首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
To avoid the influence of pre-analytical steps, this study was performed using sterile blood spiked with defined loads of microorganisms as inoculum. Time-to-Detection (TTD) was evaluated for the most frequently encountered bacteria comparing two commercially available blood culture systems, BD BACTEC 9240 (Becton Dickinson) and BacT/ALERT (Organon Teknika). The effect of the most widely used antibiotics on TTD was evaluated on both systems. TTD was measured with antibiotics at their trough and at increasing concentrations. The results show that the BACTEC PLUS system recovers more pathogens with shorter time to detection than the BacT/ALERT FAN system when beta-lactam antibiotics (Ampicillin, Cefotaxime) are present at their respective trough concentration corresponding to parenteral therapy. The two systems seem to be equally efficient when Gentamicin, Ciprofloxacin and Trimethoprim/sulfamethoxazole are used; in the case of Vancomycin, BACTEC seems more effective than BacT/ALERT.  相似文献   

2.
目的评价全自动血培养仪BacT/Aler3D的临床应用情况。方法对BacT/Aler3D全自动血培养仪检测的1853份标本,其检出的阳性率、病原菌种类及阳性检出时间进行了评估。结果1853份血培养分离出病原菌189株,阳性率为10.2%,分离出病原菌23种,最快检出时间为2h,24h以内阳性率为68.5%,48h内阳性率为87.3%,72h以内阳性率为92.3%。结论BacT/Aler3D全自动血培养仪提高血培养的阳性率,检出的细菌种类多,污染机会少,缩短阳性检出时间,而且操作简便,结果快速、准确。  相似文献   

3.
Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (FA) and anaerobic (FN) [corrected] media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in 5% sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four (2.6%) of the 904 subcultures grew on the subculture media. The majority (83.3%) of these were determined to be gram-positive microorganisms. Fourteen (58.3%) were coagulase-negative staphylococci, two (8.3%) were Bacillus spp., one (4.2%) was Staphylococcus aureus, and one (4.2%) was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two (8.3%) vials. Gram-negative microorganisms comprised 12.5% of the subcultures, of which two (8.3%) were found to be Pseudomonas aeruginosa, and one (4.2%) was Pseudomonas fluorescens. The other isolate (4.2%) was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.  相似文献   

4.
We compared the performance of the BacT/ALERT automated blood culture system with real-time, quantitative volatile organic compound (VOC) detection by selected ion flow tube-mass spectrometry (SIFT-MS). Blood samples from healthy donors were artificially infected with 5 or 100 CFU of organisms commonly causing bacteremia. Positive results by SIFT-MS analysis of headspace gases were recorded for 53/60 (88.3%) bottles at 8h, and 58/60 (96.6%) bottles at 24 h. We conclude that SIFT-MS is a sensitive method for the detection of microbial VOCs. Furthermore, profiles of the VOCs detected may allow simultaneous identification of infecting organisms.  相似文献   

5.
6.
The efficacy of the acridine orange (AO), gram (G), and methylene blue (MB) microscopic procedures was analyzed using positive blood cultures monitored by a radiometric procedure (Bactec) in children. Sixty-eight positive cultures included the following isolates: Haemophilus influenzae type b, Neisseria meningitidis, Streptococcus pneumoniae, Enterobacteriaceae, Staphylococcus aureus, Candida spp., and seven other pathogens. The MB stain yielded the highest detection rate, 99%, in comparison with 94 and 93% for the AO and G stains, respectively. Since the MB stain yielded comparable results to the AO procedure with no requirement for a fluorescent microscope, the former method is recommended for confirming the presence and initial characterization of microorganisms in blood cultures monitored by Bactec from children.  相似文献   

7.
Automated hematology analyzers (analyzers) can provide complete blood counts and white blood cell (WBC) differentials in clinical laboratories and alert users to the presence of quantitative and qualitative cell abnormalities through cautionary flags. In this study, we applied analyzers to the screening of apoptotic cells in peripheral blood and examined the triggering capacity of cautionary flags to detect apoptotic cell populations. EDTA-anticoagulated fresh peripheral blood from patients with acute infectious mononucleosis containing atypical lymphocytes comprising 12.3 +/- 4. 0% of WBC was applied to a Beckman-Coulter MAXM A/L Retic (MAXM) analyzer. The lymphocyte cluster spread upward in VOLUME/DF1 scattergrams and the threshold lines between lymphocyte and monocyte clusters shifted upward. Flags for the number and percentage of lymphocytes, variant lymphocytes, and blast cells were generally present for samples containing atypical lymphocytes. After the blood from acute infectious mononucleosis patients was incubated for 4 h at 37 degrees C, peripheral blood smears revealed the presence of morphologically apoptotic cells comprising 9.0 +/- 4.2% of WBC and a comparable reduction of lymphocytes. On the MAXM analyzer, the apoptotic lymphocyte cluster appeared under the lymphocyte cluster in VOLUME/DF1 scattergrams. However, no specific flag was present to alert users to the presence of the apoptotic lymphocyte cluster. We conclude that visual inspection of scattergrams generated by the MAXM analyzer can be useful for the detection of apoptotic lymphocytes in peripheral blood. Cytometry (Comm. Clin. Cytometry) 42:209-214, 2000. Published 2000 Wiley-Liss, Inc.  相似文献   

8.
This study evaluates the effect of preincubation on delayed-entry samples for fastidious organisms including the HACEK group, Streptococcus species, Neisseria meningitidis, Haemophilus species and Corynebacterium species for the BacT/ALERT 3D System (bioMérieux) using the FA (aerobic) medium.Bottles were inoculated with two different concentrations (0.5 McFarland and a 1:100,000 dilution) of each organism and either loaded into the system immediately or stored at 4 °C, room temperature (RT) or 37 °C for 24 hours (h) prior to loading.The detection rate (DR) was 92.5% for bottles loaded immediately for both concentrations with a mean time to detection (TTD) of 26.7 h (standard deviation (SD): 14.7 h) for the low concentration and 9.21 h (SD: 5.3 h) for the high concentration. Preincubation at 4 °C did not affect the DR for either of the two concentrations in comparison to no preincubation. The DR at RT was 90.0% for the low concentration and 83.6% for the high concentration. At 37 °C the DR was 76.3% and 66.3% for the low and the high concentrations respectively. The average TTD was inversely correlated with the preincubation temperature. An incubation of four days was sufficient, with the exception of Eikenella corrodens and Gemella sanguinis. The serotype of Streptococcus pneumoniae or Neisseria meningitidis did not influence the TTD. Kingella kingae remained undetected.For the retrieval of the above mentioned bacteria we recommend storage of bottles at room temperature. In case of erroneous storage at 37 °C subcultivation is advisable.All cases with a negative result on day four should be reevaluated and eventually new material for alternative diagnostic procedures should be retrieved.  相似文献   

9.
10.
AIMS: To compare the detection capabilities of the non-radiometric MGIT (Mycobacteria Growth Indicator Tubes) and radiometric BACTEC 460TB culture systems (Becton Dickinson, Cowley, Oxford, UK) for recovering Mycobacterium avium subsp. paratuberculosis from milk. METHODS AND RESULTS: Ultra heat treated (UHT) milk samples spiked with different levels of M. paratuberculosis (10-107 cells ml-1) were inoculated into MGIT and BACTEC media (containing recommended supplements) with and without prior chemical decontamination of the milk samples with 0.75% (w/v) cetylpyridinium chloride for 5 h. Time for the detection of growth in days was recorded for each culture system, and a M. paratuberculosis count for each milk sample was calculated from BACTEC readings using a published formula. Correlation between MGIT and BACTEC detection times was 0.6983. Both culture systems were capable of detecting 10-100 M. paratuberculosis cells ml-1 in milk within 30-40 days when no decontamination treatment was applied, but only 102-103 cells ml-1 or greater when chemical decontamination was applied before culture. CONCLUSIONS, SIGNIFICANCE AND IMPACT OF STUDY: The non-radiometric MGIT system could be substituted for the radiometric BACTEC system for the culture of M. paratuberculosis from milk without loss of detection sensitivity. Chemical decontamination before culture caused a significant reduction in numbers of viable M. paratuberculosis in all spiked milk samples resulting in decreased detection capability for both culture systems.  相似文献   

11.
12.
Daidzin, a soy-derived biologically active natural product, has been reported to inhibit mitochondrial aldehyde dehydrogenase and suppress ethanol intake. This paper describes a method for the determination of daidzin in rat blood. After administration of daidzin, blood samples were periodically collected from awake, freely moving animals by a Culex automated blood sampler. Daidzin was extracted from 50 microl of diluted blood (blood and saline at a ratio of 1:1) with ethyl acetate. Chromatographic separation was achieved within 12 min using a microbore C(18) (100 x 1.0 mm) 3 microm column with a mobile phase containing 20 mM sodium acetate, 0.25 mM EDTA, pH 4.3, 4% methanol and 11% acetonitrile at a flow-rate of 90 microl/min. Detection was attained using a four-channel electrochemical detector with glassy carbon electrodes using oxidation potentials of +1100, 950, 850, 750 mV vs. Ag/AgCl. The limit of detection for daidzin in rat plasma was 5 ng/ml at a signal-to-noise ratio of 3:1. The extraction recovery of daidzin from rat plasma was over 74%. Linearity was obtained for the range of 25-1000 ng/ml. The intra- and inter-assay precisions were in the ranges of 2.7-6.6 and 1.9-3.7%, respectively. This method is suitable to routine in vivo monitoring of daidzin in rat plasma.  相似文献   

13.
Mice were trained on a variety of odor detection and discrimination tasks in 100- or 200-trial sessions using a go, no-go discrete trials operant conditioning procedure. Odors, presented for 1 s on each trial, were generated by an air dilution olfactometer (for threshold tests) and an easily constructed eight-channel liquid dilution unit (for two- and multiple-odor discrimination tasks). Mice rapidly acquired the operant task and demonstrated excellent stimulus control by odor vapors. Their absolute detection threshold for ethyl acetate was similar to that obtained with rats using similar methods. They readily acquired four separate two-odor discrimination tasks and continued to perform well when all eight odors were presented in random order in the same session and when reinforcement probability for correct responding was decreased from 1 to 0.5. Memory for these eight odors, assessed under extinction after a 32 day rest period, was essentially perfect. Time spent sampling the odor on S+ and S- trials was highly correlated with response accuracy. When accuracy was at chance levels (e.g. initial trials on a novel task), stimulus sampling time on both S+ and S- trials was approximately 0.5-0.7 s. As response accuracy increased, sampling time on S+ trials tended to increase and remain higher than sampling time on S- trials.  相似文献   

14.
As the number of single-nucleotide polymorphism (SNP) screening and other mutation scanning studies have increased explosively, following the development of high-throughput instrumentation, it becomes even more important to have sufficient template DNA. The source of DNA is often limited, especially in epidemiological studies, which require many samples as well as enough DNA to perform numerous SNP screenings or mutation scannings. Therefore, the aim is to solve the problem of stock DNA limitation. This need has been an important reason for the development of whole genome amplification (WGA) methods. Several systems are based on Phi29 polymerase multiple displacement amplification (MDA) or on DNA fragmentation (OmniPlex). Using TaqMan SNP genotyping assays, we have tested four WGA systems -- AmpliQ Genomic Amplifier Kit, GenomiPhi, Repli-g, and GenomePlex -- on DNA extracted from Guthrie cards to evaluate the amplification bias, concordance- and call rates, cost efficiency, and flexibility. All systems successfully amplified picograms of DNA from Guthrie cards to micrograms of product without loss of heterozygosity and with minimal allelic bias. A modified AmpliQ set up was chosen for further evaluation. In all, 2,000 SNP genotyping results from amplified and nonamplified samples were compared and the concordance rates between the samples were 99.7%. The call rate using the TaqMan system was 99.8%. DNA extracted from Guthrie cards and amplified with one of the four evaluated WGA systems is applicable in epidemiological genetic screenings. System choice should be based on requirements for system flexibility, product yield, and use in subsequent analysis.  相似文献   

15.
《Fly》2013,7(3):205-210
A fundamental phenotypic trait in Drosophila melanogaster is the speed of movement. Its quantification in response to environmental and experimental factors is highly useful for behavioral and neurological studies. Quantifying this behavioral characteristic in freely moving flies is difficult, and many current systems are limited to evaluating the speed of movement of one fly at a time or rely on expensive, time-consuming methods. Here, we present a novel signal processing method of quantifying the speed of multiple flies using a system with automatic behavior detection and analysis that we previously developed to quantify general activity. By evaluating the shape of the signal wave from recordings of a live and simulated single fly, a metric for speed of movement was found. The feasibility of using this metric to estimate the speed of movement in a population of flies was then confirmed by evaluating recordings taken from populations of flies maintained at two different temperatures. The results were consistent with those reported in the literature. This method provides an automated way of measuring speed of locomotion in a fly population, which will further quantify fly behavioral responses to the environment.  相似文献   

16.
A preliminary evaluation of an automated direct epifluorescent filter technique instrument, COBRA, showed that it enumerated rapidly bacteria in cultures, raw milk, meat and fish. The correlation coefficients of regression lines with corresponding pour plate counts were 0·99 (pure cultures), 0·81 (raw milk) and 0·91 (raw meat and fish), respectively. The system was simple to use, one operator could process > 100 samples/h and results were available in < 1 h.  相似文献   

17.
18.
19.
A liquid chromatography method with multi-channel electrochemical detection was developed for the determination of epigallocatechin gallate (EGCG) in rat plasma. After administration of EGCG, blood samples were periodically collected by Culex (an automated blood sampling robot). EGCG was extracted from 50 μl of diluted blood (blood and saline at a ratio of 1:1) with ethyl acetate. Chromatographic separation was achieved within 10 min using a C8 (150×4.6 mm) 5 μm column with a mobile phase containing 20 mM sodium monochloroacetate, pH 2.8 and 12% acetonitrile at a flow-rate of 1.2 ml/min. A four-channel detector with glassy carbon electrodes was used with applied potentials of +700, 600, 500, 400 mV vs. Ag/AgCl. The limit of detection was 2 ng/ml at a signal-to-noise ratio of 3:1 and the limit of quantitation was 5 ng/ml. The calibration curve was linear over the range of 5–800 ng/ml. The intra- and inter-assay precisions were in the range of 1.3–4.5% and 2.2–4.4%, respectively. Using this method it was possible to determine plasma concentration following a single dose of EGCG to rats with good accuracy and precision. Thus the pharmacokinetic properties of EGCG in rats can be examined for intravenous, intraperitoneal and oral dosing.  相似文献   

20.
Microarray technology is currently one of the most widely-used technologies in biology. Many studies focus on inferring the function of an unknown gene from its co-expressed genes. Here, we are able to show that there are two types of positional artifacts in microarray data introducing spurious correlations between genes. First, we find that genes that are close on the microarray chips tend to have higher correlations between their expression profiles. We call this the 'chip artifact'. Our calculations suggest that the carry-over during the printing process is one of the major sources of this type of artifact, which is later confirmed by our experiments. Based on our experiments, the measured intensity of a microarray spot contains 0.1% (for fully-hybridized spots) to 93% (for un-hybridized ones) of noise resulting from this artifact. Secondly, we, for the first time, show that genes that are close on the microtiter plates in microarray experiments also tend to have higher correlations. We call this the 'plate artifact'. Both types of artifacts exist with different severity in all cDNA microarray experiments that we analyzed. Therefore, we develop an automated web tool-COP (COrrelations by Positional artifacts) to detect these artifacts in microarray experiments. COP has been integrated with the microarray data normalization tool, ExpressYourself, which is available at http://bioinfo.mbb.yale.edu/ExpressYourself/. Together, the two can eliminate most of the common noises in microarray data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏