首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
This article reports the first randomized prospective multicenter evaluation of a bioabsorbable conduit for nerve repair. The study enrolled 98 subjects with 136 nerve transections in the hand and prospectively randomized the repair to two groups: standard repair, either end-to-end or with a nerve graft, or repair using a polyglycolic acid conduit. Two-point discrimination was measured by a blinded observer at 3, 6, 9, and 12 months after repair. There were 56 nerves repaired in the control group and 46 nerves repaired with a conduit available for follow-up. Three patients had a partial conduit extrusion as a result of loss of the initially crushed skin flap. The overall results showed no significant difference between the two groups as a whole. In the control group, excellent results were obtained in 43 percent of repairs, good results in 43 percent, and poor results in 14 percent. In those nerves repaired with a conduit, excellent results were obtained in 44 percent, good results in 30 percent, and poor results in 26 percent (p = 0.46). When the sensory recovery was examined with regard to length of nerve gap, however, nerves with gaps of 4 mm or less had better sensation when repaired with a conduit; the mean moving two-point discrimination was 3.7 +/- 1.4 mm for polyglycolic acid tube repair and 6.1 +/- 3.3 mm for end-to-end repairs (p = 0.03). All injured nerves with deficits of 8 mm or greater were reconstructed with either a nerve graft or a conduit. This subgroup also demonstrated a significant difference in favor of the polyglycolic acid tube. The mean moving two-point discrimination for the conduit was 6.8 +/- 3.8 mm, with excellent results obtained in 7 of 17 nerves, whereas the mean moving two-point discrimination for the graft repair was 12.9 +/- 2.4 mm, with excellent results obtained in none of the eight nerves (p < 0.001 and p = 0.06, respectively). This investigation demonstrates improved sensation when a conduit repair is used for nerve gaps of 4 mm or less, compared with end-to-end repair of digital nerves. Polyglycolic acid conduit repair also produces results superior to those of a nerve graft for larger nerve gaps and eliminates the donor-site morbidity associated with nerve-graft harvesting.  相似文献   

2.
A custom-designed polyglycolic acid (PGA) bioabsorbable nerve conduit was used to reconstruct a 25-mm defect in the right inferior alveolar nerve. The initial nerve injury, following a dental extraction, resulted in loss of lower lip sensation and severe facial pain. Sixteen months after tooth extraction, with no improvement in symptomatology, the alveolar canal was enlarged in diameter by means of mandibular osteotomy to accommodate a 2-mm-diameter polyglycolic acid tube. The proximal end of the inferior alveolar nerve was sutured into the polyglycolic acid tube. The mental nerve was sutured into the distal end of the tube. Pain of neural origin was relieved in the early postoperative period. Two years following nerve reconstruction, pain relief remains excellent and perception of pressure and vibration is similar to the thresholds for these perceptions on the contralateral lip.  相似文献   

3.
In spite of the extensive research using induced pluripotent stem (iPS) cells, the therapeutic potential of iPS cells in the treatment of peripheral nerve injury is largely unknown. In this study, we repaired peripheral nerve gaps in mice using tissue-engineered bioabsorbable nerve conduits coated with iPS cell-derived neurospheres. The secondary neurospheres derived from mouse iPS cells were suspended in each conduit (4000,000 cells per conduit) and cultured in the conduit in three-dimensional (3D) culture for 14 days. We then implanted them in the mouse sciatic nerve gaps (5 mm) (iPS group; n=10). The nerve conduit alone was implanted in the control group (n=10). After 4, 8 and 12 weeks, motor and sensory functional recovery in mice were significantly better in the iPS group. At 12 weeks, all the nerve conduits remained structurally stable without any collapse and histological analysis indicated axonal regeneration in the nerve conduits of both groups. However, the iPS group showed significantly more vigorous axonal regeneration. The bioabsorbable nerve conduits created by 3D-culture of iPS cell-derived neurospheres promoted regeneration of peripheral nerves and functional recovery in vivo. The combination of iPS cell technology and bioabsorbable nerve conduits shows potential as a future tool for the treatment of peripheral nerve defects.  相似文献   

4.
Clinical nerve reconstruction with a bioabsorbable polyglycolic acid tube   总被引:17,自引:0,他引:17  
Microneurosurgical techniques to reconstruct nerve gaps with nerve grafts frequently fail to achieve excellent functional results and create donor-site morbidity. In the present study, 15 patients had gaps of 0.5 to 3.0 cm (mean 1.7 cm) in digital nerves reconstructed by one surgeon with a bioabsorbable polyglycolic acid (PGA) tube. A final evaluation of sensibility was done by a second surgeon at a mean postoperative interval of 22.4 months (range 11 to 32 months). These were all secondary reconstructions. The evaluation included a digital nerve block with local anesthetic for the intact (not reconstructed) digital nerve. Excellent functional sensation (moving two-point discrimination less than or equal to 3 mm and/or static two-point discrimination less than or equal to 6 mm) was present in 33 percent and good functional sensation (moving two-point discrimination of 4 to 7 mm and/or static two-point discrimination of 7 to 15 mm) in 53 percent of the digital nerve reconstructions. One patient with poor sensory recovery and one with no recovery were judged as functional failures (14 percent). Absence of pain at the site of reconstruction was judged by the patient to be excellent in 40 percent, good in 33 percent, and poor in 27 percent. We conclude that reconstruction of nerve gaps of up to 3.0 cm with a bioabsorbable PGA tube gives clinical results at least comparable to the classic nerve graft technique while avoiding donor-site morbidity.  相似文献   

5.
A new type of a biodegradable nerve graft conduit material, the amnion tube, has been developed in our laboratory. To test the tube in the peripheral nerve regeneration process, it was initially applied across a 1-cm sciatic nerve gap in rats and was compared with other nerve conduit materials. We used male Sprague-Dawley rats as our animal model. The experiment included 66 rats that were randomly assigned into five groups: autograft (n = 17), amnion tube (n = 19), silicone tube (n = 20), no repair (n = 7), and sham group (n = 3). The process of peripheral nerve regeneration was evaluated at 2, 4, 10, and 17 weeks following injury and repair by using morphologic and functional assessments of the outcome of nerve regeneration in each animal. Nerve regeneration across the amnion tube nerve conduit was comparable with that seen in autograft and superior to that of the silicone group. A uniform nerve tissue was seen filling and crossing the amnion conduit, and the regenerated nerve from the proximal stump reached the distal end and was undifferentiated from the normal nerve tissues. At 4 months, the amnion tube biodegraded and no longer could be identified and differentiated from the nerve tissues. The amnion tube animal group showed a number of axons very close to that in the nerve autograft group (37,157 versus 33,054). Functional recovery at a 2- to 4-week interval was significantly statistically higher only in the amnion tube animal group (p = 0.01). However, the improvement disappeared between 10 and 17 weeks. In conclusion, the amnion tube is a potential ideal nerve conduit material secondary to its unique characteristics: it contains important neurotropic factors, is biodegradable, provokes a very weak immune response, is semiflexible, is readily available, and is easily manufactured into different sizes and diameters.  相似文献   

6.
A major problem hindering the development of autograft alternatives for repairing peripheral nerve injuries is immunogenicity. We have previously shown successful regeneration in transected rat sciatic nerves using conduits filled with allogeneic dorsal root ganglion (DRG) cells without any immunosuppression. In this study, we re-examined the immunogenicity of our DRG neuron implanted conduits as a potential strategy to overcome transplant rejection. A biodegradable NeuraGen® tube was infused with pure DRG neurons or Schwann cells cultured from a rat strain differing from the host rats and used to repair 8 mm gaps in the sciatic nerve. We observed enhanced regeneration with allogeneic cells compared to empty conduits 16 weeks post-surgery, but morphological analyses suggest recovery comparable to the healthy nerves was not achieved. The degree of regeneration was indistinguishable between DRG and Schwann cell allografts although immunogenicity assessments revealed substantially increased presence of Interferon gamma (IFN-γ) in Schwann cell allografts compared to the DRG allografts by two weeks post-surgery. Macrophage infiltration of the regenerated nerve graft in the DRG group 16 weeks post-surgery was below the level of the empty conduit (0.56 fold change from NG; p<0.05) while the Schwann cell group revealed significantly higher counts (1.29 fold change from NG; p<0.001). Major histocompatibility complex I (MHC I) molecules were present in significantly increased levels in the DRG and Schwann cell allograft groups compared to the hollow NG conduit and the Sham healthy nerve. Our results confirmed previous studies that have reported Schwann cells as being immunogenic, likely due to MHC I expression. Nerve gap injuries are difficult to repair; our data suggest that DRG neurons are superior medium to implant inside conduit tubes due to reduced immunogenicity and represent a potential treatment strategy that could be preferable to the current gold standard of autologous nerve transplant.  相似文献   

7.
The purpose of this study was to determine the efficacy of autogenous vein grafts as nerve grafts (AVNC) for bridging of small peripheral sensory nerve gaps as compared with direct repair and with conventional nerve grafting techniques (ANG). Patients with painful neuroma or segmental nerve injury of 3 cm were chosen as the test group. Those amenable to direct repair were classified as controls. Between 1982 to 1988, a total of 22 patients were enrolled in this study. A total of 34 nerves were repaired, 15 with a venous nerve conduit, 4 with a sural nerve graft, and 15 with direct repair. Significant symptom relief and satisfactory sensory function return were uniformly observed. The two-point discrimination measurements indicated superiority of direct repair and probably of conventional nerve grafting. However, the universally favorable patient acceptance and the return of measurable two-point discrimination indicates the effectiveness of autogenous vein grafts as nerve conduits when selectively applied to bridge a small nerve gap (less than or equal to 3 cm) on nonessential peripheral sensory nerves.  相似文献   

8.
The nerve conduits have been developed for nerve defect repair. However, no artificial conduits have obtained comparable results to autografts to bridge the large gaps. A possible reason for this poor performance may be a lack of sustainable neurotrophic support for axonal regrowth. Previous studies suggested nanocomposite conduits can be used as a carrier for valproic acid (VPA), a common drug that can produce effects similar to the neurotrophic factors. Here, we developed the novel bioabsorbable conduits based on hydroxyapatite/poly d -l -lactic acid (PDLLA)/poly{(lactic acid)-co-[(glycolic acid)-alt-(l -lysine)]} with sustained release of VPA. Firstly, the sustained release of VPA in this conduit was examined by high-performance liquid chromatography. Then Schwann cells were treated with the conduit extracts. The cell metabolic activity and proliferation were assayed by 3-[4,5-dimethyl-2-thiazolyl]-2,5-diphenyl-2-tetrazolium bromide and bromodeoxyuridine staining. A 10-mm segment of rat sciatic nerve was resected and then repaired, respectively, using the VPA conduit (Group A), the PDLLA conduit (Group B), or the autografts (Group C). Nerve conduction velocities (NCVs), compound muscle action potentials (CMAPs), and histological staining were assayed following the surgery. The cell metabolic activity and proliferation were significantly increased (p < .05) by the extracts from VPA-conduit extract compared to others. NCVs and CMAPs were significantly higher in Groups A and C than Group B (p < .05). The nerve density of Groups A and C was higher than Group B. There was no significant difference between Groups A and C. Taken together, this study suggested the sustained-release VPA conduit promoted peripheral nerve regeneration that was comparable to the autografts. It holds potential for future use in nerve regeneration.  相似文献   

9.
Abstract

A nanofibrous PHBV nerve conduit has been used to evaluate its efficiency based on the promotion of nerve regeneration in rats. The designed conduits were investigated by physical, mechanical and microscopic analyses. The conduits were implanted into a 30-mm gap in the sciatic nerves of the rats. Four months after surgery, the regenerated nerves were evaluated by macroscopic assessments and histology. This polymeric conduit had sufficiently high mechanical properties to serve as a nerve guide. The results demonstrated that in the nanofibrous graft with cells, the sciatic nerve trunk had been reconstructed with restoration of nerve continuity and formatted nerve fibers with myelination. For the grafts especially the nanofibrous conduits with cells, muscle cells of gastrocnemius on the operated side were uniform in their size and structures. This study proves the feasibility of artificial conduit with Schwann cells for nerve regeneration by bridging a longer defect in a rat model.  相似文献   

10.
神经生长因子与冻干异体神经桥接大鼠神经缺损的研究   总被引:3,自引:0,他引:3  
实验采用冻干处理的异体神经与外源性神经生长因子(NGF)结合来桥接大鼠的坐骨神经1.0cm的缺损。用雄性Wistar大鼠进行的四组实验结果表明:冻干处理的异体神经可降低其抗原性,但处理后并不损害雪旺氏细胞(SC)基底膜的完整性,在移植后可能成为轴突再生的通道和支架;外源性NGF与冻干神经结合形成的复合体,可为神经的再生提供一个较好的微环境,具有成为理想桥接材料的可能性  相似文献   

11.
The limited availability of donor sites for nerve grafts and their inherent associated morbidity continue to stimulate research toward finding suitable alternatives. In the following study, the effect of direct administration of nerve growth factor (NGF) into a nerve conduit across a gap was tested in a rat sciatic nerve model. A 1-cm segment of the right sciatic nerve in Sprague-Dawley rats was resected, and the gap was then bridged using one of three methods: group I (NGF-treated group, n = 12), a vein graft filled with NGF (100 ng in 0.3-ml phosphate buffered saline); group II (control group, n = 12), a vein graft filled with phosphate buffered saline only; group III (standard nerve graft, n = 11), a resected segment of the sciatic nerve. All animals were evaluated at 3 and 5 weeks by behavioral testing and at 5 weeks by electrophysiologic testing. At 3 weeks, sensory testing showed that the latency to a noxious stimulus in group I animals (8.0 +/- 5.4 sec, mean +/- SD) was significantly lower than that of group II animals (13.2 +/- 6.5 sec), indicating that sensory recovery was superior in the animals receiving NGF. The mean latency of animals in group III was 12.9 +/- 6.5 sec, but the difference between the latencies of group I and group III did not reach statistical significance. At 5 weeks, there was no difference in sensory testing between groups. Motor function in groups I and III as measured by walk pattern analysis was superior to that of group II at 5 weeks (toe spread ratios 0.66 +/- 0.09, 0.48 +/- 0.07, and 0.69 +/- 0.09 for groups I, II, and III, respectively). Mean motor conduction velocities across the 1-cm gap were 8.6 +/- 4.7 m/sec, 2.5 +/- 0.7 m/sec, and 6.9 +/- 2.9 m/sec in groups I, II, and III respectively. The difference between groups I and III was not statistically significant, but the motor conduction velocity of group II was significantly slower than that of either group I or III (p < 0.002). The positive effects of NGF on regeneration of nerves across a gap seen in this study suggest that it may be useful for treating peripheral nerve injuries in combination with autogenous vein grafts.  相似文献   

12.
Nerve regeneration across peripheral nerve allografts and control autografts in primates immunosuppressed with Cyclosporin A was quantitatively evaluated by electrophysiologic and histologic methods. Twelve cynomolgus monkeys received 3-cm autografts and allografts in contralateral ulnar nerves. They were immunosuppressed with Cyclosporin A at 25 mg/kg per day or placebo vehicle. Morphometric analysis of nerve graft and distal nerve segments was assessed at 1 year after engraftment. Quantitative electrophysiologic studies were performed percutaneously at 6 and 12 months, and compound action potentials were measured directly across the nerve grafts at 1 year. Excellent regeneration was seen across autografts and allografts in Cyclosporin A-treated and placebo-treated recipients.  相似文献   

13.
Glial‐derived neurotrophic factor (GDNF) and nerve growth factor (NGF) have both been shown to enhance peripheral nerve regeneration following injury and target different neuronal populations. The delivery of either growth factor at the site of injury may, therefore, result in quantitative differences in motor nerve regeneration and functional recovery. In this study we evaluated the effect of affinity‐based delivery of GDNF or NGF from fibrin‐filled nerve guidance conduits (NGCs) on motor nerve regeneration and functional recovery in a 13 mm rat sciatic nerve defect. Seven experimental groups were evaluated consisting of GDNF or NGF and the affinity‐based delivery system (DS) within NGCs, control groups excluding the DS and/or growth factor, and nerve isografts. Groups with growth factor in the conduit demonstrated equivalent or superior performance in behavioral tests and relative muscle mass measurements compared to isografts at 12 weeks. Additionally, groups with GDNF demonstrated greater specific twitch and tetanic force production in extensor digitorum longus (EDL) muscle than the isograft control, while groups with NGF produced demonstrated similar force production compared to the isograft control. Assessment of motor axon regeneration by retrograde labeling further revealed that the number of ventral horn neurons regenerating across NGCs containing GDNF and NGF DS was similar to the isograft group and these counts were greater than the groups without growth factor. Overall, the GDNF DS group demonstrated superior functional recovery and equivalent motor nerve regeneration compared to the isograft control, suggesting it has potential as a treatment for motor nerve injury. Biotechnol. Bioeng. 2010;106: 970–979. © 2010 Wiley Periodicals, Inc.  相似文献   

14.
Abstract

The aim of this study is to develop a nanofibrous polymeric nerve conduit with Schwann cells (SCs) and to evaluate its efficiency on the promotion of functional and locomotive activities in rats. The conduits were implanted into a 30-mm gap in the sciatic nerves of the rats. Four months after surgery, the rats were monitored and evaluated by behavioral analyses such as toe out angle, toe spreading analysis, walking track analysis, extensor postural thrust, open-field analysis, swimming test and nociceptive function, four months post surgery. Four months post-operatively, the results from behavioral analyses demonstrated that in the grafted groups especially in the grafted group with SCs, the rat sciatic nerve trunk had been reconstructed with functional recovery such as walking, swimming and recovery of nociceptive function. This study proves the feasibility of artificial conduit with SCs for nerve regeneration by bridging a longer defect in the rat model.  相似文献   

15.
In this study, the right sciatic nerves of 40 rats were used to determine whether a nerve graft within a vein graft might accelerate and facilitate axonal regeneration, compared with a nerve graft alone. The animals were separated into four groups, as follows: group 1, sham control; group 2 (control), segmental nerve resection and no repair; group 3, segmental nerve resection and nerve grafting; group 4, segmental nerve resection and reconstruction with a nerve graft within a vein conduit graft. For all groups, sciatic functional indices were calculated before the operation and on postoperative days 7 and 90. On postoperative day 90, the sciatic nerves were reexposed and nerve conduction velocities were recorded. The sciatic nerves were harvested from all groups for counting of the myelinated axons with a stereological method. No statistically significant differences with respect to return of gait function, axon count, or nerve conduction were noted between groups 3 and 4 (p > 0.05). However, functional recovery in group 4 on postoperative day 90 was significant, compared with group 2 (p < 0.05); the recovery difference between groups 2 and 3 was not significant (p > 0.05). This study was not able to demonstrate any functional benefits with the use of a nerve graft within a vein graft, compared with standard nerve grafting.  相似文献   

16.
Autologous nerve grafts are the current “gold standard” for repairing large nerve gaps. However, they cause morbidity at the donor nerve site and only a limited amount of nerve can be harvested. Nerve conduits are a promising alternative to autografts and can act as guidance cues for the regenerating axons, without the need to harvest donor nerve. Separately, it has been shown that localized delivery of GDNF can enhance axon growth and motor recovery. FK506, an FDA approved small molecule, has also been shown to enhance peripheral nerve regeneration. This paper describes the design of a novel hole-based drug delivery apparatus integrated with a polytetrafluoroethylene (PTFE) nerve conduit for controlled local delivery of a protein such as GDNF or a small molecule such as FK506. The PTFE devices were tested in a diffusion chamber, and the bioactivity of the released media was evaluated by measuring neurite growth of dorsal root ganglions (DRGs) exposed to the released drugs. The drug delivering nerve guide was able to release bioactive concentrations of FK506 or GDNF. Following these tests, optimized drug releasing nerve conduits were implanted across 10 mm sciatic nerve gaps in a BL6 yellow fluorescent protein (YFP) mouse model, where they demonstrated significant improvement in muscle mass, compound muscle action potential, and axon myelination in vivo as compared with nerve conduits without the drug. The drug delivery nerve guide could release drug for extended periods of time and enhance axon growth in vitro and in vivo.  相似文献   

17.

Objectives/Hypothesis

Due to its anatomical features, the chorda tympani nerve (CTN) is sometimes sacrificed during middle ear surgery, resulting in taste dysfunction. We examined the effect of placing an artificial nerve conduit, a polyglycolic acid (PGA)-collagen tube, across the gap in the section of the resected chorda tympani nerve (CTN) running through the tympanic cavity.

Methods

The CTN was reconstructed with a PGA-collagen tube in three patients with taste disturbance who underwent CTN resection. To evaluate the effect of the reconstruction procedure on the patients'' gustatory function, we measured the patients'' electrogustometry (EGM) thresholds. The patients were followed-up for at least two years.

Results

Gustatory function was completely restored in all of the patients after the reconstruction. The patients'' EGM thresholds exhibited early improvements within one to two weeks and had returned to their normal ranges within three months. They subsequently remained stable throughout the two-year follow-up period. In a patient who underwent a second surgical procedure, it was found that the PGA-collagen tube used in the first surgical procedure had been absorbed and replaced by new CTN fibers with blood vessels on their surfaces.

Conclusion

These results suggest that reconstruction of the CTN with an artificial nerve conduit, a PGA-collagen tube, allows functional and morphological regeneration of the nerve and facilitates the recovery of taste function. PGA-collagen tubes might be useful for repairing CTNs that are resected during middle ear surgery. Further research is required to confirm these preliminary results although this is the first report to describe the successful regeneration of a nerve running through an aerial space.  相似文献   

18.
Target-specific nerve regeneration through a nerve guide in the rat   总被引:6,自引:0,他引:6  
Nerve regeneration across a gap in peripheral nerve has been achieved through various nonneural nerve guides in both lower and primate species. This technique can only be useful if the regenerated nerve cable grows specifically to and reinnervates the appropriate distal target. In this study, the proximal peroneal fascicle of rat sciatic nerve was inserted into the proximal limb of a Y-shaped nerve guide. Distal peroneal and tibial fascicles were placed within the two distal limbs of the same Y. The proximal peroneal nerve grew preferentially by a 2:1 ratio to the appropriate distal peroneal fascicle suggesting that target-specific reinnervation is possible through a nerve guide.  相似文献   

19.
A simple reaction-diffusion model has been developed to describe the mass transport of nutrients and nerve growth factor within a bioartificial nerve graft (BNG). The BNG consists of a porous polymer conduit that is preseeded with Schwann cells in its lumen. The Schwann cells produce growth factors to stimulate nerve regeneration within the lumen of the conduit. The model can predict the wall thickness, porosity, and Schwann cell seeding density needed to maximize the axon extension rate while ensuring that sufficient nutrients, especially oxygen, are made available to the neurons until the formation of the neovasculature. The model predicts a sixteen-fold increase in the levels of nerve growth factor by dropping the porosity from 95 to 55% but only at the expense of reducing the oxygen concentration. At higher porosities, increasing the wall thickness and increasing the Schwann cell seeding density both have the same effect of increasing the concentration of nerve growth factor within the lumen of the conduit. This model provides a simple tool for evaluating various conduit designs before continuing with experimental studies in vivo.  相似文献   

20.
BackgroundElectrical stimulation (ES) has been shown to promote nerve regeneration in rats with experimental diabetes induced using streptozotocin (STZ). However, the time-course effect of ES on nerve regeneration of diabetic animals has not been reported in previous studies. The present study attempted to examine the effect of different timing of ES after peripheral nerve transection in diabetic rats.Methodology/FindingsFifty Sprague-Dawley rats were used in the study. They were classified into five groups. STZ-induced diabetes was created in groups A to D. Normal animals in group E were used as the non-diabetic controls. The sciatic nerve was transected and repaired using a silicone rubber conduit across a 10-mm gap in all groups. Groups A to C received ES for 15 minutes every other day for 2 weeks. Stimulation was initiated on day 1 following the nerve repair for group A, day 8 for group B, and day 15 for group C. The diabetic control group D and the normal control group E received no ES. At 30 days after surgery in group A, histological evaluations showed a higher success percentage of regeneration across the 10-mm nerve gap, and the electrophysiological results showed significantly larger mean values of evoked muscle action potential area and amplitude of the reinnervated gastrocnemius muscle compared with group D.Conclusions/SignificanceIt is concluded that an immediate onset of ES may improve the functional recovery of large nerve defect in diabetic animals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号