首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Precise microwave heating has emerged as a valuable method to aid solid‐phase peptide synthesis (SPPS). New methods and reliable protocols, as well as their embodiment in automated instruments, are required to fully use this potential. Here we describe a new automated robotic instrument for SPPS with microwave heating, report protocols for its reliable use and report the application to the synthesis of long sequences, including the β‐amyloid 1‐42 peptide. The instrument is built around a valve‐free robot originally developed for parallel peptide synthesis, where the robotic arm transports reagents instead of pumping reagents via valves. This is the first example of an ‘X‐Y’ robotic microwave‐assisted synthesizer developed for the assembly of long peptides. Although the instrument maintains its capability for parallel synthesis at room temperature, in this paper, we focus on sequential peptide synthesis with microwave heating. With this valve‐free instrument and the protocols developed for its use, fast and efficient syntheses of long and difficult peptide sequences were achieved. Copyright © 2010 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

2.
Benzotriazole‐based coupling reagents have dominated the last two decades of solid phase peptide synthesis. However, a growing interest in synthesizing complex peptides has stimulated the search for more efficient and low‐cost coupling reagents, such as COMU which has been introduced as a nonexplosive alternative to the classic benzotriazole coupling reagents. Here, we present a comparative study of the coupling efficiency of COMU with the benzotriazole‐based HBTU and HCTU for use in in situ neutralization Boc‐SPPS. Difficult sequences, such as ACP(65–74), Jung–Redeman 10‐mer, and HIV‐1 PR(81–99), were used as model target peptides on polystyrene‐based resins, as well as polyethylene glycol‐based resins. Coupling yields obtained using fast in situ Boc‐SPPS cycles were determined with the quantitative ninhydrin test as well as via LC‐MS analysis of the crude cleavage products. Our results demonstrate that COMU coupling efficiency was less effective compared to HBTU and HCTU with HCTU ≥ HBTU > COMU, when polystyrene‐based resins were employed. However, when the PEG resin was employed in combination with a safety catch amide (SCAL) linker, more comparable yields were observed for the three coupling reagents with the same ranking HCTU ≥ HBTU > COMU. Copyright © 2012 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

3.
A series of six novel opioid peptide analogs containing one to three N‐methylamino acid residues, and six cyclic counterparts of these peptides were prepared by the solid‐phase method. Introduction of two consecutive N‐methylated amino acids, as well as cyclization of such conformationally constrained sequences, turned out to be challenging. The use of a recently reported triazine‐based coupling reagent, 4‐(4,6‐dimethoxy‐1,3,5‐triazin‐2‐yl)‐4‐methylmorpholinium toluene‐4‐sulfonate, enabled the synthesis and cyclization of the designed analogs in acceptable yields and with a lesser amount of by‐products than observed with the standard coupling reagents such as TBTU or HATU.Copyright © 2015 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

4.
Structural modification of the peptide backbone via N‐methylation is a powerful tool to modulate the pharmacokinetic profile and biological activity of peptides. Here we describe a rapid and highly efficient microwave(MW)‐assisted Fmoc/tBu solid‐phase method to prepare short chain N‐methyl‐rich peptides, using Rink amide p‐methylbenzhydrylamine (MBHA) resin as solid‐phase support. This method produces peptides in high yield and purity, and reduces the time required for Fmoc‐N‐methyl amino acid coupling. Copyright © 2010 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

5.
Phosphonium and uronium salt‐based reagents enable efficient and effective coupling reactions and are indispensable in peptide chemistry, especially in machine‐assisted SPPS. However, after the activating and coupling steps with these reagents in the presence of tertiary amines, Fmoc derivatives of Cys are known to be considerably racemized during their incorporation. To avoid this side reaction, a coupling method mediated by phosphonium/uronium reagents with a weaker base, such as 2,4,6‐trimethylpyridine, than the ordinarily used DIEA or that by carbodiimide has been recommended. However, these methods are appreciably inferior to the standard protocol applied for SPPS, that is, a 1 min preactivation procedure of coupling with phosphonium or uronium reagents/DIEA in DMF, in terms of coupling efficiency, and also the former method cannot reduce racemization of Cys(Trt) to an acceptable level (<1.0%) even when the preactivation procedure is omitted. Here, the 4,4′‐dimethoxydiphenylmethyl and 4‐methoxybenzyloxymethyl groups were demonstrated to be acid‐labile S‐protecting groups that can suppress racemization of Cys to an acceptable level (<1.0%) when the respective Fmoc derivatives are incorporated via the standard SPPS protocol of phosphonium or uronium reagents with the aid of DIEA in DMF. Furthermore, these protecting groups significantly reduced the rate of racemization compared to the Trt group even in the case of microwave‐assisted SPPS performed at a high temperature. © 2013 The Authors. European Peptide Society published by John Wiley & Sons, Ltd.  相似文献   

6.
A core‐shell type polymer support for solid‐phase peptide synthesis has been developed for high coupling efficiency of peptides and versatile applications such as on‐bead bioassays. Although various kinds of polymer supports have been developed, they have their own drawbacks including poor accessibility of reagents and incompatibility in aqueous solution. In this paper, we prepared hydrophilic tri(ethylene glycol) (TEG) grafted core‐shell type polymer supports (TEG SURE) for efficient solid‐phase peptide synthesis and on‐bead bioassays. TEG SURE was prepared by grafting TEG derivative on the surface of AM PS resin via biphasic diffusion control method and subsequent acetylation of amine groups which are located at the core region of AM PS resin. The performance of TEG SURE was evaluated by synthesizing several peptides. Three points can be highlighted: (1) easy control of loading level of TEG, (2) improved efficiency of peptide synthesis compared with the conventional resins, and (3) applicability of on‐bead bioassays.  相似文献   

7.
The methodology for peptide bond formation is undergoing a continuous evolution where the main actors are being renewed. In recent years, coupling reagents based on the Oxyma scaffold, such as the uronium salt COMU, has been a groundbreaking contribution to the field. The advantages of COMU over classic benzotriazole‐based reagents (HATU, HBTU, HCTU, TBTU) were proven in terms of solubility and coupling efficiency in bulky junctions in our groups and others. However, some aspects of the use of COMU need to be revised and improved, such as the stability of commercial samples in organic solvents, which hampers the compatibility with long synthesis in automated synthesizers. In this review, an overview of the main features and suggestions to improve the use of COMU are presented, along with a discussion on the best conditions for its use in microwave‐assisted peptide robots. Copyright © 2013 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

8.
The application of microwave irradiation to solid-phase peptide synthesis increases product purity and reduces reaction time. Parallel synthesis in 96-well polypropylene filter plates with microwave irradiation is an efficient method for the rapid generation of combinatorial peptide libraries in sufficient purity to assay the products directly for biological activity without HPLC purification. In this protocol, the solid-phase support is arrayed into each well of a 96-well plate, reagents are delivered using a multichannel pipette and a microwave reactor is used to complete peptide coupling reactions in 6 min and Fmoc-removal reactions in 4 min under temperature-controlled conditions. The microwave-assisted parallel peptide synthesis protocol has been used to generate a library of difficult hexa-beta-peptides in 61% average initial purity (50% yield) and has been applied to the preparation of longer alpha- and beta-peptides. Using this protocol, a library of 96 different hexapeptides can be synthesized in 24 h (excluding characterization).  相似文献   

9.
Evaluating the stability of coupling reagents, quality control (QC), and surface functionalization metrology are all critical to the production of high quality peptide microarrays. We describe a broadly applicable screening technique for evaluating the fidelity of solid phase peptide synthesis (SPPS), the stability of activation/coupling reagents, and a microarray surface metrology tool. This technique was used to assess the stability of the activation reagent 1‐{[1‐(Cyano‐2‐ethoxy‐2‐oxo‐ethylidenaminooxy)dimethylamino‐morpholinomethylene]}methaneaminiumHexafluorophosphate (COMU) (Sigma‐Aldrich, St. Louis, MO, USA) by SPPS of Leu‐Enkephalin (YGGFL) or the coupling of commercially synthesized YGGFL peptides to (3‐aminopropyl)triethyoxysilane‐modified glass surfaces. Coupling efficiency was quantitated by fluorescence signaling based on immunoreactivity of the YGGFL motif. It was concluded that COMU solutions should be prepared fresh and used within 5 h when stored at ~23 °C and not beyond 24 h if stored refrigerated, both in closed containers. Caveats to gauging COMU stability by absorption spectroscopy are discussed. Commercial YGGFL peptides needed independent QC, due to immunoreactivity variations for the same sequence synthesized by different vendors. This technique is useful in evaluating the stability of other activation/coupling reagents besides COMU and as a metrology tool for SPPS and peptide microarrays. Copyright © 2015 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

10.
We have been engaged in the microwave‐solid phase peptide synthesis (SPPS) synthesis of the phenylglycine (Phg)‐containing pentapeptide H‐Ala‐Val‐Pro‐Phg‐Tyr‐NH2 (1) previously demonstrated to bind to the so‐called BIR3 domain of the anti‐apoptotic protein XIAP. Analysis of the target peptide by a combination of RP‐HPLC, ESI‐MS, and NMR revealed the presence of two diastereoisomers arising out of the racemisation of the Phg residue, with the percentage of the LLLDL component assessed as 49%. We performed the synthesis of peptide (1) using different microwave and conventional stepwise SPPS conditions in attempts to reduce the level of racemisation of the Phg residue and to determine at which part of the synthetic cycle the epimerization had occurred. We determined that racemisation occurred mainly during the Fmoc‐group removal and, to a much lesser extent, during activation/coupling of the Fmoc‐Phg‐OH residue. We were able to obtain the desired peptide with a 71% diastereomeric purity (29% LLLDL as impurity) by utilizing microwave‐assisted SPPS at 50 °C and power 22 Watts, when the triazine‐derived coupling reagent DMTMM‐BF4 was used, together with NMM as an activator base, for the incorporation of this residue and 20% piperidine as an Fmoc‐deprotection base. In contrast, the phenylalanine analogue of the above peptide, H‐Ala‐Val‐Pro‐Phe‐Tyr‐NH2 (2), was always obtained as a single diastereoisomer by using a range of standard coupling and deprotection conditions. Our findings suggest that the racemisation of Fmoc‐Phg‐OH, under both microwave‐SPPS and stepwise conventional SPPS syntheses conditions, is very facile but can be limited through the use of the above stated conditions. Copyright © 2012 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

11.
Microwave energy represents an efficient manner to accelerate both the deprotection and coupling reactions in 9-fluorenylmethyloxycarbonyl (Fmoc) solid phase peptide synthesis (SPPS). Typical SPPS side reactions including racemization and aspartimide formation can occur with microwave energy but can easily be controlled by routine use of optimized methods. Cysteine, histidine, and aspartic acid were susceptible to racemization during microwave SPPS of a model 20mer peptide containing all 20 natural amino acids. Lowering the microwave coupling temperature from 80 degrees C to 50 degrees C limited racemization of histidine and cysteine. Additionally, coupling of both histidine and cysteine can be performed conventionally while the rest of the peptide is synthesized using microwave without any deleterious effect, as racemization during the coupling reaction was limited to the activated ester state of the amino acids up to 80 degrees C. Use of the hindered amine, collidine, in the coupling reaction also minimized formation of D-cysteine. Aspartimide formation and subsequent racemization of aspartic acid was reduced by the addition of HOBt to the deprotection solution and/or use of piperazine in place of piperidine.  相似文献   

12.
A series of fluorescein phosphoramidites (FAM) have been synthesized for use on automated DNA synthesizers. After coupling of the FAM reagents to the 5' hydroxyl of the oligonucleotide on the DNA synthesizer, the excess reagent is removed by washing the solid support. The dye, and its linkage to the oligonucleotide, are stable during the conditions of DNA synthesis and cleavage/deprotection conditions. Purification is attained with the OPC (Oligonucleotide Purification Cartridge), a polystyrene based affinity matrix, which selectively retains hydrophobic oligonucleotide conjugates. Analysis by MicroGel capillary electrophoresis effectively separates fluorescent dye labelled oligonucleotides from unlabelled products.  相似文献   

13.
Microwave‐assisted (MW) reactions are of special interest to the chemical community due to faster reaction times, cleaner reactions and higher product yields. The adaptation of MW to solid phase peptide synthesis resulted in spectacular syntheses of difficult peptides. In the case of Merrifield support, used frequently in synthesis of special peptides, the conditions used in product cleavage are not compatible with off‐resin monitoring of the reaction progress. The application of MW irradiation in product removal from Merrifield resin using trifluoroacetic acid (TFA) was investigated using model tetrapeptides and the effects were compared with standard trifluoromethanesulphonic acid (TFMSA) cleavage using elemental analysis as well as chromatographic (HPLC) and spectroscopic (IR) methods. The deprotection of benzyloxycarbonyl and benzyl groups in synthetic bioactive peptides was analyzed using LC‐MS and MS/MS experiments. In a 5 min microwave‐assisted TFA reaction at low temperature, the majority of product is released from the resin, making the analytical scale MW‐assisted procedure a method of choice in monitoring the reactions carried out on Merrifield resin due to the short reaction time and compatibility with HPLC and ESI‐MS conditions. Copyright © 2009 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

14.
Tan YD  Fu YX 《Genetics》2007,175(2):923-931
Although most high-density linkage maps have been constructed from codominant markers such as single-nucleotide polymorphisms (SNPs) and microsatellites due to their high linkage information, dominant markers can be expected to be even more significant as proteomic technique becomes widely applicable to generate protein polymorphism data from large samples. However, for dominant markers, two possible linkage phases between a pair of markers complicate the estimation of recombination fractions between markers and consequently the construction of linkage maps. The low linkage information of the repulsion phase and high linkage information of coupling phase have led geneticists to construct two separate but related linkage maps. To circumvent this problem, we proposed a new method for estimating the recombination fraction between markers, which greatly improves the accuracy of estimation through distinction between the coupling phase and the repulsion phase of the linked loci. The results obtained from both real and simulated F2 dominant marker data indicate that the recombination fractions estimated by the new method contain a large amount of linkage information for constructing a complete linkage map. In addition, the new method is also applicable to data with mixed types of markers (dominant and codominant) with unknown linkage phase.  相似文献   

15.
We synthesized new chiral fluorescence labeling reagents having a 2,3-anthracenedicarboximide group from D-glucosamine, and it was possible to introduce target alcohols at the anomeric positions of the reagents with beta-selectivity by glycosidations. Especially, it was possible to use methyl glycoside reagent as a glycosyl donor with a Lewis acid and microwave irradiation, and it gave selectively beta-glycoside while the reaction without microwave irradiation gave alpha- and beta-mixed glycosides. Those reagents showed very high chiral discrimination ability, and they made it possible to separate the eight stereoisomers of 4,8,12,16-tetramethylheptadecanol by HPLC after derivatizations.  相似文献   

16.
A rapid and efficient microwave-assisted solid-phase synthesis method is described for the preparation of the nonapeptide WDTVRISFK, using conventional Fmoc/Bu(t) orthogonal protection strategy. The synthesis protocol is based on the use of cycles of pulsed microwave irradiation with intermittent cooling of the reaction during the removal of the Fmoc protecting group and during the coupling. The desired nonapeptide was obtained in highest yield and purity by employing MicroKan technology. The chemical reactions were carried out in a single-mode microwave reactor, equipped with a fiber-optic probe to monitor the reaction temperature continuously.  相似文献   

17.
Enzymes on carriers can be easily recycled or used in fixed bed reactors. The immobilization often results in an improved stability. Depending on the support used and the method of coupling, this is a time‐consuming process. While the wide applicability of microwaves (MWs) within organic synthesis is known since the 1980s, proteins (including enzymes) are generally considered as too sensitive toward MW irradiation. In this article, MW methods were investigated to improve the processing speed of covalent enzyme immobilization on inorganic supports. Herein two laccases from Trametes versicolor and Myceliophthora thermophilia (Novozyme 51003®) and the glucose oxidase from Aspergillus niger were immobilized onto samples of ceramic honeycomb and porous glass (TRISOPERL® 1000 AMINO). The enzymes showed different sensitivity to MW irradiation, but all were suitable for MW‐assisted immobilization. Subsequent stability tests were conducted to compare conventional immobilization methods with those with MW irradiation. The glucose oxidase provided the best results. For all cases, a successful MW irradiation assisted covalent enzyme immobilization on solid support was obtained with a total 20‐fold reduction of the time necessary.  相似文献   

18.
Nucleosides can be esterified to solid-phase supports using uronium or phosphonium coupling reagents and a coupling additive, such as 1-hydroxybenzotriazole (HOBT), 7-aza-1-hydroxybenzotriazole (HOAT), N-methylimidazole (NMI), or 4-(dimethylamino)pyridine (DMAP). However, DMAP was far superior to other additives and high nucleoside loadings (up to 60 micromol/g) and rapid coupling reactions (< or = 10 min) were possible. Hydroxyl-derivatized CPG was attached to nucleosides with 3'-succinyl or 3'-hydroquinone-O, O'-diacetic acid (HQDA or Q-Linker) carboxyl groups through a primary ester linkage. Alternatively, supports derivatized with succinic acid or the Q-Linker were attached directly to the 3'-OH group of nucleosides through a secondary ester linkage. Uronium reagents (HATU or HBTU) gave the best results with the HQDA linker arm, while the bromophosphonium (BrOP or PyBrOP) reagents were best with the succinyl linker arm. In all cases, the coupling reactions were much faster than previous methods using carbodiimide coupling reagents. The ease and speed of the reaction make this support derivatization procedure suitable for automated in situ couplings on DNA synthesizers.  相似文献   

19.
Solid phase peptide synthesis requires large amounts of organic solvents, the safe disposal of which is an important environmental issue. Peptide synthesis, if performed in water and using less or nontoxic reagents, circumvents the disposal problem. Our ultimate aim is to develop an "environment-friendly" solid phase peptide synthesis (SPPS) methodology. Previously, we showed that SPPS in water is feasible. To perform SPPS in water, the coupling reagent must be water-soluble and maintain its reactivity in water. For this report, we tested the efficacy of the water-soluble coupling reagents, 2-(5-norbornene-2,3-dicarboximido)-1,1,3,3-tetramethyluronium tetrafluoroborate (TNTU) and 4-(4,6-dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride (DMT-MM), towards SPPS in water. We successfully synthesized Leu-enkephalin amide on a solid support suspended in aqueous 50% EtOH using DMT-MM and 2-(4-sulfophenylsulfonyl)ethoxycarbonylamino acids.  相似文献   

20.
In this study, we synthesized a polypeptide from its pentapeptide unit using microwave irradiation. Effective methods for polypeptide synthesis from unit peptides have not been reported. Here, we used a key elastin peptide, H‐GlyValGlyValPro‐OH (GVGVP), as the monomer peptide. It is difficult to obtain poly(Gly‐Val‐Gly‐Val‐Pro) (poly(GVGVP)) from the pentapeptide unit of elastin, GVGVP, via polycondensation. Poly(GVGVP) prepared from genetically recombinant Escherichia coli is a well‐known temperature‐sensitive polypeptide, and this temperature sensitivity is known as the lower critical solution temperature. When microwave irradiation was performed in the presence of various additives, the pentapeptide (GVGVP) polycondensation reaction proceeded smoothly, resulting in a product with a high molecular weight in a relatively good yield. The reaction conditions, like microwave irradiation, coupling agents, and solvents, were optimized to increase the reaction efficiency. The product exhibited a molecular weight greater than Mr 7000. Further, the product could be synthesized on a gram scale. The synthesized polypeptide exhibited a temperature sensitivity that was similar to that of poly(GVGVP) prepared from genetically recombinant E. coli. Therefore, this technique offers a facile and quick approach to prepare polypeptides in large amounts. Copyright © 2016 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号