首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We present a simple and novel assay—employing a universal molecular beacon (MB) in the presence of Hg2+—for the detection of single nucleotide polymorphisms (SNPs) based on Hg2+–DNA complexes inducing a conformational change in the MB. The MB (T7-MB) contains a 19-mer loop and a stem of a pair of seven thymidine (T) bases, a carboxyfluorescein (FAM) unit at the 5′-end, and a 4-([4-(dimethylamino)phenyl]azo)benzoic acid (DABCYL) unit at the 3′-end. Upon formation of Hg2+–T7-MB complexes through T–Hg2+–T bonding, the conformation of T7-MB changes from a random coil to a folded structure, leading to a decreased distance between the FAM and DABCYL units and, hence, increased efficiency of fluorescence resonance energy transfer (FRET) between the FAM and DABCYL units, resulting in decreased fluorescence intensity of the MB. In the presence of complementary DNA, double-stranded DNA complexes form (instead of the Hg2+–T7-MB complexes), with FRET between the FAM and DABCYL units occurring to a lesser extent than in the folded structure. Under the optimal conditions (20 nM T7-MB, 20 mM NaCl, 1.0 μM Hg2+, 5.0 mM phosphate buffer solution, pH 7.4), the linear plot of the fluorescence intensity against the concentration of perfectly matched DNA was linear over the range 2–30 nM (R2 = 0.991), with a limit of detection of 0.5 nM at a signal-to-noise ratio of 3. This new probe provides higher selectivity toward DNA than that exhibited by conventional MBs.  相似文献   

2.
Kinetic methods for accurate determination of nortriptyline hydrochloride have been described. The methods are based on the oxidation of nortriptyline hydrochloride with KMnO4 in acidic and basic media. In acidic medium, the decrease in absorbance at 525.5 nm and in basic medium, the increase in absorbance at 608.5 nm were measured as a function of time. The variables affecting the reactions were carefully investigated and optimised. Kinetic models such as initial rate, rate constant, variable time and fixed time were employed to construct the calibration curves. The initial rate and fixed time methods were selected for quantification of nortriptyline hydrochloride. In acidic medium, the calibration curves showed a linear response over the concentration range 10–50 μg mL−1 for initial rate and 10–60 μg mL−1 for fixed time method (2 min). In basic medium, the calibration graphs were linear over the concentration range 10–100 μg mL−1 for initial rate and fixed time methods (4 min). In acidic medium, the limits of detection for initial rate and fixed time methods (2 min) were 1.02 and 3.26 μg mL−1, respectively. In basic medium, the limits of detection were found to be 1.67 and 1.55 μg mL−1 for initial rate and fixed time methods (4 min), respectively. The initial rate and fixed time methods have been successfully applied to the determination of nortriptyline hydrochloride in commercial dosage form. Statistical comparison of the results of the proposed methods with those of reference method exhibited excellent agreement and there is no significant difference between the compared methods in terms of accuracy and precision.KEY WORDS: dosage forms, fixed time method, initial rate method, nortriptyline, potassium permanganate  相似文献   

3.
Oligonucleotide ligation assay (OLA) is considered to be a very useful methodology for the detection and characterization of mutations, particularly for clinical purposes. The fluorescence resonance energy transfer between a fluorescent donor and a suitable fluorophore as acceptor has been applied in the past to several scientific fields. This technique is well adapted to nucleic acid analysis such as DNA sequencing, DNA hybridization and polymerase chain reaction. We describe here a homogeneous format based on the use of a rare earth cryptate label as donor: tris-bipyridine-Eu3+. The long-lived fluorescence of this label makes it possible to reach a high sensitivity by using a time-resolved detection mode. A non-radiative energy transfer technology, known as time-resolved amplification of cryptate emission (TRACE®) characterized by a temporal and spectral selectivity has been developed. The TRACE® detection of characterized single nucleotide polymorphism using the OLA for allelic discrimination is proposed. We demonstrate the potentialities of this OLA–TRACE® methodology through the analysis of K-ras oncogene point mutations.  相似文献   

4.
A novel signal generation principle suitable for real time and end-point detection of specific PCR products in a closed tube is described. Linear DNA probes were labeled at their 5′-ends with a stable, fluorescent terbium chelate. The fluorescence intensity of this chelate is lower when it is coupled to single-stranded DNA than when the chelate is free in solution. The synthesized probes were used in the real time monitoring of PCR using a prototype instrument that consisted of a fluorometer coupled to a thermal cycler. When the probe anneals to a complementary target amplicon, the 5′→3′ exonucleolytic activity of DNA polymerase detaches the label from the probe. This results in an enhanced terbium fluorescence signal. Since terbium has a long excited state lifetime, its fluorescence can be measured in a time-resolved manner, which results in a low background fluorescence and a 1000-fold signal amplification. The detection method is quantitative over an extremely wide linear range (at least 10–107 initial template molecules). The label strategy can easily be combined with existing label technologies, such as TaqMan 5′-exonuclease assays, in order to carry out multiplex assays that do not suffer from overlapping emission peaks of the fluorophores.  相似文献   

5.
Limited prospective data are available on the importance of estimated glomerular filtration rate (GFR) and proteinuria in the prediction of all-cause mortality (ACM) in community-based elderly populations. We examined the relationship between GFR or proteinuria and ACM in 949 randomly selected community-dwelling elderly subjects (aged ≥65 years) over a 5-year period. A spot urine sample was used to measure proteinuria by the dipstick test, and GFR was estimated using the chronic kidney disease-epidemiology collaboration (CKD-EPI) equation. Information about mortality and causes of death was collected by direct enquiry with the subjects and from the national mortality data. Compared to subjects without proteinuria, those with proteinuria of grade ≥1+ had a 1.725-fold (1.134–2.625) higher risk of ACM. Compared to subjects with GFR ≥90 ml/min/1.73 m2, those with GFR<45 ml/min/1.73 m2 had a 2.357 -fold (1.170–4.750) higher risk for ACM. Among the 403 subjects included in the analysis of renal progression, the annual rate of GFR change during follow-up period was −0.52±2.35 ml/min/1.73 m2/year. The renal progression rate was 7.315-fold (1.841–29.071) higher in subjects with GFR<60 ml/min/1.73 m2 than in those with GFR ≥60 ml/min/1.73 m2. Among a community-dwelling elderly Korean population, decreased GFR of <45 ml/min/1.73 m2 and proteinuria were independent risk factors for ACM.  相似文献   

6.
There is an urgent need for rapid and reliable methods able to detect melamine in animal feed. In this study, a quick, simple, and sensitive method for the determination of melamine content in animal feed was developed using surface-enhanced Raman spectroscopy on fabricated Ag nanorod (AgNR) array substrates with a one-step sample extraction procedure. The AgNR array substrates washed by HNO3 solvent (10−7 M) and methanol and showed the good stability within 6 months. The Raman shift at △ν = 682 cm−1 was used as the characteristic melamine peak in the calculations. Sufficient linearity was obtained in the 2–200 μg·g−1 range (R2 = 0.926). The limits of detection and quantification were 0.9 and 2 μg·g−1, respectively. The recovery rates were 89.7–93.3%, with coefficients of variation below 2.02%. The method showed good accuracy compared with the tradition GC-MS analysis. This new protocol only need 2 min to fininsh the detection which could be developed for rapid onsite screening of melamine contamination in quality control and market surveillance applications.  相似文献   

7.
Composite nanoparticles were synthesized by eco-friendly hydrothermal process and characterized by different spectroscopic techniques. All the spectroscopic techniques suggested the synthesis of well crystalline optically active composite nanoparticles with average diameter of ∼30 nm. The synthesized nanoparticles were applied for the development of chemical sensor which was fabricated by coating the nanoparticles on silver electrode for the recognition of phthalimide using simple I–V technique. The developed sensor exhibited high sensitivity (1.7361 µA.mM−1.cm−2), lower detection limit (8.0 µM) and long range of detection (77.0 µM to 0.38 M). Further the resistances of composite nanoparticles based sensor was found to be 2.7 MΩ which change from 2.7 to 1.7 with change in phthalimide concentration. The major advantages of the designed sensor over existing sensors are its simple technique, low cost, lower detection limit, high sensitivity and long range of detection. It can detect phthalimide even at trace level and sense over wide range of concentrations. Therefore the composite nanoparticals would be a better choice for the fabrication of phthalimide chemical sensor and would be time and cost substituted implement for environmental safety.  相似文献   

8.
An automated Flow Injection Analysis system using stop-flow technique for quantifying ethanol based in a colorimetric detection method was developed. The system permitted analysis in a linear range of 0.05–1 g ethanol l–1 without external dilution, a sampling frequency of 15 analyses per hour, and a relative standard deviation of 3.5%. A dilution line was implemented in the FIA system permitting the extension of the linear range to 0.5–5.2 g ethanol l–1 maintaining the same sampling frequency and standard deviation. The system was applied to measure ethanol concentrations present in samples of an alcoholic fermentation and the results showed no significant difference with other analytical procedures (GC).  相似文献   

9.
Foodborne pathogen detection using biomolecules and nanomaterials may lead to platforms for rapid and simple electronic biosensing. Integration of single walled carbon nanotubes (SWCNTs) and immobilized antibodies into a disposable bio-nano combinatorial junction sensor was fabricated for detection of Escherichia coli K-12. Gold tungsten wires (50 µm diameter) coated with polyethylenimine (PEI) and SWCNTs were aligned to form a crossbar junction, which was functionalized with streptavidin and biotinylated antibodies to allow for enhanced specificity towards targeted microbes. In this study, changes in electrical current (ΔI) after bioaffinity reactions between bacterial cells (E. coli K-12) and antibodies on the SWCNT surface were monitored to evaluate the sensor''s performance. The averaged ΔI increased from 33.13 nA to 290.9 nA with the presence of SWCNTs in a 108 CFU/mL concentration of E. coli, thus showing an improvement in sensing magnitude. Electrical current measurements demonstrated a linear relationship (R2 = 0.973) between the changes in current and concentrations of bacterial suspension in range of 102–105 CFU/mL. Current decreased as cell concentrations increased, due to increased bacterial resistance on the bio-nano modified surface. The detection limit of the developed sensor was 102 CFU/mL with a detection time of less than 5 min with nanotubes. Therefore, the fabricated disposable junction biosensor with a functionalized SWCNT platform shows potential for high-performance biosensing and application as a detection device for foodborne pathogens.  相似文献   

10.
Pyrophosphate (PPi) is involved in lots of anabolism and bioenergetic processes in organisms and possesses important biological functions so that its detection is very significant. Here, we developed a selective fluorometric detection method for PPi with a copper(II) complex of 2,6-bis(2-benzimidazolyl)pyridine (bbimp), and then applied it to the detection of bacterial alarmone ppGpp. bbimp has the fluorescence emission at 395 nm, but the bbimp–Cu2+ complex is hardly fluorescent because the intrinsic fluorescence of bbimp is effectively quenched by Cu2+. With the addition of PPi, however, the fluorescence emission of bbimp turns on with a 2 nm red-shift, and has a linear relationship with PPi in the range of 3–90 μmol/L. This method has good selectivity for PPi over other anions especially those phosphate-containing anions such as ATP, UTP, CTP, GTP, GDP, and PO43−.  相似文献   

11.
Furosemide (FD; Lasix®) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-μl sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6–14.0 mg), with a mean urine volume of 3024 ml (range 2620–3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analyses to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography—mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.  相似文献   

12.
Apocynin, a potent inhibitor of NADPH-oxidase, was widely studied for activities in diseases such as inflammation-mediated disorders, asthma and cardiovascular diseases. In our recent study, a novel nitrone derivative of apocynin, AN-1, demonstrated potent inhibition to oxidative injury and to high expression of gp91phox subunit of NADPH-oxidase induced by tert-butyl hydroperoxide (t-BHP) in RAW 264.7 macrophage cells, and displayed promising preclinical protective effect against lipopolysaccharide (LPS)-induced acute lung injury in rats. In this work, the pharmacokinetic behaviors of AN-1 in Sprague-Dawley rats with single intravenous and intragastric doses were investigated for further development. Furthermore, apocynin’s pharmacokinetics remain lacking, even though its pharmacological action has been extensively evaluated. The pharmacokinetics of parent apocynin were also comparatively characterized. A simple HPLC method was developed and validated to determine both AN-1 and apocynin in rat plasma. The chromatographic separation was achieved on an Agilent HC-C18 column (250 mm×4.6 mm, 5 µm) at an isocratic flow rate of 1.0 mL/min, with the mobile phase of methanol and water (53∶47, v/v) and the UV detection set at 279 nm. Good linearity was established over the concentration range of 0.1–500 µg/mL for AN-1 and 0.2–100 µg/mL for apocynin. The absolute recovery, precision and accuracy were satisfactory. Compared with the parent compound apocynin, AN-1 yielded a much longer T1/2 (AN-1 179.8 min, apocynin 6.1 min) and higher AUC0–t (AN-1 61.89 mmol/L·min, apocynin 2.49 mmol/L·min) after equimolar intravenous dosing (0.302 mmol/kg). The absolute bioavailability of oral AN-1 was 78%, but that of apocynin was only 2.8%. The significant improvement of pharmacokinetic behavior might be accounted for the effective pharmacodynamic results we documented for the novel nitrone derivative AN-1.  相似文献   

13.
Permeation of cystic fibrosis transmembrane conductance regulator (CFTR) Cl channels by halide ions was studied in stably transfected Chinese hamster ovary cells by using the patch clamp technique. In cell-attached patches with a high Cl pipette solution, the CFTR channel displayed outwardly rectifying currents and had a conductance near the membrane potential of 6.0 pS at 22°C or 8.7 pS at 37°C. The current–voltage relationship became linear when patches were excised into symmetrical, N-tris(hydroxymethyl)methyl-2-aminomethane sulfonate (TES)-buffered solutions. Under these conditions, conductance increased from 7.0 pS at 22°C to 10.9 pS at 37°C. The conductance at 22°C was ∼1.0 pS higher when TES and HEPES were omitted from the solution, suggesting weak, voltage-independent block by pH buffers. The relationship between conductance and Cl activity was hyperbolic and well fitted by a Michaelis-Menten–type function having a K m of ∼38 mM and maximum conductance of 10 pS at 22°C. Dilution potentials measured with NaCl gradients indicated high anion selectivity (PNa/PCl = 0.003–0.028). Biionic reversal potentials measured immediately after exposure of the cytoplasmic side to various test anions indicated PI (1.8) > PBr (1.3) > PCl (1.0) > PF (0.17), consistent with a “weak field strength” selectivity site. The same sequence was obtained for external halides, although inward F flow was not observed. Iodide currents were protocol dependent and became blocked after 1–2 min. This coincided with a large shift in the (extrapolated) reversal potential to values indicating a greatly reduced I/Cl permeability ratio (PI/PCl < 0.4). The switch to low I permeability was enhanced at potentials that favored Cl entry into the pore and was not observed in the R347D mutant, which is thought to lack an anion binding site involved in multi-ion pore behavior. Interactions between Cl and I ions may influence I permeation and be responsible for the wide range of PI/PCl ratios that have been reported for the CFTR channel. The low PI/PCl ratio usually reported for CFTR only occurred after entry into an altered permeability state and thus may not be comparable with permeability ratios for other anions, which are obtained in the absence of iodide. We propose that CFTR displays a “weak field strength” anion selectivity sequence.  相似文献   

14.
Atrazine is a common agricultural pesticide which has been reported to occur widely in surface drinking water, making it an environmental pollutant of concern. In the quest for developing sensitive detection methods for pesticides, the use of quantum dots (QDs) as sensitive fluorescence probes has gained momentum in recent years. QDs have attractive and unique optical properties whilst coupling of QDs to molecularly imprinted polymers (MIPs) has been shown to offer excellent selectivity. Thus, the development of QD@MIPs based fluorescence sensors could provide an alternative for monitoring herbicides like atrazine in water. In this work, highly fluorescent CdSeTe/ZnS QDs were fabricated using the conventional organometallic synthesis approach and were then encapsulated with MIPs. The CdSeTe/ZnS@MIP sensor was characterized and applied for selective detection of atrazine. The sensor showed a fast response time (5 min) upon interaction with atrazine and the fluorescence intensity was linearly quenched within the 2–20 mol L?1 atrazine range. The detection limit of 0.80 × 10?7 mol L?1 is comparable to reported environmental levels. Lastly, the sensor was applied in real water samples and showed satisfactory recoveries (92–118%) in spiked samples, hence it is a promising candidate for use in water monitoring.  相似文献   

15.
Myocardial ischemia–reperfusion (I/R) causes severe cardiac damage. Although the primary function of oxymyoglobin (Mb) has been considered to be cellular O2 storage and supply, previous research has suggested that Mb is a potentially protective element against I/R injury. However, the mechanism of its protective action is still largely unknown. With a real-time fluorescent technique, we observed that at the onset of ischemia, there was a small burst of superoxide (O2•–) release, as visualized in an isolated rat heart. Thus, we hypothesize that the formation of O2•– correlates to Mb due to a decrease in oxygen tension in the myocardium. Measurement of O2•– production in a Langendorff apparatus was performed using surface fluorometry. An increase in fluorescence was observed during the onset of ischemia in hearts perfused with a solution of hydroethidine, a fluorescent dye sensitive to intracellular O2•–. The increase of fluorescence in the ischemic heart was abolished by a superoxide dismutase mimic, carbon monoxide, or by Mb-knockout gene technology. Furthermore, we identified that O2•– was not generated from the intracellular endothelium but from the myocytes, which are a rich source of Mb. These results suggest that during the onset of ischemia, Mb is responsible for generating O2•–. This novel mechanism may shed light on the protective role of Mb in I/R injury.  相似文献   

16.
A rapid, selective, and sensitive method to determine the melamine content in animal feeds was developed using surface-enhanced Raman scattering spectroscopy on aggregated 55 nm Au nanoparticles with liquid–liquid extraction sample preparation. Butyl alcohol was used as the initial extraction solvent, and liquid–liquid extraction was performed twice using HCl (pH 3–4) and 6∶1 (v/v) n-butyl alcohol/ethyl acetate. The intensity of the matrix-based peak at 731 cm−1 was set at 100 as a basis for the feeds, and the peak at 707 cm−1 was the characteristic peak of melamine used in the calculations. Sufficient linearity was obtained in the range 2–10 µg·g−1 (R 2 = 0.991). Limits of detection and quantification in the feeds were 0.5 and 2 µg·g−1, respectively. The recovery rates were 82.5–90.2% with coefficients of variation below 4.02%. This new protocol could be easily developed for the routine monitoring of on-site feed quality and market surveillance.  相似文献   

17.
We report here the utility of major histocompatibility complex (MHC) class II dextramers for in situ detection of self-reactive CD4 T cells in two target organs, the brain and heart. We optimized the conditions for in situ detection of antigen-specific CD4 T cells using brain sections obtained from SJL mice immunized with myelin proteolipid protein (PLP) 139–151; the sections were costained with IAs/PLP 139–151 (specific) or Theiler''s murine encephalomyelitis virus (TMEV) 70–86 (control) dextramers and anti-CD4. Analysis of sections by laser scanning confocal microscope revealed detection of cells positive for PLP 139–151 but not for TMEV 70–86 dextramers to be colocalized with CD4-expressing T cells, indicating that the staining was specific to PLP 139–151 dextramers. Further, we devised a method to reliably enumerate the frequencies of antigen-specific T cells by counting the number of dextramer+ CD4+ T cells in the ‘Z’ serial images acquired sequentially. We next extended these observations to detect cardiac myosin-specific T cells in autoimmune myocarditis induced in A/J mice by immunizing with cardiac myosin heavy chain-α (Myhc) 334–352. Heart sections prepared from immunized mice were costained with Myhc 334–352 (specific) or bovine ribonuclease 43–56 (control) dextramers together with anti-CD4; the sections showed the infiltrations of Myhc-specific CD4 T cells. The data suggest that MHC class II dextramers are useful tools for enumerating the frequencies of antigen-specific CD4 T cells in situ by direct staining without having to amplify the fluorescent signals, an approach commonly employed with conventional MHC tetramers.  相似文献   

18.
In their natural habitats bacteria are frequently exposed to sudden changes in temperature that have been shown to affect their swimming. With our believed to be new methods of rapid temperature control for single-molecule microscopy, we measured here the thermal response of the Na+-driven chimeric motor expressed in Escherichia coli cells. Motor torque at low load (0.35 μm bead) increased linearly with temperature, twofold between 15°C and 40°C, and torque at high load (1.0 μm bead) was independent of temperature, as reported for the H+-driven motor. Single cell membrane voltages were measured by fluorescence imaging and these were almost constant (∼120 mV) over the same temperature range. When the motor was heated above 40°C for 1–2 min the torque at high load dropped reversibly, recovering upon cooling below 40°C. This response was repeatable over as many as 10 heating cycles. Both increases and decreases in torque showed stepwise torque changes with unitary size ∼150 pN nm, close to the torque of a single stator at room temperature (∼180 pN nm), indicating that dynamic stator dissociation occurs at high temperature, with rebinding upon cooling. Our results suggest that the temperature-dependent assembly of stators is a general feature of flagellar motors.  相似文献   

19.
A fast and direct method for the monitoring of enzymatic DNA hydrolysis was developed using electrospray ionization mass spectrometry. We incorporated the use of a robotic chip-based electrospray ionization source for increased reproducibility and throughput. The mass spectrometry method allows the detection of DNA fragments and intact non-covalent protein–DNA complexes in a single experiment. We used the method to monitor in real-time single-stranded (ss) DNA hydrolysis by colicin E9 DNase and to characterize transient non-covalent E9 DNase–DNA complexes present during the hydrolysis reaction. The mass spectra showed that E9 DNase interacts with ssDNA in the absence of a divalent metal ion, but is strictly dependent on Ni2+ or Co2+ for ssDNA hydrolysis. We demonstrated that the sequence selectivity of E9 DNase is dependent on the ratio protein:ssDNA or the ssDNA concentration and that only 3′-hydroxy and 5′-phosphate termini are produced. It was also shown that the homologous E7 DNase is reactive with Zn2+ as transition metal ion and that this DNase displays a different sequence selectivity. The method described is of general use to analyze the reactivity and specificity of nucleases.  相似文献   

20.
We present the first detailed study using multispectral multiphoton fluorescence lifetime imaging to differentiate basal cell carcinoma cells (BCCs) from normal keratinocytes. Images were acquired from 19 freshly excised BCCs and 27 samples of normal skin (in & ex vivo). Features from fluorescence lifetime images were used to discriminate BCCs with a sensitivity/specificity of 79%/93% respectively. A mosaic of BCC fluorescence lifetime images covering >1 mm2 is also presented, demonstrating the potential for tumour margin delineation. Using 10,462 manually segmented cells from the image data, we quantify the cellular morphology and spectroscopic differences between BCCs and normal skin for the first time. Statistically significant increases were found in the fluorescence lifetimes of cells from BCCs in all spectral channels, ranging from 19.9% (425–515 nm spectral emission) to 39.8% (620–655 nm emission). A discriminant analysis based diagnostic algorithm allowed the fraction of cells classified as malignant to be calculated for each patient. This yielded a receiver operator characteristic area under the curve for the detection of BCC of 0.83. We have used both morphological and spectroscopic parameters to discriminate BCC from normal skin, and provide a comprehensive base for how this technique could be used for BCC assessment in clinical practice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号