首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The first practical fluorometric assay of plasma 25-hydroxyvitamin D3 (25-OH-D3) and 24R,25-dihydroxyvitamin D3 (24,25-(OH)2D3) is described. The method uses a highly fluorescent dienophile, 4-[2-(6,7-dimethoxy-4-methyl-3-oxo-3,4-dihydroquinoxalyl)ethyl]-1, 2,4- triazoline-3,5-dione (DMEQ-TAD), to fluorescence-label vitamin D. Vitamin D metabolites were roughly purified with a short cartridge column followed by HPLC, labeled with DMEQ-TAD, and the product was analyzed on HPLC. In the assay of 25-OH-D3 the new fluorometric method was compared with the HPLC-uv method and was confirmed to be as accurate and reliable (CV, 4-5%) as the HPLC-uv method. Plasma 24,25-(OH)2D3 was accurately assayed by the HPLC-FL method, where the standard addition method was successfully used to calculate the overall recovery.  相似文献   

2.
为比较外周血T淋巴细胞亚群CD4不同测定方法的差别,以流式细胞术为定量手段,测定了猴外周血中三种不同方法处理后CD4的表达.结果表明:先标后溶法——先用异硫氰荧光素标记的单克隆抗体(FITC-CD4 McAb)标记后,再加入红细胞溶解液溶掉红细胞的处理方法,结果基本等同于传统的淋巴细胞分离法,但样本用量仅为传统方法的1/5,且操作简单.激光共焦显微术的形态学研究也证实:先标后溶法与淋巴细胞分离法相似,其细胞膜表面荧光标记清晰,优于先溶后标法.  相似文献   

3.
A sensitive nonradioactive method for detection of substances interacting with the neuronal nicotinic acetylcholine alpha 7-type receptor (AChR) was proposed. The method uses biotinylated alpha-cobratoxin (Bt-CTX) and is based on the ability of the N-terminal ligand-binding extracellular domain (LBED) of AChR to interact with alpha-cobratoxin (CTX) as does the whole receptor. LBED was produced by heterologic expression of a gene fragment of the alpha 7 subunit of AChR from the rat brain in Escherichia coli cells sorbed on wells of a 96-well plate and incubated with Bt-CTX. The specifically bound Bt-CTX was determined by staining with streptavidin-peroxidase complex. The ability of other compounds to interact with alpha 7-AChR was checked according to the degree with which they inhibit Bt-CTX binding to LBED. Nicotine, carbamylcholine, d-tubocurarin, anabaseine, conotoxin ImI, and neurotoxin II were used as model compounds. The sensitivity of this method was comparable with that of the radioligand method (up to 10 pmol).  相似文献   

4.
During the past decade, evaluation of high-density lipoprotein (HDL) functionality has been well studied for predicting cardiovascular disease (CVD) risk. Cholesterol efflux capacity (CEC) is the strongest candidate as the biomarker out of various HDL antiatherosclerotic functions. However, CEC has not yet been introduced clinically because of several technical issues, including the use of radioactive materials and differentiated cells in the assay. Previously, our laboratory developed a radioisotope- and cell-free CEC assay called the immobilized liposome-bound gel beads (ILGs) method to replace the conventional method. However, the separation process of the supernatant was not suitable for installation in an automatic analyzer. The present study aims to develop a new method that is easier to operate. We assumed that the use of magnetic beads instead of gel beads would enable the skip of the centrifugal process. First, similar to the ILG method, porous magnetic beads were treated with liposomes containing fluorescently labeled cholesterol. Fluorescence was observed inside the magnetic beads, and almost the same amount of liposomes as in the ILG method was immobilized successfully. These immobilized liposome-bound magnetic beads (ILMs) were available for CEC assay when HDL and apolipoprotein B-100-depleted serum (BDS) were used as cholesterol acceptors. The ILM method showed sufficient basic performance and a good correlation with the ILG method. Furthermore, when the CEC of 15 serum samples from healthy subjects was measured, a good correlation between HDL-cholesterol level and the ILG method was confirmed. Thus, it was confirmed that the ILM method was successfully developed and could be automated.  相似文献   

5.
Improvement of the micromethod for the limulus lysate test.   总被引:3,自引:0,他引:3  
Frauch's micro-slide method was improved to facilitate the endpoint-determination of the Limulus test. Two precise observations, by inverted phase contrast microscopy and with a staining procedure, were newly performed as additions to the slide test. The staining procedure was proposed as an improved method for the Limulus test since it is simple and convenient. In the staining method, bromophenol blue (BPB) solution was used as the staining solution. A negative (-), a strong positive (++) and a weak positive reaction (+) were characterized by a "ring" formation, a "cloud-like" spread of gel and a "spot" in the "cloud" respectively. Since the distinction between (-) and (+) reactions was obvious in the proposed method, determination of the endpoint was easier than in the ordinary tube and Frauch's method. The sensitivity of the present method was equal to or higher than that of other methods. Inverted phase contrast microscopy was utilized to confirm the findings obtained by the staining method. The volume of the lysate used in this method was as little as 1/10 of that used in the tube method.  相似文献   

6.
The inhibitory effects of tetrahydrolipstatin (THL) on the hydrolytic activity of human pancreatic lipase (HPL) and T. lanuginosa lipase (TLL) on various lipidic substrates ‘poisoned’ with THL as previously described was studied, using either the pH-stat, monomolecular film or oil drop technique.Prior to adding lipase (method C), an ethanolic solution of THL was injected in a tributyrin (TC4) or a purified soybean oil (PSO) emulsion prepared in a pH-stat vessel. Under these conditions, THL was found to be a potent HPL inhibitor. After being dissolved in the pure triglyceride phase (method D), THL also strongly inhibited HPL. However, with TC4 as substrate TLL was efficiently inhibited by THL only when method C was used and not method D. The very different inhibitory effects on HPL and TLL recorded with method D and PSO as substrate were confirmed using the monomolecular film and oil drop techniques.With a monomolecular film of dicaprin (di-C10) as substrate, 1 molecule of THL embedded in 400 000 molecules of di-C10 sufficed to reduce the HPL activity to half of its initial value.HPL was therefore efficiently inhibited by THL with all the methods and substrates tested here. Paradoxically, TLL was inhibited by THL molecules transiently present in the aqueous phase and not by the THL molecules present at the triglyceride/water interface. It should therefore be stressed that the inhibitory effects of THL on each lipase depend strongly on the method and the substrate used.  相似文献   

7.
Niemann H 《Theriogenology》1985,23(2):369-379
The effects of a one-step addition of 1.4 M glycerol (method A) upon morphological appearance and developmental capacity of frozen/thawed day 7 bovine embryos were investigated and compared to a standard stepwise addition of 1.0 M glycerol (method B). With method A, the percentage of intact embryos (classified as excellent, good and poor) was 95.3% (61 out of 64) without differences between morulae (96.5%) and blastocysts (94.4%). With method B, the percentage of intact embryos was 83.0% (44 out of 53). The percentage was similar for blastocysts (89.2%) and significantly (p < 0.05) lower for morulae (68.8%) when compared to method A. The percentage of embryos with a damaged zona pellucida was considerably increased with method A (26.6%) when compared to method B (13.2%). The proportion of embryos with excluded blastomeres was similar in both methods (21.9% method A, 17.0% method B). With method A, pregnancy rates after nonsurgical transfer were 51.0% (25 out of 49) and were better than with method B (40.5%; 15 out of 37). Embryos with a damaged zona pellucida resulted in a high pregnancy rate of 66.7% (8 out of 12). A pregnancy rate of 52.9% (10 out of 17) was obtained with embryos showing some excluded blastomeres. Thus, a one-step addition of 1.4 M glycerol facilitates and accelerates the process of embryo cryopreservation and is compatible with high pregnancy rates. Damage of the zona pellucida does not impair further development of frozen/thawed bovine embryos provided blastomeres are intact.  相似文献   

8.
The polyaniline (PANi)-Nafion composite film was prepared onto the ceramic plate by the cyclic voltammetry (CV) method with the various cycle numbers. When the PANi-Nafion/Au/ceramic plate with the preparing cycle number of 5 was as working electrode, the cathodic peak current was achieved as 84.0 microA in 60 mg dl(-1) NH4Cl buffer solution. On the other hand, the small cathodic peak currents for buffer solution in the presence of 60 mg dl(-1) LiOH, NaCl and KCl, respectively, were found with the same composite electrode as working electrode. The cathodic peak current decreased from 84.0 to 16.3 microA in the 60 mg dl(-1) NH4Cl buffer solution when the cycle number for preparing PANi-Nafion/Au/ceramic plate composite electrode with the CV method increased from 5 to 15. The enzyme of urease was immobilized onto the PANi-Nafion/Au/ceramic plate composite film by the electrochemical immobilization and the casting methods and used as sensing electrode to detect the concentration of urea in the buffer solution. The sensitivity of composite electrode immobilized with the casting method was greater than that of electrochemical immobilization method. The sensitivity and the detecting limit of the urea sensor were found to be 0.7 and 5.27 microA (mg dl(-1))(-1)cm(-2), as well as 6 and 0.3 mg dl(-1), respectively, when urease was immobilized by glutaraldehyde (GA) cross-linker and Nafion network, respectively.  相似文献   

9.
A novel high-performance liquid chromatography (HPLC) method based on the internal standard method was established for assaying the tumour necrosis factor-α converting enzyme (TACE) activity and matrix metalloprotease-9 (MMP-9) activity, and was used to evaluate the inhibitive effectiveness of inhibitors to TACE and MMP-9. In the assay method for TACE and MMP-9, peptides labelled with the ultraviolet group-Dpa were used as substrates. Alanine-Dpa was synthesised and was used as the internal standard for quantitative analysis. After the peptide substrates were hydrolysed by TACE (MMP-9) for 15 min (25 min) at 37 °C, the amount of remaining substrates were determined by reversed-phased HPLC with UV detection at 353 nm. The relative peak area of the substrate was linearly dependent on the substrate concentration. This method was then applied to determine the 50% inhibitory concentration (IC??) of GM6001 and inhibitor A for both TACE and MMP-9.  相似文献   

10.
A quantitative method for the determination of total tiopronin (TP) in human plasma was developed by liquid chromatography with electrospray ionisation (ESI) mass spectrometric detection. After reduction with tris (2-carboxy-ethyl) phosphine (TCEP) and derivatization with methyl acrylate (MA) for the thiol group of TP, plasma samples were processed successively by deproteinization and solid phase extraction. N-acetyl-l-cysteine (NAC) was selected as internal standard undergoing the same treatment as TP. The method was validated that it could meet the need of biological analysis. The lower limit of quantitation (LLOQ) of TP in plasma was 0.02microg/mL. Finally, the method was successfully applied to a pharmacokinetic study in 20 healthy Chinese male volunteers after an oral dose of 200mg TP tablets.  相似文献   

11.
A rapid, sensitive and accurate high-performance liquid chromatographic method with UV detection was developed and validated for the quantification of gabapentin in human plasma. Gabapentin was quantified using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene following protein precipitation of plasma with acetonitrile. Amlodipine was used as internal standard. The chromatographic separation was carried out on a Nova-Pak C(18) column using a mixture of 50 mM NaH(2)PO(4) (pH=2.5)-acetonitrile (30:70, v/v) as mobile phase with UV detection at 360 nm. The flow rate was set at 1.5 ml/min. The method was linear over the range of 0.05-5 microg/ml of gabapentin in plasma (r(2)>0.999). The within-day and between-day precision values were in the range of 2-5%. The limit of quantification of the method was 0.05 microg/ml. The method was successfully used to study the pharmacokinetics of gabapentin in healthy volunteers.  相似文献   

12.
A novel method based on immuno-chemiluminescence and image analysis using charge coupled device (CCD) for the qualitative detection of methyl parathion (MP) with high sensitivity (up to 10 ppt) is described. MP antibodies raised in poultry were used as a biological sensing element for the recognition of MP present in the sample. The immuno-reactor column was prepared by packing in a glass capillary column (150 microl capacity) MP antibodies immobilized on Sepharose CL-4B through periodate oxidation method. Chemiluminescence principle was used for the detection of the pesticide. Light images generated during the chemiluminescence reaction were captured by a CCD camera and further processed for image intensity, which was correlated with pesticide concentrations. K(3)Fe(CN)(6) was used as a light enhancer to obtain detectable light images. Different parameters including concentrations of K(3)Fe(CN)(6), luminol, urea H(2)O(2), antibody, addition sequence of reactants and incubation time to obtain best images were optimized. The results obtained by image analysis method showed very good correlation with that of competitive ELISA for methyl parathion detection. Competitive ELISA method was used as a reference to compare the results obtained by CCD imaging.  相似文献   

13.
In this study, a modified method of the conventional RNA dot-blot hybridization was established, by replacing ~(32)p labels with CY5 labels and replacing nylon membranes with positive-charged glass slides, for detecting plant RNA viruses and a viroid. The modified RNA dot-blot hybridization method was named glass slide hybridization. The optimum efficiency of RNA binding onto the surfaces of activated glass slide was achieved using aminosilane-coated glass slide as a solid matrix and 5×saline sodium citrate (SSC) as a spotting solution. Using a CY5-labeled DNA probe prepared through PCR amplification, the optimized glass slide hybridization could detect as little as 1.71 pg of tobacco mosaic virus (TMV) RNA. The sensitivity of the modified method was four times that of dot-blot hybridization on nylon membrane with a ~(32)P-labeled probe. The absence of false positive within the genus Potyvirus [potato virus A, potato virus Y (PVY) and zucchini yellow mosaic virus] showed that this method was highly specific. Furthermore, potato spindle tuber viroid (PSTVd) was also detected specifically. A test of 40 field potato samples showed that this method was equivalent to the conventional dot-blot hybridization for detecting PVY and PSTVd. To our knowledge, this is the first report of using dot-blot hybridization on glass slides with fluorescent-labeled probes for detecting plant RNA viruses and a viroid.  相似文献   

14.
A fast, partly recursive deterministic method for calculating Identity-by-Descent (IBD) probabilities was developed with the objective of using IBD in Quantitative Trait Locus (QTL) mapping. The method combined a recursive method for a single marker locus with a method to estimate IBD between sibs using multiple markers. Simulated data was used to compare the deterministic method developed in the present paper with a stochastic method (LOKI) for precision in estimating IBD probabilities and performance in the task of QTL detection with the variance component approach. This comparison was made in a variety of situations by varying family size and degree of polymorphism among marker loci. The following were observed for the deterministic method relative to MCMC: (i) it was an order of magnitude faster; (ii) its estimates of IBD probabilities were found to agree closely, even though it does not extract information when haplotypes are not known with certainty; (iii) the shape of the profile for the QTL test statistic as a function of location was similar, although the magnitude of the test statistic was slightly smaller; and (iv) the estimates of QTL variance was similar. It was concluded that the method proposed provided a rapid means of calculating the IBD matrix with only a small loss in precision, making it an attractive alternative to the use of stochastic MCMC methods. Furthermore, developments in marker technology providing denser maps would enhance the relative advantage of this method.  相似文献   

15.
The ultrastructure of anionic sites in the lamina rara externa (LRE) of rat glomerular basement membrane (GBM) was studied in three dimensions by a quick-freezing and deep-etching method using polyethyleneimine (PEI) as a cationic tracer. Results were compared with those obtained with conventional ultrathin sections examined by transmission electron microscopy. Examination with the quick-freezing and deep-etching method was done without (group 1) or with (group 2) contrasting/fixation with a phosphotungstic acid and glutaraldehyde mixture and post-fixation with osmium tetroxide, which were necessary for visualization of PEI particles by conventional ultrathin sections. Using the quick-freezing and deep-etching method without following contrasting/fixation and post-fixation (group 1), many PEI particles were observed to decorate around fibrils, which radiated perpendicularly from the lamina densa to connect with the podocyte cell membrane. The arrangement of PEI particles was not as regular as that previously reported using conventional ultrathin sections. In contrast, the tissue that was studied with quick-freezing and deep-etching followed by contrasting/fixation and post-fixation (group 2) showed a shrunken appearance. The arrangement of PEI particles was regular (about 20 particles/1000 nm of LRE) as that previously observed using conventional ultrathin sections. However, the number of PEI particles on the LRE was markedly decreased and interruption of decorated fibrils was prominent, as compared with group 1. Ultrastructural examination using conventional ultrathin sections with contrasting/fixation and post-fixation (group 3) demonstrated PEI particles on the LRE in reasonable amounts (18-21 particles/1000 nm of LRE) with fairly regular interspacing (45-65 nm) as reported previously.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
A technique to determine friction at the fingertips   总被引:2,自引:0,他引:2  
This article proposes a technique to calculate the coefficient of friction for the fingertip- object interface. Twelve subjects (6 males and 6 females) participated in two experiments. During the first experiment (the imposed displacement method), a 3-D force sensor was moved horizontally while the subjects applied a specified normal force (4 N, 8 N, 12 N) on the surface of a sensor covered with different materials (sandpaper, cotton, rayon, polyester, and silk).The normal force and the tangential force (i.e., the force due to the sensor motion) were recorded. The coefficient of friction (mu(d)) was calculated as the ratio between the tangential force and the normal force. In the second experiment (the beginning slip method), a small instrumented object was gripped between the index finger and the thumb, held stationary in the air, and then allowed to drop. The weight (200 g, 500 g, and 1,000 g) and the surface (sandpaper, cotton, rayon, polyester, and silk) in contact with the digits varied across trials. The same sensor as in the first experiment was used to record the normal force (in a horizontal direction) and the tangential force (in the vertical direction). The slip force (i.e., the minimal normal force or grip force necessary to prevent slipping) was estimated as the force at the moment when the object just began to slip. The coefficient of friction was calculated as the ratio between the tangential force and the slip force. The results show that (1) the imposed displacement method is reliable; (2) except sandpaper, for all other materials the coefficient of friction did not depend on the normal force; (3) the skin-sandpaper coefficient of friction was the highest mu(d) =0.96+/-0.09 (for 4-N normal force) and the skin-rayon rayon coefficient of friction was the smallest mu(d) =0.36+/-0.10; (4) no significant difference between the coefficients of friction determined with the imposed displacement method and the beginning slip method was observed. We view the imposed displacement technique as having an advantage as compared with the beginning slip method, which is more cumbersome (e.g., dropped object should be protected from impacts) and prone to subjective errors owing to the uncertainty in determining the instance of the slip initiation (i.e., impeding sliding).  相似文献   

17.
A method for enzyme immunoassay of thyroid-stimulating hormone (TSH) is described, TSH was conjugated with horseradish peroxidase according to periodate oxidation method. Separation of the bound and free was obtained by double-antibody solid-phase technique using Sepharose 4B-anti-rabbit immunogiobulin G (IgG)-geat IgG. The fluorescence reaction using tyramine and hydrogen peroxide as substrates was used for the determination of enzyme activity in order to increase the sensitivity of enzyme immunoassay. The standard curve for serum TSH was satisfactory to recognize TSH concentrations as 0.06 μU/tube. TSH values obtained by this method correlated well with those obtained by radioimmunoassay (r, 0.96). The coefficients of variation were 1.8 to 5.3% (within assay) and 5.1 to 10.5% (between assay). The method is about equal to radioimmunoassay with respect to sensitivity. Since it requires minimal equipment and is less expensive than radioimmunoassay, it is possible to perform routine assays even in laboratories with limited facilities.  相似文献   

18.
Summary It was demonstrated that microwave energy used simultaneously in combination with low concentrations of glutaraldehyde (0.05%) and formaldehyde (2.0%) rapidly preserved light microscopic histology and excellent fine structural details, as well as a variety of cytoplasmic and membrane-bound antigens. Specimen blocks up to 1 cm3 can be fixed in as brief a time as 26 ms using a specially designed microwave device (ultrafast microwave fixation method). The fast microwave fixation method, using a commercially available device, was successfully used to preserve granule-bound rat mast cell chymase which was subsequently detected by a postembedding immunogold procedure. Control of the following parameters is important to the microwave fixation method: (1) specimens with one dimension less than 1 cm; (2) irradiation temperatures lower than 50°C; (3) irradiation times less than 50 s; (4) immediate replacement of the postirradiation solution with cold storage buffer; (5) fixing the specimen within 15 min after it is removed from its blood supply.  相似文献   

19.
A method based on Rimini test for aliphatic amines was studied and developed for quantitative estimation of aliphatic primary amines. The method involves action of the amine with acetone to form schiff base which complexes with sodium nitroprusside to give violet colour. The absorption maximum in the visible range of the spectrum, for the reaction mixture was found to be 550 nm. The pH (8–11) and reaction time scan for the assay were optimized. A linear relation of concentration (0.2–3 mg/mL) of amine against absorbance at 550 nm was established. Interference due to other reaction components was negligible (±0.02 mg/mL) as compared to the sample in buffer. 1, 3-dimethyl butylamine was used as the model amine and the method was applied to other amines; it was observed that when electron-withdrawing substituents are present in the molecule the reaction is retarded, as the incubation time was longer. This method is useful for estimation of aliphatic primary amine in biological samples.  相似文献   

20.
A rapid method for the quantification of amiodarone and desethylamiodarone in animal plasma using high-performance liquid chromatography combined with UV detection (HPLC-UV) is presented. The sample preparation includes a simple deproteinisation step with acetonitrile. In addition, a sensitive method for the quantification of amiodarone and desethylamiodarone in horse plasma and urine using high-performance liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is described. The sample preparation includes a solid-phase extraction (SPE) with a SCX column. Tamoxifen is used as an internal standard for both chromatographic methods. Chromatographic separation is achieved on an ODS Hypersil column using isocratic elution with 0.01% diethylamine and acetonitrile as mobile phase for the HPLC-UV method and with 0.1% formic acid and acetonitrile as mobile phase for the LC-MS/MS method. For the HPLC-UV method, good linearity was observed in the range 0-5 microg ml(-1), and in the range 0-1 microg ml(-1) for the LC-MS/MS method. The limit of quantification (LOQ) was set at 50 and 5 ng ml(-1) for the HPLC-UV method and the LC-MS/MS method, respectively. For the UV method, the limit of detection (LOD) was 15 and 10 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs of the LC-MS/MS method in plasma were much lower, i.e. 0.10 and 0.04 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs obtained for the urine samples were 0.16 and 0.09 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The methods were shown to be of use in horses. The rapid HPLC-UV method was used for therapeutic drug monitoring after amiodarone treatment, while the LC-MS/MS method showed its applicability for single dose pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号