首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The ability to exercise precise spatial and temporal control over cell-surface interactions is an important prerequisite to the assembly of multi-cellular constructs serving as in vitro mimics of native tissues. In this study, photolithography and wet etching techniques were used to fabricate individually addressable indium tin oxide (ITO) electrodes on glass substrates. The glass substrates containing ITO microelectrodes were modified with poly(ethylene glycol) (PEG) silane to make them protein and cell resistive. Presence of insulating PEG molecules on the electrode surface was verified by cyclic voltammetry employing potassium ferricyanide as a redox reporter molecule. Importantly, the application of reductive potential caused desorption of the PEG layer, resulting in regeneration of the conductive electrode surface and appearance of typical ferricyanide redox peaks. Application of reductive potential also corresponded to switching of ITO electrode properties from cell non-adhesive to cell-adhesive. Electrochemical stripping of PEG-silane layer from ITO microelectrodes allowed for cell adhesion to take place in a spatially defined fashion, with cellular patterns corresponding closely to electrode patterns. Micropatterning of several cell types was demonstrated on these substrates. In the future, the control of the biointerfacial properties afforded by this method will allow to engineer cellular microenvironments through the assembly of three or more cell types into a precise geometric configuration on an optically transparent substrate.  相似文献   

2.
A sulfite oxidase (SO(x)) (EC 1.8.3.1) purified from Syzygium cumini leaves was immobilized onto prussian blue nanoparticles/polypyrrole composite (PBNPs/PPY) electrodeposited onto the surface of indium tin oxide (ITO) electrode. An amperometric sulfite biosensor was fabricated using SO(x)/PBNPs/PPY/ITO electrode as working electrode, Ag/AgCl as standard and Pt wire as auxiliary electrode connected through a potentiostat. The working electrode was characterized by Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS) before and after immobilization of SO(x). The biosensor showed optimum response within 2s, when operated at 20mVs(-1) in 0.1M Tris-HCl buffer, pH 8.5 and at 35°C. Linear range and minimum detection limit were 0.5-1000μM and 0.12μM (S/N=3) respectively. There was good correlation (r=0.99) between red wine samples sulfite value by standard DTNB method and the present method. The sensor was evaluated with 97% recovery of added sulfite in red wine samples and 2.2% and 4.3% within and between batch coefficients of variation respectively. The sensor was employed for determination of sulfite level in red and white wine samples. The enzyme electrode was used 200 times over a period of 3 months when stored at 4°C.  相似文献   

3.
A high density microelectrode array biosensor was developed for the detection of Escherichia coli O157:H7. The biosensor was fabricated from (100) silicon with a 2 microm layer of thermal oxide as an insulating layer, an active area of 9.6 mm2 and consists of an interdigitated gold electrode array. The sensor surface was functionalised for bacterial detection using heterobifunctional crosslinkers and immobilised polyclonal antibodies to create a biological sensing surface. Bacteria suspended in solution became attached to the immobilised antibodies when the biosensor was tested in liquid samples. The change in impedance caused by the bacteria was measured over a frequency range of 100 Hz-10 M Hz. The biosensor was evaluated for E. coli O157:H7 detection in pure culture and inoculated food samples. The biosensor was able to discriminate between cellular concentrations of 10(4)-10(7)CFU/mL and has applications in detecting pathogens in food samples.  相似文献   

4.
Cerium oxide nanorods (CeO(2) NRs) were synthesized without templates through a low cost and simple non-isothermal precipitation method. The structure and morphology of CeO(2) NRs were characterized by X-ray diffraction and transmission electron microscopy. The CeO(2) NRs films, deposited on indium tin oxide (ITO)-coated glass substrates through electrophoretic deposition, were used for the immobilization of glucose oxidase (GOx). Field emission scanning electron microscopy, Fourier transform infrared spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy were used to characterize the CeO(2) NRs/ITO and GOx/CeO(2) NRs/ITO electrodes. The GOx/CeO(2) NRs/ITO electrode exhibits a linear range for the detection of glucose from 2 to 26 mM (correlation coefficient: 0.99) at 1-2s response time. Biosensor sensitivity is 0.165 μA mM(-1) cm(-2) with 100 μM detection limit. The anti-interference ability of the biosensor was also examined. The mediator-less application of CeO(2) NRs for glucose sensing was demonstrated.  相似文献   

5.
Electrochemical impedance spectroscopy (EIS) was used to monitor the growth of mammalian cancer cells and evaluate the cytotoxicity of chemicals using Fe(CN)6(3-/4-) as a redox probe. Cancer cells, the human hepatocarcinoma cell line (BEL7404), were grown on optically transparent indium tin oxide (ITO) semiconductor slides, which were used as the working electrodes in electrochemical experiments. Attachment and proliferation of cancer cells on ITO surfaces resulted in increase of electron-transfer resistance (R(et)) between the redox probe of Fe(CN)6(3-/4-) in electrolyte solution and ITO electrode surface. For cytotoxicity assessment, cells grown on ITO substrates were further cultured in the presence of different cytotoxicants and electrochemical impedance measurements were carried out at different time intervals. Gemcitabine, a promising antineoplastic drug showing activity against a wide spectrum of human solid tumors, was selected as a model for long-term cytotoxicity effect study, whereas mercury chloride represented a model for acute toxicants. The inhibitions of gemcitabine and mercury chloride on the viability and proliferation of BEL7404 cells were observed from the electrochemical impedance experiments, and the different action modes were discriminated. Additionally, microscope images were also used to observe the effects of these two chemicals on the morphology of the cells. General consistency has been found between the electrochemical impedance response and the morphological observation. Such an impedance method provides a simple and inexpensive way for in vitro assessment of chemical cytotoxicity.  相似文献   

6.
An immunosensor with rapid and ultrasensitive response for vascular endothelial growth factor (VEGF) has been built up with 4-aminothiophenol (4-ATP) onto the gold surfaces. Quantitative analysis of VEGF was performed by recording the impedance changing of the gold electrode surface by binding of VEGF. The human vascular endothelial growth factor receptor 1 (VEGF-R1, Flt-1) was used as a biorecognition element for the first time in the literature. VEGF-R1 was covalently immobilized via 4-ATP self-assembled monolayer formed on gold thin film covered surface. Construction of the biosensor was carefully characterised by the techniques such as electrochemistry and electrochemical impedance spectroscopy. In order to characterize impedance data, Kramers–Kronig transform was performed on the experimental impedance data. The limit of detection of the immunosensor for qualitative detection was 100 pg/mL while the LOD for quantitative detection could down to 100 pg/mL by using the VEGF-R1 based biosensor. Finally, artificial serum samples spiked with VEGF was analyzed by the proposed immunosensor to investigate useful of the biosensor for early biomarker diagnosis.  相似文献   

7.
We present highly transparent and conductive silver thin films in a thermally evaporated dielectric/metal/dielectric (DMD) multilayer architecture as top electrode for efficient small molecule organic solar cells. DMD electrodes are frequently used for optoelectronic devices and exhibit excellent optical and electrical properties. Here, we show that ultrathin seed layers such as calcium, aluminum, and gold of only 1 nm thickness strongly influence the morphology of the subsequently deposited silver layer used as electrode. The wetting of silver on the substrate is significantly improved with increasing surface energy of the seed material resulting in enhanced optical and electrical properties. Typically thermally evaporated silver on a dielectric material forms rough and granular layers which are not closed and not conductive below thicknesses of 10 nm. With gold acting as seed layer, the silver electrode forms a continuous, smooth, conductive layer down to a silver thickness of 3 nm. At 7 nm silver thickness such an electrode exhibits a sheet resistance of 19 Ω/□ and a peak transmittance of 83% at 580 nm wavelength, both superior compared to silver electrodes without seed layer and even to indium tin oxide (ITO). Top‐illuminated solar cells using gold/silver double layer electrodes achieve power conversion efficiencies of 4.7%, which is equal to 4.6% observed in bottom‐illuminated reference devices employing conventional ITO. The top electrodes investigated here exhibit promising properties for semitransparent solar cells or devices fabricated on opaque substrates.  相似文献   

8.
A novel disposable biosensor based on direct electron transfer of superoxide dismutase (SOD) was fabricated for the determination of superoxide anion. The biosensor was constructed by electrodeposition of gold nanoparticles (GNPs) on the indium tin oxide (ITO) electrode and then immobilization of SOD in silica sol–gel (SG) network in the presence of cysteine on GNPs/ITO modified electrode surface. The distribution of GNPs on ITO electrode surface was examined by scanning electron microscopy (SEM). The immobilized SOD exhibited high catalytical activity towards superoxide anion. Parameters affecting the performance of the biosensor were also investigated. A linear calibration curve was obtained over the range from 0.08 to 0.64 μM with a correlation coefficient of 0.9937. The resulted biosensors were demonstrated to possess striking analytical properties for superoxide anion determination, such as high sensitivity, good accuracy, and long-term stability. It provides a promising platform for the fabrication of disposable biosensors.  相似文献   

9.
Lin J  Qu W  Zhang S 《Analytical biochemistry》2007,360(2):288-293
Indium tin oxide (ITO) electrode is used to fabricate a novel disposable biosensor combined with flow injection analysis for the rapid determination of H2O2. The biosensor is prepared by entrapping horseradish peroxidase (HRP) enzyme in colloidal gold nanoparticle-modified chitosan membrane (Au-chitosan) to modify the ITO electrode. The biosensor is characterized by scanning electron microscope, atomic force microscope, and electrochemical methods. Parameters affecting the performance of the biosensor, including concentrations of o-phenylenediamine (OPD) and pH of substrate solution, were optimized. Under the optimal experimental conditions, H2O2 could be determined in the linear calibration range from 0.01 to 0.5 mM with a correlation coefficient of 0.997 (n=8). The amperometric response of the biosensor did not show an obvious decrease after the substrates were injected continuously 34 times into the flow cell. The prepared biosensor not only is economic and disposable, due to the low-cost ITO film electrode obtained from industrial mass production, but also is capable with good detection precision, acceptable accuracy, and storage stability for the fabrication in batch.  相似文献   

10.
A biosensor for the serum cytokine, interleukin-12 (IL-12), based upon a label-free electrochemical impedance spectroscopy monitoring is described. Overexpression of IL-12 has been correlated to the diagnosis of multiple sclerosis (MS). The prototype biosensor was fabricated on a disposable gold-coated silver ribbon electrode by immobilizing anti-IL-12 monoclonal antibodies (mAbs) onto the surface of the electrode. This technique was advantageous as the silver electrodes provided a more rigid and conductive substrate than thin gold foil electrodes and helped in obtaining more reproducible data when used with the electrode holder. Results indicate that IL-12 can be detected at physiological levels, <100 fM with p<0.05 in a label-free and real-time manner. The cost-effective approach described here can be used for diagnosis of diseases (like MS) with known biomarkers in body fluids and for monitoring physiological levels of biomolecules with healthcare, food, and environmental relevance.  相似文献   

11.
The long-term stability of sensing interfaces is an important issue in biosensor fabrication. A novel stable gold nanoparticle (AuNP)-modified glassy carbon (GC) electrode interface (GC-Ph-AuNP)-based biosensor for detecting carcinoembryonic antigen (CEA) was developed. GC electrodes were modified with 1,4-phenylenediamine to form a stable layer, and then AuNPs were bound onto the GC electrodes through CAu bonds. Anti-CEA was directly adsorbed on AuNPs fixed on the GC electrode. The linear range of the immunosensor was from 10 fg to 100 ng mL(-1) with a detection limit of 3 fg mL(-1) (S/N=3). The current of the immunosensor was increased by 4% after one month. The GC-Ph-AuNP immunosensor showed high sensitivity, a wide linear range, low detection limit, and good selectivity and stability. The immobilization method of the immunosensor could be widely applied to construct other immunosensors.  相似文献   

12.
The development of neuron-microelectrode interfaces (neurochips) is highly desirable for the non-invasive recording of the cellular response to neuroactive drugs as well as the electrical stimulation of nervous tissue by implantable electrodes. A prerequisite for neuron-to-electrode signal transmission (NEST) is the formation of synapse-like contacts between the neuronal cell and the conductive surface of a microelectrode array. We attempted synapse formation by neuronal differentiation of rat pheochromocytoma cells (PC12) and blastocyst-derived murine embryonic stem cells (ES-J1) on interdigitated microelectrode arrays that were made of gold (Au), platinum (Pt), or indium tin oxide (ITO). PC12 or ES cells were in vitro differentiated by incubation with nerve growth factor (NGF) and forskolin, or by serum deprivation and treatment with basic fibroblast growth factor (FGF-2), respectively. On top of ITO electrodes, the neuronal cells extended extremely long processes that terminated in pili-like contact structures, which is typical for growth cone formation. ES cells differentiated into neurons as verified by immunofluorescence staining of MAP-2 and developed synapse-like junctions with the ITO electrode surface as indicated by synaptophysin staining. Differentiated PC12 and ES cells showed bona fide morphological characteristics of synaptic growth cones that were unprecedented in tissue culture. Cones formed by PC12 cells could be stimulated with KCI and carbachol as shown by uptake of FM1-43, a fluorescent marker for synaptic vesicle formation. In contrast to Electrical Cell Impedance Spectroscopy (ECIS) recordings, AC impedance spectrometry with differentiated PC12 cells settled on interdigitated microelectrode arrays revealed lower AC impedance than that with undifferentiated cells, indicating that the complex impedance is dependent on ion fluxes at the neuron-to-electrode contact surface.  相似文献   

13.
Silane nanolayers deposited from the vapor phase onto indium‐tin oxide (ITO) coated glass are shown to be an effective means of tuning the work function and stabilizing the surface of this complex ternary oxide. Using this approach a pair of model hole‐extracting electrodes have been developed to investigate how the performance of bi‐layer organic photovoltaics is impacted by built‐in positive space charge in the critical region close to the hole‐extracting electrode. The magnitude and spatial distribution of positive space charge resulting from ground‐state electron transfer from the donor layer to the ITO electrode upon contact formation, is derived from direct measurements of the interfacial energetics using the Kelvin probe technique. This judiciously designed experiment shows that it is unnecessary to engineer the work function of the hole‐extracting electrode to match the ionization potential of the donor layer, rather only to ensure that the former exceeds the latter, thus simplifying an important aspect of device design. In addition, it is shown that silane nanolayers at the ITO electrode surface are remarkably effective at retarding device degradation under continuous illumination.  相似文献   

14.
The design and development of a screen printed carbon electrode (SPCE) on a polyvinyl chloride substrate as a disposable sensor is described. Six configurations were designed on silk screen frames. The SPCEs were printed with four inks: silver ink as the conducting track, carbon ink as the working and counter electrodes, silver/silver chloride ink as the reference electrode and insulating ink as the insulator layer. Selection of the best configuration was done by comparing slopes from the calibration plots generated by the cyclic voltammograms at 10, 20 and 30 mM K(3)Fe(CN)(6) for each configuration. The electrodes with similar configurations gave similar slopes. The 5th configuration was the best electrode that gave the highest slope. Modifying the best SPCE configuration for use as a biosensor, horseradish peroxidase (HRP) was selected as a biomaterial bound with gold nanoparticles (AuNP) in the matrix of chitosan (HRP/AuNP/CHIT). Biosensors of HRP/SPCE, HRP/CHIT/SPCE and HRP/AuNP/CHIT/SPCE were used in the amperometric detection of H(2)O(2) in a solution of 0.1M citrate buffer, pH 6.5, by applying a potential of -0.4V at the working electrode. All the biosensors showed an immediate response to H(2)O(2). The effect of HRP/AuNP incorporated with CHIT (HRP/AuNP/CHIT/SPCE) yielded the highest performance. The amperometric response of HRP/AuNP/CHIT/SPCE retained over 95% of the initial current of the 1st day up to 30 days of storage at 4 degrees C. The biosensor showed a linear range of 0.01-11.3mM H(2)O(2), with a detection limit of 0.65 microM H(2)O(2) (S/N=3). The low detection limit, long storage life and wide linear range of this biosensor make it advantageous in many applications, including bioreactors and biosensors.  相似文献   

15.
We study the origin of the improvement of the power conversion efficiency (PCE) of inverted organic solar cells when an interfacial insulating organic layer of polyoxyethylene tridecyl ether (PTE) is introduced between the indium tin oxide (ITO) bottom electrode and the TiOx interfacial layer. XPS and UPS measurements are used to investigate the energy level alignment at the interfaces within the ITO/TiOx and ITO/PTE/TiOx structures and to identify any effects due to chemical interaction and interfacial dipoles. Scanning electron microscopy studies show that the surface structure of the TiOx layer is affected, when it is coated on top of the PTE layer. Surface contact angle measurements show that the incorporated interfacial layer of PTE is more hydrophilic than ITO and thus PTE modified TiOx becomes more hydrophilic. This, in combination with the surface gaps of the PTE interfacial layer, is likely to lead to changed wetting and hydrolysis properties of TiOx when coated on ITO/PTE than on ITO alone. The different TiOx layer quality is reflected in improved electron selectivity, leading to enhanced fill factor, reduced parasitic resistance effects and higher power conversion efficiency for inverted solar cells with a PTE interfacial layer between ITO and TiOx.  相似文献   

16.
A disposable pseudo-mediatorless amperometric biosensor has been fabricated for the determination of hydrogen peroxide (H2O2). In the current study, an indium-tin oxide (ITO) electrode was modified with thiol functional group by (3-mercaptopropyl)trimethoxysilane. The stable nano-Au-SH monolayer (AuS) was then prepared through covalent linking of gold nanoparticles and thiol groups on the surface of the ITO. The horseradish peroxidase (HRP) and tetramethyl benzidine (TMB) were finally coentrapped by the colloidal gold nanoparticles. The immobilized TMB was used as an electron transfer mediator that displayed a surface-controlled electrode process at a scan rate of less than 50mV/s. The biosensor was characterized by photometric and electrochemical measurements. The results showed that the prepared AuS monolayer not only could steadily immobilize HRP but also could efficiently retain HRP bioactivity. Parameters affecting the performance of the biosensor, including the concentrations of the immobilized TMB and HRP, the pH value, and the reaction temperature, were optimized. Under the optimized experimental conditions, H(2)O(2) could be determined in a linear calibration range from 0.005 to 1.5mM with a correlation coefficient of 0.998 (n=14) and a detection limit of 1microM at a signal/noise ratio of 3. The proposed method provides a new alternative to develop low-cost biosensors by using ITO film electrodes from industrial mass production.  相似文献   

17.
Based on electrogenerated chemiluminescence (ECL), a novel method for fabrication of alcohol dehydrogenase (ADH) biosensor by self-assembling ADH to Ru(bpy)(3)(2+)-AuNPs aggregates (Ru-AuNPs) on indium tin oxide (ITO) electrode surface has been developed. Positively charged Ru(bpy)(3)(2+) could be immobilized stably on the electrode surface with negatively charged AuNPs in the form of aggregate via electrostatic interaction. On the other hand, AuNPs are favourable candidates for the immobilization of enzymes because amine groups and cysteine residues in the enzymes are known to bind strongly with AuNPs. Moreover, AuNPs can act as tiny conduction centers to facilitate the transfer of electrons. Such biosensor combined enzymatic selectivity with the sensitivity of ECL detection for quantification of enzyme substrate, and it displayed wide linear range, high sensitivity and good stability.  相似文献   

18.
An impedance biosensor based on interdigitated array microelectrode (IDAM) coupled with magnetic nanoparticle-antibody conjugates (MNAC) was developed and evaluated for rapid and specific detection of E. coli O157:H7 in ground beef samples. MNAC were prepared by immobilizing biotin-labeled polyclonal goat anti-E. coli antibodies onto streptavidin-coated magnetic nanoparticles, which were used to separate and concentrate E. coli O157:H7 from ground beef samples. Magnitude of impedance and phase angle were measured in a frequency range of 10 Hz to 1 MHz in the presence of 0.1M mannitol solution. The lowest detection limits of this biosensor for detection of E. coli O157:H7 in pure culture and ground beef samples were 7.4 x 10(4) and 8.0 x 10(5)CFU ml(-1), respectively. The regression equation for the normalized impedance change (NIC) versus E. coli O157:H7 concentration (N) in ground beef samples was NIC=15.55 N-71.04 with R(2)=0.95. Sensitivity of the impedance biosensor was improved by 35% by concentrating bacterial cells attached to MNAC in the active layer of IDAM above the surface of electrodes with the help of a magnetic field. Based on equivalent circuit analysis, it was observed that bulk resistance and double layer capacitance were responsible for the impedance change caused by the presence of E. coli O157:H7 on the surface of IDAM. Surface immobilization techniques, redox probes, or sample incubation were not used in this impedance biosensor. The total detection time from sampling to measurement was 35 min.  相似文献   

19.
Electric Cell-substrate Impedance Sensing (ECIS) is an in vitro impedance measuring system to quantify the behavior of cells within adherent cell layers. To this end, cells are grown in special culture chambers on top of opposing, circular gold electrodes. A constant small alternating current is applied between the electrodes and the potential across is measured. The insulating properties of the cell membrane create a resistance towards the electrical current flow resulting in an increased electrical potential between the electrodes. Measuring cellular impedance in this manner allows the automated study of cell attachment, growth, morphology, function, and motility. Although the ECIS measurement itself is straightforward and easy to learn, the underlying theory is complex and selection of the right settings and correct analysis and interpretation of the data is not self-evident. Yet, a clear protocol describing the individual steps from the experimental design to preparation, realization, and analysis of the experiment is not available. In this article the basic measurement principle as well as possible applications, experimental considerations, advantages and limitations of the ECIS system are discussed. A guide is provided for the study of cell attachment, spreading and proliferation; quantification of cell behavior in a confluent layer, with regard to barrier function, cell motility, quality of cell-cell and cell-substrate adhesions; and quantification of wound healing and cellular responses to vasoactive stimuli. Representative results are discussed based on human microvascular (MVEC) and human umbilical vein endothelial cells (HUVEC), but are applicable to all adherent growing cells.  相似文献   

20.
The microscopic surface molecular structures and macroscopic electrochemical impedance properties of the epoxysilane monolayer and anti-Escherichia coli antibody layer on an indium-tin oxide (ITO) electrode surface were studied in this paper. Characterization of stepwise changes in microscopic features of the surfaces and electrochemical properties upon the formation of each layer were carried out using both atomic force microscopy (AFM) and electrochemical impedance spectroscopy in the presence of [Fe(CN)6](3-/4-) as a redox couple. AFM images of the self-assembled monolayer (SAM) evidenced the dense, complete, and homogeneous morphology of the epoxysilane monolayer on the ITO surface. The uniformity of the epoxysilane SAM allowed antibodies to attach to the epoxy surface groups of the silanes in a similarly uniform fashion. The effects of epoxysilane monolayer and the antibody layer on the electrochemical properties of the electrode were quantitatively analyzed in terms of double layer capacitance, electron transfer resistance, Warburg impedance and solution resistance using Randles model as the equivalent circuit. It was demonstrated that the epoxysilane monolayer and the antibody layer act as barriers for the electron transfer between the electrode surface and the redox species in the solution, resulting in most significant increases in the electron transfer resistance compared to all the electric elements. Immunoreaction with E. coli O157:H7 cells demonstrated specific recognition of the immobilized anti-E. coli antibodies as evidenced by AFM imaging and impedance spectroscopy. It was found that the binding of E. coli cells mainly affected the electron transfer resistance and Warburg impedance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号