首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Strain-specific typing antisera (SSTA) were prepared for six inbred strains of rats by using a pooled immunization protocol. The SSTA were used in both a haemagglutination assay and a complement dependent microcytotoxicity assay to compare the usefulness of the two test systems. Both assays were simple, reliable and repeatable, and each system had distinct advantages and disadvantages. The haemagglutination assay was faster and required less specialized equipment than the microcytotoxicity assay. On the other hand, interpretation of results in the microcytotoxicity assay was easier and more objective. It was concluded that SSTA could be used with the microcytotoxicity assay and/or the haemagglutination assay to provide a simple and effective genetic monitoring method for inbred strain of rats.  相似文献   

2.
The hexokinase/glucose-6-phosphate dehydrogenase coupled enzyme system was used to assay for plant thioglucoside glucohydrolase (myrosinase, EC 3.2.3.1) by measuring the rate of glucose released during hydrolysis of glucosinolates. This coupled assay was compared with two other assays for myrosinase: a pH-stat assay that measures the rate of acid released during glucosinolate hydrolysis, and a spectrophotometric assay in which the decrease in the absorbance at 227.5 nm is used to measure the disappearance of the substrate, 2-propenylglucosinolate (DSA assay). The coupled and pH-stat assays were found to give comparable activities and were linear with enzyme concentration over the range 0 to 30 micrograms. The DSA assay gave lower myrosinase activity in comparison to the coupled and pH-stat assays. This is due to the lower concentrations of substrate and activator (ascorbate) which must be used in the assay. The DSA assay was found to give a nonlinear relationship with enzyme concentration over the range 2 to 30 micrograms. For these reasons this assay was found to be unsatisfactory. The coupled assay was found to be more sensitive and more widely applicable than the pH-stat assay as a routine continuous assay for myrosinase activity.  相似文献   

3.
We performed a real-time PCR assay to detect herpes simplex virus (HSV) DNA, and compared it prospectively with a nested PCR assay in 164 clinical samples (109 cerebrospinal fluid and 55 sera) from patients suspected of having neonatal HSV infection or HSV encephalitis. In 25 of 164 samples, HSV DNA was detected by the nested PCR assay. All samples positive for HSV DNA in the nested PCR assay were also positive in the real-time PCR assay, and all but two samples negative for HSV DNA in the nested assay were negative in the real-time assay. The real-time PCR assay thus had a sensitivity of 100% and a specificity of 99%, when compared with the nested assay. Sequential assays in a case of disseminated HSV showed that a decrease in HSV DNA paralleled clinical improvement. Quantification of HSV DNA by real-time PCR was useful for diagnosing and monitoring patients with HSV encephalitis and neonatal HSV infection.  相似文献   

4.
A real time quantitative PCR assay has been developed for detecting minute virus of mice (MVM). This assay directly quantifies PCR product by monitoring the increase of fluorescence intensity emitted during enzymatic hydrolysis of an oligonucleotide probe labelled covalently with fluorescent reporting and quenching dyes via Taq polymerase 5'-->3' exonuclease activity. The quantity of MVM DNA molecules in the samples was determined using a known amount of MVM standard control DNA fragment cloned into a plasmid (pCR-MVM). We have demonstrated that MVM TaqMan PCR assay is approximately 1000-fold more sensitive than the microplate infectivity assay with the lowest detection limit of approximately one particle per reaction. The reliable detection range is within 100 to 10(9) molecules per reaction with high reproducibility. The intra assay variation is <2.5%, and the inter assays variation is <6.5% when samples contain >100 particles/assay. When we applied the TaqMan PCR to MVM clearance studies done by column chromatography or normal flow viral filtration, we found that the virus removal factors were similar to that of virus infectivity assay. It takes about a day to complete entire assay processes, thus, the TaqMan PCR assay is at least 10-fold faster than the infectivity assay. Therefore, we concluded that this fast, specific, sensitive, and robust assay could replace the infectivity assay for virus clearance evaluation.  相似文献   

5.
The Microscreen assay was developed as a means of testing very small samples, as in complex mixture fractionation. It is a multi-endpoint assay which utilizes E. coli WP2s(lambda). Exposure takes place to serial dilutions of the test compound in microtitre wells (250 microliters) followed by sampling from wells in which growth has occurred ('non-toxic wells'). Although a number of different endpoints can be measured, only the prophage induction endpoint (the first one developed) has been extensively tested. Results with 133 compounds are presented. These include 111 compounds which have been tested in the S. typhimurium assay and 66 compounds for which both rodent bioassay and S. typhimurium assay data exists. The concordance for the Microscreen assay and the S. typhimurium assay was 71%. For this group of compounds, the sensitivity of the Microscreen assay in detecting carcinogens was 76% compared with 58% for the S. typhimurium assay. However, the S. typhimurium assay was somewhat more specific (69%) compared with the Microscreen (56%). The overall association between carcinogenicity and Microscreen results was statistically significant (p = 0.029), whereas for the S. typhimurium assay the association with carcinogenicity was non-significant (p = 0.086). The Microscreen assay was able to detect halogenated compounds better than the S. typhimurium assay. The Microscreen assay should prove useful in complex mixture fractionation, or in other situations where sample size is limiting.  相似文献   

6.
High-throughput screening (HTS) has grown rapidly in the past decade, with many advances in new assay formats, detection technologies, and laboratory automation. Recently, several studies have shown that the choice of assay technology used for the screening process is particularly important and can yield quite different primary screening outcomes. However, because the screening assays in these previous studies were performed in a single-point determination, it is not clear to what extent the difference observed in the screening results between different assay technologies is attributable to inherent assay variability and day-to-day measurement variation. To address this question, a nuclear receptor coactivator recruitment assay was carried out in 2 different assay formats, namely, AlphaScreen and time-resolved fluorescence resonance energy transfer, which probed the same biochemical binding events but with different detection technologies. For each assay format, 4 independent screening runs in a typical HTS setting were completed to evaluate the run-to-run screening variability. These multiple tests with 2 assay formats allow an unambiguous comparison between the discrepancies of different assay formats and the effects of the variability of assay and screening measurements on the screening outcomes. The results provide further support that the choice of assay format or technology is a critical factor in HTS assay development.  相似文献   

7.
Many assay technologies currently exist to develop high-throughput screening assays, and the number of choices continues to increase. Results from a previous study comparing assay technologies in our laboratory do not support the common assumption that the same hits would be found regardless of which assay technology is used. To extend this investigation, a nuclear receptor antagonist assay was developed using 3 assay formats: AlphaScreen, time-resolved fluorescence (TRF), and time-resolved fluorescence resonance energy transfer (TR-FRET). Compounds ( approximately 42000) from the Novartis library were evaluated in all 3 assay formats. A total of 128 compounds were evaluated in dose-response experiments, and 109 compounds were confirmed active from all 3 formats. The AlphaScreen, TRF, and TR-FRET assay technologies identified 104, 23, and 57 active compounds, respectively, with only 18 compounds active in all 3 assay formats. A total of 128 compounds were evaluated in a cell-based functional assay, and 35 compounds demonstrated activity in this cellular assay. Furthermore, 34, 11, and 16 hits that were originally identified in the dose-response experiment by AlphaScreen, TRF, and TR-FRET assay technologies, respectively, were functionally active. The results of the study indicated that AlphaScreen identified the greatest number of functional antagonists.  相似文献   

8.
A forward and a reverse mutation assay designed to detect environmental mutagens have been compared in Salmonella typhimurium. The forward mutation assay scored resistance to L-arabinose and the reverse assay, reversion of histidine auxotrophy. Eighteen chemicals of different structural groups, all known to be mutagenic in the histidine reverse assay, were applied to strains carrying the genetic markers needed to perform both mutation assays. The mutagenicity of each chemical was determined by both plate and liquid tests. The plate test counted absolute numbers of surviving mutants and the liquid test separately measured survival and frequency of mutants among the survivors. All the chemicals used were found to be mutagenic in both mutation assays. The response of the L-arabinose assay was equal to or larger than the response of the histidine assay in the case of 16 chemicals. The two other compounds, 2-nitrofluorene and sodium azide, were detected more efficiently by the histidine assay. Sodium azide, a non-carcinogenic compound, is a potent mutagen in the histidine assay, but very weak in the L-arabinose assay.  相似文献   

9.
The Fc function of immunoglobulins is commonly determined by an assay based on monitoring immunoglobulin induced, complement mediated red cell lysis. This assay requires a continuous source of fresh red cells. We have shown that the assay can be successfully performed with frozen red cells. The possibility of access to a stored standard stock of red cells will improve the convenience of performing the assay and could contribute to improved assay reproducibility.  相似文献   

10.
We describe here a double-layer plaque assay for the quantification of enteroviruses, combining a monolayer plaque assay and a suspended-cell plaque assay. The double-layer assay provides significantly greater counts than other methods of virus quantification of both suspensions of pure culture viruses and naturally occurring viruses. The counts obtained by this method are approximately one order of magnitude greater than those obtained with the more commonly used method, the monolayer plaque assay. We conclude that the methods available for quantifying viruses rank in efficiency as follows: double-layer plaque assay >or=suspended-cell plaque assay > counting cytopathogenic virus adsorbed to cellulose nitrate membrane filters >or= most probable number of cytopathogenic units > monolayer plaque assay. Moreover, the double-layer plaque assay allows the use of two different cell lines in the two layers. Using the human colonic carcinoma cell line CaCo2 facilitates the recovery of a greater number and diversity of naturally occurring enteroviruses in water than the monolayer agar method. In addition, the pretreatment of cells with 5-iodo-2'-deoxyuridine (IDU) prior to the quantification of enteroviruses by the double-layer plaque assay provides significantly higher recoveries than the use of IDU does with the other methods of quantification.  相似文献   

11.
Leukotriene A4 (LTA4) hydrolase catalyzes a rate-limiting final biosynthetic step of leukotriene B4 (LTB4), a potent lipid chemotactic agent and proinflammatory mediator. LTB4 has been implicated in the pathogenesis of various acute and chronic inflammatory diseases, and thus LTA4 hydrolase is regarded as an attractive therapeutic target for anti-inflammation. To facilitate identification and optimization of LTA4 hydrolase inhibitors, a specific and efficient assay to quantify LTB4 is essential. This article describes the development of a novel 384-well homogeneous time-resolved fluorescence assay for LTB4 (LTB4 HTRF assay) and its application to establish an HTRF-based LTA4 hydrolase assay for lead optimization. This LTB4 HTRF assay is based on competitive inhibition and was established by optimizing the reagent concentration, buffer composition, incubation time, and assay miniaturization. The optimized assay is sensitive, selective, and robust, with a Z' factor of 0.89 and a subnanomolar detection limit for LTB4. By coupling this LTB4 HTRF assay to the LTA4 hydrolase reaction, an HTRF-based LTA4 hydrolase assay was established and validated. Using a test set of 16 LTA4 hydrolase inhibitors, a good correlation was found between the IC50 values obtained using LTB4 HTRF with those determined using the LTB enzyme-linked immunoassay (R = 0.84). The HTRF-based LTA4 hydrolase assay was shown to be an efficient and suitable assay for determining compound potency and library screening to guide the development of potent inhibitors of LTA4 hydrolase.  相似文献   

12.
E. coli has been widely used as a host system to manufacture recombinant proteins for human therapeutic use. Among impurities to be eliminated during the downstream process, residual host cell DNA is a major interest for safety. Residual E. coli host cell DNA in the final products are usually determined using conventional slot blot hybridization assay or total DNA Threshold assay, although these methods are time consuming, expensive, and relatively insensitive. Therefore a sensitive real-time PCR assay for specific detection of residual E. coli DNA was developed and compared with slot blot hybridization assay and Threshold assay to validate the overall capability of these methods. Specific primer pair for amplification of the E. coli 16S rRNA gene was selected to improve the sensitivity, and E. coli host cell DNA was quantified by use of SYBR Green 1. The detection limit of real-time PCR assay in the optimized condition was calculated to be 0.042 pg genomic DNA, which is much higher than those of slot blot hybridization assay and Threshold assay of which detection limit were 2.42 and 3.73 pg genomic DNA, respectively. The real-time PCR assay was validated to be more reproducible, accurate, and precise than slot blot hybridization assay and Threshold assay. The real-time PCR assay may be a useful tool for quantitative detection and clearance validation of residual E. coli DNA during the manufacturing process for recombinant therapeutics.  相似文献   

13.
An on-line assay for a thermostable pullulanase and antithrombin III (AT III) is described. The assay is based on the formation of aggregates between the protein to be measured and antibodies raised against this protein. Assay automation was achieved by utilizing the flow injection analysis (FIA) principles. The apparatus, a stopped-flow, merging-zone manifold, is described in detail. Since the reaction used in an FIA system does not have to reach equilibrium, it was possible to reduce the time for an assay cycle to 2.5 min. A method for simulating cultivation conditions was developed for assay optimization. Using this method, a detection limit of I mg l−1 together with a standard deviation of 1.5 was found. A sandwich ELISA was used as reference assay in the case of AT III and an enzymatic activity assay in the case of pullulanase. Correlation coefficients of 0.988 (AT III) and 0.976 (pullulanase) were determined. The turbidimetric assay was successfully used for pullulanase monitoring during a 240-h cultivation of Clostridium thermosulfurogenes.  相似文献   

14.
15.
Results of a complete survey of the more than 2-million-member Pharmacopeia compound collection in a 1536-well microvolume screening assay format are reported. A complete technology platform, enabling the performance of ultra-high throughput screening in a miniaturized 1536-well assay format, has been assembled and utilized. The platform consists of tools for performing microvolume assays, including assay plates, liquid handlers, optical imagers, and data management software. A fluorogenic screening assay for inhibition of a protease enzyme target was designed and developed using this platform. The assay was used to perform a survey screen of the Pharmacopeia compound collection for active inhibitors of the target enzyme. The results from the survey demonstrate the successful implementation of the ultra-high throughout platform for routine screening purposes. Performance of the assay in the miniaturized format is equivalent to that of a standard 96-well assay, showing the same dependence on kinetic parameters and ability to measure enzyme inhibition. The survey screen identified an active class of compounds within the Pharmacopeia compound collection. These results were confirmed using a standard 96-well assay.  相似文献   

16.
目的:建立一种检测马尔尼菲青霉菌的实时荧光定量PCR的方法。方法:针对马尔尼菲青霉菌5.8S rRNA设计特异性PCR引物,采用核酸荧光染料SYBR GreenⅠ进行实时荧光定量PCR检测,探讨该方法的灵敏度和特异性,并进行临床样品检测验证。结果:该方法的特异性较好,与该菌属内的其他细菌间无交叉反应;灵敏度可检测出10个细胞/mL全血,在检测范围内线性良好,相关系数R2=0.981。临床样品检测和传统的培养方法结果完全相符。结论:该方法特异性好,灵敏度高,操作简单,检测时间短;临床样品检测具有很好的准确性,从本研究的结果显示实时荧光定量PCR方法在检测马尔尼菲青霉菌中的应用可以大大缩短临床的诊断时间,提高临床诊断的准确度和效率。  相似文献   

17.
Loop-mediated isothermal amplification (LAMP) assay detected Salmonella within 60 min. The 220 strains of 39 serotypes of Salmonella subsp. enterica and 7 strains of Salmonella enterica subsp. arizonae were amplified, but not 62 strains of 23 bacterial species other than Salmonella. The sensitivity of the LAMP assay was found to be >2.2 cfu/test tube using nine serotypes. The specificity was similar to that of a PCR assay, but the sensitivity of LAMP was greater. Both fluorescence and turbidity were able to detect the products in the LAMP assay. S. enteritidis in a liquid egg sample artificially inoculated with the organism was detected by the LAMP assay at 2.8 cfu/test tube, although negative by PCR assay. These results indicate that the LAMP assay is a rapid, specific and sensitive detection method for Salmonella.  相似文献   

18.
In recent years there has been a sharp increase in publications concerned with adherence of bacteria to animal cells. Surprisingly, the three types of assays used to measure such adherence — light microscopy, quantitative subculture and radiolabel assays — had not previously been compared in a systematic fashion to determine their reliability or relative merits. In the present report we undertake such a comparison. Our findings indicate that although each assay has unique advantages and limitations, the double radiolabel assay has the fewest major limitations of the three assays examined. Unfortunately, this assay can quantitative the number of bacteria adhering to a given number of cells, but not the actual percent of cells colonized. The microscopic assay, because of its subjectivity and inability to detect small or poorly staining microorganisms, or to differentiate morphologically similar bacteria in mixed populations, is the least useful of the adherence assays. Our data suggest that when this assay is used, no fewer than 50 cells should be examined. The quantitative subculture assay had the advantage of detecting living bacterial forms, but suffered from difficulty obtaining a homogeneous suspension of colonized cells. Our data suggest that when using this assay or the radiolabel assay, quantitation of both bacterial and animal cells is necessary even when using only confluent monolayers. To obtain a comprehensive picture of bacterial adherence, data obtained with one assay should be confirmed in at least one of the other two assay systems.  相似文献   

19.
20.
The statistics of estimators used with the endpoint assay for virus titration were investigated. For a standard assay with 10 wells/dilution, the graphical estimator traditionally used was found to produce estimates with significant positive bias and a relatively low accuracy. Furthermore, the graphical estimator was found to be inconsistent. A superior estimator based on the maximum likelihood principle was developed. The results are discussed in relation to the choice between the endpoint titration assay and the plaque assay, and an alternative two-stage assay is presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号