首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method to determine the enantiomers of the muscle relaxant baclofen in human plasma and cerebrospinal fluid (CSF) has been developed. A commercially available ultrafiltration membrane is used to prepare the sample. A chiral CROWNPAK CR(+) stationary phase column is then used to perform complete resolution of the S(+)- and R(-)-enantiomers of baclofen. This method was used to analyze human plasma and CSF spiked with baclofen, and the calibration curves for both biologic samples were linear over a concentration range of 0.15-150 ng enantiomer/ml. The lower limit of quantification was 0.15 ng enantiomer/ml in both fluids. Finally, the method was tested with an artificial CSF as an alternative to authentic human CSF. The results showed that no matrix effects and no interfering peaks were observed using this artificial CSF.  相似文献   

2.
A sensitive and enantioselective method was developed and validated for the determination of ondansetron enantiomers in human plasma using enantioselective liquid chromatography-tandem mass spectrometry. The enantiomers of ondansetron were extracted from plasma using ethyl acetate under alkaline conditions. HPLC separation was performed on an ovomucoid column using an isocratic mobile phase of methanol-5 mM ammonium acetate-acetic acid (20:80:0.02, v/v/v) at a flow rate of 0.40 mL/min. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, using the transitions of m/z 294-->170 for ondansetron enantiomers, and m/z 285-->124 for tropisetron (internal standard). The method was linear in the concentration range of 0.10-40 ng/mL for each enantiomer using 200 microL of plasma. The lower limit of quantification (LLOQ) for each enantiomer was 0.10 ng/mL. The intra- and inter-assay precision was 3.7-11.6% and 5.6-12.3% for R-(-)-ondansetron and S-(+)-ondansetron, respectively. The accuracy was 100.4-107.1% for R-(-)-ondansetron and 103.3-104.9% for S-(+)-ondansetron. No chiral inversion was observed during the plasma storage, preparation and analysis. The method was successfully applied to characterize the pharmacokinetic profiles of ondansetron enantiomers in healthy volunteers after an intravenous infusion of 8 mg racemic ondansetron.  相似文献   

3.
A stereoselective reversed-phase HPLC assay to determine S-(-) and R-(+) enantiomers of esmolol in human plasma was developed. The method involved liquid-liquid extraction of esmolol from human plasma, using S-(-)-propranolol as the internal standard, and employed 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The derivatized products were separated on a 5-microm reversed-phase C18 column with a mixture of acetonitrile/0.02 mol/L phosphate buffer (pH 4.5) (55:45, v/v) as mobile phase. The detection of esmolol derivatives was made at lambda=224 nm with UV detector. The assay was linear from 0.035 to 12 microg/ml for each enantiomer. The analytical method afforded average recoveries of 94.8% and 95.5% for S-(-)- and R-(+)-esmolol, respectively. For each enantiomer, the limit of detection was 0.003 microg/ml and the limit of quantification for the method was 0.035 microg/ml (RSD<14%). The reproducibility of the assay was satisfactory.  相似文献   

4.
A high-performance liquid chromatographic method for the enantiospecific quantitation of S- and R-mephenytoin and its metabolites S- and R-nirvanol and S- and R-4'-hydroxymephenytoin in plasma is described. The compounds were separated using a reversed-phase C(2) column in tandem with a chiral alpha(1)-acid glycoprotein column and were detected using ultraviolet detection at 205 nm. The lower limit of quantification was 10 ng/ml for all compounds using 0.5 ml human plasma (intra-day coefficient of variation <13%, accuracy <+/-20%). The method was validated for human plasma in the concentration range 10-2000 ng/ml for each of the six compounds. The method allows for the simultaneous characterisation of the metabolic capacity of two human drug-metabolising enzymes, CYP2C19 and CYP2B6, and may be used when investigating polymorphisms or changes in activity of these two enzymes.  相似文献   

5.
A high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI/MS) method for simultaneous stereoselective analysis of venlafaxine (VEN) and its major metabolite O-desmethylvenlafaxine (ODV) enantiomers in human plasma has been developed and validated. Chiral chromatography is performed on the CHRIOBIOTIC V (5 microm, 250 mm x 4.6 mm) column with mobile phase constituted of 30 mmol/l ammonium acetate-methanol (15:85, pH 6.0) at a flow rate of 1.0 ml/min and a postcolumn splitting ratio of 3:1. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and detected using the selected ion recording (SIR) mode. Calibration curves obtained from spiked plasma were linear in the range of 5.0-400 ng/ml for S-(+)-VEN and R-(-)-VEN, 4.0-280 ng/ml for S-(+)-ODV and R-(-)-ODV, respectively, with linear correlation coefficient all above 0.999. The average extraction recoveries for all the four analytes were above 76%. The methodology recoveries were higher than 92%. The limit of detection were 1.0 ng/ml for S-(+)-VEN and R-(-)-VEN, 1.5 ng/ml for S-(+)-ODV and R-(-)-ODV, respectively. The intra- and inter-day variation coefficients were less than 9%.  相似文献   

6.
A sensitive and selective high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of bufuralol enantiomers in plasma and pharmaceutical formulations. Enantiomeric resolution was achieved on a vancomycin macrocyclic antibiotic chiral stationary phase (CSP) known as Chirobiotic V with UV detection set at 254 nm. The polar ionic mobile phase (PIM) consisting of methanol-glacial acetic acid-triethylamine (100:0.015:0.010, v/v/v) has been used at a flow rate of 0.5 ml/min. The method is highly specific where other coformulated compounds did not interfere. The stability of bufuralol enantiomers under different degrees of temperature was also studied. The results showed that the drug is stable for at least 7 days at 70 degrees C. The method was validated for its linearity, accuracy, precision and robustness. An experimental design was used during validation to evaluate method robustness. The calibration curves in plasma were linear over the range of 5-500 ng/ml for each enantiomer with detection limit of 2 ng/ml. The mean relative standard deviation (RSD) of the results of within-day precision and accuracy of the drug were 0.05) between inter- and intra-day studies for each enantiomer which confirmed the reproducibility of the assay method. The mean extraction efficiency for S-(-)- and R-(+)-bufuralol from plasma was in the range 97-102% at 15-400 ng/ml level for each enantiomer. The overall recoveries of bufuralol enantiomers from pharmaceutical formulations was in the range 99.6-102.2% with %RSD ranging from 1.06 to 1.16%. The assay method proved to be suitable as chiral quality control for bufuralol formulations by HPLC and for therapeutic drug monitoring.  相似文献   

7.
A sensitive stereoselective bioanalytical liquid chromatographic assay with mass spectrometric detection (LC-MS) was developed and validated for the on-line extraction and quantification of R- and S-methadone and the primary metabolite R- and S-2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) from human plasma. Deproteinized plasma was injected directly onto a small C8 column, washed and then back-flushed using a column switching valve and a second pump onto an alpha1-acid glycoprotein analytical column, and enantioselective separation achieved using a mobile phase gradient of methanol and ammonium formate. Analytes were validated over a range of 0.1-25 ng/ml R- and S-EDDP and 0.1-100ng/ml R- and S-methadone, respectively. Unweighted standard curves were linear over this concentration range (regression coefficients > 0.999). Quality control samples were evaluated at 1, 5, 12.5 ng/ml R- and S-EDDP and 1, 10, 50 ng/ml R- and S-methadone. Intra- and inter-day accuracy was >95%, and intra- and inter-day coefficients of variation were less than 10% for all analytes and concentrations. This assay represents the only method currently available which combines on-line extraction and achieves chiral separation of both methadone and EDDP from plasma, and offers improvements in sensitivity over existing methods.  相似文献   

8.
A sensitive and selective chiral high performance liquid chromatographic method was developed for the direct determination of R- and S-warfarin enantiomers in human plasma. The method involved direct injection of human plasma onto a semipermeable surface (SPS) guard column, washing the proteins from the column with aqueous acetonitrile and back flushing the analytes onto a reversed phase ovomucoid silica HPLC column using switching valves. After separation, the analytes were simultaneously detected and quantitated with a fluorometer. The recoveries of R-warfarin from human plasma at 25 and 2500 ng/ml were 98.9% and 88.1%, respectively. The recoveries of S-warfarin at 25 and 2500 ng/ml were 105.4% and 93.9%, respectively. Using 100 microl of human plasma, the lower limit of quantification for both R- and S-warfarins was 25 ng/ml. Linear responses in analyte/internal standard peak height ratios were observed for analyte concentrations ranging from 25 to 2500 ng/ml for both enantiomers. Fluorescence chromatograms of drug-free human plasma showed no interfering peaks with retention times similar to those for R- and S-warfarins and the internal standard. Results from a 3-day validation study for both enantiomers demonstrated excellent precision (1.7-9.0%) and accuracy (97-109%) across the calibration range.  相似文献   

9.
A stereoselective high-performance liquid chromatographic (HPLC) method is described for the selective and sensitive quantitation in human plasma of R-(+)- and S-(−)-enantiomers of remoxipride. Remoxipride was extracted from basified plasma into hexane-methyl-tert.-butyl ether (20:80, v/v), washed with sodium hydroxide (1.0 M), then back-extracted into phosphoric acid (0.1 M). A structural analog of remoxipride was used as an internal standard. The sample extracts were chromatographed using a silica-based derivatized cellulose chiral column, Chiralcel OD-R, and a reversed-phase eluent containing 30–32% acetonitrile in 0.1 M potassium hexafluorophosphate. Ultraviolet (UV) absorbance detection was performed at 214 nm. Using 0.5-ml plasma aliquots, the method was validated in the concentration range 0.02-2.0 μg/ml and was applied in the investigation of systemic inversion of remoxipride enantiomers in man.  相似文献   

10.
Enantioselective separations on chiral stationary phases with or without derivatization were developed and compared for the HPLC analysis of (+)-(R)- and (-)-(S)-metoprolol acidic metabolite in human plasma and urine. The enantiomers were analysed in plasma and urine without derivatization on a Chiralcel OD-R column, and in urine after derivatization using methanol in acidic medium on a Chiralcel OD-H column. The quantitation limits were 17 ng of each enantiomer/ml plasma and 0.5 microgram of each enantiomer/ml urine using both methods. The confident limits show that the methods are compatible with pharmacokinetic investigations of the enantioselective metabolism of metoprolol. The methods were employed in a metabolism study of racemic metoprolol administered to a patient phenotyped as an extensive metabolizer of debrisoquine. The enantiomeric ratio (+)-(R)/(-)-(S)-acid metabolite was 1.1 for plasma and 1.2 for urine. Clearances were 0.41 and 0.25 l/h/kg, respectively, for the (+)-(R)- and (-)-(S)-enantiomers. The correlation coefficients between the urine concentrations of the acid metabolite enantiomers obtained by the two methods were >0.99. The two methods demonstrated interchangeable application to pharmacokinetics.  相似文献   

11.
Oh JW  Trung TQ  Sin KS  Kang JS  Kim KH 《Chirality》2007,19(7):528-535
A coupled achiral-chiral high performance liquid chromatographic method was developed and fully validated for the determination of bevantolol enantiomers, (-)-(S)-bevantolol and (+)-(R)-bevantolol, in human plasma. Plasma samples were prepared by solid phase extraction with Sep-Pak Plus C18 cartridges followed by HPLC. Bevantolol enantiomers and (+)-(R)-Propranolol as internal standard (IS) were preseparated from interfering components in plasma on a Phenomenex silica column and bevantolol enantiomers and IS were resolved and determined on a Chiralcel OJ-H chiral stationary phase. The two columns were connected by a switching valve equipped with silica precolumn. The Precolumn was used to concentrate bevantolol in the eluent from the achiral column before back flushing onto chiral phase. A detailed validation of the method was performed accordingly to FDA guidelines. For each enantiomer the assay was linear between 20 and 1600 ng/ml. The quantification limits of both bevantolol enantiomers were 20 ng/ml. The intraday variation was between 1.07 and 12.64% in relation to the measured concentration and the interday variation was 0.91 and 11.79%. The method has been applied to the determination of (-)-(S)- and (+)-(R)-bevantolol in plasma from healthy volunteers dosed with racemic bevantolol hydrochloride.  相似文献   

12.
A selective chiral high performance liquid chromatographic (HPLC) method was developed and validated to separate and quantify the enantiomers of a novel anticonvulsant agent, N-(4-chlorophenyl)-1-(4-pyridyl)ethylamine (AAP-Cl), in rat plasma. After extraction of the plasma samples with ethyl acetate, the separation was accomplished by an HPLC system consisting of a Chirex chiral column (250 mm x 4.6 mm i.d.) and a mobile phase of hexane:ethanol:tetrahydrofuran (280:20:40 (v/v)) containing trifluroacetic acid (0.3% (v/v)) and triethylamine (0.018% (v/v)) at a flow rate of 0.8 ml/min with UV detection. Male Sprague-Dawley rats were given (+)-AAP-Cl (10 and 20 mg/kg), (-)-AAP-Cl (10 mg/kg) or the racemic mixture (20 mg/kg) by i.v. bolus injection and serial blood samples were collected at different times after drug administration. (+)-AAP-Cl and (-)-AAP-Cl were separated with a resolution factor, Rs, of at least 1.4, and a separation factor, alpha, greater than 1.09. Linear calibration curves were obtained over the concentration range of 0.5-30 microg/ml in plasma for both (+)-AAP-Cl and (-)-AAP-Cl (R2 > or = 0.996) with a limit of quantitation of 100 ng/ml and the recovery was greater than 80% for both enantiomers. The accuracy and precision for both enantiomers ranged from 96 to 102% (+/-0.2-7%) at upper and lower concentrations. The plasma concentration-time profiles of the enantiomers of AAP-Cl were best described by a two-compartment open model with a mean terminal half-life of about 5h, volume of distribution at steady state of 3 l/kg and clearance of about 0.6l/(hkg) in rats. There was no significant difference between the pharmacokinetic parameters of (+)-AAP-Cl and (-)-AAP-Cl, suggesting that the disposition of AAP-Cl in rats is not enantioselective. In addition, no chiral inversion of (+)-AAP-Cl to (-)-AAP-Cl or vice versa was observed. The results of this investigation have shed some light on the mechanism of action and disposition of AAP-Cl in rats.  相似文献   

13.
An enantioselective assay for S-(-)- and R-(+)-propranolol in transgenic Chinese hamster CHL cell lines, expressing human cytochrome P450 (CYP), was developed. The method involves extraction of propranolol from the S(9) incubates, using S-(+)-propafenone as internal standard, chiral derivatization with 2,3,4,6-tetra-O-beta-D-glucopranosyl isothiocyanate and quantitation by reversed phase high-performance liquid chromatography system with UV detection (lambda=220 nm). A baseline separation of propranolol enantiomers was achieved on a 5-microm reverse-phase ODS column, with a mixture of methanol/water/glacial acetic acid (67:33:0.05, v/v) as mobile phase. The assay is linear from 5 to 500 microM for each enantiomer. The analytical method affords average recoveries of 99.2% and 98.8% for S-(-)- and R-(+)-propranolol, respectively. The limit of quantitation for the method is 5 microM for both S-(-)- and R-(+)-propranolol. The reproducibility of the assay is satisfactory (RSD < 10%). The method allowed study of the depletion of S-(-)- and R-(+)-propranolol in transgenic Chinese hamster CHL cell lines expressing CYP3A4, CYP2C18 and CYP2C9.  相似文献   

14.
A sensitive enantioselective gas chromatographic assay has been developed for amlodipine, 2-[(2-aminoethoxy)-methyl]-4-(2-chlorophenyl)-3-ethoxycarbonyl-5-methoxycarbonyl-6-methyl-1,4-dihydropyridine, a calcium channel blocking therapeutic agent. The assay involves conversion of the (+)-(R)- and (−)-(S)-enantiomers of amlodipine into their acyl derivatives with the chiral reagent (+)-(S)-α-methoxy-α-trifluoromethylphenylacetyl chloride (Mosher's reagent). Peak separation after chromatography of the diastereomers was larger than 85%, and the lower limit of detection in blood plasma was 0.02 ng/ml for each enantiomer. The method has been used for the measurement of amlodipine enantiomers in human, rat and dog plasma, and in various organs of the rat.  相似文献   

15.
A novel and rapid method for the separation and determination of R-(−)- and S-(+)-enantiomers of apomorphine in serum by high-performance liquid chromatography with UV detection is reported. The method involved a solid-phase extraction of the R-(−)- and S-(+)-enantiomers of apomorphine and the internal standard R-(−)-propylnorapomorphine from serum using a C8 Bond-Elut column. The HPLC system consisted of a reversed-phase cellulose-based chiral column (Chiralcel OD-R, 250×4.6 mm I.D.) with a mobile phase of 35:65 (v/v) acetonitrile-0.05 M sodium perchlorate (pH 2.0, adjusted with 60–62% perchloric acid) at a flow-rate of 0.5 ml/min with UV detection at 273 nm. The detection and quantitation limits were 10 ng/ml for each enantiomer using 1 ml of serum. Linear calibration curves from 10 to 1000 ng/ml for both R-(−)- and S-(+)-enantiomers show coefficient of determination of more than 0.9995. Precision calculated as %R.S.D. and accuracy calculated as % error were 0.2–4.7 and 3.1–6.9%, respectively, for the R-(−)-enantiomer and 1.3–4.2 and 0.3–6.8%, respectively, for the S-(+)-enantiomer.  相似文献   

16.
A series of chiral pyridazin-3(2H)-ones was synthesized, separated as pure enantiomers, and evaluated for N-formyl peptide receptor (FPR) agonist activity. Characterization of the purified enantiomers using combined chiral HPLC and chiroptical studies (circular dichroism, allowed unambiguous assignment of the absolute configuration for each pair of enantiomers). Evaluation of the ability of racemic mixtures and purified enantiomers to stimulate intracellular Ca(2+) flux in FPR-transfected HL-60 cells and human neutrophils and to induce β-arrestin recruitment in FPR-transfected CHO-K1 cells showed that many enantiomers were potent agonists, inducing responses in the sub-micromolar to nanomolar range. Furthermore, FPRs exhibited enantiomer selectivity, generally preferring the R-(-)-forms over the S-(+)-enantiomers. Finally, we found that elongation of the carbon chain in the chiral center of the active compounds generally increased biological activity. Thus, these studies provide important new information regarding molecular features involved in FPR ligand preference and report the identification of a novel series of FPR agonists.  相似文献   

17.
A stereospecific high-performance liquid chromatographic (HPLC) method was developed for the quantitation of the enantiomers of venlafaxine, an antidepressant, in dog, rat, and human plasma. The procedure involves derivatization of venlafaxine with the chiral reagent, (+)-S-naproxen chloride, and a postderivatization procedure. The method was linear in the range of 50 to 5,000 ng of each enantiomer per ml of plasma. No interference by endogenous substances or known metabolites of venlafaxine occurred. Studies to characterize the disposition of the enantiomers of venlafaxine were conducted in dog, rat, and human, following oral administration of venlafaxine. The Cmax, area under the curve (AUC) and (S)/(R) concentration ratios of the (R)- and (S)-enantiomers were compared. In rats, the mean plasma ratio of (S)-venlafaxine to that of (R)-venlafaxine over 0.5 to 6.0 h varied from 2.97 to 8.50 with a mean value of 5.51 +/- 2.45. The Cmax, AUC0-infinity, and t 1/2 values of the (R)- and (S)-enantiomers in dogs were not significantly different from one another (P greater than 0.1). The mean ratios [(S)/(R)] of enantiomers of venlafaxine in human over a 2 to 6 h interval ranged from 1.33 to 1.35 with an overall ratio of 1.34 +/- 0.26 (n = 12). These ratios of the enantiomers [(S)/(R)] were not statistically different from unity (P greater than 0.1) indicating that the disposition of venlafaxine enantiomers in humans is not stereoselective and is more similar to that in dogs than that in rats.  相似文献   

18.
Gu X  Wang P  Liu D  Lv C  Lu Y  Zhou Z 《Chirality》2008,20(2):125-129
The stereoselective degradation of the racemic benalaxyl in vegetables such as tomato, tobacco, sugar beet, capsicum, and the soil has been investigated. The two enantiomers of benalaxyl in the matrix were extracted by organic solvent and determined by validated chiral high-performance liquid chromatography with a cellulose-tris-(3, 5-dimethylphenylcarbamate)-based chiral column. Rac-benalaxyl was fortified into the soil and foliar applied to vegetables. The assay method was linear over a range of concentrations (0.5-50 microg ml(-1)) and the mean recoveries in all the samples were more than 70% for the two enantiomers. The limit of detection for both enantiomers was 0.05 microg g(-1). The results in soil showed that R-(-)-enantiomer dissipated faster than S-(+)-enantiomer and the stereoselectivity might be caused by microorganisms. In tomato, tobacco, sugar, beet, and capsicum plants, there was significantly stereoselective metabolism. The preferential absorption and degradation of S-(+)-enantiomer resulted an enrichment of the R-(-)-enantiomer residue in all the vegetables.  相似文献   

19.
An enantioseparation of the antipsychotic drug butaclamol in human plasma by high-performance liquid chromatography (HPLC) with solid phase extraction is presented. The separation was achieved on the vancomycin macrocyclic antibiotic chiral stationary phase (CSP) Chirobiotic V with a polar ionic mobile phase (PIM) consisting of methanol : glacial acetic acid : triethylamine (100:0.2:0.05, v/v/v) at a flow rate of 0.5 ml/min. The detection wavelength was 262 nm. Bond Elut C18 solid phase extraction cartridges were used in the sample preparation of butaclamol samples from plasma. The method was validated over the range of 100-3,000 ng/ml for each enantiomer concentration (R(2) > 0.999). Recoveries for (+)- and (-)-butaclamol were in the range of 94-104% at the 300-2,500 ng/ml level. The method proved to be precise (within-run precision ranged from 1.1-2.6% and between-run precision ranged from 1.9-3.2%) and accurate (within-run accuracies ranged from 1.5-5.8% and between-run accuracies ranged from 2.7-7.7%). The limit of quantitation (LOQ) and limit of detection (LOD) for each enantiomer in human plasma were 100 ng/ml and 50 ng/ml, respectively.  相似文献   

20.
An HPLC method for determining quercetin in human plasma and urine is presented for application to the pharmacokinetic study of rutin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using kaempferol as an internal standard. Solid-phase extraction was performed on an Oasis HLB cartridge (>95% recovery). The HPLC assay was carried out using a Luna ODS-2 column (150 x 2.1 mm I.D., 5 microm particle size). The mobile phase was acetonitrile-10 mM ammonium acetate solution containing 0.3 mM EDTA-glacial acetic acid, 29:70:1 (v/v, pH 3.9) and 26:73:1 (v/v, pH 3.9) for the determination of plasma and urinary quercetin, respectively. The flow-rate was 0.3 ml/min and the detection wavelength was set at 370 nm. Calibration of the overall analytical procedure gave a linear signal (r>0.999) over a concentration range of 4-700 ng/ml of quercetin in plasma and 20-1000 ng/ml of quercetin in urine. The lower limit of quantification was approximately 7 ng/ml of quercetin in plasma and approximately 35 ng/ml in urine. The detection limit (defined at a signal-to-noise ratio of about 3) was approximately 0.35 ng/ml in plasma and urine. A preliminary experiment to investigate the plasma concentration and urinary excretion of quercetin after oral administration of 200 mg of rutin to a healthy volunteer demonstrated that the present method was suitable for determining quercetin in human plasma and urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号