by using thin layer chromatography and gas-liquid chromatography. (Table 2). 3. The results observed from infrared spectrum and gas-liquid chromatography revealed that the sapogenins of D. collettii, Hook. f; D. collettii. Hook, f. var. hypoglauca, Pei and Ting. and D. tokoro Makino. contained 25L-spirostane. (A900≤ A920 cm-1).  相似文献   

11.
A new fully automated high-performance liquid chromatography (HPLC) method using 1 ml of serum has been developed for the determination of retinol (Vitamin A), alpha-tocopherol (Vitamin E), 25-hydroxyvitamin D(3) and 24 R,25-hydroxyvitamin D(3). The eluate was monitored with a photodiode-array detector at three wavelengths-namely: 265 nm for Vitamin D(3), 291 nm for Vitamin E and 325 nm for Vitamin A. The detection limits were equal to or lower than 1 ng ml(-1) for all vitamins. The linearity obtained with serum samples (standard addition method) gives correlation coefficients (r(2)) ranging between 0.999 and 0.996 in all cases, with standard deviation of the slope between 3.2 and 1.6%. The repeatability was between 4.0 and 6.0% and the within-laboratory reproducibility was lower than 10% in all cases. The most outstanding features of the present method are its ease of use, its rapidity and fully automation, which enables its use for routine analysis. The time required per sample was 30 min, because the overlapped development of the steps. This method was used for the determination of normality range of these vitamins in healthy people in the 18-80-year-old interval.  相似文献   

12.
A gas-liquid chromatographic (glc) assay for abscisic acid (ABA) is described that is both rapid and highly sensitive. The selectivity and sensitivity of an electroncapture detector are used to reduce the assay procedure to just four steps: extraction, thin-layer chromatography (tle), esterification, and gle. Quantification of the ABA present is by reference to ethyl abscisate added during the assay as an internal standard. The procedure enables samples containing as little as 100 pg of ABA to be assayed.  相似文献   

13.
In general, mass spectrometric quantification of small molecules in routine laboratory testing utilizes liquid chromatography coupled to low mass resolution triple-quadrupole mass spectrometers (QQQs). Here we introduce high-resolution tandem mass spectrometry (quadrupole-Orbitrap) for the quantification of 25-hydroxy-vitamin D [25(OH)D], a marker of the vitamin D status, because the specificity of 25(OH)D immunoassays is still questionable and mass spectrometric quantification is becoming increasingly important. Liquid chromatography coupled to high-resolution tandem mass spectrometry (LC-MS/HR-MS) was used to quantify 25-hydroxy-cholecalciferol [25(OH)D3], 25-hydroxy-ergocalciferol [25(OH)D2], and their C3-epimers 3-epi-25(OH)D3 and 3-epi-25(OH)D2. The method has a run time of 5 min and was validated according to the US Food and Drug Administration and the European Medicines Agency guidelines. High mass resolution was advantageously applied to separate a quasi-isobaric interference of the internal standard D6-25(OH)D2 with 3-epi-25(OH)D3. All analytes showed an imprecision of below 10% coefficient of variation (CV), trueness between 90% and 110%, and limits of quantification below 10 nM. Concentrations measured by LC-MS/HR-MS are in good agreement with those of the National Institute of Standards and Technology reference methods using LC-MS/MS (QQQ). In conclusion, quantification of 25(OH)D by LC-MS/HR-MS is applicable for routine testing and also holds promise for highly specific quantification of other small molecules.  相似文献   

14.
An isocratic high-performance liquid chromatography method for the simultaneous determination of various fat-soluble vitamins and carotenoids is reported. The method utilizes a Radial-Pak C-18, 5-microns column and an elution solvent composed of methanol:acetonitrile:chloroform (25:60:15). Only 100 microliters of plasma sample is required for one determination. Retinol, alpha-tocopherol, alpha-carotene, beta-carotene, lycopene, zeaxanthin, and two other unidentified carotenoids can be clearly separated and quantified in one HPLC run using alpha-tocopheryl acetate or tocol as the internal standard. The eluted peaks are quantified by either a photodiode-array detector at preprogrammed wavelengths at the absorption maxima of the compounds or a dual-wavelength detector at 280 and 436 nm. The total run time is 16 min. With an automatic injector and a programmable detector, the system allows unattended operation. The within-run and day-to-day coefficients of variation range from 1 to 8%. The lower limits of determination are 2, 40, and 2 ng for retinol, alpha-tocopherol, and carotenes, respectively. In addition, the system monitors the absorption spectra of the eluant during the HPLC run; this allows the spectral identification of various compounds separated in the same run.  相似文献   

15.
rac-1-[1-14C]Lauroyl-2-oleylglycero-3-phospho[methyl-3H]choline and rac-1-lauroyl-2-[1-14C]oleoylglycero-3-phospho[methyl-3H]choline along with rac-1-palmitoyl-2-oleylglycero-3-phosphocholine and sn-1-palmitoyl-2-oleylglycero-3-phosphocholine were synthesized and subjected to hydrolysis with phospholipase C (EC 3.1.4.3) from Clostridium perfringens and phospholipase D (EC 3.1.4.4) from cabbage. Kinetics of hydrolysis of the radioactive substrates were determined by measuring the 3H radioactivity retained in the aqueous phase due to free choline and phosphocholine and the 3H and 14C radioactivity recovered in the organic phase due to the released diacylglycerols and phosphatidic acids and the residual phosphatidylcholines. The rate of hydrolysis of the unlabelled substrates by phospholipase C was determined by thin-layer chromatography and gas-liquid chromatography of the methanolysis products. The relative initial rates of hydrolysis of sn-1,2,- and sn-2,3-enantiomers were 100-200:1 for phospholipase C and 40-50:1 for phospholipase D using rac-1-lauroyl-2-oleoylglycero-3-phosphocholine as the substrate. The substitution of the 2-acyl group by an alkyl group resulted in a loss of stereospecificity, which was partial for phospholipase C (relative rates equal to 8-13:1) and total for phospholipase D. There was a parallel dramatic decrease (500-1000-fold) in the initial rate of hydrolysis with phospholipase C but the activity of phospholipase D was only moderately reduced (18-fold). These findings are consistent with the earlier observed loss of the stereospecificity of lipoprotein lipase following introduction of a 2-alkyl group into triacylycerols, and point to a general unsuitability of 2-alkyl-linked acylglycerols as substrates for the assay of the stereospecificity of lipases, as well as for the isolation of enantiomeric 2-alkylacylglycerols by means of stereospecific lipases.  相似文献   

16.
A lipopolysaccharide was isolated from Pseudomonas aurantiaca IMB 31 by extraction with aqueous phenol and purified by ultracentrifugation. The lipopolysaccharide was confined to the phenol phase. Fucosamine (2-amino-2,6-dideoxygalactose) (36%) and bacillosamine (2,4-diamino-3,4,6-trideoxyglucose) (23%) were identified as hypothetic components of the O-chain in the carbohydrate moiety of the macromolecule using the techniques of paper chromatography, gas-liquid chromatography and ion-exchange chromatography on an amino acid analyser. Rhamnose, glucose, galactose, glucosamine and galactosamine were detected as hypothetical components of the core in the lipopolysaccharide composition, as well as 2-keto-3-deoxyoctonic acid, heptose, alpha-alanine and phosphorus, usual components of the core in Pseudomonas. The following predominant fatty acids were identified in the composition of lipid A using the techniques of gas-liquid chromatography with standard compounds and gas-liquid mass spectrometry: 3-OH C10:0 (14.4%), C12:0 (30.5%), 2-OH C12:0 (14.9%), 3-OH C12:0 (17.4%), C16:0 (9.9%). The serological relationship between P. aurantiaca strains was studied, and their phylogenetic relationship with P. fluorescens is discussed.  相似文献   

17.
G M Patton  J M Lowenstein 《Biochemistry》1979,18(14):3186-3188
Fatty acid synthesis by perfused livers of rat is measured by using D2O as tracer. The newly synthesized, deuterium-labeled fatty acids are separated from unlabeled fatty acids by gas chromatography using glass capillary columns. The areas of the deuterium-labeled peaks are proportional to the amounts of fatty acids synthesized. The absolute amounts of the individual fatty acids synthesized are obtained by use of an internal standard. The number of deuterium atoms incorporated, as determined by mass spectrometry, is proportional to the D2O concentration of the perfusate, except at very high concentrations of D2O. The relative retention times of the newly synthesized, deuterium-labeled fatty acids are proportional to their deuterium content.  相似文献   

18.
MOTIVATION: Comparative metabolic profiling by nuclear magnetic resonance (NMR) is showing increasing promise for identifying inter-individual differences to drug response. Two dimensional (2D) (1)H (13)C NMR can reduce spectral overlap, a common problem of 1D (1)H NMR. However, the peak alignment tools for 1D NMR spectra are not well suited for 2D NMR. An automated and statistically robust method for aligning 2D NMR peaks is required to enable comparative metabonomic analysis using 2D NMR. RESULTS: A novel statistical method was developed to align NMR peaks that represent the same chemical groups across multiple 2D NMR spectra. The degree of local pattern match among peaks in different spectra is assessed using a similarity measure, and a heuristic algorithm maximizes the similarity measure for peaks across the whole spectrum. This peak alignment method was used to align peaks in 2D NMR spectra of endogenous metabolites in liver extracts obtained from four inbred mouse strains in the study of acetaminophen-induced liver toxicity. This automated alignment method was validated by manual examination of the top 50 peaks as ranked by signal intensity. Manual inspection of 1872 peaks in 39 different spectra demonstrated that the automated algorithm correctly aligned 1810 (96.7%) peaks. AVAILABILITY: Algorithm is available upon request.  相似文献   

19.
A high-performance liquid chromatography (HPLC) method for separation of the alkylacyl and diacyl analogs of choline glycerophospholipids (CGP) of guinea pig polymorphonuclear leukocytes and their molecular species is described. CGP were hydrolyzed with phospholipase D and then methylated with diazomethane to convert them to dimethylphosphatidates. The dimethylphosphatidates were then separated into the alkylacyl and diacyl subclasses by HPLC on a silica gel column within 15 min. The alkylacyl and diacyl analogs were then separated into individual molecular species by reverse-phase HPLC. Dimethylphosphatidates were resolved into 15 separate peaks, and 11-16 different molecular species of alkylacyl and diacyl glycerophosphocholines were identified on gas-liquid chromatography. The present results indicate that the CGP of polymorphonuclear leukocytes are composed of 27 major molecular species. In the alkylacyl subclass, the most predominant species was the 16:0-18:2 species (32%), followed by the 18:1-18:2 (18%), 16:0-16:0 (16%), and 16:0-18:1 (15%) species. The diacyl type consisted mainly of species with 18:2 at the 2-position, such as the 16:0-18:2, 18:0-18:2, and 18:1-18:2 species, the total percentage of which was 57%.  相似文献   

20.
Gas-liquid chromatographic determination of human fecal bile acids   总被引:4,自引:0,他引:4  
A method for the determination of total bile acids in human feces that is suitable for routine application is described and discussed. Bile acids are extracted from freeze-dried feces with acetic acid and toluene, in the presence of the internal standard 23-nordeoxycholic acid. After saponification of the extract, bile acids and the internal standard are methylated and converted by mild chromic acid oxidation into their ketonic derivatives. The resultant mixture of a few stable compounds can be separated and measured quantitatively by gas-liquid chromatography on a methylsiloxane polymer. A reference bile acid mixture including the internal standard is also taken through the entire procedure with each series of samples. It has been demonstrated that, in spite of the omission of the usual purification steps, the method is specific for bile acids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号