首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Three benchtop high-throughput sequencing instruments are now available. The 454 GS Junior (Roche), MiSeq (Illumina) and Ion Torrent PGM (Life Technologies) are laser-printer sized and offer modest set-up and running costs. Each instrument can generate data required for a draft bacterial genome sequence in days, making them attractive for identifying and characterizing pathogens in the clinical setting. We compared the performance of these instruments by sequencing an isolate of Escherichia coli O104:H4, which caused an outbreak of food poisoning in Germany in 2011. The MiSeq had the highest throughput per run (1.6 Gb/run, 60 Mb/h) and lowest error rates. The 454 GS Junior generated the longest reads (up to 600 bases) and most contiguous assemblies but had the lowest throughput (70 Mb/run, 9 Mb/h). Run in 100-bp mode, the Ion Torrent PGM had the highest throughput (80–100 Mb/h). Unlike the MiSeq, the Ion Torrent PGM and 454 GS Junior both produced homopolymer-associated indel errors (1.5 and 0.38 errors per 100 bases, respectively).  相似文献   

2.

Background

Second-generation sequencers generate millions of relatively short, but error-prone, reads. These errors make sequence assembly and other downstream projects more challenging. Correcting these errors improves the quality of assemblies and projects which benefit from error-free reads.

Results

We have developed a general-purpose error corrector that corrects errors introduced by Illumina, Ion Torrent, and Roche 454 sequencing technologies and can be applied to single- or mixed-genome data. In addition to correcting substitution errors, we locate and correct insertion, deletion, and homopolymer errors while remaining sensitive to low coverage areas of sequencing projects. Using published data sets, we correct 94% of Illumina MiSeq errors, 88% of Ion Torrent PGM errors, 85% of Roche 454 GS Junior errors. Introduced errors are 20 to 70 times more rare than successfully corrected errors. Furthermore, we show that the quality of assemblies improves when reads are corrected by our software.

Conclusions

Pollux is highly effective at correcting errors across platforms, and is consistently able to perform as well or better than currently available error correction software. Pollux provides general-purpose error correction and may be used in applications with or without assembly.  相似文献   

3.

Background

Molecular genetic testing is recommended for diagnosis of inherited cardiac disease, to guide prognosis and treatment, but access is often limited by cost and availability. Recently introduced high-throughput bench-top DNA sequencing platforms have the potential to overcome these limitations.

Methodology/Principal Findings

We evaluated two next-generation sequencing (NGS) platforms for molecular diagnostics. The protein-coding regions of six genes associated with inherited arrhythmia syndromes were amplified from 15 human samples using parallelised multiplex PCR (Access Array, Fluidigm), and sequenced on the MiSeq (Illumina) and Ion Torrent PGM (Life Technologies). Overall, 97.9% of the target was sequenced adequately for variant calling on the MiSeq, and 96.8% on the Ion Torrent PGM. Regions missed tended to be of high GC-content, and most were problematic for both platforms. Variant calling was assessed using 107 variants detected using Sanger sequencing: within adequately sequenced regions, variant calling on both platforms was highly accurate (Sensitivity: MiSeq 100%, PGM 99.1%. Positive predictive value: MiSeq 95.9%, PGM 95.5%). At the time of the study the Ion Torrent PGM had a lower capital cost and individual runs were cheaper and faster. The MiSeq had a higher capacity (requiring fewer runs), with reduced hands-on time and simpler laboratory workflows. Both provide significant cost and time savings over conventional methods, even allowing for adjunct Sanger sequencing to validate findings and sequence exons missed by NGS.

Conclusions/Significance

MiSeq and Ion Torrent PGM both provide accurate variant detection as part of a PCR-based molecular diagnostic workflow, and provide alternative platforms for molecular diagnosis of inherited cardiac conditions. Though there were performance differences at this throughput, platforms differed primarily in terms of cost, scalability, protocol stability and ease of use. Compared with current molecular genetic diagnostic tests for inherited cardiac arrhythmias, these NGS approaches are faster, less expensive, and yet more comprehensive.  相似文献   

4.
The advent of next‐generation sequencing (NGS) technologies has transformed the way microsatellites are isolated for ecological and evolutionary investigations. Recent attempts to employ NGS for microsatellite discovery have used the 454, Illumina, and Ion Torrent platforms, but other methods including single‐molecule real‐time DNA sequencing (Pacific Biosciences or PacBio) remain viable alternatives. We outline a workflow from sequence quality control to microsatellite marker validation in three plant species using PacBio circular consensus sequencing (CCS). We then evaluate the performance of PacBio CCS in comparison with other NGS platforms for microsatellite isolation, through simulations that focus on variations in read length, read quantity and sequencing error rate. Although quality control of CCS reads reduced microsatellite yield by around 50%, hundreds of microsatellite loci that are expected to have improved conversion efficiency to functional markers were retrieved for each species. The simulations quantitatively validate the advantages of long reads and emphasize the detrimental effects of sequencing errors on NGS‐enabled microsatellite development. In view of the continuing improvement in read length on NGS platforms, sequence quality and the corresponding strategies of quality control will become the primary factors to consider for effective microsatellite isolation. Among current options, PacBio CCS may be optimal for rapid, small‐scale microsatellite development due to its flexibility in scaling sequencing effort, while platforms such as Illumina MiSeq will provide cost‐efficient solutions for multispecies microsatellite projects.  相似文献   

5.
Research in evolutionary biology involving nonmodel organisms is rapidly shifting from using traditional molecular markers such as mtDNA and microsatellites to higher throughput SNP genotyping methodologies to address questions in population genetics, phylogenetics and genetic mapping. Restriction site associated DNA sequencing (RAD sequencing or RADseq) has become an established method for SNP genotyping on Illumina sequencing platforms. Here, we developed a protocol and adapters for double‐digest RAD sequencing for Ion Torrent (Life Technologies; Ion Proton, Ion PGM) semiconductor sequencing. We sequenced thirteen genomic libraries of three different nonmodel vertebrate species on Ion Proton with PI chips: Arctic charr Salvelinus alpinus, European whitefish Coregonus lavaretus and common lizard Zootoca vivipara. This resulted in ~962 million single‐end reads overall and a mean of ~74 million reads per library. We filtered the genomic data using Stacks, a bioinformatic tool to process RAD sequencing data. On average, we obtained ~11 000 polymorphic loci per library of 6–30 individuals. We validate our new method by technical and biological replication, by reconstructing phylogenetic relationships, and using a hybrid genetic cross to track genomic variants. Finally, we discuss the differences between using the different sequencing platforms in the context of RAD sequencing, assessing possible advantages and disadvantages. We show that our protocol can be used for Ion semiconductor sequencing platforms for the rapid and cost‐effective generation of variable and reproducible genetic markers.  相似文献   

6.
Whole genome sequencing (WGS) shows great potential for real-time monitoring and identification of infectious disease outbreaks. However, rapid and reliable comparison of data generated in multiple laboratories and using multiple technologies is essential. So far studies have focused on using one technology because each technology has a systematic bias making integration of data generated from different platforms difficult. We developed two different procedures for identifying variable sites and inferring phylogenies in WGS data across multiple platforms. The methods were evaluated on three bacterial data sets and sequenced on three different platforms (Illumina, 454, Ion Torrent). We show that the methods are able to overcome the systematic biases caused by the sequencers and infer the expected phylogenies. It is concluded that the cause of the success of these new procedures is due to a validation of all informative sites that are included in the analysis. The procedures are available as web tools.  相似文献   

7.
Traditional Sanger sequencing as well as Next-Generation Sequencing have been used for the identification of disease causing mutations in human molecular research. The majority of currently available tools are developed for research and explorative purposes and often do not provide a complete, efficient, one-stop solution. As the focus of currently developed tools is mainly on NGS data analysis, no integrative solution for the analysis of Sanger data is provided and consequently a one-stop solution to analyze reads from both sequencing platforms is not available. We have therefore developed a new pipeline called MutAid to analyze and interpret raw sequencing data produced by Sanger or several NGS sequencing platforms. It performs format conversion, base calling, quality trimming, filtering, read mapping, variant calling, variant annotation and analysis of Sanger and NGS data under a single platform. It is capable of analyzing reads from multiple patients in a single run to create a list of potential disease causing base substitutions as well as insertions and deletions. MutAid has been developed for expert and non-expert users and supports four sequencing platforms including Sanger, Illumina, 454 and Ion Torrent. Furthermore, for NGS data analysis, five read mappers including BWA, TMAP, Bowtie, Bowtie2 and GSNAP and four variant callers including GATK-HaplotypeCaller, SAMTOOLS, Freebayes and VarScan2 pipelines are supported. MutAid is freely available at https://sourceforge.net/projects/mutaid.  相似文献   

8.
9.
High‐throughput sequencing methods have become a routine analysis tool in environmental sciences as well as in public and private sector. These methods provide vast amount of data, which need to be analysed in several steps. Although the bioinformatics may be applied using several public tools, many analytical pipelines allow too few options for the optimal analysis for more complicated or customized designs. Here, we introduce PipeCraft, a flexible and handy bioinformatics pipeline with a user‐friendly graphical interface that links several public tools for analysing amplicon sequencing data. Users are able to customize the pipeline by selecting the most suitable tools and options to process raw sequences from Illumina, Pacific Biosciences, Ion Torrent and Roche 454 sequencing platforms. We described the design and options of PipeCraft and evaluated its performance by analysing the data sets from three different sequencing platforms. We demonstrated that PipeCraft is able to process large data sets within 24 hr. The graphical user interface and the automated links between various bioinformatics tools enable easy customization of the workflow. All analytical steps and options are recorded in log files and are easily traceable.  相似文献   

10.
The emergence of next-generation sequencing (NGS) technologies has significantly improved sequencing throughput and reduced costs. However, the short read length, duplicate reads and massive volume of data make the data processing much more difficult and complicated than the first-generation sequencing technology. Although there are some software packages developed to assess the data quality, those packages either are not easily available to users or require bioinformatics skills and computer resources. Moreover, almost all the quality assessment software currently available didn’t taken into account the sequencing errors when dealing with the duplicate assessment in NGS data. Here, we present a new user-friendly quality assessment software package called BIGpre, which works for both Illumina and 454 platforms. BIGpre contains all the functions of other quality assessment software, such as the correlation between forward and reverse reads, read GC-content distribution, and base Ns quality. More importantly, BIGpre incorporates associated programs to detect and remove duplicate reads after taking sequencing errors into account and trimming low quality reads from raw data as well. BIGpre is primarily written in Perl and integrates graphical capability from the statistics package R. This package produces both tabular and graphical summaries of data quality for sequencing datasets from Illumina and 454 platforms. Processing hundreds of millions reads within minutes, this package provides immediate diagnostic information for user to manipulate sequencing data for downstream analyses. BIGpre is freely available at http://bigpre.sourceforge.net/.  相似文献   

11.
12.
Different second‐generation sequencing technologies may have taxon‐specific biases when DNA metabarcoding prey in predator faeces. Our major objective was to examine differences in prey recovery from bat guano across two different sequencing workflows using the same faecal DNA extracts. We compared results between the Ion Torrent PGM and the Illumina MiSeq with similar library preparations and the same analysis pipeline. We focus on repeatability and provide an R Notebook in an effort towards transparency for future methodological improvements. Full documentation of each step enhances the accessibility of our analysis pipeline. We tagged DNA from insectivorous bat faecal samples, targeted the arthropod cytochrome c oxidase I minibarcode region and sequenced the product on both second‐generation sequencing platforms. We developed an analysis pipeline with a high operational taxonomic unit (OTU) clustering threshold (i.e., ≥98.5%) followed by copy number filtering to avoid merging rare but genetically similar prey into the same OTUs. With this workflow, we detected 297 unique prey taxa, of which 74% were identified at the species level. Of these, 104 (35%) prey OTUs were detected by both platforms, 176 (59%) OTUs were detected by the Illumina MiSeq system only, and 17 (6%) OTUs were detected using the Ion Torrent system only. Costs were similar between platforms but the Illumina MiSeq recovered six times more reads and four additional insect orders than did Ion Torrent. The considerations we outline are particularly important for long‐term ecological monitoring; a more standardized approach will facilitate comparisons between studies and allow faster recognition of changes within ecological communities.  相似文献   

13.
高通量测序是DNA测序技术发展中的重大突破,它的出现为现代生物科学研究提供了前所未有的机遇,例如基于猎物和寄主植物DNA分子解析生态系统的食物网研究已逐渐成为捕食性动物与植食性动物食物网研究的新型模式。在简要总结Roche 454、Illumina和Ion Torrent为代表的第二代测序技术的原理及最新进展的基础上,综述了近年来利用高通量测序技术在捕食性和植食性动物食物网解析构建研究方面取得的最新进展及存在的问题,以期为探索捕食性和植食性动物的猎物/寄主范围、猎物/寄主转换、资源分配、生物防治、生物保护和生态恢复新方法提供思路和启发。  相似文献   

14.
DNA sequencing continues to decrease in cost with the Illumina HiSeq2000 generating up to 600 Gb of paired-end 100 base reads in a ten-day run. Here we present a protocol for community amplicon sequencing on the HiSeq2000 and MiSeq Illumina platforms, and apply that protocol to sequence 24 microbial communities from host-associated and free-living environments. A critical question as more sequencing platforms become available is whether biological conclusions derived on one platform are consistent with what would be derived on a different platform. We show that the protocol developed for these instruments successfully recaptures known biological results, and additionally that biological conclusions are consistent across sequencing platforms (the HiSeq2000 versus the MiSeq) and across the sequenced regions of amplicons.  相似文献   

15.
High-throughput sequencing of the taxonomically informative 16S rRNA gene provides a powerful approach for exploring microbial diversity. Here we compare the performances of two common “benchtop” sequencing platforms, Illumina MiSeq and Ion Torrent Personal Genome Machine (PGM), for bacterial community profiling by 16S rRNA (V1-V2) amplicon sequencing. We benchmarked performance by using a 20-organism mock bacterial community and a collection of primary human specimens. We observed comparatively higher error rates with the Ion Torrent platform and report a pattern of premature sequence truncation specific to semiconductor sequencing. Read truncation was dependent on both the directionality of sequencing and the target species, resulting in organism-specific biases in community profiles. We found that these sequencing artifacts could be minimized by using bidirectional amplicon sequencing and an optimized flow order on the Ion Torrent platform. Results of bacterial community profiling performed on the mock community and a collection of 18 human-derived microbiological specimens were generally in good agreement for both platforms; however, in some cases, results differed significantly. Disparities could be attributed to the failure to generate full-length reads for particular organisms on the Ion Torrent platform, organism-dependent differences in sequence error rates affecting classification of certain species, or some combination of these factors. This study demonstrates the potential for differential bias in bacterial community profiles resulting from the choice of sequencing platform alone.  相似文献   

16.
细菌耐药已成为威胁全球人类公共健康的重要因素之一,快速、准确明确细菌耐药的特性、机制及传播特征对疾病治疗及控制耐药菌的传播具有重要意义。高通量测序技术可以同时平行检测多个基因序列的状态,已广泛应用于细菌耐药检测。目前高通量测序技术在细菌耐药领域的应用主要有:全基因组测序技术、目标区域测序技术和宏基因组测序技术。所采用的测序平台主要为Illumina、Ion Torrent、BGI等二代测序和Pacific Biosciences、Oxford Nonopore 等三代测序平台。通过细菌耐药基因预测细菌耐药表型的准确性在很大程度上依赖于成熟的专业耐药基因数据库,各种通用型、特异型及隐马尔可夫模型耐药基因数据库的建立和完善,为高通量测序技术在细菌耐药领域的应用提供了坚实的基础。本文简要介绍了高通量测序技术、数据分析方法及相应测序平台在细菌耐药领域中的应用进展,并同时介绍了细菌耐药数据库的现状。  相似文献   

17.
DNA barcoding has become one of the most important techniques in plant species identification. Successful application of this technology is dependent on the availability of reference database of high species coverage. Unfortunately, there are experimental and data processing challenges to construct such a library within a short time. Here, we present our solutions to these challenges. We sequenced six conventional DNA barcode fragments (ITS1, ITS2, matK1, matK2, rbcL1, and rbcL2) of 380 flowering plants on next‐generation sequencing (NGS) platforms (Illumina Hiseq 2500 and Ion Torrent S5) and the Sanger sequencing platform. After comparing the sequencing depths, read lengths, base qualities, and base accuracies, we conclude that Illumina Hiseq2500 PE250 run is suitable for conventional DNA barcoding. We developed a new “Cotu” method to create consensus sequences from NGS reads for longer output sequences and more reliable bases than the other three methods. Step‐by‐step instructions to our method are provided. By using high‐throughput machines (PCR and NGS), labeling PCR, and the Cotu method, it is possible to significantly reduce the cost and labor investments for DNA barcoding. A regional or even global DNA barcoding reference library with high species coverage is likely to be constructed in a few years.  相似文献   

18.

Background

Influenza viruses exist as a large group of closely related viral genomes, also called quasispecies. The composition of this influenza viral quasispecies can be determined by an accurate and sensitive sequencing technique and data analysis pipeline. We compared the suitability of two benchtop next-generation sequencers for whole genome influenza A quasispecies analysis: the Illumina MiSeq sequencing-by-synthesis and the Ion Torrent PGM semiconductor sequencing technique.

Results

We first compared the accuracy and sensitivity of both sequencers using plasmid DNA and different ratios of wild type and mutant plasmid. Illumina MiSeq sequencing reads were one and a half times more accurate than those of the Ion Torrent PGM. The majority of sequencing errors were substitutions on the Illumina MiSeq and insertions and deletions, mostly in homopolymer regions, on the Ion Torrent PGM. To evaluate the suitability of the two techniques for determining the genome diversity of influenza A virus, we generated plasmid-derived PR8 virus and grew this virus in vitro. We also optimized an RT-PCR protocol to obtain uniform coverage of all eight genomic RNA segments. The sequencing reads obtained with both sequencers could successfully be assembled de novo into the segmented influenza virus genome. After mapping of the reads to the reference genome, we found that the detection limit for reliable recognition of variants in the viral genome required a frequency of 0.5% or higher. This threshold exceeds the background error rate resulting from the RT-PCR reaction and the sequencing method. Most of the variants in the PR8 virus genome were present in hemagglutinin, and these mutations were detected by both sequencers.

Conclusions

Our approach underlines the power and limitations of two commonly used next-generation sequencers for the analysis of influenza virus gene diversity. We conclude that the Illumina MiSeq platform is better suited for detecting variant sequences whereas the Ion Torrent PGM platform has a shorter turnaround time. The data analysis pipeline that we propose here will also help to standardize variant calling in small RNA genomes based on next-generation sequencing data.  相似文献   

19.
The fully annotated genome sequence of the European strain, 26695 was first published in 1997 and, in 1999, it was directly compared to the USA isolate J99, promoting two standard laboratory isolates for Helicobacter pylori (H. pylori) research. With the genomic scaffolds available from these important genomes and the advent of benchtop high-throughput sequencing technology, a bacterial genome can now be sequenced within a few days. We sequenced and analysed strains J99 and 26695 using the benchtop-sequencing machines Ion Torrent PGM and the Illumina MiSeq Nextera and Nextera XT methodologies. Using publically available algorithms, we analysed the raw data and interrogated both genomes by mapping the data and by de novo assembly. We compared the accuracy of the coding sequence assemblies to the originally published sequences. With the Ion Torrent PGM, we found an inherently high-error rate in the raw sequence data. Using the Illumina MiSeq, we found significantly more non-covered nucleotides when using the less expensive Illumina Nextera XT compared with the Illumina Nextera library creation method. We found the most accurate de novo assemblies using the Nextera technology, however, extracting an accurate multi-locus sequence type was inconsistent compared to the Ion Torrent PGM. We found the cagPAI failed to assemble onto a single contig in all technologies but was more accurate using the Nextera. Our results indicate the Illumina MiSeq Nextera method is the most accurate for de novo whole genome sequencing of H. pylori.  相似文献   

20.
Next generation sequencing (NGS) platforms are replacing traditional molecular biology protocols like cloning and Sanger sequencing. However, accuracy of NGS platforms has rarely been measured when quantifying relative frequencies of genotypes or taxa within populations. Here we developed a new bioinformatic pipeline (QRS) that pools similar sequence variants and estimates their frequencies in NGS data sets from populations or communities. We tested whether the estimated frequency of representative sequences, generated by 454 amplicon sequencing, differs significantly from that obtained by Sanger sequencing of cloned PCR products. This was performed by analysing sequence variation of the highly variable first internal transcribed spacer (ITS1) of the ichthyosporean Caullerya mesnili, a microparasite of cladocerans of the genus Daphnia. This analysis also serves as a case example of the usage of this pipeline to study within‐population variation. Additionally, a public Illumina data set was used to validate the pipeline on community‐level data. Overall, there was a good correspondence in absolute frequencies of C. mesnili ITS1 sequences obtained from Sanger and 454 platforms. Furthermore, analyses of molecular variance (amova ) revealed that population structure of Cmesnili differs across lakes and years independently of the sequencing platform. Our results support not only the usefulness of amplicon sequencing data for studies of within‐population structure but also the successful application of the QRS pipeline on Illumina‐generated data. The QRS pipeline is freely available together with its documentation under GNU Public Licence version 3 at http://code.google.com/p/quantification-representative-sequences .  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号