首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The influence of an external magnetic field on the performance of a high-impedance plasma opening switch is studied experimentally. A 1.5-fold increase in the output voltage of a plasma opening switch operating in the erosion mode is achieved by applying an external magnetic field. The magnetic field strength and the parameters of the plasma opening switch at which the maximum output voltage is attained are determined. It is shown experimentally that the predicted dependence of the maximum output voltage on the Marx generator voltage, U POS [MV]=3.6 (U MG [MV])4/7, is confirmed experimentally.  相似文献   

2.
The turbulent properties of conducting fluids in an external constant magnetic field are known to change with increasing field strength. A study is made of the behavior of the second-order structural function of the velocity field in a homogeneous incompressible turbulent fluid in the presence of an external uniform magnetic field. It is shown that, depending on the magnetic field strength, there may be different governing parameters of the system in both the inertial and dissipative intervals of turbulence. This leads to new spectral scalings that are consistent with experimental ones.  相似文献   

3.
A local analysis of the magnetic field near an equilibrium magnetic surface shows that there is generally no relationship between the magnetic field strength and the shape of the surface. However, the relationship exists under additional requirements such as the absence of the toroidal current, symmetry conservation, and the conservation of the magnetic field strength distribution on the nearest surface. An equilibrium magnetic surface can be calculated by specifying three functions of two angular variables—the magnetic field strength, the periodic component of the magnetic potential, and the mean curvature of the surface.  相似文献   

4.
Direct measurements of magnetic fields in a plasma show that current sheets can form in magnetic configurations with an X line in the presence of a longitudinal magnetic field. It is found that, in a plane perpendicular to the X line and to the direction of the main current, the current sheet has two very different dimensions. The tangential and normal components of the magnetic field and current density in the sheet are determined. The influence of the initial conditions (such as the strength of the longitudinal magnetic field, the gradient of the transverse field, and the plasma ion mass) on the current sheet parameters is investigated.  相似文献   

5.
A theoretical analysis of electric and magnetic fields of the heart, based solely upon the scalar multipole expansion, is carried out in order to gain an insight into the interrelation of the data contained in electro- and magnetocardiological measurements. The usual multipole expansion is applied for the electric field, however corresp[nding equivalent multipoles are formulated as idealized generators, having not only flow sources, but also vortex sources of the field. Furthermore, the magnetic field in a homogeneous infinite volume conductor is expressed as a sum of two series, the first being the usual multipole expansion of the nonvortex component of the magnetic field, and the second being a sequence of magnetic fields set up by the aforementioned electric multipole generators reduced to axial form. The former term is uniquely defined by the electric multipole components, but the latter reflects properties of the cardiogenerator that can be revealed only by means of magnetic measurements. Features of the electric and magnetic multipole components as integral characteristics of the cardiogenerator are discussed and concepts of the magnetic centre and magnetic axis of the cardiogenerator are proposed. The analysis is illustrated by examples of simple generator configurations.  相似文献   

6.
A method for simultaneous magnetic field application and intracellular recording is presented. A little used method for magnetic field application was exploited; the field generator consisted of a flat copper sheet through which current was passed to generate a magnetic field. The resultant magnetic field was relatively homogeneous, exhibiting a variation of +/- 5%. This compact, current-sheet field generator was mounted on the condensor of a microscope. The current induced in the intracellular electrode was reduced by injecting current equal and opposite to the induced current into the microelectrode. This step reduces the possibility of cellular effects and voltage artifacts due to the induced electrode current. The technique was used to conduct preliminary studies on the effects of extremely low frequency (ELF) linearly and circularly polarized magnetic fields (1.0 Gauss, 60 and 70 Hz) on miniature end plate potential (mepp) frequency (frequency of neurotransmitter release events) of rat flexor digitorum brevis muscle. The same synapse was utilized for both the sham-exposed control and the exposed experimental halves of an experiment. After 10 min of exposure to a 60-Hz linear field, mepp frequency was significantly increased by 12%, but exposure to a 60-Hz circular field did not significantly alter mepp frequency. Exposure to a 70-Hz linear field did not significantly change mepp frequency, but application of a 70-Hz circular field appears to decrease mepp frequency by 4%. These results indicate that both types of magnetic fields can alter mepp frequency, depending upon the frequency and configuration of the field.  相似文献   

7.
Local synthesis of nested 3D toroidal magnetic surfaces is carried out on the basis of the general theory of surfaces by using magnetic coordinates (generally unknown a priori). An equilibrium magnetic surface is calculated by specifying two functions on the surface (the absolute value of the magnetic field and the distance to the nearest magnetic surface) and three parameters (the rotational transform, pressure gradient, and poloidal current). The choice of the parameters is restricted by the requirement that the surface should be closed toroidally. A method of synthesis of a closed magnetic surface is proposed when two functions—the absolute value of the magnetic field and the major radius—are specified. A set of harmonics of a new type of poloidally preudosymmetric configuration (a toroidal mirror with a large mirror ratio and small rotational transform) is obtained.  相似文献   

8.
Results are presented from experimental studies of low-pressure inductive RF discharges (including those with a capacitive component) employed in plasma technology. It is shown that both the RF power absorbed in the plasma and the electron density depend nonmonotonically on the external magnetic field. Discharge disruptions occurring at critical values of the magnetic field and the spatial redistribution and hysteresis of the plasma parameters were observed when varying the magnetic field and RF generator power. The parameters of the plasma of low-pressure (0.5–5 mTorr) inductive RF discharges were investigated, and the discharge properties related to the redistribution of the RF generator power between the plasma and the discharge external circuit were revealed. The experiments were performed with both conventional unmagnetized inductive plasma sources and plasma sources with a magnetic field.  相似文献   

9.
Choosing the right exposure index for epidemiological studies on 50–60 Hz magnetic fields is difficult due to the lack of knowledge about critical exposure parameters for the biological effects of magnetic fields. This paper uses data from a previously published epidemiological investigation on early pregnancy loss (EPL) to study the methods of evaluating the exposure-response relationship of 50 Hz magnetic fields. Two approaches were used. The first approach was to apply generalized additive modeling to suggest the functional form of the relationship between EPL and magnetic field strength. The second approach evaluated the goodness of fit of the EPL data with eight alternative exposure indices: the 24 h average of magnetic field strength, three indices measuring the proportion of time above specified thresholds, and four indices measuring the proportion of time within specified intensity windows. Because the original exposure data included only spot measurements, estimates for the selected exposure indices were calculated indirectly from the spot measurements using empirical nonlinear equations derived from 24 h recordings in 60 residences. The results did not support intensity windows, and a threshold-type dependence on field strength appeared to be more plausible than a linear relationship. In addition, the study produced data suggesting that spot measurements may be used as surrogates for other exposure indices besides the time average field strength. No final conclusions should be drawn from this study alone, but we hope that this exercise stimulates evaluation of alternative exposure indices in other planned and ongoing epidemiological studies. © 1996 Wiley-Liss, Inc.  相似文献   

10.
The influence of a transverse magnetic field and the working-gas pressure on the rotation frequency of the current channel, as well as on the electric field in the positive column and the cathode voltage drop in a dc gas discharge, was studied experimentally. The working gases were pure hydrogen and hydrogen-methane, hydrogen-argon, and hydrogen-argon-methane mixtures. It is shown that a transverse (with respect to the discharge current) magnetic field stabilizes a normal glow discharge against a transition to an arc discharge at specific absorbed powers above 300 W/cm3. The cathode voltage drop and the electric field in the positive column are measured. It is shown that the electric field does not depend on the magnetic field strength, whereas the cathode voltage drop increases with increasing magnetic field. It is found that the rotation frequency of the current channel is a complicated function of the discharge parameters and attains 400 Hz.  相似文献   

11.
The problem of the excitation of electron waves in a thin-walled annular cold plasma in a cylindrical waveguide by a straight relativistic electron beam in a finite magnetic field is considered. The dispersion properties of a waveguide system with parameters close to the experimental ones are investigated. It is shown that the growth rate of the excited high-frequency plasma wave is comparable to that of the low-frequency wave, which is weakly sensitive to the strength of the longitudinal magnetic field.  相似文献   

12.
We have previously demonstrated that a weak, extremely-low-frequency magnetic field must be coherent for some minimum length of time (≈? 10 s) in order to affect the specific activity of ornithine decarboxylase (ODC) in L929 mouse cells. In this study we explore whether or not the superposition of an incoherent (noise) magnetic field can block the bioeffect of a coherent 60 Hz magnetic field, since the sum of the two fields is incoherent. An experimental test of this idea was conducted using as a biological marker the twofold enhancement of ODC activity found in L929 murine cells after exposure to a 60 Hz, 10 μTrms magnetic field. We superimposed an incoherent magnetic noise field, containing frequencies from 30 to 90 Hz, whose rms amplitude was comparable to that of the 60 Hz field. Under these conditions the ODC activity observed after exposure was equal to control levels. It is concluded that the superposition of incoherent magnetic fields can block the enhancement of ODC activity by a coherent magnetic field if the strength of the incoherent field is equal to or greater than that of the coherent field. When the superimposed, incoherent noise field was reduced in strength, the enhancement of ODC activity by the coherent field increased. Full ODC enhancement was obtained when the rms value of the applied EM noise was less than one-tenth that of the coherent field. These results are discussed in relation to the question of cellular detection of weak EM fields in the presence of endogenous thermal noise fields. © 1994 Wiley-Liss, Inc.  相似文献   

13.
Many in vitro experiments on the biological effects of extremely low frequency (ELF) electromagnetic fields utilize a uniform external magnetic flux density (B) to expose biological materials. A significant number of researchers do not measure or estimate the resulting electric field strength (E) or current density (J) in the sample medium. The magnitude and spatial distribution of the induced E field are highly dependent on the sample geometry and its relative orientation with respect to the magnetic field. We have studied the E fields induced in several of the most frequently used laboratory culture dishes and flasks under various exposure conditions. Measurements and calculations of the E field distributions in the aqueous sample volume in the containers were performed, and a set of simple, quantitative tables was developed. These tables allow a biological researcher to determine, in a straightforward fashion, the magnitudes and distributions of the electric fields that are induced in the aqueous sample when it is subjected to a uniform, sinusoidal magnetic field of known strength and frequency. In addition, we present a novel exposure technique based on a standard organ culture dish containing two circular, concentric annular rings. Exposure of the organ culture dish to a uniform magnetic field induces different average electric fields in the liquid medium in the inner and outer rings. Results of experiments with this system, which were reported in a separate paper, have shown the dominant role of the magnetically induced E field in producing specific biological effects on cells, in vitro. These results emphasize the need to report data about the induced E field in ELF in-vitro studies, involving magnetic field exposures. Our data tables on E and J in standard containers provide simple means to enable determination of these parameters.  相似文献   

14.
A teratological assessment was performed using rats that were exposed to an alternating magnetic field. The magnetic field had a sawtooth waveform similar to that produced by video display terminals (VDTs). Female rats were exposed 2 weeks prior to and throughout pregnancy at a rate of 7 h/day. Three intensities of magnetic field (5.7, 23 or 66 microT) were used. All of these field intensities were much greater than those to which VDT users are exposed. A slight but statistically significant decrease in maternal lymphocyte count for the highest intensity field was found as compared with the control group. However, the lymphocyte count was within the normal range, and the observed changes in hematological parameters were considered mild. No other maternal or fetal parameters that were examined showed a significant difference for any of the three field intensities. Where minor variations in skeleton development were observed they were known to be the common "noise" that appears in every teratological evaluation.  相似文献   

15.
Impact of pre-sowing exposure of seeds to static magnetic field were studied on 1 month old maize [Zea mays . var: HQPM.1] plants under field conditions. Pre-standardized magnetic field strength of 100 mT (2 h) and 200 mT (1 h), which were proven best for improving different seedling parameters under laboratory condition, were used for this study. Magnetic field treatment altered growth, superoxide radical level, antioxidant enzymes and photosynthesis. Among the different growth parameters, leaf area and root length were the most enhanced parameters (78–40%, respectively), over untreated plants. Electron paramagnetic resonance spectroscopy study showed that superoxide radical was reduced and hydroxyl radical was unaffected after magnetic field treatment. With decrease in free radical content, antioxidant enzymes like superoxide dismutase and peroxidase were also reduced by 43 and 23%, respectively, in plants that emerged from magnetically treated seeds. Measurement of Chlorophyll a fluorescence by plant efficiency analyzer showed that the potential of processing light energy through photosynthetic machinery was enhanced by magnetic field treatment. Performance index of the plant enhanced up to two-fold and phenomenological leaf model showed more active reaction centers after magnetic field treatment. Among the two field strengths used, 200 mT (1 h) was more effective in altering all these parameters. It is concluded that pre-sowing magnetic field treatment can be effectively used for improving plant growth and development under field conditions.  相似文献   

16.
Magnetic field sensors are used in various fields of technology. In the past few years a large variety of magnetic field sensors has been established and the performance of these sensors has been improved enormously. In this review article all recent developments in the area of sensitive magnetic field sensory analysis (resolution better than 1 nT) are presented and examined regarding their parameters. This is mainly done under the aspect of application fields in biomedical engineering. A comparison of all commercial and available sensitive magnetic field sensors shows current and prospective ranges of application.  相似文献   

17.
Intense uniform magnetic fields, such as those used in magnetic resonance imaging (MRI), are thought to exert little influence at the cellular level. Here we report modifications of the signaling cascades in rat cortical neurons cultured for 1 h in magnetic fields of up to 5 Tesla. The activation of c-Jun N-terminal kinase (JNK) increases monotonically with field strength, with a maximal activation of approximately 10% at 5 T, whereas the activation of extra cellular-regulated kinase (ERK) shows a maximum at 0.75 T ( approximately 10%). Since ERK is involved in cellular differentiation, these results indicate a magnetic induction of the signaling events associated with differentiation. However, the cells respond to further increases in field strength by evoking a stress response, since JNK is a stress-activated protein kinase. Three possible mechanisms are discussed and of these, the most plausible is magnetic field induced change in the membrane rest potential, a microscale magnetohydrodynamic effect. This mechanism most likely involves the activation of voltage dependent Ca(2+) channel opening; since intracellular Ca(2+) concentration was also found to be modified by the static magnetic field.  相似文献   

18.
MR-integrated radiotherapy requires suitable dosimetry detectors to be used in magnetic fields. This study investigates the feasibility of using dedicated MR-compatible ionization chambers at MR-integrated radiotherapy devices. MR-compatible ionization chambers (Exradin A19MR, A1SLMR, A26MR, A28MR) were precisely modeled and their relative response in a 6MV treatment beam in the presence of a magnetic field was simulated using EGSnrc. Monte Carlo simulations were carried out with the magnetic field in three orientations: the magnetic field aligned perpendicular to the chamber and beam axis (transverse orientation), the magnetic field parallel to the chamber as well as parallel to the beam axis. Monte Carlo simulation results were validated with measurements using an electromagnet with magnetic field strength upto 1.1 T with the chambers in transverse orientation. The measurements and simulation results were in good agreement, except for the A26MR ionization chamber in transverse orientation. The maximum increase in response of the ionization chambers observed was 8.6% for the transverse orientation. No appreciable change in chamber response due to the magnetic field was observed for the magnetic field parallel to the ionization chamber and parallel to the photon beam.Polarity and recombination correction factor were experimentally investigated in the transverse orientation. The polarity effect and recombination effect were not altered by a magnetic field.This study further investigates the response of the ionization chambers as a function of the chambers’ rotation around their longitudinal axis. A variation in response was observed when the chamber was not rotationally symmetric, which was independent of the magnetic field.  相似文献   

19.
The passage of a concentrated beam through the extraction system of a beam plasma generator is investigated on the basis of analysis of variations in the beam diameter and emittance. Evolution of these parameters is analyzed in the final section of the extraction device, which is characterized by the high density gradient of the supplied gas. Much attention is given to the influence of the magnetic field on the features of electron beam propagation. It is demonstrated that focusing is favorable to decreasing not only the beam transverse size, but also the growth rate of the beam emittance.  相似文献   

20.
We investigated the relative contributions of temperature and a 300 kHz alternating magnetic field (AMF) on magnetic hyperthermia treatment (MHT). Our system consisted of an induction coil, which generated AMF by electric current flow, and a newly developed, temperature‐controlled circulating water‐jacketed glass bottle placed inside the coil. The AMF generator operated at a frequency of 300 kHz with variable field strength ranging from 0 to 11 mT. Four treatment conditions were employed: (A) control (37 °C, 0 mT), (B) AMF exposure (37 °C, 11 mT), (C) hyperthermia (46 °C, 0 mT), and (D) hyperthermia plus AMF exposure (46 °C, 11 mT) for 30 min. Cell viability and apoptotic death rate were estimated. The relative contributions or interactions of hyperthermia (46 °C) and AMF (11 mT) on MHT were evaluated using 2 × 2 factorial experiment analysis. Group A was statistically different (P < 0.05) from each of the other treatments. The observed effects on both cell viability and apoptotic cell death were influenced by temperature (97.36% and 92.15%, respectively), AMF (1.78% and 4.99%, respectively), and the interactions between temperature and AMF (0.25% and 2.36%, respectively). Thus, the effect of hyperthermia was significant. Also, AMF exposure itself might play a role in MHT, although these observations were made in vitro. These findings suggest a possible presence of an AMF effect during clinical magnetic hyperthermia. Bioelectromagnetics 34:95–103, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏