首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
X-ray imaging offers a new 3-D view into cells. With its ability to penetrate whole hydrated cells it is ideally suited for pairing fluorescence light microscopy and nanoscale X-ray tomography. In this paper, we describe the X-ray optical set-up and the design of the cryo full-field transmission X-ray microscope (TXM) at the electron storage ring BESSY II. Compared to previous TXM set-ups with zone plate condenser monochromator, the new X-ray optical layout employs an undulator source, a spherical grating monochromator and an elliptically shaped glass capillary mirror as condenser. This set-up improves the spectral resolution by an order of magnitude. Furthermore, the partially coherent object illumination improves the contrast transfer of the microscope compared to incoherent conditions. With the new TXM, cells grown on flat support grids can be tilted perpendicular to the optical axis without any geometrical restrictions by the previously required pinhole for the zone plate monochromator close to the sample plane. We also developed an incorporated fluorescence light microscope which permits to record fluorescence, bright field and DIC images of cryogenic cells inside the TXM. For TXM tomography, imaging with multi-keV X-rays is a straightforward approach to increase the depth of focus. Under these conditions phase contrast imaging is necessary. For soft X-rays with shrinking depth of focus towards 10nm spatial resolution, thin optical sections through a thick specimen might be obtained by deconvolution X-ray microscopy. As alternative 3-D X-ray imaging techniques, the confocal cryo-STXM and the dual beam cryo-FIB/STXM with photoelectron detection are proposed.  相似文献   

2.
In vivo near-infrared fluorescence imaging   总被引:12,自引:0,他引:12  
Photon penetration into living tissue is highly dependent on the absorption and scattering properties of tissue components. The near-infrared region of the spectrum offers certain advantages for photon penetration, and both organic and inorganic fluorescence contrast agents are now available for chemical conjugation to targeting molecules. This review focuses on those parameters that affect image signal and background during in vivo imaging with near-infrared light and exogenous contrast agents. Recent examples of in vivo near-infrared fluorescence imaging of animals and humans are presented, including imaging of normal and diseased vasculature, tissue perfusion, protease activity, hydroxyapatite and cancer.  相似文献   

3.
Hard X-ray fluorescence microscopy is well-suited to in-situ investigations of trace metal distributions within whole, unstained, biological tissue, with sub-parts-per-million detection achievable in whole cells. The high penetration of X-rays indicates the use of X-ray fluorescence tomography for structural visualization, and recent measurements have realised sub-500-nm tomography on a 10-μm cell. Limitations of present approaches impact the duration of an experiment and imaging fidelity. Developments in X-ray resolution, detector speed, cryogenic environments, and the incorporation of auxiliary signals are being pursued within the synchrotron community. Several complementary approaches to X-ray fluorescence tomography will be routinely available to the biologist in the near future. We discuss these approaches and review applications of biological relevance.  相似文献   

4.
Synchrotron X-ray fluorescence microscopy (SXRF) is a microanalytical technique for the quantitative mapping of elemental distributions. Among currently available imaging modalities, SXRF is the only technique that is compatible with fully hydrated biological samples such as whole cells or tissue sections, while simultaneously offering trace element sensitivity and submicron spatial resolution. Combined with the ability to provide information regarding the oxidation state and coordination environment of metal cations, SXRF is ideally suited to study the intracellular distribution and speciation of trace elements, toxic heavy metals and therapeutic or diagnostic metal complexes.  相似文献   

5.
Characteristic X-ray fluorescence is a technique that can be used to establish elemental concentrations for a large number of different chemical elements simultaneously in different locations in cell and tissue samples. Exposing the samples to an X-ray beam is the basis of X-ray fluorescence microscopy (XFM). This technique provides the excellent trace element sensitivity; and, due to the large penetration depth of hard X-rays, an opportunity to image whole cells and quantify elements on a per cell basis. Moreover, because specimens prepared for XFM do not require sectioning, they can be investigated close to their natural, hydrated state with cryogenic approaches. Until several years ago, XFM was not widely available to bio-medical communities, and rarely offered resolution better then several microns. This has changed drastically with the development of third-generation synchrotrons. Recent examples of elemental imaging of cells and tissues show the maturation of XFM imaging technique into an elegant and informative way to gain insight into cellular processes. Future developments of XFM-building of new XFM facilities with higher resolution, higher sensitivity or higher throughput will further advance studies of native elemental makeup of cells and provide the biological community including the budding area of bionanotechnology with a tool perfectly suited to monitor the distribution of metals including nanovectors and measure the results of interactions between the nanovectors and living cells and tissues.  相似文献   

6.
One of the main challenges of modern biochemistry and cell biology is to be able to observe molecular dynamics in their functional context, i.e. in live cells in situ. Thus, being able to track ongoing molecular events with maximal spatial and temporal resolution (within subcellular compartments), while minimizing interference with tissue biology, is key to future developments for in situ imaging. The recent use of non-linear optics approaches in tissue microscopy, made possible in large part by the availability of femtosecond pulse lasers, has allowed major advances on this front that would not have been possible with conventional linear microscopy techniques. Of these approaches, the one that has generated most advances to date is two-photon laser scanning fluorescence microscopy. While this approach does not really provide improved resolution over linear microscopy in non absorbing media, it allows us to exploit a window of low absorbance in live tissue in the near infrared range. The end result is much improved tissue penetration, minimizing unwanted excitation outside the focal area, which yields an effective improvement in resolution and sensitivity. The optical system is also simplified and, more importantly, phototoxicity is reduced. These advantages are at the source of the success of two-photon microscopy for functional cellular imaging in situ. Yet, we still face further challenges, reaching the limits of resolution that conventional optics can offer. Here we review some recent advances in optics/photonics approaches that hold promises to improve our ability to probe the tissue in finer areas, at faster speed, and deeper into the tissue. These include super-resolution techniques, introduction of non paraxial optics in microscopy and use of amplified femtosecond lasers, yielding enhanced spatial and temporal resolution as well as tissue penetration.  相似文献   

7.
Optical fibers guide light between separate locations and enable new types of fluorescence imaging. Fiber-optic fluorescence imaging systems include portable handheld microscopes, flexible endoscopes well suited for imaging within hollow tissue cavities and microendoscopes that allow minimally invasive high-resolution imaging deep within tissue. A challenge in the creation of such devices is the design and integration of miniaturized optical and mechanical components. Until recently, fiber-based fluorescence imaging was mainly limited to epifluorescence and scanning confocal modalities. Two new classes of photonic crystal fiber facilitate ultrashort pulse delivery for fiber-optic two-photon fluorescence imaging. An upcoming generation of fluorescence imaging devices will be based on microfabricated device components.  相似文献   

8.
Although optical absorption is strongly associated with the physiological status of biological tissue, existing high-resolution optical imaging modalities, including confocal microscopy, two-photon microscopy and optical coherence tomography, do not sense optical absorption directly. Furthermore, optical scattering prevents these methods from imaging deeper than approximately 1 mm below the tissue surface. Here we report functional photoacoustic microscopy (fPAM), which provides multiwavelength imaging of optical absorption and permits high spatial resolution beyond this depth limit with a ratio of maximum imaging depth to depth resolution greater than 100. Reflection mode, rather than orthogonal or transmission mode, is adopted because it is applicable to more anatomical sites than the others. fPAM is demonstrated with in vivo imaging of angiogenesis, melanoma, hemoglobin oxygen saturation (sO2) of single vessels in animals and total hemoglobin concentration in humans.  相似文献   

9.
Graded Index (GRIN) rod microlenses are increasingly employed in the assembly of optical probes for microendoscopy applications. Confocal, two-photon and optical coherence tomography (OCT) based on GRIN optical probes permit in-vivo imaging with penetration depths into tissue up to the centimeter range. However, insertion of the probe can be complicated by the need of several alignment and focusing mechanisms along the optical path. Furthermore, resolution values are generally not limited by diffraction, but rather by optical aberrations within the endoscope probe and feeding optics. Here we describe a multiphoton confocal fluorescence imaging system equipped with a compact objective that incorporates a GRIN probe and requires no adjustment mechanisms. We minimized the effects of aberrations with optical compensation provided by a low-order electrostatic membrane mirror (EMM) inserted in the optical path of the confocal architecture, resulting in greatly enhanced image quality.  相似文献   

10.
The development of hybrid optical tomography methods to improve imaging performance has been suggested over a decade ago and has been experimentally demonstrated in animals and humans. Here we examined in vivo performance of a camera-based hybrid fluorescence molecular tomography (FMT) system for 360° imaging combined with X-ray computed tomography (XCT). Offering an accurately co-registered, information-rich hybrid data set, FMT-XCT has new imaging possibilities compared to stand-alone FMT and XCT. We applied FMT-XCT to a subcutaneous 4T1 tumor mouse model, an Aga2 osteogenesis imperfecta model and a Kras lung cancer mouse model, using XCT information during FMT inversion. We validated in vivo imaging results against post-mortem planar fluorescence images of cryoslices and histology data. Besides offering concurrent anatomical and functional information, FMT-XCT resulted in the most accurate FMT performance to date. These findings indicate that addition of FMT optics into the XCT gantry may be a potent upgrade for small-animal XCT systems.  相似文献   

11.
Fluorescence lifetime is an intrinsic parameter of the fluorescent probe, independent of the probe concentration but sensitive to changes in the surrounding microenvironment. Therefore, fluorescence lifetime imaging could potentially be applied to in vivo diagnostic assessment of changes in the tissue microenvironment caused by disease, such as ischemia. The aim of this study was to evaluate the utility of noninvasive fluorescence lifetime imaging in distinguishing between normal and ischemic kidney tissue in vivo. Mice were subjected to 60-minute unilateral kidney ischemia followed by 6-hour reperfusion. Animals were then injected with the near-infrared fluorescence probe Cy5.5 or saline and imaged using a time-domain small-animal optical imaging system. Both fluorescence intensity and lifetime were acquired. The fluorescence intensity of Cy5.5 was clearly reduced in the ischemic compared with the contralateral kidney, and the fluorescence lifetime of Cy5.5 was not detected in the ischemic kidney, suggesting reduced kidney clearance. Interestingly, the two-component lifetime analysis of endogenous fluorescence at 700 nm distinguished renal ischemia in vivo without the need for Cy5.5 injection for contrast enhancement. The average fluorescence lifetime of endogenous tissue fluorophores was a sensitive indicator of kidney ischemia ex vivo. The study suggests that fluorescence lifetime analysis of endogenous tissue fluorophores could be used to discriminate ischemic or necrotic tissues by noninvasive in vivo or ex vivo organ imaging.  相似文献   

12.
用蒙特卡罗方法模拟光在多层组织中的吸收特性   总被引:2,自引:0,他引:2  
在讨论目前新颖的组织功能成像打骂能性(例如光声成像)时,光子在组织中的吸收和散射特性是一个很重要的问题,鉴于这一点,本文利用一个多层模型研究了光子在皮肤,脂肪和肌肉组织中的吸收和散射特性,得到了在组织中某一深度处光子在一个平面上的吸收分布,以及在不同吸收系数和散射系数的情况下,光子的反射,吸收和透射几率,结果表明在经过多次散射后,大部分的光子被吸收,在本文的模型中只有7.3%的光子从表面反射(包括镜面反射和漫反射),还讨论了不同光学参灵敏对参流分布的影响。  相似文献   

13.
The rate of complete resection of glioma has improved with the introduction of 5‐aminolevulinic acid‐induced protoporphyrin IX (PpIX) fluorescence image guidance. Surgical outcomes are further enhanced when the fluorescence signal is decoupled from the intrinsic tissue optical absorption and scattering obtained from diffuse reflectance measurements, yielding the absolute PpIX concentration, [PpIX]. Spatial frequency domain imaging was used previously to measure [PpIX] in near‐surface tumors under blue fluorescence excitation. Here, we extend this to subsurface [PpIX] fluorescence under red‐light excitation. The decay rate of the modulation amplitude of the fluorescence signal was used to calculate the PpIX depth, which was then applied in a forward diffusion model to estimate [PpIX] at depth. For brain‐like optical properties in phantoms with PpIX fluorescent inclusions, the depth can be recovered up to depths of 9.5 mm ± 0.4 mm, with [PpIX] ranging from 5 to 15 μg/mL within an average deviation of 15% from the true [PpIX] value.   相似文献   

14.
Hard X-ray fluorescence microscopy and magnified phase contrast imaging are combined to obtain quantitative maps of the projected metal concentration in whole cells. The experiments were performed on freeze dried cells at the nano-imaging station ID22NI of the European Synchrotron Radiation Facility (ESRF). X-ray fluorescence analysis gives the areal mass of most major, minor and trace elements; it is validated using a biological standard of known composition. Quantitative phase contrast imaging provides maps of the projected mass and is validated using calibration samples and through comparison with Atomic Force Microscopy and Scanning Transmission Ion Microscopy. Up to now, absolute quantification at the sub-cellular level was impossible using X-ray fluorescence microscopy but can be reached with the use of the proposed approach.  相似文献   

15.
16.
X-ray fluorescence experiments at the Photon Factory in Japan are described. An energy-dispersive X-ray fluorescence system was combined with various excitation modes, i.e., a continuum and a monochromatic excitation, which consist of a crystal monochromator or a wide band pass monochromator. These excitation modes provide a wide range of band width and photon flux of excitation beams. Minimum detection limits obtained for a thin sample were less than 0.1 ppm and 0.1 pg when there was no line interference. Advantages of using monochromatic excitation are discussed, with emphasis on the possibility of chemical state analysis. Grazing incidence X-ray fluorescence is a technique very appropriate to synchrotron radiation characteristics. Near-surface analysis and trace analysis of solution samples placed on a total reflection support were made. Future plans are discussed, including microbeam analysis, tomography, X-ray excited optical fluorescence, and applications of insertion devices (undulator and wiggler).  相似文献   

17.
Metallic particles and surfaces display diverse and complex optical properties. Examples include the intense colors of noble metal colloids, surface plasmon resonance absorption by thin metal films, and quenching of excited fluorophores near the metal surfaces. Recently, the interactions of fluorophores with metallic particles and surfaces (metals) have been used to obtain increased fluorescence intensities, to develop assays based on fluorescence quenching by gold colloids, and to obtain directional radiation from fluorophores near thin metal films. For metal-enhanced fluorescence it is difficult to predict whether a particular metal structure, such as a colloid, fractal, or continuous surface, will quench or enhance fluorescence. In the present report we suggest how the effects of metals on fluorescence can be explained using a simple concept, based on radiating plasmons (RPs). The underlying physics may be complex but the concept is simple to understand. According to the RP model, the emission or quenching of a fluorophore near the metal can be predicted from the optical properties of the metal structures as calculated from electrodynamics, Mie theory, and/or Maxwell's equations. For example, according to Mie theory and the size and shape of the particle, the extinction of metal colloids can be due to either absorption or scattering. Incident energy is dissipated by absorption. Far-field radiation is created by scattering. Based on our model small colloids are expected to quench fluorescence because absorption is dominant over scattering. Larger colloids are expected to enhance fluorescence because the scattering component is dominant over absorption. The ability of a metal's surface to absorb or reflect light is due to wavenumber matching requirements at the metal-sample interface. Wavenumber matching considerations can also be used to predict whether fluorophores at a given distance from a continuous planar surface will be emitted or quenched. These considerations suggest that the so called "lossy surface waves" which quench fluorescence are due to induced electron oscillations which cannot radiate to the far-field because wavevector matching is not possible. We suggest that the energy from the fluorophores thought to be lost by lossy surface waves can be recovered as emission by adjustment of the sample to allow wavevector matching. The RP model provides a rational approach for designing fluorophore-metal configurations with the desired emissive properties and a basis for nanophotonic fluorophore technology.  相似文献   

18.
Achieving a maximal safe extent of resection during brain tumor surgery is the goal for improved patient prognosis. Fluorescence‐guided neurosurgery using 5‐aminolevulinic acid (5‐ALA) induced protoporphyrin IX has thereby become a valuable tool enabling a high frequency of complete resections and a prolonged progression‐free survival in glioblastoma patients. We present a widefield fluorescence lifetime imaging device with 250 mm working distance, working under similar conditions such as surgical microscopes based on a time‐of‐flight dual tap CMOS camera. In contrast to intensity‐based fluorescence imaging, our method is invariant to light scattering and absorption while being sensitive to the molecular composition of the tissue. We evaluate the feasibility of lifetime imaging of protoporphyrin IX using our system to analyze brain tumor phantoms and fresh 5‐ALA‐labeled human tissue samples. The results demonstrate the potential of our lifetime sensing device to go beyond the limitation of current intensity‐based fluorescence‐guided neurosurgery.   相似文献   

19.
Nonlinear magic: multiphoton microscopy in the biosciences   总被引:21,自引:0,他引:21  
Multiphoton microscopy (MPM) has found a niche in the world of biological imaging as the best noninvasive means of fluorescence microscopy in tissue explants and living animals. Coupled with transgenic mouse models of disease and 'smart' genetically encoded fluorescent indicators, its use is now increasing exponentially. Properly applied, it is capable of measuring calcium transients 500 microm deep in a mouse brain, or quantifying blood flow by imaging shadows of blood cells as they race through capillaries. With the multitude of possibilities afforded by variations of nonlinear optics and localized photochemistry, it is possible to image collagen fibrils directly within tissue through nonlinear scattering, or release caged compounds in sub-femtoliter volumes.  相似文献   

20.
Small animals optical imaging systems are widely used in pre-clinical research to image in vivo the bio-distribution of light emitting probes using fluorescence or bioluminescence modalities. In this work we presented a set of simulated results of a novel small animal optical imaging module based on a fibers optics matrix, coupled with a position sensitive detector, devoted to acquire bioluminescence and Cerenkov images. Simulations were performed using GEANT 4 code with the GAMOS architecture using the tissue optics plugin. Results showed that it is possible to image a 30 × 30 mm region of interest using a fiber optics array containing 100 optical fibers without compromising the quality of the reconstruction. The number of fibers necessary to cover an adequate portion of a small animal is thus quite modest. This design allows integrating the module with magnetic resonance (MR) in order to acquire optical and MR images at the same time. A detailed model of the mouse anatomy, obtained by segmentation of 3D MRI images, will improve the quality of optical 3D reconstruction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏