首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Accurate mechanics measurements during high-frequency oscillatory ventilation (HFOV) facilitate optimizing ventilator support settings. Yet, these are influenced substantially by endotracheal tube (ETT) contributions, which may dominate when leaks around uncuffed ETT are present. We hypothesized that 1) the effective removal of ETT leaks may be confirmed via direct comparison of measured vs. model-predicted mean intratracheal pressure [mPtr (meas) vs. mPtr (pred)], and 2) reproducible respiratory system resistance (Rrs) and compliance (Crs) may be derived from no-leak oscillatory Ptr and proximal flow. With the use of ETT test-lung models, proximal airway opening (Pao) and distal (Ptr) pressures and flows were measured during slow-cuff inflations until leaks are removed. These were repeated for combinations of HFOV settings [frequency, mean airway pressure (Paw), oscillation amplitudes (ΔP), and inspiratory time (%t(I))] and varying test-lung Crs. Results showed that leaks around the ETT will 1) systematically reduce the effective distending pressures and lung-delivered oscillatory volumes, and 2) derived mechanical properties are increasingly nonphysiologic as leaks worsen. Mean pressures were systematically reduced along the ventilator circuit and ETT (Paw > Pao > Ptr), even for no-leak conditions. ETT size-specific regression models were then derived for predicting mPtr based on mean Pao (mPao), ΔP, %t(I), and frequency. Next, in 10 of 11 studied preterm infants (0.77 ± 0.24 kg), no-to-minimal leak was confirmed based on excellent agreement between mPtr (meas) and mPtr (pred), and consequently, their oscillatory respiratory mechanics were evaluated. Infant resistance at the proximal ETT (R(ETT); resistance airway opening = R(ETT) + Rrs; P < 0.001) and ETT inertance (P = 0.014) increased significantly with increasing ΔP (50%, 100%, and 150% baseline), whereas Rrs showed a modest, nonsignificant increase (P = 0.14), and Crs was essentially unchanged (P = 0.39). We conclude that verifying no-leak conditions is feasible by comparison of model-derived vs. distending mPtr (meas). This facilitated the reliable and accurate assessment of physiologic respiratory mechanical properties that can objectively guide ventilatory management of HFOV-treated preterm infants.  相似文献   

2.
Effect of body posture on respiratory impedance   总被引:1,自引:0,他引:1  
The effects of posture on the mechanics of the respiratory system are not well known, particularly in terms of total respiratory resistance. We have measured respiratory impedance (Zrs) by the forced random noise excitation technique in the sitting and the supine position in 24 healthy subjects. Spirometry and lung volumes (He-dilution technique) were also measured in both postures. The equivalent resistance (Rrs), compliance (Crs), and inertance (Irs) were also calculated by fitting each measured Zrs to a linear series model. When subjects changed from sitting to the supine position, the real part of Zrs increased over the whole frequency band. The associated equivalent resistance, Rrs, increased by 28.2%. The reactance decreased for frequencies lower than 18 Hz and increased for higher frequencies. Consequently, Crs decreased by 38.7% and Irs increased by 15.6%. All of these parameter differences were significant (P less than 0.001). A covariance analysis showed that a significant amount of the postural change in Rrs and Crs can be explained by the reduction of functional residual capacity (FRC). This indicates that the observed differences on Zrs can in part be explained be a shift of the operating point of the respiratory system induced by the decrease in the FRC.  相似文献   

3.
In the current study, we hypothesize that senescent-dependent changes between airway and lung parenchymal tissues of C57BL/6J (B6) mice are not synchronized with respect to altered lung mechanics. Furthermore, aging modifications in elastin fiber and collagen content of the airways and lung parenchyma are remodeling events that differ with time. To test these hypotheses, we performed quasi-static pressure-volume (PV) curves and impedance measurements of the respiratory system in 2-, 20-, and 26-mo-old B6 mice. From the PV curves, the lung volume at 30 cmH(2)O pressure (V(30)) and respiratory system compliance (Crs) were significantly (P < 0.01) increased between 2 and 20 mo of age, representing about 80-84% of the total increase that occurred between 2 and 26 mo of age. Senescent-dependent changes in tissue damping and tissue elastance were analogous to changes in V(30) and Crs; that is, a majority of the parenchymal alterations in the lung mechanics occurred between 2 and 20 mo of age. In contrast, significant decreases in airway resistance (R) occurred between 20 and 26 mo of age; that is, the decrease in R between 2 and 20 mo of age represented only 29% (P > 0.05) of total decrease occurring through 26 mo. Morphometric analysis of the elastic fiber content in lung parenchyma was significantly (P < 0.01) decreased between 2 and 20 mo of age. To the contrary, increased collagen content was significantly delayed until 26 mo of age (P < 0.01, 2 vs. 26 mo). In conclusion, our data demonstrate that senescent-dependent changes in airway and lung tissue mechanics are not synchronized in B6 mice. Moreover, the reduction in elastic fiber content with age is an early lung remodeling event, and the increased collagen content in the lung parenchyma occurs later in senescence.  相似文献   

4.
Maturation of the respiratory pattern and the active and passive mechanical properties of the respiratory system were assessed in 19 tracheotomized rabbits (postnatal age range: 1-26 days) placed in a body plethysmograph. With maturation both minute ventilation and tidal volume significantly increased, whereas respiratory frequency decreased. When normalized for body weight (kg) both the passive (Rrs X kg) and active (R'rs X kg) resistances of the respiratory system significantly increased with age, whereas the corresponding passive (Crs X kg-1) and active (C'rs X kg-1) compliances significantly decreased. At any given age R'rs X kg only slightly exceeded Rrs X kg, whereas C'rs X kg-1 was significantly lower than Crs X kg-1. Moreover, the maturational increases in Rrs X kg and R'rs X kg exceeded the corresponding decreases in Crs X kg-1 and C'rs X kg-1, resulting in significant age-related increases in both the passive (tau rs) and active (tau'rs) time constants of the respiratory system. Due to the age-related increases in tau'rs, producing a delayed volume response to any given inspiratory driving pressure, the relative volume loss obtained at any time during inspiration was greater in the maturing rabbit. On the other hand, because of concomitant compensatory changes in respiratory pattern, evidenced by increases in inspiratory duration with age, the end-inspiratory tidal volume loss in the maturing animal was maintained generally less than 10% at all postnatal ages. Thus maturational changes in respiratory pattern appear coupled to changes in the active mechanical properties of the respiratory system. The latter coupling serves to optimize the transduction of inspiratory pressure into volume change in a manner consistent with establishing the minimum inspiratory work of breathing during postnatal development.  相似文献   

5.
Our aim was to measure the compliance of the liquid-filled lungs (CL), and the compliance of the chest wall (CW) in fetal sheep in utero. CL and CW were measured in 6 fetuses. The compliance of the lungs and chest wall combined (respiratory system, Crs) was measured in 9 fetuses. Pressure differences across the lungs (PL), chest wall (PW) and respiratory system (Prs) were measured while the lungs were deflated and inflated with liquid from their resting lung liquid volume (V1). V1 was measured using an indicator dilution technique. Specific compliance values were obtained by normalizing the values of CL, CW and Crs with respect to values of V1. From values obtained during stepwise inflation from V1, specific compliances (ml/cm H2O/ml of lung liquid) were: lungs, 0.22 +/- 0.02; chest wall, 0.41 +/- 0.07; respiratory system, 0.13 +/- 0.01. Specific compliances of the lungs, chest wall and respiratory system did not change significantly with advancing gestational age from 120 to 143 days. Our baseline data will be valuable in assessing the in utero progress of the structural development of the lungs following manipulations known to cause altered lung growth.  相似文献   

6.
This study was designed to determine the responses of lung volume and respiratory resistance (Rrs) to decreasing levels of continuous negative airway pressure (CNAP). Twenty normal subjects were studied in the basal state and under CNAP levels of -5, -10, and -15 hPa. Rrs was measured by the forced oscillation technique (4-32 Hz). End-expiratory lung volume (EELV) and tidal volume (VT) were measured by whole body plethysmography. Rrs was extrapolated to 0 Hz (R(0)) and estimated at 16 Hz (R(16)) by linear regression analysis of Rrs vs. frequency. Specific Rrs, SR(0) and SR(16), were then calculated as R(0) (EELV + VT/2) and R(16) (EELV + VT/2), respectively. EELV significantly decreased, whereas R(0), R(16), SR(0), and SR(16) significantly increased, as the CNAP level decreased (P < 0.0001 for all). At the lowest CNAP level, R(0) and R(16) reached 198 +/- 13 and 175 +/- 9% of their respective basal values. The CNAP-induced increase in R(0) was significantly higher than that in R(16) (P < 0.004). Our results demonstrate that the CNAP-induced increase in Rrs does not result from a direct lung volume effect only and strongly suggest the involvement of other factors affecting both intrathoracic and extrathoracic airway caliber.  相似文献   

7.
The frequency dependence of respiratory impedance (Zrs) from 0.125 to 4 Hz (Hantos et al., J. Appl. Physiol. 60: 123-132, 1986) may reflect inhomogeneous parallel time constants or the inherent viscoelastic properties of the respiratory tissues. However, studies on the lung alone or chest wall alone indicate that their impedance features are also dependent on the tidal volumes (VT) of the forced oscillations. The goals of this study were 1) to identify how total Zrs at lower frequencies measured with random noise (RN) compared with that measure with larger VT, 2) to identify how Zrs measured with RN is affected by bronchoconstriction, and 3) to identify the impact of using linear models for analyzing such data. We measured Zrs in six healthy dogs by use of a RN technique from 0.125 to 4 Hz or with a ventilator from 0.125 to 0.75 Hz with VT from 50 to 250 ml. Then methacholine was administered and the RN was repeated. Two linear models were fit to each separate set of data. Both models assume uniform airways leading to viscoelastic tissues. For healthy dogs, the respiratory resistance (Rrs) decreased with frequency, with most of the decrease occurring from 0.125 to 0.375 Hz. Significant VT dependence of Rrs was seen only at these lower frequencies, with Rrs higher as VT decreased. The respiratory compliance (Crs) was dependent on VT in a similar fashion at all frequencies, with Crs decreasing as VT decreased. Both linear models fit the data well at all VT, but the viscoelastic parameters of each model were very sensitive to VT. After methacholine, the minimum Rrs increased as did the total drop with frequency. Nevertheless the same models fit the data well, and both the airways and tissue parameters were altered after methacholine. We conclude that inferences based only on low-frequency Zrs data are problematic because of the effects of VT on such data (and subsequent linear modeling of it) and the apparent inability of such data to differentiate parallel inhomogeneities from normal viscoelastic properties of the respiratory tissues.  相似文献   

8.
In patients with adult respiratory distress syndrome (ARDS) we studied the effect of positive end-expiratory pressure (PEEP) on respiratory mechanics. We used the technique of rapid airway occlusion during constant flow (V) inflation to partition the total respiratory system resistance (Rrs) into the interrupter resistance (Rint,rs) and the additional resistance (delta Rrs) due to viscoelastic pressure dissipations and time constant inequalities. We also measured static (Est,rs) and dynamic (Edyn,rs) elastance of the respiratory system. The procedure was carried out in nine ARDS patients at different inspiratory V and inflation volumes (delta V) at PEEP of 0, 5, 10, and 15 cmH2O. We found that during baseline ventilation (delta V = 0.7 liter and V = 1 l/s), Est,rs, Edyn,rs, and Rint,rs did not change significantly with PEEP, whereas delta Rrs and Rrs increased significantly only with PEEP of 15 cmH2O. The increase of delta Rrs and Rrs with PEEP was positively correlated with the concomitant changes in end-expiratory lung volume (P < 0.001). At all levels of PEEP, under iso-delta V conditions, delta Rrs decreased with increasing V, whereas at a fixed V, delta Rrs increased with increasing delta V. A four-parameter model of the respiratory system failed to fully describe respiratory dynamics in the ARDS patients, probably due to nonlinearities.  相似文献   

9.
In order to estimate optimum parameters for artificial ventilation of adult guinea pigs, the effect of four hours intermittent positive pressure ventilation (IPPV) was studied using different tidal volumes (VT), respiratory frequencies (f), and minute volumes (Ve). Total compliance was measured by placing the animal in a whole body plathysmograph, the arterial blood gases, pH and base excess by catheterizing the carotid artery. In Series I 9 guinea pigs were ventilated at parameters adapted to the spontaneous breathing pattern (VT = 2 ml, f = 70 breaths.min-1). This ventilatory pattern resulted in severe disorders in compliance, gas exchange, and acid-base balance. In Series II 3 different VT (2, 6, 10 ml) were studied by changing f so that Ve was kept constant. The results demonstrated a favourable effect of slow and deep ventilation upon lung mechanics and oxygenation. In Series III 3 different Ve (300, 250, 200 ml.min-1) were tested using a constant VT = 10 ml. Optimum parameters for artificial ventilation of adult guinea pigs were: VT = 10 ml and f = 20 breath--min-1 which resulted in stable compliance, good O2-saturation, normocapnia and normal acid-base balance.  相似文献   

10.
Forced oscillatory impedance of the respiratory system at low frequencies   总被引:6,自引:0,他引:6  
Respiratory mechanical impedances were determined during voluntary apnea in five healthy subjects, by means of 0.25- to 5-Hz pseudo/random oscillations applied at the mouth. The total respiratory impedance was partitioned into pulmonary (ZL) and chest wall components with the esophageal balloon technique; corrections were made for the upper airway shunt impedance and the compressibility of alveolar gas. Neglect of these shunt effects did not qualitatively alter the frequency dependence of impedances but led to underestimations in impedance, especially in the chest wall resistance (Rw), which decreased by 20-30% at higher frequencies. The total resistance (Rrs) was markedly frequency dependent, falling from 0.47 +/- 0.06 (SD) at 0.25 Hz to 0.17 +/- 0.01 at 1 Hz and 0.15 +/- 0.01 kPa X l-1 X s at 5 Hz. The changes in Rrs were caused by the frequency dependence of Rw almost exclusively between 0.25 and 2 Hz and in most part between 2 and 5 Hz. The effective total respiratory (Crs,e) and pulmonary compliance were computed with corrections for pulmonary inertance derived from three- and five-parameter model fittings of ZL. Crs,e decreased from the static value (1.03 +/- 0.18 l X kPa-1) to a level of approximately 0.35 l X kPa-1 at 2-3 Hz; this change was primarily caused by the frequency-dependent behavior of chest wall compliance.  相似文献   

11.
Airway function is largely preserved during exercise or isocapnic hyperventilation in humans and guinea pigs despite likely changes in airway milieu during hyperpnea. It is only on cessation of a hyperpneic challenge that airway function deteriorates significantly. We tested the hypothesis that nitric oxide, a known bronchodilator that is produced in the lungs and bronchi, might be responsible for the relative bronchodilation observed during hyperventilation (HV) in guinea pigs. Three groups of anesthetized guinea pigs were given saline and three groups given 50 mg/kg N(G)-monomethyl-L-arginine (L-NMMA), a potent nitric oxide synthase inhibitor. Three isocapnic ventilation groups included normal ventilation [40 breaths/min, 6 ml/kg tidal volume (VT)], increased respiratory rate only (150 breaths/min, 6 ml/kg VT), and increased respiratory rate and increased volume (100 breaths/min, 8 ml/kg VT). L-NMMA reduced expired nitric oxide in all groups. Expired nitric oxide was slightly but significantly increased by HV in the saline groups. However, inhibition of nitric oxide production had no significant effect on rate of rise of respiratory system resistance (Rrs) during HV or on the larger rise in Rrs seen 6 min after HV. We conclude that nitric oxide synthase inhibition has no effect on changes in Rrs, either during or after HV in guinea pigs.  相似文献   

12.
13.
Vagal denervation performed in the intrathoracic region in newborn lambs leads to hypoxemia and decreased respiratory system compliance (Crs), which could result from atelectasis and/or pulmonary edema. The objective of the present study was to quantify the relative roles of alveolar derecruitment and pulmonary edema as underlying cause(s) of respiratory failure. Vagal denervation was performed in the intrathoracic region and below the recurrent laryngeal nerves in six newborn lambs within 24 h of birth, whereas six were sham operated. Pre- and postinflation Crs was measured to investigate the presence of alveolar derecruitment. Pulmonary edema was assessed with lung wet-dry-to-wet and lung tissue wet-to-dry ratios, total protein, and FITC-BSA recovery in lung tissue and bronchoalveolar lavage. Compared with that in the sham-operated animals, Crs was significantly lower in vagally denervated animals. However, postinflation, pulmonary system compliance obtained by quasi-static lung inflation and deflation to 30 cmH2O showed no significant difference between the sham-operated and denervated lambs. The lung wet-dry-to-wet and lung tissue wet-to-dry ratios, total protein, and FITC-BSA recovery in lung tissue and bronchoalveolar lavage were similar in denervated and sham-operated groups. We provide evidence that reduced lung volume and not pulmonary edema is associated with intrathoracic vagal denervation and is the likely underlying mechanism for hypoxemia and low Crs.  相似文献   

14.
Recent studies have suggested a close association between total respiratory compliance (Crs) and tidal volume in anesthetized paralyzed infants who are being artificially ventilated. To investigate this further, the multiple occlusion technique was used to measure Crs in 20 anesthetized infants and young children (aged 1-25 mo) before elective surgery. Measurements were made after intubation 1) during spontaneous breathing (SB), 2) after administration of a non-depolarizing muscle relaxant with tidal volume and frequency mimicking that during SB, and 3) with the child still paralyzed but tidal volume approximately double that during SB. Compared with values obtained during SB, there was no significant change in Crs after paralysis when ventilation matched the child's own pattern (P greater than 0.2). When ventilated with the larger tidal volumes, the infants showed a highly significant increase in Crs (mean 62%, range 14-158%, P less than 0.0001). These results may have implications not only for studies performed during anesthesia but also when infants were monitored in the intensive care setting. Values of Crs obtained in ventilated infants may reflect both the mechanical behavior of the respiratory system and the pattern of ventilation at the time of measurement.  相似文献   

15.
Total respiratory system compliance (Crs) at volumes above the tidal volume (VT) was studied by use of the expiratory volume clamping (EVC) technique in 10 healthy sleeping unsedated newborn infants. Flow was measured with a pneumotachograph attached to a face mask and integrated to yield volume. Volume changes were confirmed by respiratory inductance plethysmography. Crs measured by EVC was compared with Crs during tidal breathing determined by the passive flow-volume (PFV) technique. Volume increases of approximately 75% VT were achieved with three to eight inspiratory efforts during expiratory occlusions. Crs above VT was consistently greater than during tidal breathing (P less than 0.0005). This increase in Crs likely reflects recruitment of lung units that are closed or atelectatic in the VT range. Within the VT range, Crs measured by PFV was compared with that obtained by the multiple-occlusion method (MO). PFV yielded greater values of Crs than MO (P less than 0.01). This may be due to braking of expiratory airflow after the release of an occlusion or nonlinearity of Crs. Thus both volume recruitment and airflow retardation may affect the measurement of Crs in unsedated newborn infants.  相似文献   

16.
In dogs, respiratory system resistance (Rrs) is frequency independent, and during high-frequency oscillatory ventilation (HFO) the relationship between CO2 elimination (VCO2) and frequency is linear. In contrast, we found in rabbits a large frequency-dependent decrease in Rrs with increasing frequency along with a nonlinear relationship between frequency and VCO2 (J. Appl. Physiol. 57: 354-359, 1984). We proposed that frequency dependent mechanical properties of the lung account for inter-species differences in the frequency dependence of gas exchange during HFO. In the current study we tested this hypothesis further by measuring VCO2 and Rrs as a function of frequency in a species of monkey (Macaca radiata). In these monkeys, Rrs decreased minimally between 4 and 8 Hz and in general increased at higher frequencies, whereas VCO2 was linearly related to frequency. This is further evidence supporting the hypothesis that nonlinear frequency-VCO2 behavior during HFO is related to frequency-dependent behavior in Rrs.  相似文献   

17.
To determine whetherinitial lung volume optimization influences respiratory mechanics,which could indicate the achievement of optimal volume, we studied 17 premature infants with respiratory distress syndrome (RDS) assisted byhigh-frequency oscillatory ventilation. The continuous distendingpressure (CDP) was increased stepwise from 6-8 cmH2Oup to optimal CDP (OCDP), i.e., that allowing good oxygenation with thelowest inspired O2 fraction. Respiratory systemcompliance (Crs) and resistance were concomitantlymeasured. Mean OCDP was 16.5 ± 1.2 cmH2O. InspiredO2 fraction could be reduced from an initial level of 0.73 ± 0.17 to 0.33 ± 0.07. However, Crs (0.45 ± 0.14ml · cmH2O1 · kg1at starting CDP point) remained unchanged through lung volume optimization but appeared inversely related to OCDP. Similarly, respiratory system resistance was not affected. We conclude that thereis a marked dissociation between oxygenation improvement and Crsprofile during the initial phase of lung recruitment by earlyhigh-frequency oscillatory ventilation in infants with RDS. Thusoptimal lung volume cannot be defined by serial Crs measurement. At themost, low initial Crs suggests that higher CDP will be needed.

  相似文献   

18.
We evaluated the role of endothelin-1 (ET-1) and the involvement of nitric oxide in cardiovascular and respiratory dysfunction, during endotoxic shock, in 18 anaesthetised, mechanically ventilated pigs, divided into three groups. Group 1 was i.v. infused with LPS (20 microg/Kg/h for 240 min). Group 2 was pre-treated with bosentan, a dual inhibitor of ET-1 receptors, and at 180 min of endotoxic shock, L-NAME (N(G)-nitro-L-arginine methyl ester, 10 mg/Kg), a non-selective inhibitor of NO synthases, was i.v. administered. Group 3 was infused with LPS and L-NAME was administered similarly to group 2. Results show that LPS caused systemic hypotension, pulmonary biphasic hypertension, decrease in compliance (C(rs)) and increase in resistance (R(max,rs)) of respiratory system. Bosentan completely abolished the pulmonary hypertension and the changes in C(rs)and R(max,rs). L-NAME does not affect the LPS-dependent changes in respiratory mechanics, but it worsens the cardiovascular effects, causing death of pigs. Pre-treatment with bosentan prevents this deleterious effect.Our study demonstrates that the LPS-dependent respiratory effects are mediated by ET-1, which, probably causing pulmonary oedema, is responsible for the decrease in C(rs)and the increase of R(max,rs).  相似文献   

19.
Airway function deteriorates significantly on cessation of exercise or isocapnic hyperventilation challenges but is largely preserved during the challenge in humans and guinea pigs. PGE(2), an endogenous bronchodilator, might be responsible for the preservation of lung function during hyperventilation (HV). We hypothesized that PGE(2) might have a protective effect during HV, partially explaining the minimal changes in respiratory system resistance (Rrs) usually seen during HV in humans and guinea pigs. Therefore, changes in Rrs were measured during and after HV in anesthetized, mechanically ventilated guinea pigs treated with flurbiprofen (FBN) or placebo. With HV, there was an initial bronchodilation that was unaffected by FBN. Rrs then increased with time during HV, an effect that was blocked by FBN. After HV, Rrs increased further in all groups, but the increase in Rrs was less in the FBN-treated groups. FBN treatment reduced the PGE(2) concentration slightly in lung lavage fluid compared with placebo. We found no enhancement or refractoriness of the Rrs response to repeat bouts of HV and no effect of FBN treatment on the response of Rrs to repeat HV. These results suggest that a constrictor PG is released during and possibly after HV and that the post-HV increase in Rrs is the sum of effects of the PG released during HV and a second constrictor mechanism operating after HV. We found no evidence for bronchodilator PG during or after HV in the guinea pig.  相似文献   

20.
Lung mechanics and airway responsiveness to methacholine (MCh) were studied in seven volunteers before and after a 20-min intravenous infusion of saline. Data were compared with those of a time point-matched control study. The following parameters were measured: 1-s forced expiratory volume, forced vital capacity, flows at 40% of control forced vital capacity on maximal (Vm(40)) and partial (Vp(40)) forced expiratory maneuvers, lung volumes, lung elastic recoil, lung resistance (Rl), dynamic elastance (Edyn), and within-breath resistance of respiratory system (Rrs). Rl and Edyn were measured during tidal breathing before and for 2 min after a deep inhalation and also at different lung volumes above and below functional residual capacity. Rrs was measured at functional residual capacity and at total lung capacity. Before MCh, saline infusion caused significant decrements of forced expiratory volume in 1 s, Vm(40), and Vp(40), but insignificantly affected lung volumes, elastic recoil, Rl, Edyn, and Rrs at any lung volume. Furthermore, saline infusion was associated with an increased response to MCh, which was not associated with significant changes in the ratio of Vm(40) to Vp(40). In conclusion, mild airflow obstruction and enhanced airway responsiveness were observed after saline, but this was not apparently due to altered elastic properties of the lung or inability of the airways to dilate with deep inhalation. It is speculated that it was likely the result of airway wall edema encroaching on the bronchial lumen.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号