首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Biomechanics of below-knee amputee gait   总被引:6,自引:0,他引:6  
Sagittal plane biomechanical and EMG analyses from eight below knee (B/K) amputee trials demonstrate considerably modified motor patterns from the residual muscles at the hip and knee. Five SACH fittings, two Uniaxial and one Gressinger prostheses were analysed. Moments of force and mechanical power were analysed on all eight trials and EMG profiles are reported for three of the amputees fitted with SACH prostheses. The findings can be summarized as follows: 1. All eight trials had similar internal moment of force patterns at the ankle. A dorsiflexor moment commenced at heel contact and continued for the first third of stance. The prostheses generated a plantarflexor moment for the balance of stance which increased in late stance to about 2/3 that seen in normals. 2. The two Uniaxial prostheses showed a 20% recovery of stored energy which was returned at push-off. The recovery by the Gressinger fitting was 30%. 3. For all but the Gressinger prosthesis the knee moment of force was negligible during early stance (when normals have an extensor moment), below normal in late stance and fairly normal during swing. The amputee wearing the Gressinger prosthesis had a normal but slightly reduced pattern of moments of force over the entire stride. 4. All eight trials had hyperactive hip extensors during early and mid-stance which resulted in above-normal energy generation by these concentrically contracting muscles. This compensation makes up for the loss of the major energy generation by the plantarflexors at push-off. 5. The moment of force and power patterns at the hip for all eight trials during late stance and swing were fairly normal.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
Stance phase joint moments, muscle power outputs and mechanical energy characteristics were determined in five normal and five below knee amputee subjects running at 2.8 m s-1. The amputees were studied sequentially on three different prosthetic feet: the SACH foot (solid ankle cushion heel), and two energy storing feet, Seattle and Flex. While wearing the SACH foot, the amputees exhibited major alterations in the distribution and magnitude of muscle power output and muscle work: (1) the total work done by the lower extremity was reduced; (2) the hip extensors became the main source of energy absorption and generation, while in normal subjects the ankle plantarflexors were the major energy generators and the knee extensors the major energy absorbers; (3) the eccentric and concentric knee extensor power outputs were reduced and an abnormal concentric knee flexor power output was noted immediately after heel contact. In four of the amputees, energy storing feet resulted in improvements in the power output and mechanical work characteristics of the lower extremity: (1) the energy storing prosthetic feet generated 2-3 times greater energy than the SACH foot; (2) with the Flex foot the amputees exhibited a more normal pattern and magnitude of hip and knee extensor muscle work. One of the subjects, however, exhibited increased abnormalities with the energy storing prosthetic feet. The amount of energy restored relative to the amount of energy absorbed by each of the prosthetic feet was greater with the energy storing feet than the SACH foot (Flex 84%, Seattle 52%, SACH 31%).  相似文献   

3.
Resultant flexion/extension lower extremity joint moments of four below-knee amputees running between 2.5 and 5.7 m s-1 were computed during stance on their intact and prosthetic limbs. All subjects wore patellar tendon-bearing prostheses with either a SACH or Greissinger foot component. During stance on the prosthesis, the resultant hip extensor moment on the amputated side was greater in magnitude and duration than its counterpart on the intact limb during its corresponding stance period. Since the artificial foot was planted on the ground, such a moment may help control knee flexion and promote knee extension of the residual limb. For the three subjects whose knees continued to flex at the beginning of stance, there was a dominant extensor moment about the knee joint during stance on the prosthesis. By contrast, for the fourth subject whose knee remained straight or hyperextended throughout stance on the prosthesis, a flexor moment was dominant.  相似文献   

4.
This paper reports on a methodology developed for studying the effects of various types of prosthetic feet on the gait of trans-femoral amputees. It is shown that an analysis in three planes of motion of not only the prosthetic, but also the sound limb provides important information on the performance of prosthetic feet. Two male trans-femoral amputees were tested with four different prosthetic feet; the Springlite II, Carbon Copy III, Seattle LightFoot and the Multiflex foot. A detailed analysis of the results of one amputee and a summary of the most important results of a second subject is presented. The tests were carried out at normal (1.16 m s(-1)) and fast (1.56 m s(-1)) walking speeds. Three dimensional gait analysis was carried out to derive the time curves of the joint angles, intersegmental moments and power at the ankle, knee and hip joints at both the prosthetic and sound sides. A higher first peak of the ground reaction force at the sound side with the Seattle LightFoot compared to that with the Springlite II, may be the result of the lower late stance dorsiflexion angle with the former. Compared to the other two feet, the Carbon Copy III and the Springlite II showed higher prosthetic dorsiflexing moments and positive power at late stance, which could assist in the push-off. The 3D intersegmental loads at the ankle and knee can be used as a guide for design and for compilation of standards for testing of lower limb prostheses incorporating flexible feet.  相似文献   

5.
The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Test were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials. Patient acceptance is not straightforward since knee flexion during stance phase is associated with knee buckling.  相似文献   

6.
Powered knee-ankle prostheses are capable of providing net-positive mechanical energy to amputees. Yet, there are limitless ways to deliver this energy throughout the gait cycle. It remains largely unknown how different combinations of active knee and ankle assistance affect the walking mechanics of transfemoral amputees. This study assessed the relative contributions of stance phase knee swing initiation, increasing ankle stiffness and powered plantarflexion as three unilateral transfemoral amputees walked overground at their self-selected walking speed. Five combinations of knee and ankle conditions were evaluated regarding the kinematics and kinetics of the amputated and intact legs using repeated measures analyses of variance. We found eliminating active knee swing initiation or powered plantarflexion was linked to increased compensations of the ipsilateral hip joint during the subsequent swing phase. The elimination of knee swing initiation or powered plantarflexion also led to reduced braking ground reaction forces of the amputated and intact legs, and influenced both sagittal and frontal plane loading of the intact knee joint. Gradually increasing prosthetic ankle stiffness influenced the shape of the prosthetic ankle plantarflexion moment, more closely mirroring the intact ankle moment. Increasing ankle stiffness also corresponded to increased prosthetic ankle power generation (despite a similar maximum stiffness value across conditions) and increased braking ground reaction forces of the amputated leg. These findings further our understanding of how to deliver assistance with powered knee-ankle prostheses and the compensations that occur when specific aspects of assistance are added/removed.  相似文献   

7.
The Terry Fox jogging (TFJ) prosthesis was developed at Chedoke-McMaster Hospital to alleviate the asymmetric jogging pattern experienced by above-knee amputees when attempting to jog with conventional walking prostheses. This prosthesis features a spring-loaded, telescoping shank designed to eliminate any vaulting action and control the trunk motion during stance. The spring is intended to attenuate the impact forces and release its stored energy at push-off to provide momentum transfer to the jogger. This prosthesis was comprehensively assessed in the gait laboratory, by evaluating the kinematics, energy and power flow patterns of an above-knee amputee jogger wearing the TFJ prosthesis. Included in the assessment is the ability of the prosthesis to satisfy a set of relevant design criteria that have been established from non-amputee jogging patterns. An increased swing phase time for the prosthetic limb and the need to have the knee hyperextended throughout the stance phase contributed to an asymmetric jogging style. The telescoping action did lower the amputee's centre of mass, thereby reducing the vaulting effect. However, the spring only imparted a lifting action to the jogger and the ground reaction forces were double those of a non-amputee jogger. These findings clearly indicate a need to redesign the TFJ prosthesis and are being incorporated in the design of a new physiological jogging prosthesis.  相似文献   

8.
A simple spring mechanics model can capture the dynamics of the center of mass (CoM) during human walking, which is coordinated by multiple joints. This simple spring model, however, only describes the CoM during the stance phase, and the mechanics involved in the bipedality of the human gait are limited. In this study, a bipedal spring walking model was proposed to demonstrate the dynamics of bipedal walking, including swing dynamics followed by the step-to-step transition. The model consists of two springs with different stiffnesses and rest lengths representing the stance leg and swing leg. One end of each spring has a foot mass, and the other end is attached to the body mass. To induce a forward swing that matches the gait phase, a torsional hip joint spring was introduced at each leg. To reflect the active knee flexion for foot clearance, the rest length of the swing leg was set shorter than that of the stance leg, generating a discrete elastic restoring force. The number of model parameters was reduced by introducing dependencies among stiffness parameters. The proposed model generates periodic gaits with dynamics-driven step-to-step transitions and realistic swing dynamics. While preserving the mimicry of the CoM and ground reaction force (GRF) data at various gait speeds, the proposed model emulated the kinematics of the swing leg. This result implies that the dynamics of human walking generated by the actuations of multiple body segments is describable by a simple spring mechanics.  相似文献   

9.
Joint reaction forces, moments and powers are important in interpreting gait mechanics and compensatory strategies used by patients walking with above-knee prostheses. Segmental anthropometrics, required to calculate joint moments, are often estimated using data from cadaver studies. However, these values may not be accurate for patients following amputation as prostheses are composed of non-biologic material. The purpose of this study was to compare joint moments using anthropometrics calculated from cadaver studies versus direct measurements of the residual limb and prosthesis for children with an above-knee amputation. Gait data were collected for four subjects with above-knee prostheses walking at preferred and fast speeds. Joint moments were computed using anthropometrics from cadaver studies and direct measurements for each subject. The difference between these two methods primarily affected the inertia couple (Ialpha term) and the inertial effect due to gravity, which comprised a greater percentage of the total joint moment during swing as compared to stance. Peak hip and knee flexor and extensor moments during swing were significantly greater when calculated using cadaver data (p<0.05). These differences were greater while walking fast as compared to slow speeds. A significant difference was not found between these two methods for peak hip and knee moments during stance. A significant difference was found for peak ankle joint moments during stance, but the magnitude was not clinically important. These results support the use of direct measurements of anthropometry when examining above-knee prosthetic gait, particularly during swing.  相似文献   

10.
In this study, we developed an approach for prosthetic foot design incorporating motion analysis, mechanical testing and computer analysis. Using computer modeling and finite element analysis, a three-dimensional (3D), numerical foot model of the solid ankle cushioned heel (SACH) foot was constructed and analyzed based upon loading conditions obtained from the gait analysis of an amputee and validated experimentally using mechanical testing. The model was then used to address effects of viscoelastic heel performance numerically. This is just one example of the type of parametric analysis and design enabled by this approach. More importantly, by incorporating the unique gait characteristics of the amputee, these parametric analyses may lead to prosthetic feet more appropriately representing a particular user's needs, comfort and activity level.  相似文献   

11.
Conventional designs of an above-knee prosthesis are based on mechanisms with mechanical properties (such as friction, spring and damping coefficients) that remain constant during changing cadence. These designs are unable to replace natural legs due to the lack of active knee joint control. Since the nonlinear and time-varying dynamic coupling between the thigh and the prosthetic limb is high during swing phase, an adaptive control is employed to control the knee joint motion. Two dimensional simulation indicates that the adaptive controller can improve the appearance of gait pattern. It is adaptable to walking speed and can compensate for the variations of hip moment, hip trajectory and toe-off conditions.  相似文献   

12.

In this study, we developed an approach for prosthetic foot design incorporating motion analysis, mechanical testing and computer analysis. Using computer modeling and finite element analysis, a three-dimensional (3D), numerical foot model of the solid ankle cushioned heel (SACH) foot was constructed and analyzed based upon loading conditions obtained from the gait analysis of an amputee and validated experimentally using mechanical testing. The model was then used to address effects of viscoelastic heel performance numerically. This is just one example of the type of parametric analysis and design enabled by this approach. More importantly, by incorporating the unique gait characteristics of the amputee, these parametric analyses may lead to prosthetic feet more appropriately representing a particular user's needs, comfort and activity level.  相似文献   

13.
Lower limb amputees have decreased balance during daily ambulation compared to nonamputees. An optimally compliant torsion adapter, which enables transverse plane rotation at the socket–pylon junction may reduce limb asymmetries and improve comfort leading to increased confidence and stability during gait. The purpose of this study was to determine if the presence of a torsion adapter affects amputee sensitivity to local perturbations (local dynamic stability) during straight-line walking and during a turning task. Ten unilateral transtibial amputees were fit with a torsion and rigid adapter in random order and blinded to the condition. After a 3-week acclimation period, kinematic data were collected while subjects walked in a straight-line on a treadmill and around a 1-m radius circular path at constant speed. Maximum finite-time Lyapunov exponents (λ), an estimator of local dynamic stability, were calculated for the amputee’s sagittal plane hip, knee and ankle angles for each condition. The prosthetic limb λ was greater during a turn compared to straight-line walking, suggesting amputees are less stable while turning. There were no statistically significant differences found in λ between adapters during both walking conditions, suggesting the torsion adapter had no effect on amputee stability; however, high inter-subject variability due to the examined population and turning task may have masked a small decrease in prosthetic limb hip and knee stability for the torsion adapter during straight-line gait. Therefore, the torsion adapter’s added degree of freedom may have a small adverse effect on prosthetic limb stability during straight-line walking and no effect on turning.  相似文献   

14.
15.
The purpose of this study was to test the hypothesis of whether the center of rotation (COR) in the transverse plane of the knee is in the medial side during normal walking in a manner similar to that previously described during non-ambulatory activities. The kinematics for normal knees was obtained from 46 knees during normal walking using the point cluster technique. The COR of the medial-lateral axis of the femur relative to the tibia was determined during the stance phase of walking. The hypothesis that the COR is in the medial side during stance was not supported by this study. The average COR during the stance phase of walking was in the lateral compartment for all 46 knees. In addition, the instantaneous COR occurred on the medial side on average <25% of the time during the stance phase. Thus, while the COR is predominantly on the lateral side of the knee during walking, the normal function of the knee during walking is associated with both lateral and medial pivoting. These results also demonstrate the importance of describing knee kinematics in the context of a specific activity or the constraints of the test conditions.  相似文献   

16.
The purpose of the present study was to determine the effects of orthoses designed to support the forefoot and rearfoot on the kinematics and kinetics of the lower extremity joints during walking. Fifteen participants volunteered for this study. Kinematic and kinetic variables during overground walking were compared with the participants wearing sandals without orthoses or sandals with orthoses. Orthoses increased knee internal abduction moment during late stance and knee abduction angular impulse, and reduced the medial ground reaction force during late stance, adduction free moment, forefoot eversion angle, ankle inversion moment and angular impulse, hip adduction angle, hip abduction moment, and hip external rotation moment and angular impulse (p<0.05). Orthoses decreased the torsional forces on the lower extremity and reduced the loading at the hip during walking. These findings combined with our previous studies and those of others suggest that forefoot abnormalities are critically important in influencing lower extremity kinematics and kinetics, and may underlie some non-traumatic lower extremity injuries.  相似文献   

17.
The purpose of this study was to determine the changes in the axis of rotation of the knee that occur during the stance phase of running. Using intracortical pins, the three-dimensional skeletal kinematics of three subjects were measured during the stance phase of five running trials. The stance phase was divided into equal motion increments for which the position and orientation of the finite helical axes (FHA) were calculated relative to a tibial reference frame. Results were consistent within and between subjects. At the beginning of stance, the FHA was located at the midepicondylar point and during the flexion phase moved 20mm posteriorly and 10mm distally. At the time of peak flexion, the FHA shifted rapidly by about 10-20mm in proximal and posterior direction. The angle between the FHA and the tibial transverse plane increased gradually during flexion, to about 15 degrees of medial inclination, and then returned to zero at the start of the extension phase. These changes in position and orientation of FHA in the knee should be considered in analyses of muscle function during human movement, which require moment arms to be defined relative to a functional rotation axis. The finding that substantial changes in axis of rotation occurred independent of flexion angle suggests that musculoskeletal models must have more than one kinematic degree-of-freedom at the knee. The same applies to the design of knee prostheses, if the goal is to restore normal muscle function.  相似文献   

18.
The foot progression angle (FPA) influences knee loading during gait, but its determinants are unclear. The purpose of this study was to compare FPA between males and females and also examine the association between lower extremity kinematics during gait, hip strength, and the FPA. 25 males and 25 females completed 5 gait trials while FPA and frontal and transverse plane hip and knee angles were calculated from the dominant limb during the foot flat portion of stance. Hip extensor/flexor, abductor/adductor, and internal/external rotator strength were evaluated using maximum voluntary isometric contractions. One-way MANOVAs compared gait and strength outcomes. Stepwise regression assessed the association between FPA, and MVIC and kinematics after accounting for speed in males and females. There was no difference in FPA between sexes (p > 0.05), but females had greater frontal and transverse plane hip angles compared with males (all p < 0.05). Greater hip abduction (p = 0.02) strength was associated with greater FPA, but only in males. In males, greater hip abductor strength may contribute to a more neutral position of the foot during gait, which could help maintain an equal knee loading distribution. Our results suggest that there are sex specific control strategies to achieve a similar FPA during gait.  相似文献   

19.
We describe segment angles (trunk, thigh, shank, and foot) and joint angles (hip, knee, and ankle) for the hind limbs of bonobos walking bipedally ("bent-hip bent-knee walking," 17 sequences) and quadrupedally (33 sequences). Data were based on video recordings (50 Hz) of nine subjects in a lateral view, walking at voluntary speed. The major differences between bipedal and quadrupedal walking are found in the trunk, thigh, and hip angles. During bipedal walking, the trunk is approximately 33-41 degrees more erect than during quadrupedal locomotion, although it is considerably more bent forward than in normal human locomotion. Moreover, during bipedal walking, the hip has a smaller range of motion (by 12 degrees ) and is more extended (by 20-35 degrees ) than during quadrupedal walking. In general, angle profiles in bonobos are much more variable than in humans. Intralimb phase relationships of subsequent joint angles show that hip-knee coordination is similar for bipedal and quadrupedal walking, and resembles the human pattern. The coordination between knee and ankle differs much more from the human pattern. Based on joint angles observed throughout stance phase and on the estimation of functional leg length, an efficient inverted pendulum mechanism is not expected in bonobos.  相似文献   

20.
The study aimed to test the hypothesis that the restraining role of the anterior cruciate ligament (ACL) of the knee is significant during the activities of normal walking and stair ascent. The role of the ACL was determined from the effect of ACL excision on tibiofemoral displacement patterns measured in vitro for fresh-frozen knee specimens subjected to simulated knee kinetics of walking (n = 12) and stair ascent (n = 7). The knee kinetics were simulated using a newly developed dynamic simulator able to replicate the sagittal-plane knee kinetics with reasonable accuracy while ensuring unconstrained tibiofemoral kinematics. The displacements were measured using a calibrated six degree-of-freedom electromechanical goniometer. For the simulation of the walking cycle, two types of knee flexion/extension moment patterns were used: the more common "biphasic" pattern, and an extensor muscle force intensive pattern. For both of these patterns, the restraining role of the ACL to tibial anterior translation was found to be significant throughout the stance phase and in the terminal swing phase, when the knee angle was in the range of 4 degrees to 30 degrees. The effect of ACL excision was an increase in tibial anterior translation by 4 mm to 5 mm. For the stair ascent cycle, however, the restraining role of the ACL was significant only during the terminal stance phase, and not during the initial and middle segments of the phase. Although, in these segments, the knee moments were comparable to that in walking, the knee angle was in the range of 60 degrees to 70 degrees. These results have been shown to be consistent with available data on knee mechanics and ACL function measured under static loading conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号