首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A quantitative gas chromatographic—mass spectrometric assay has been developed for the determination of ethambutol (EMB) in human plasma. Plasma samples were taken from a patient after oral administration of EMB (with proven tuberculosis infection). Deuterated EMB and a non-deuterated analogue of EMB were synthesized and used as internal standards in this procedure; both gave excellent agreement in the analysis. The derivatizing agent used was trifluoroacetic anhydride (TFAA) and quantitative derivatization was complete in one hour, forming EMB-(TFA). Selective ion monitoring was utilized to monitor the gas chromatographic effluent. Ions were generated by electron impact at 70 eV. The limit of detection was 36 ng EMB per ml plasma. This method is compared with the electron-capture gas chromatographic procedure of Lee and Benet.  相似文献   

2.
A simple column chromatographic method for determination of ethambutol (EMB) in pharmaceutical preparations containing EMB in combination with other anti-TB drugs is presented. The method involved extraction of EMB into an organic solvent, followed by basification and column chromatographic separation on Amberlite CG 50 (100-200 mesh) and elution with suitable eluants and estimation at a wavelength of 270 nm. The assay was linear from 25 to 400 microg/ml. The relative standard deviations of intra and inter day assays were lower than 5%. Ethambutol was recovered from human urine quantitatively and stable for a period of at least one week in urine stored at -20 degrees C.  相似文献   

3.

Background

The purpose of this study was to evaluate the performance of the BACTEC MGIT 960 (M960) system compared with the proportion method (PM) on Löwenstein-Jensen (L-J) medium in a peripheral laboratory in China for the testing of Mycobacterium tuberculosis (MTB) susceptibility to streptomycin (SM), isoniazid (INH) rifampicin (RIF) and ethambutol (EMB) a combination known as SIRE.

Methods

The susceptibility of 205 clinical isolates of MTB to SM, INH, RIF and EMB was performed with the M960 system. The drugs were tested at the following concentrations: 1.0 µg/ml for SM, 0.1 µg/ml for INH, 1.0 µg/ml for RIF, and 5.0 µg/ml for EMB. The results were compared with those obtained by the L-J PM. The L-J PM at an arbiter site was used to resolve any discordant results.

Results

The overall consistency was 96.6% and concordance values were 95.6% for SM, 97.6% for INH, 98.0% for RIF and 95.1% for EMB. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the M960 system for PM (the standard method) was 95.6%, 97.3%, 96.2% and 96.9% respectively, and the sensitivity were 93.3% for SM, 96.9% for INH, 97.4% for RIF and 94.6% for EMB, the specificity were 96.9% for SM, 98.2% for INH, 98.4% for RIF and 95.5% for EMB, the PPV were 94.6% for SM, 97.9% for INH, 97.4% for RIF and 94.6% for EMB, the NPV were 96.2% for SM, 97.3% for INH, 98.4% for RIF and 95.5% for EMB. The turnaround time with the M960 system (median 8.0 days, ranged from 5 to 14 days) was significantly shorter than that with the PM (28 days or 42 days).

Conclusion

There was a substantial degree of agreement between the two methods. The M960 system was a reliable and rapid method for SIRE susceptibility testing of tuberculosis in China.  相似文献   

4.
Two high-performance liquid chromatographic (HPLC) methods are described for determination of (±)-ethopropazine (ET) in rat plasma. After deproteination and liquid–liquid extraction, assay of (±)-ET was performed using either a C18 column (non-stereospecific assay) or an (α-R-naphthyl)ethylurea column (stereospecific assay). The UV detection was at 250 nm. Mean recovery was >85%. Both assays demonstrated excellent linear relationships between peak height ratios and plasma concentrations; quantitation limits were ≤25 ng/ml, based on 100 μl rat plasma. Accuracy and precision were <17% with both methods. Both methods were applied successfully to the measurement of ET plasma concentrations in rats given the drug intravenously.  相似文献   

5.
This study describes an expedient assay for the analysis of the asthma medication, montelukast sodium (Singulair, MK-0476), in human plasma samples. After a simple extraction of the plasma, the drug and internal standard, quinine bisulfate, were measured by HPLC. The chromatographic system consisted of a single pump, a refrigerated autosampler, a C8 4-μm particle size radial compression cartridge at 40°C and a fluorescence detector with the excitation and emission wavelengths set at 350 and 400 nm, respectively. The mobile phase which was delivered at 1.0 ml/min, was prepared by adding 200 ml of 0.025 M sodium acetate, pH adjusted to 4.0 with acetic acid, to 800 ml of acetonitrile, with 50 μl triethylamine. With a run time of only 10 min per sample, this assay had an overall recovery of >97% with a detection limit of 1 ng/ml. The inter- and intra-run relative standard deviations at 0.05, 0.2 and 1.0 μg/ml were all <9.2%, while the analytical recovery at the same concentrations were within 7.7% of the amount added.  相似文献   

6.
A reversed-phase high-performance liquid chromatographic assay (HPLC) was utilized for monitoring xanomeline (LY246708/NNC 11–0232) and a metabolite, desmethylxanomeline, in human plasma. Xanomeline, desmethylxanomeline and internal standard were extracted from plasma with hexane at basic pH. The organic solvent extract was evaporated to dryness with nitrogen and the dried residue was reconstituted with 0.2 M HCl-methanol (50:50, v/v). A Zorbax CN 150 × 4.6 mm I.D., 5-μm column and mobile phase consisting of 0.5% (5 ml/l) triethylamine (TEA) adjusted to pH 3.0 with concentrated orthophosphoric acid-tetrahydrofuran (THF) (70:30, v/v) produced consistent resolution of analytes from endogenous co-extracted plasma components. Column effluent was monitored at 296 nm/0.008 a.u.f.s. and the assay limit of quantification was 1.5 ng/ml. A linear response of 1.5 to 20 ng/ml was sufficient to monitor plasma drug/metabolite concentrations during clinical trials. HPLC assay validation as well as routine assay quality control (QC) samples indicated assay precision/accuracy was better than ±15%.  相似文献   

7.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

8.
A method is described for the determination of the two enantiomers of mirtazapine in human blood plasma by high-performance liquid chromatography. Measurements were performed on drug free plasma spiked with mirtazapine and used to prepare and validate standard curves. Levels of enantiomers of mirtazapine were also measured in patients being treated for depression with racemic mirtazapine. Mirtazapine was separated from plasma by solid-phase extraction using CERTIFY columns. Chromatographic separation was achieved using a Chiralpak AD column and pre-column and compounds were detected by their absorption at 290 nm. Imipramine was used as an internal standard. The assay was validated for each analyte in the concentration range 10–100 ng/ml. The coefficient of variance was 16% and 5.5% for(+)-mirtazapine for 10 and 100 ng/ml control specimens respectively and 15% and 7.3% for mirtazapine for 10 and 100 ng/ml control specimens respectively. This assay is appropriate for use in the clinical range. The range of plasma mirtazapine concentrations from eleven patients taking daily doses of 30–45 mg of racemate was <5 to 69 ng/ml for (+)-mirtazapine and 13–88 ng/ml for (−)-mirtazapine for blood specimens collected 10–17.5 h after taking the dose.  相似文献   

9.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (Cipralan TM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile---phosphate buffer (0.015 mol/1, pH 6.0) (80:20). A 10-μ ion-exchange (sulfonate) column was used with acetonitrile—phosphate buffer (0.015 mol/1, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard.The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10–1000 ng/ml and 50–5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects.  相似文献   

10.
A reversed-phase high-performance liquid chromatographic assay for the simultaneous determination of phenytoin and fosphenytoin, a prodrug for phenytoin, in human plasma and plasma ultrafiltrate is described. For plasma, the method involves simple extraction of drugs with diethyl ether and evaporation of solvent, followed by injection of the reconstituted sample onto a reversed-phase C18 column. Plasma ultrafiltrate is injected directly into the HPLC column. Compounds are eluted using an ion-pair mobile phase containing 20% acetonitrile. The eluent is monitored by UV absorbance at 210 nm. The fosphenytoin standard curves are linear in the concentration range 0.4 to 400 μg/ml for plasma and 0.03 to 80 μg/ml for ultrafiltrate. Phenytoin standard curves are linear from 0.08 to 40 μg/ml for plasma and from 0.02 to 5.0 μg/ml for ultrafiltrate. No interferences with the assay procedure were found in drug-free blank plasma or plasma ultrafiltrate. Relative standard deviation for replicate plasma or ultrafiltrate samples was less than 5% at concentrations above the limit of quantitation for both within- and between-run calculations.  相似文献   

11.
A sensitive, specific and stability-indicating high-performance liquid chromatographic (HPLC) assay, involving pre-column derivatization and solid-phase extraction (SPE), was developed and validated for the quantitation of busulfan (BU) in aqueous and plasma samples. The linearity of the assay was in the concentration ranges of 0.15–10 μg/ml and 0.15–3 μg/ml for aqueous and plasma samples, respectively. The within-day and between-day variations were 2.90 and 3.31%, respectively, for the aqueous samples, and 9.24 and 14.56%, respectively, for the plasma samples. The overall recovery, derivatization yield and SPE efficiency of BU from plasma samples were 82.03, 108.01 and 86.69%, respectively. Forced degraded samples, either in highly acidic, neutral or basic medium, produced no interfering peaks in the chromatogram. The reported assay requires only 0.2 ml of plasma for the analysis, and its sensitivity is 150 ng/ml by monitoring samples at a wavelength of 254 nm, sufficient to study the plasma pharmacokinetics of BU in rats after a clinically relevant oral dose. Moreover, the sensitivity of the assay can be significantly increased to 30 ng/ml by monitoring samples at a wavelength of 278 nm. The applications of the assay were demonstrated with BU solubility measurements in two aqueous systems and with plasma samples from a Sprague–Dawley rat for an in vivo pharmacokinetic study. In addition, the assay has been employed in the development of a patented intravenous formulation, and in evaluations of stability, preclinical pharmacokinetics in rats and dogs, and clinical phase I trial of the formulation. The assay is readily adaptable to clinical therapeutic drug monitoring.  相似文献   

12.

Background

The emergence of resistant tuberculosis (TB) is a major setback to the global control of the disease as the treatment of such resistance is complex and expensive. Use of direct detection of mutations by molecular methods could facilitate rapid diagnosis of resistance to offset diagnostic delays. We evaluated the performance of the Genotype MTBDRsl (Hain Life Sciences) for the detection of second line resistant TB directly from stored smear positive sputum sediments.

Methodology/Principal Findings

The assay showed a diverse range of sensitivity and specificity, 91.26% [95% CI, 84–96] and 95.5% [95% CI, 87–99] for FQ (PPV ∼97% & NPV ∼ 87.67%), 56.19% [95%CI, 46–66] and 81% [95%CI, 66–91] for EMB (PPV ∼ 88.06% & NPV ∼ 43.21%) and 100% for SLD. Diagnostic accuracy for FQ, SLD and EMB was 94%, 100% and 63.51%, respectively. 1.17% (2/170) were heteroresistance strains, where the heteroresistance was linked to rrs gene. A varying rate of validity was observed 100% (170/170) for FQ, 94.11% (160/170) for EMB, 88.23% (150/170) for SLD.

Conclusions/Significance

Genotype MTBDRsl is simple, rapid, economical assay that can be used to detect commonly known resistance associated with Fluoroquinolone, second line injectable drugs and ethambutol. The assay detects the targeted resistance in less time as compared to phenotypic DST. But due to low NPV to FQ (88%) and EMB (43.21%), the assay results must be interpreted in coordination with the phenotypic DST.  相似文献   

13.
Three high-performance liquid chromatographic methods are described for the detection of the novel antifolate anticancer drug (6R)-5,10-dideaza-5,6,7,8-tetrahydrofolate (lometrexol): one with fluorometric detection and two with detection by UV absorbance. An assay for plasma lometrexol using UV detection (288 nm) and reversed-phase chromatography was developed, with a quantitation limit of 0.2 μg/ml and linearity up to 10 μg/ml. This assay was modified for measurement of lometrexol in urine, with a quantitation limit of 2 μg/ml and linearity up to 25 μg/ml. An alternative assay for plasma lometrexol using derivatization and fluorescence detection (excitation at 325 nm, emission at 450 nm) was also developed, which proved twenty-fold more sensitive (quantitation limit of 10 ng/ml) than the UV assay, and which was linear up to 250 ng/ml. The fluoremetric method requires sample oxidation with manganese dioxide prior to analysis, and uses ion-pair chromatography with tetramethylammonium hydrogensulphate as an ion-pair reagent. All assays use a similar preliminary solid-phase extraction method (recovery as assessed by UV absorption >73%), with C10-desmethylene lometrexol added for internal standardisation. Each assay is highly reproducible (inter-assay precision in each assay is <10%). Applicability of the fluorescence-based assay to lometrexol in plasma and the UV-based assay lometrexol in urine is demonstrated by pharmacokinetic studies in patients treated as part of a Phase I clinical evaluation of the drug.  相似文献   

14.
A selective high-performance liquid chromatographic (HPLC) assay for a sigma receptor antagonist, DuP 734 (I), in rat plasma has been developed. Compound I and internal standard, XC031 (I.S.), were first extracted from plasma into an ethyl acetate—toluene mixture (3:7, v/v) and then back-extracted into freshly prepared phosphoric acid (0.03 M). Separation of I and I.S. with no interference from endogenous substances was achieved on a reversed-phase octyl column and detection was by UV at 229 nm. The mobile phase consisted of acetonitrile—glacial acetic acid—triethylamine—0.05 M ammonium acetate (670:4:2:2000, v/v). Using 0.5 ml of rat plasma for extraction, the limit of quantitation was 43 ng/ml and the assay was linear from 43 to 8536 ng/ml. The intra- and inter-day coefficients of variation ranged from 0.7 to 3.0%, and from 1.4 to 14.5%, respectively, over the entire concentration range. The accuracy was within 16.1% of the spiked concentrations. I was stable in frozen plasma at −20°C for at least 68 days.  相似文献   

15.
A sensitive high-performance liquid chromatographic method for the determination of paromomycin in human plasma and urine was developed. Paromomycin was quantitated following pre-column derivatization with 2,4-dinitrofluorobenzene (DNFB). The chromatographic separation was carried out on a C18 column at 50°C using a mobile phase consisting of 64% methanol in water adjusted to pH 3.0 with phosphoric acid. The eluents were monitored by UV detection at 350 nm. The linearity of response for paromomycin was demonstrated at concentrations from 0.5 to 50 μg/ml in plasma and 1 to 50 μg/ml in urine. The relative standard deviation of the assay procedure is less than 5%.  相似文献   

16.
A high-performance liquid chromatographic procedure was developed for the determination of caffeine in various biologic fluids and coffee. A reversed-phase column and UV detection at 254 nm were used to obtain a sensitivity of 0.1 μg/ml caffeine in serum and saliva using a sample volume of 0.1 ml. Caffeine metabolites and commonly ingested xanthines do not interfere with the assay. The within-day coefficients of variation were 9.8 and 9.9% at plasma caffeine concentrations of 2 and 10 μg/ml, respectively. The day-to-day coefficients of variation were 6.8 and 6.6% at plasma caffeine concentrations of 2 and 10 μg/ml, respectively. Serum and saliva caffeine concentrations were determined following a single oral dose of coffee and an intravenous infusion of caffeine in one subject. Computer estimates of caffeine pharmacokinetic parameters in one subject are in excellent agreement with previously published values.  相似文献   

17.
An improved HPLC method using a silica gel column with fluorescence detection (excitation at 300 nm and emission at 365 nm) was developed for the determination of sulpiride concentrations in plasma. Analysis of sulpiride in plasma samples was simplified by a one-step liquid–liquid extraction after alkaline treatment of only 1 ml of plasma. The low limit of quantitation was 20 ng/ml with a coefficient of variation of less than 20%. A linear range was found from 20 to 1500 ng/ml. This HPLC method was validated with the precision for inter-day and intra-day runs being 0.36–8.01% and 0.29–5.25%, respectively, and the accuracy (standard deviation of mean, SD) for inter-day and intra-day runs being −1.58 to 5.02% and −2.14 to 5.21%, respectively. Bioequivalence of the two products was evaluated in 12 normal healthy male volunteers in a single-dose, two-period, two-sequence, two-treatment cross-over study. Sulpiride plasma concentrations were analyzed with this validated HPLC method. Results demonstrated that the two tablet formulations of sulpiride appear to be bioequivalent.  相似文献   

18.
This paper describes a high-performance liquid chromatographic method for the assay of quinfamide and its main metabolite, 1-(dichloroacetyl)-1,2,3,4,-tetrahydro-6-quinolinol, in plasma, urine and feces. It requires 1 ml of biological fluid, an extraction using Sep-Pack cartridges and acetonitrile for drug elution. Analysis was performed on a CN column (5 μm) using water–acetonitrile–methanol (40:50:10) as a mobile phase at 269 nm. Results showed that the assay was linear in the range between 0.08 and 2.0 μg/ml. The limit of quantitation was 0.08 μg/ml. Maximum assay coefficient of variation was 14%. Recovery obtained in plasma, urine and feces ranged from 82% to 98%.  相似文献   

19.
A high-performance liquid chromatographic method using column switching was applied to the direct determination of two local anaesthetics, ropivacaine and bupivacaine, in human plasma. The method is intended to be used in a combined LC—GC system; here only the LC-part is described. After addition of internal standard, the samples were filtered and directly injected into a semipermeable surface (SPS) pre-column where the analytes were strongly retained and separated from many endogenous compounds by a short washing step. The retained analytes were transferred by a buffered methanol phase from the pre-column into a carbonaceous HPLC column and they were detected by UV detection at 254 nm. The SPS pre-column could withstand numerous (> 200) direct injections of plasma samples (10 μl). The method has a detection limit of 8.2 ng and requires a total assay time of 15 min per plasma sample. Quantitative recoveries were obtained over the range 3.3–114 μg/ml with inter-day precisions of 1.6–5.2% (C.V.).  相似文献   

20.
A reliable high-performance liquid chromatographic method has been validated for determination of gallamine in rat plasma, muscle tissue and microdialysate samples. A C18 reversed-phase column with mobile phase of methanol and water containing 12.5 mM tetrabutyl ammonium (TBA) hydrogen sulphate (22:78, v/v) was used. The flow-rate was 1 ml/min with UV detection at 229 nm. Sample preparation involved protein precipitation with acetonitrile for plasma and muscle tissue homogenate samples. Microdialysate samples were injected into the HPLC system without any sample preparation. Intra-day and inter-day accuracy and precision of the assay were <13%. The limit of quantification was 1 μg/ml for plasma, 1.6 μg/g for muscle tissue and 0.5 μg/ml for microdialysate samples. The assay was applied successfully to analysis of samples obtained from a pharmacokinetic study in rats using the microdialysis technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号