首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
A high order method for measuring urea concentrations in milk and milk powder was developed. The method can be applied to certify the concentration of urea in some new milk and milk powder CRMs. This high accurate method for analysis of milk is valuable given the inherent challenges associated with the complexity of the sample matrix. A measurement procedure based on gas chromatography/isotope dilution mass spectrometry (GC/IDMS) was developed. Samples were pre-treated with acetonitrile to remove proteins and the method was applied to determine urea concentrations in milk and milk powder. Excellent precision was obtained, with within- and between-set coefficients of variation of 0.15–0.46 and 0.18–0.65%, respectively. The measurement uncertainty is evaluated. The method can trace to mass.  相似文献   

2.
YH439 is a potential drug candidate for the treatment of various hepatic disorders. YH439 and its three metabolites have been identified in rat urine by liquid chromatography–mass spectrometry (LC–MS) and by gas chromatography (GC)–MS. Identification of YH439 and its metabolites was established by comparing their GC retention times and mass spectra with those of the synthesized authentic standards. Both electron impact- and positive chemical ionization MS have been evaluated. The metabolism study was performed in the rat using oral administration of the drug. A major metabolite (YH438) was identified as the N-dealkylation product of YH439. Other identified metabolites were caused by the loss of the methyl thiazolyl amine group (metabolite II) from YH439, the isopropyl hydrogen malonate group (metabolite IV) and the decarboxylated product (metabolite III) of metabolite II.  相似文献   

3.
A simple, sensitive and reproducible gas chromatographic–mass spectrometric method was developed for monitoring ractopamine (RAC) and clenbuterol (CLB) in feeds. Feed samples were extracted with 0.1 M perchloric acid, centrifuged, neutralized, followed by liquid–liquid extraction with ethyl acetate-isopropanol (9:1, v/v). The concentrated extracts were dissolved in 0.02 M NH4Ac (pH 5.2), and applied to a solid phase extraction SCX cartridge for cleanup. The drugs were eluted with 3% (v/v) ammonia hydroxide in methanol, and the eluate was evaporated to dryness. The residue was derivatized with N,O-bis (trimethylsilyl) trifluoroacetamide at 80 °C for 1 h, and cooled, then analyzed by gas chromatography–mass spectrometry. The selected ions monitoring mode was performed at m/z 179, 250, 267 and 502 for RAC, and m/z 86, 243, 262 and 277 for CLB. Recoveries of RAC and CLB from concentrated feeds and premix fortified at 10, 100 and 5000 μg/kg were between 64.6 and 84.2%, with relative standard deviations of less than 15%. The limits of detection were about 4 μg/kg for RAC and 2 μg/kg for CLB.  相似文献   

4.
Advanced analytical modern technology such as coupling a gas chromatography to a mass spectrometric technique provides sufficient information to the environmental and analytical chemists to identify the presence of a variety of components of the specific volatile organic product, determine the degree of the product weathering and in some instances estimate the age of the product as well in the testing sample. In this study, we estimated BTEX in groundwater sample by using gas chromatography–mass spectrometry (GC–MS) after standardization of this technique for advancement towards purification check of water samples in the petro-polluted regions of the soil.  相似文献   

5.
Oestrogens, such as oestrone (E1), 17β-oestradiol (E2), oestriol (E3) and their biologically active metabolites 2-methoxyoestrone (2-MeOE1), 2-hydroxyoestradiol (2-OHE2) 16-ketooestradiol (16-OE2), 16-epioestriol (16-epiE3), as well as testosterone (T) play an important role in physiological and pathological developmental processes during human development. We therefore aimed at developing an isotope dilution/bench top gas chromatography–mass spectrometry (ID/GC–MS) method, based on benchtop GC–MS, for the simultaneous determination (‘profiling’) of the above analytes in children. The method consisted of equilibration of urine (5 ml) with a cocktail containing stable isotope-labelled analogues of the analytes as internal standards ([2,4-2H2]E1, [2,4,16,16-2H4]E2, [2,4,17-2H3]E3, [16,16,17-2H3]T, [1,4,16,16-2H4]2-MeOE1, [1,4,16,16,17-2H5]2-OHE2, [2,4,15,15,17-2H5]16-OE2 and [2,4-2H2]16-epiE3). Then, solid-phase extraction (C18 cartridges), enzymatic hydrolysis (sulphatase from Helix pomatia (type H-1)), re-extraction, purification by anion exchange chromatography and derivatisation to trimethylsilyl ethers followed. The samples were analysed by GC–MS (Agilent GC 6890N/5975MSD; fused silica capillary column 25 m × 0.2 mm i.d., film 0.10 μm). Calibration plots were linear and showed excellent reproducibility with coefficients of determination (r2) between 0.999 and 1.000. Intra- and inter-assay coefficients of variation (CV) were <2.21% for all quantified metabolites. Sensitivity was highest for 2-OHE2 (0.25 pg per absolute injection: signal-to-noise ratio (S/N) = 3) and lowest for 16-epiE3 (2 pg per absolute injection: S/N = 2.6), translating into corresponding urine sample analyte concentrations of 0.025 ng ml?1 and 0.2 ng ml?1, respectively. Accuracy – determined in a two-level spike experiment – showed relative errors ranging between 0.15% for 16-OE2 and 11.63% for 2-OHE2. Chromatography showed clear peak shapes for the components analysed. In summary, we describe a practical, sensitive and specific ID/GC–MS assay capable of profiling the above-mentioned steroids in human urine from childhood onwards.  相似文献   

6.
Gas chromatography–mass spectrometry (GC–MS) was compared with gas chromatography–combustion–isotope ratio mass spectrometry (GC–C–IRMS) for measurements of cholesterol 13C enrichment after infusion of labeled precursor ([13C1,2]acetate). Paired results were significantly correlated, although GC–MS was less accurate than GC–C–IRMS for higher enrichments. Nevertheless, only GC–MS was able to provide information on isotopologue distribution, bringing new insights to lipid metabolism. Therefore, we assessed the isotopologue distribution of cholesterol in humans and dogs known to present contrasted cholesterol metabolic pathways. The labeled tracer incorporation was different in both species, highlighting the subsidiarity of GC–MS and GC–C–IRMS to analyze in vivo stable isotope studies.  相似文献   

7.
Folates act as essential coenzymes in many biological pathways. Alteration in folate form distribution might have biological significance, especially in relation to certain genetic polymorphisms. We developed a stable-isotope dilution ultra performance liquid chromatography–mass spectrometry (UPLC–MS/MS) method for quantification of the folate forms 5-methyltetrahydrofolate (5-methylTHF), 5-formylTHF, 5,10-methenylTHF, THF, and folic acid in serum. After extraction using an ion exchange and mixed mode solid-phase, samples were separated and detected using an UPLC–MS/MS system. The quantification limits were between 0.17 nmol/L (5-formylTHF) and 1.79 nmol/L (THF), and the assay was linear up to 100 nmol/L (5-methylTHF) and 10 nmol/L (5-formylTHF, 5,10-methenylTHF, THF, and folic acid). The intraassay CVs for 5-methylTHF and 5-formylTHF were 2.0% and 7.2%, respectively. Mean recoveries were between 82.3% for THF and 110.8% for 5,10-methenylTHF. Concentrations of total folate measured by the new method showed a strong correlation with those measured by an immunologic assay (r = 0.939; p < 0.001). The mean total folate from 32 apparently healthy subjects was 18.09 nmol/L, of which 87.23% was 5-methylTHF. Concentrations of homocysteine showed a better correlation to the total folate measured by the new method compared to that obtained by an immunologic assay. We also confirmed that MTHFR polymorphism has a significant effect on folate distribution in this small population of non-supplemented subjects.  相似文献   

8.
A GC–MS assay for stereoselective determination of tramadol and its pharmacologically active phase I metabolite O-desmethyltramadol in human urine was developed. Nefopam was used as internal standard. The method involves a simple solid phase extraction with chiral analysis by gas chromatography–electron ionization mass spectrometry using m/z 263; 58, 249; 58, and 179; 58 for the determination of concentration of tramadol, O-desmethyltramadol and internal standard, respectively. Chromatography was performed on a Rt-βDEXcst column containing alkylated beta-cyclodextrins as a chiral selector. The calibration curves were linear in the concentration range 0.1–20 μg/mL (R2  0.998). Intra-day accuracies ranged between 97.2–104.9%, 96.1–103.2%, and 97.3–102.8% at the lower, intermediate, and high concentration for all analytes, respectively. Inter-day accuracies ranged between 95.2–105.7%, 99.1–105.2%, and 96.5–101.2% at the lower, intermediate, and high concentration for all analytes, respectively. This method was successfully used to determine the concentration of enantiomers of T and ODT in a pharmacogenetic study.  相似文献   

9.
Urinary metabolic pattern after the therapeutic peroral dose of dihydrocodeine tartrate to six human volunteers has been explored. Using the GC–MS analytical method, we have found that the major part of the dose administered is eliminated via urine within the first 24 h. However, the analytical monitoring of dihydrocodeine and its metabolites in urine was still possible 72 h after the dose was administered. The dihydrocodeine equivalent amounts excreted in urine in 72 h ranged between 32 and 108% of the dose, on average 62% in all individuals. The major metabolite excreted into urine was a 6-conjugate of dihydrocodeine, then in a lesser amount a 6-conjugate of nordihydrocodeine (both conjugated to approximately 65%). The O-demethylated metabolite dihydromorphine was of a minor amount and was 3,6-conjugated in 85%. Traces of nordihydromorphine and hydrocodone were confirmed as other metabolites of dihydrocodeine in our study. This information can be useful in interpretation of toxicological findings in forensic practice.  相似文献   

10.
Alkylresorcinols (ARs) are phenolic lipids present at high concentrations in the outer parts of rye and wheat kernels and have been proposed as biomarkers for intake of whole grain and bran products of these cereals. AR are absorbed in the small intestine and after hepatic metabolism two major metabolites, 3,5-dihydroxybenzoic acid (DHBA) and 3-(3,5-dihydroxyphenyl)-1-propanoic acid (DHPPA), are excreted in urine either as such or as conjugates. Urine samples from nine individuals were incubated with different enzymes to assess type and extent of conjugates. In comparison with DHBA, which was mostly found in the free form, the less polar DHPPA was conjugated to a greater extent and the major conjugates were glucuronides. In this method, urine samples were hydrolyzed using β-glucuronidase from Helix pomatia and syringic acid was used as internal standard. Samples, silylated with BSTFA, were analyzed by GC–MS utilizing a BP-5 fused silica capillary column and single ion monitoring of molecular ions (m/z 370 [DHBA], m/z 398 [DHPPA]). Recoveries of DHBA and DHPPA were estimated to be 94% and 93%, respectively. The average intra-assay/inter-assay coefficients of variation were 4.9/5.7% for DHBA and 7.6/9.3% for DHPPA.  相似文献   

11.
A simple, reliable and sensitive gas chromatographic–mass spectrometric method was devised to determine the level of mannitol in various human brain tissues obtained at autopsy. Mannitol was extracted with 10% trichloroacetic acid solution which effectively precipitated brain tissues. The supernatant was washed with tert.-butyl methyl ether to remove other organic compounds and to neutralize the aqueous solution. Mannitol was then derivatized with 1-butaneboronic acid and subjected to GC–MS. Erythritol was used as an internal standard. For quantitation, selected ion monitoring with m/z 127 and 253 for mannitol and m/z 127 for internal standard were used. Calibration curves were linear in concentration range from 0.2 to 20 μg/0.1 g and correlation coefficients exceeded 0.99. The lower detection limit of mannitol in distilled water was 1 ng/0.1 g. Mannitol was detected in control brain tissues, as a biological compound, at a level of 50 ng/0.1 g. The precision of this method was examined with use of two different concentrations, 2 and 20 μg/0.1 g, and the relative standard deviation ranged from 0.8 to 8.3%. We used this method to determine mannitol in brain tissues from an autopsied individual who had been clinically diagnosed as being brain dead. Cardiac arrest occurred 4 days later.  相似文献   

12.
1. The metabolism of flavanone in the rat was studied after oral or intraperitoneal administration of the compound. Flavone and flav-3-ene together with five other unidentified minor metabolites were excreted in the urine. 2. The formation of flavanone metabolites was not suppressed by the administration of high doses of the antibacterial compounds aureomycin and phthaloylsulphathiazole. 3. No aromatic acids that could be attributed to ring cleavage of flavanone were detected. 4. Administration of 100 or 200mg of flavanone daily per rat caused some deaths during the 7-14-day period. 5. The application of combined gas-liquid chromatography/mass spectrometry and proton nuclear-magnetic-resonance spectroscopy to the separation and identification of the flavanone metabolites is described. 6. Measurement of the two major flavanone metabolites was carried out by gas-liquid chromatography.  相似文献   

13.
Methods of isotope-dilution gas chromatography–mass spectrometry (GC–MS) are described for the determination of styrene and styrene-7,8-oxide (SO) in blood. Styrene and SO were directly measured in pentane extracts of blood from 35 reinforced plastics workers exposed to 4.7–97 ppm styrene. Using positive ion chemical ionization, styrene could be detected at levels greater than 2.5 μg/l blood and SO at levels greater than 0.05 μg/l blood. An alternative method for measurement of SO employed reaction with valine followed by derivatization with pentafluorophenyl isothiocyanate and analysis via negative ion chemical ionization GC–MS–MS (SO detection limit=0.025 μg/l blood). The detection limits for SO by these two methods were 10–20-fold lower than gas chromatographic assays reported earlier, based upon either electron impact MS or flame ionization detection. Excellent agreement between the two SO methods was observed for standard calibration curves while moderate to good agreement was observed among selected reinforced plastics workers (n=10). Levels of styrene in blood were found to be proportional to the corresponding air exposures to styrene, in line with other published relationships. Although levels of SO in blood, measured by the direct method, were significantly correlated with air levels of either styrene or SO among the reinforced plastics workers, blood concentrations were much lower than previously reported at a given exposure to styrene. The two assays for SO in blood appear to be unbiased and to have sufficient sensitivity and specificity for applications involving workers exposed to styrene and SO during the manufacture of reinforced plastics.  相似文献   

14.
Haloacetic acids (HAAs) are water disinfection byproducts (DBPs) formed by the reaction of chlorine oxidizing compounds with natural organic matter in water containing bromine. HAAs are second to trihalomethanes as the most commonly detected DBPs in surface drinking water and swimming pools. After oral exposure (drinking, showering, bathing and swimming), HAAs are rapidly absorbed from the gastrointestinal tract and excreted in urine. Typical methods used to determine these compounds in urine (mainly from rodents) only deal with one or two HAAs and their sensitivity is inadequate to determine HAA levels in human urine, even those manual sample preparation protocols which are complex, costly, and neither handy nor amenable to automation. In the present communication, we report on a sensitive and straightforward method to determine the nine HAAs in human urine using static headspace (HS) coupled with GC–MS. Important parameters controlling derivatisation and HS extraction were optimised to obtain the highest sensitivity: 120 μl of dimethylsulphate and 100 μl of tetrabutylammonium hydrogen sulphate (derivatisation regents) were selected, along with an excess of Na2SO4 (6 g per 12 ml of urine), an oven temperature of 70 °C and an equilibration time of 20 min. The method developed renders an efficient tool for the precise and sensitive determination of the nine HAAs in human urine (RSDs ranging from 6 to 11%, whereas LODs ranged from 0.01 to 0.1 μg/l). The method was applied in the determination of HAAs in urine from swimmers in an indoor swimming pool, as well as in that of non-swimmers. HAAs were not detected in the urine samples from non-swimmers and those of volunteers before their swims; therefore, the concentrations found after exposure were directly related to the swimming activity. The amounts of MCAA, DCAA and TCAA excreted from all swimmers are related to the highest levels in the swimming pool water.  相似文献   

15.
《Free radical research》2013,47(8):651-656
Abstract

Malondialdehyde (MDA) is considered to be a biomarker for enzymatic degradation and lipid peroxidation of polyunsaturated fatty acids. Usually, MDA determination from different biological materials is performed by reaction with thiobarbituric acid (TBA) followed by high-performance liquid chromatography (HPLC) analysis and fluorometric detection. As this method lacks specificity and sensitivity, we developed a gas chromatography–mass spectrometry (GC–MS) method based on derivatization of MDA with 2,4-dinitrophenylhydrazine. Representative ions in negative ion chemical ionization (NICI) mode were recorded at m/z 204 for MDA and at m/z 206 for the deuterated analogon (MDA-d2) as internal standard. This stable and precise GC–MS method showed good linearity (r2 = 0.999) and higher specificity and sensitivity than the HPLC method and was validated for both total MDA (t-MDA) and free MDA (f-MDA). Within-day precisions were 1.8–5.4%, between-day precisions were 4.8–9.2%; and accuracies were between 99% and 101% for the whole calibration range (0.156–5.0 μmol/L for t-MDA and 0.039–0.625 μmol/L for f-MDA). Although comparison of t-MDA levels from GC–MS and HPLC results using Passing–Bablok regression analysis as well as Bland–Altman plot showed a correlation of the data, a tendency to increased results for the HPLC values was detectable, due to possible formation of unspecific products of the TBA reaction.  相似文献   

16.
Screening of newborns for inborn errors of metabolism (IEM) in China is both a challenging and undeveloped area for gynecologists and pediatricians. Since 1999, the Capital Institute of Pediatrics has been studied as regards screening for IEM using advanced gas chromatography–mass spectrometry (GC–MS) method in collaboration with the Matsumoto Institute of Life Science (MILS), Japan, and has successfully diagnosed 51 cases of IEM in a total of 393 patients. Galactosemia, phenylketonuria and methylmalonic acidemia were the most frequent disorders among 51 cases of IEM. Treatment by suitable drugs and/or diet therapy was very effective in the most cases.  相似文献   

17.
Meconium fatty acid ethyl esters (FAEEs) are currently used as biomarkers to detect heavy prenatal alcohol exposure. We introduce a novel technique to quantify FAEEs in meconium using headspace-solid-phase microextraction (HS-SPME) coupled with gas chromatography–mass spectrometry (GC–MS). This method improves on previous approaches by decreasing sample preparation time, eliminating the need for organic solvents, and reducing the required sample size. Using 50 mg of meconium, the detection limits of FAEEs ranged from 0.05 to 0.16 nmol/g and had good reproducibility making it ideal for routine analysis of clinical samples.  相似文献   

18.
This review will be concerned primarily with a practical yet comprehensive diagnostic procedure for the diagnosis or even mass screening of a variety of metabolic disorders. This rapid, highly sensitive procedure offers possibilities for clinical chemistry laboratories to extend their diagnostic capacity to new areas of metabolic disorders. The diagnostic procedure consists of the use of urine or filter paper urine, preincubation of urine with urease, stable isotope dilution, and gas chromatography–mass spectrometry. Sample preparation from urine or filter paper urine, creatinine determination, stable isotope-labeled compounds used, and GC–MS measurement conditions are described. Not only organic acids or polar ones but also amino acids, sugars, polyols, purines, pyrimidines and other compounds are simultaneously analyzed and quantified. In this review, a pilot study for screening of 22 target diseases in newborns we are conducting in Japan is described. A neonate with presymptomatic propionic acidemia was detected among 10,000 neonates in the pilot study. The metabolic profiles of patients with ornithine carbamoyl transferase deficiency, fructose-1,6-bisphosphatase deficiency or succinic semialdehyde dehydrogenase deficiency obtained by this method are presented as examples. They were compared to those obtained by the conventional solvent extraction methods or by the tandem mass spectrometric method currently done with dried filter blood spots. The highly sensitive, specific and comprehensive features of our procedure are also demonstrated by its use in establishing the chemical diagnosis of pyrimidine degradation defects in order to prevent side effects of pyrimidine analogs such as 5-flurouracil, and the differential diagnosis of three types of homocystinuria, orotic aciduria, uraciluria and other urea cycle disorders. Evaluation of the effects of liver transplantation or nutritional conditions such as folate deficiency in patients with inborn errors of metabolism is also described.  相似文献   

19.
A rapid and systematic strategy based on liquid chromatography–mass spectrometry (LC–MS) profiling and liquid chromatography–tandem mass spectrometry (LC–MS–MS) substructural techniques was utilized to elucidate the degradation products of paclitaxel, the active ingredient in Taxol. This strategy integrates, in a single instrumental approach, analytical HPLC, UV detection, full-scan electrospray MS, and MS–MS to rapidly and accurately elucidate structures of impurities and degradants. In these studies, degradants induced by acid, base, peroxide, and light were profiled using LC–MS and LC–MS–MS methodologies resulting in an LC–MS degradant database which includes information on molecular structures, chromatographic behavior, molecular mass, and MS–MS substructural information. The stressing conditions which may cause drug degradation are utilized to validate the analytical monitoring methods and serve as predictive tools for future formulation and packaging studies. Degradation products formed upon exposure to basic conditions included baccatin III, paclitaxel sidechain methyl ester, 10-deacetylpaclitaxel, and 7-epipaclitaxel. Degradation products formed upon exposure to acidic conditions included 10-deacetylpaclitaxel and the oxetane ring opened product. Treatment with hydrogen peroxide produced only 10-deacetylpaclitaxel. Exposure to high intensity light produced a number of degradants. The most abundant photodegradant of paclitaxel corresponded to an isomer which contains a C3–C11 bridge. These methodologies are applicable at any stage of the drug product cycle from discovery through development. This library of paclitaxel degradants provides a foundation for future development work regarding product monitoring, as well as use as a diagnostic tool for new degradation products.  相似文献   

20.
Liquid chromatography–thermospray mass spectrometry (LC–TSP-MS) using isotope dilution was investigated for quantitative analysis of cortisol, cortisone, prednisolone and prednisone in human plasma. Complete separation attained by a LiChroCART Supersupher reversed-phase column and elution with 0.05 M ammonium formate–tetrahydrofuran–methanol (180:53:17, v/v/v) resulted in a significantly large isotope effect of the deuterium-labeled analogs on the HPLC behavior and caused difficulty in quantification. Reduction of the isotope effect on the retention times using 0.05 M ammonium formate–acetonitrile (65:35, v/v) permitted accurate quantification of cortisol and cortisone by the isotope dilution LC–TSP-MS, although separation between cortisol and prednisone was incomplete.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号