首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Prediction of femoral head collapse in osteonecrosis   总被引:6,自引:0,他引:6  
The femoral head deteriorates in osteonecrosis. As a consequence of that, the cortical shell of the femoral head can buckle into the cancellous bone supporting it. In order to examine the buckling scenario we performed numerical analysis of a realistic femoral head model. The analysis included a solution of the hip contact problem, which provided the contact pressure distribution, and subsequent buckling simulation based on the given contact pressure. The contact problem was solved iteratively by approximating the cartilage by a discrete set of unilateral linear springs. The buckling calculations were based on a finite element mesh with brick elements for the cancellous bone and shell elements for the cortical shell. Results of 144 simulations for a variety of geometrical, material, and loading parameters strengthen the buckling scenario. They, particularly, show that the normal cancellous bone serves as a strong supporting foundation for the cortical shell and prevents it from buckling. However, under the development of osteonecrosis the deteriorating cancellous bone is unable to prevent the cortical shell from buckling and the critical pressure decreases with the decreasing Young modulus of the cancellous bone. The local buckling of the cortical shell seems to be the driving force of the progressive fracturing of the femoral head leading to its entire collapse. The buckling analysis provides an additional criterion of the femoral head collapse, the critical contact pressure. The buckling scenario also suggests a new argument in speculating on the femoral head reinforcement. If the entire collapse of the femoral head starts with the buckling of the cortical shell then it is reasonable to place the reinforcement as close to the cortical shell as possible.  相似文献   

2.
The mechanical properties of cancellous bone, as measured from bone plug samples have been widely documented. However, few tests have been attempted to explore the effects the intertrabecular contents may have on the load bearing capabilities. In this study, canine femoral heads were subjected to dynamic compressive strain cycles. The femoral heads were tested intact, as well as with disrupted boundary conditions of the continuous, intraosseous fluid space. A significant reduction in mechanical stiffness was observed when the fluid compartment boundary was disrupted by drilling a hole part way into the femoral neck. A finite element model of a typical femoral head showed that the stiffness change was not due to removal of material from the neck, hydraulic effects notwithstanding. Refilling the hole in the neck with saline solution and sealing the boundary restored the stiffness to the intact baseline level. However, an increase in the fluid pressure did not cause a statistically significant increase in the stiffness of the femoral head.  相似文献   

3.
Patient specific quantitative CT (QCT) imaging data together with the finite element (FE) method may provide an accurate prediction of a patient's femoral strength and fracture risk. Although numerous FE models investigating femoral fracture strength have been published, there is little consent on the effect of boundary conditions, dynamic loading and hydraulic strengthening due to intra-medullary pressure on the predicted fracture strength. We developed a QCT-derived FE model of a proximal femur that included node-specific modulus assigned based on the local bone density. The effect of three commonly used boundary conditions published in literature were investigated by comparing the resulting strain field due to an applied fracture load. The models were also augmented with viscoelastic material properties and subject to a realistic impact load profile to determine the effect of dynamic loads on the strain field. Finally, the effect of hydraulic strengthening was investigated by including node specific permeability and performing a coupled pore diffusion and stress analysis of the FE model. Results showed that all boundary conditions yield the same strain field patterns, but peak strains were 22% lower and fracture load was 18% higher when loaded at the greater trochanter than when loaded at the femoral head. Comparison of the dynamic models showed that material viscoelasticity was important, but inertial effects (vibration and shock) were not. Finally, pore pressure changes did not cause significant hydraulic strengthening of bone under fall impact loading.  相似文献   

4.
This communication reports the results of a three-dimensional finite element (FE) model of stresses in a surgically altered femur and tibia. The model incorporated a novel approach in implementing orthotropic and inhomogeneous bone properties and non-uniform distributed loading. Cortical, cancellous, and subchondral bone of the femur and the tibia were modeled. Mechanical properties for the cortical and cancellous bone were mapped from published data characterizing the anisotropy and inhomogeneity of the bone properties. Mesh adequacy was determined using stress convergence and strain energy error convergence. Qualitatively, the results of the study compare well with experimental principal compressive strains from the literature. With respect to tunnel placement in anterior cruciate ligament reconstruction, the model predicted stress-shielding at the postero-lateral region of the tunnel wall, and increased stress at the postero-medial region of the tunnel wall. The stresses in the cancellous bone beneath the tunnel were, in general, lower than those above the tunnel. Prolonged stress shielding leads to bone resorption of the posterior tunnel wall leading to tunnel enlargement, and possible compromise of the ACL reconstruction. The stresses on the femoral cortex produced from a button-type fixation were noticeable for low levels of loading; the stress levels were very similar in models incorporating bone properties of patients aged 45 and 65. Repeated compression of the femoral cortex at these stress levels may cause microdamage to the cortex eventually resulting in fatigue failure.  相似文献   

5.
An appropriate method of application of the hip-joint force and stress analysis of the pelvic bone, in particular the acetabulum, is necessary to investigate the changes in load transfer due to implantation and to calculate the reference stimulus for bone remodelling simulations. The purpose of the study is to develop a realistic 3D finite element (FE) model of the hemi-pelvis and to assess stress and strain distribution during a gait cycle. The FE modelling approach of the pelvic bone was based on CT scan data and image segmentation of cortical and cancellous bone boundaries. Application of hip-joint force through an anatomical femoral head having a cartilage layer was found to be more appropriate than a perfectly spherical head, thereby leading to more accurate stress–strain distribution in the acetabulum. Within the acetabulum, equivalent strains varied between 0.1% and 0.7% strain in the cancellous bone. High compressive (15–30 MPa) and low tensile (0–5 MPa) stresses were generated within the acetabulum. The hip-joint force is predominantly transferred from the acetabulum through the lateral cortex to the sacroiliac joint and the pubic symphysis. The study is useful to understand the load transfer within the acetabulum and for further investigations on acetabular prosthesis.  相似文献   

6.
Concept and development of an orthotropic FE model of the proximal femur   总被引:2,自引:0,他引:2  
PURPOSE: In contrast to many isotropic finite-element (FE) models of the femur in literature, it was the object of our study to develop an orthotropic FE "model femur" to realistically simulate three-dimensional bone remodelling. METHODS: The three-dimensional geometry of the proximal femur was reconstructed by CT scans of a pair of cadaveric femurs at equal distances of 2mm. These three-dimensional CT models were implemented into an FE simulation tool. Well-known "density-determined" bony material properties (Young's modulus; Poisson's ratio; ultimate strength in pressure, tension and torsion; shear modulus) were assigned to each FE of the same "CT-density-characterized" volumetric group.In order to fix the principal directions of stiffness in FE areas with the same "density characterization", the cadaveric femurs were cut in 2mm slices in frontal (left femur) and sagittal plane (right femur). Each femoral slice was scanned into a computer-based image processing system. On these images, the principal directions of stiffness of cancellous and cortical bone were determined manually using the orientation of the trabecular structures and the Haversian system. Finally, these geometric data were matched with the "CT-density characterized" three-dimensional femur model. In addition, the time and density-dependent adaptive behaviour of bone remodelling was taken into account by implementation of Carter's criterion. RESULTS: In the constructed "model femur", each FE is characterized by the principal directions of the stiffness and the "CT-density-determined" material properties of cortical and cancellous bone. Thus, on the basis of anatomic data a three-dimensional FE simulation reference model of the proximal femur was realized considering orthotropic conditions of bone behaviour. CONCLUSIONS: With the orthotropic "model femur", the fundamental basis has been formed to realize realistic simulations of the dynamical processes of bone remodelling under different loading conditions or operative procedures (osteotomies, total hip replacements, etc).  相似文献   

7.
Assessment of the mechanical properties of trabecular bone is of major biological and clinical importance for the investigation of bone diseases, fractures and their treatments. Finite element (FE) methods are getting increasingly popular for quantifying the elastic and failure properties of trabecular bone. In particular, voxel-based FE methods have been previously used to calculate the effective elastic properties of trabecular microstructures. However, in most studies, bone tissue moduli were assumed or back-calculated to match the apparent elastic moduli from experiments, which often lead to surprisingly low values when compared to nanoindentation results. In this study, voxel-based FE analysis of trabecular bone is combined with physical measures of volume fraction, micro-CT (microCT) reconstructions, uniaxial mechanical tests and specimen-specific nanoindentation tests for proper validation of the method. Cylindrical specimens of cancellous bone were extracted from human femurs and their volume fraction determined with Archimede's method. Uniaxial apparent modulus of the specimens was measured with an improved tension-compression testing protocol that minimizes boundary artefacts. Their microCT reconstructions were segmented to match the measured bone volume fraction and used to create full-size voxel models with 30-45 microm element size. For each specimen, linear isotropic elastic material properties were defined based on specific nanoindentation measurements of its embedded bone tissue. Linear FE analyses were finally performed to simulate the uniaxial mechanical tests. Additional parametric analyses were performed to evaluate the potential errors on the predicted apparent modulus arising from variations in segmentation threshold, tissue modulus, and the use of 125-mm(3) cubic sub-regions. The results demonstrate an excellent correspondence between experimental measures and FE predictions of uniaxial apparent modulus. In conclusion, the adopted voxel-based FE approach is found to be a robust method to predict the linear elastic properties of human cancellous bone, provided segmentation of the microCT reconstructions is carefully calibrated, tissue modulus is known a priori and the entire region of interest is included in the analysis.  相似文献   

8.
The finite element (FE) model of the pelvic joint is helpful for clinical diagnosis and treatment of pelvic injuries. However, the effect of an FE model boundary condition on the biomechanical behavior of a pelvic joint has not been well studied. The objective of this study was to study the effect of boundary condition on the pelvic biomechanics predictions. A 3D FE model of a pelvis using subject-specific estimates of intact bone structures, main ligaments and bone material anisotropy by computed tomography (CT) gray value was developed and validated by bone surface strains obtained from rosette strain gauges in an in vitro pelvic experiment. Then three FE pelvic models were constructed to analyze the effect of boundary condition, corresponding to an intact pelvic joint, a pelvic joint without sacroiliac ligaments and a pelvic joint without proximal femurs, respectively. Vertical load was applied to the same pelvis with a fixed prosthetic femoral stem and the same load was simulated in the FE model. A strong correlation coefficient (R(2)=0.9657) was calculated, which indicated a strong correlation between the FE analysis and experimental results. The effect of boundary condition changes on the biomechanical response depended on the anatomical location and structure of the pelvic joint. It was found that acetabulum fixed in all directions with the femur removed can increase the stress distribution on the acetabular inner plate (approximately double the original values) and decrease that on the superior of pubis (from 7 MPa to 0.6 MPa). Taking sacrum and ilium as a whole, instead of sacroiliac and iliolumber ligaments, can influence the stress distribution on ilium and pubis bone vastly. These findings suggest pelvic biomechanics is very dependent on the boundary condition in the FE model.  相似文献   

9.
Strong correspondence between the uniaxial apparent strength and stiffness of cancellous bone allows the use of stiffness as a predictor of bone strength. Measured values of mechanical properties in cancellous bone can be different between experiments due to different experimental conditions. In the current study, bone volume fraction, experimentally determined and finite element (FE) predicted stiffness were examined as predictors of cancellous bone ultimate strength in two different groups each of which was tested using a different end constraint. It is demonstrated that, although always significant, the relationships of strength with bone volume fraction and experimentally determined stiffness are different between test groups. Apparent stiffness, estimated by FE modeling, predicts the ultimate strength of human cancellous bone consistently for all examined experimental protocols.  相似文献   

10.
Finite element stress analyses were conducted of the canine femoral head before and after implantation of various surface replacement-type components. The femoral head was replaced by four implant geometries; (a) shell, (b) shell with peg, (c) shell with rod, and (d) a new epiphyseal replacement design. All implants were modelled to simulate bony ingrowth along the underside of the shell and along the surfaces of the peg and rod. The results indicated that in the normal femur the forces are transferred from the articular surface through the femoral head cancellous bone to the inferior cortical shell of the femoral neck. After shell-type surface replacement, forces were transferred more distally at the rim of the shell and at the end of the peg or rod, thereby reducing the stresses in the proximal head cancellous bone. Computer simulation of bone remodelling due to proximal bone stress reduction was shown to accentuate the abnormality of the stress fields. Surface replacement with a lower modulus material created a less abnormal redistribution of bone stresses. The new epiphyseal replacement design resulted in stress distributions similar to those in the normal femoral head and minimal shear stresses at the implant/bone interface. These findings suggest that the epiphyseal replacement concept may provide better initial mechanical integrity and create a more benign milieu for adaptive bone remodelling than conventional, shell-type surface replacement components.  相似文献   

11.
This paper presents a finite element (FE) model to identify parameters that affect the performance of an improved cancellous bone screw fixation technique, and hence potentially improve fracture treatment. In cancellous bone of low apparent density, it can be difficult to achieve adequate screw fixation and hence provide stable fracture fixation that enables bone healing. Data from predictive FE models indicate that cements can have a significant potential to improve screw holding power in cancellous bone. These FE models are used to demonstrate the key parameters that determine pull-out strength in a variety of screw, bone and cement set-ups, and to compare the effectiveness of different configurations. The paper concludes that significant advantages, up to an order of magnitude, in screw pull-out strength in cancellous bone might be gained by the appropriate use of a currently approved calcium phosphate cement.  相似文献   

12.
13.
Malalignment is the main cause of tibial component loosening. Implants that migrate rapidly in the first two post-operative years are likely to present aseptic loosening. It has been suggested that cancellous bone stresses can be correlated with tibial component migration. A recent study has shown that patient-specific finite element (FE) models have the power to predict the short-term behavior of tibial trays. The stresses generated within the implanted tibia are dependent on the kinematics of the joint; however, previous studies have ignored the kinematics and only applied static loads. Using explicit FE, it is possible to simultaneously predict the kinematics and stresses during a gait cycle. The aim of this study was to examine the cancellous bone strains during the stance phase of the gait cycle, for varying degrees of varus/valgus eccentric loading using explicit FE. A patient-specific model of a proximal tibia was created from CT scan images, including heterogeneous bone properties. The proximal tibia was implanted with a commercial total knee replacement (TKR) model. The stance phase of gait was simulated and the applied loads and boundary conditions were based on those used for the Stanmore knee simulator. Eccentric loading was simulated. As well as examining the tibial bone strains (minimum and maximum principal strain), the kinematics of the bone-implant construct are also reported. The maximum anterior-posterior displacements and internal-external rotations were produced by the model with 20 mm offset. The peak minimum and maximum principal strain values increased as the load was shifted laterally, reaching a maximum magnitude for -20 mm offset. This suggests that when in varus, the load transferred to the bone is shifted medially, and as the bone supporting this load is stiffer, the resulting peak bone strains are lower than when the load is shifted laterally (valgus). For this particular patient, the TKR design analyzed produced the highest cancellous bone strains when in valgus. This study has provided an insight in the variations produced in bone strain distribution when the axial load is applied eccentrically. To the authors' knowledge, this is the first time that the bone strain distribution of a proximal implanted tibia has been examined, also accounting for the kinematics of the tibio-femoral joint as part of the simulation. This approach gives greater insight into the overall performance of TKR.  相似文献   

14.
Biphasic properties of articular cartilage allow it to be an excellent bearing material and have been studied through several simplified experiments as well as finite element modelling. However, three-dimensional biphasic finite element (FE) models of the whole joint are rare. The current study was carried out to experimentally validate FE methodology for modelling hemiarthroplasty. Material properties such as equilibrium elastic modulus and permeability of porcine acetabular cartilage were initially derived by curve-fitting an experimental deformation curve with that obtained using FE. These properties were then used in the hemiarthroplasty hip joint modelling. Each porcine acetabular cup was loaded with 400N using a 34mm diameter CoCr femoral head. A specimen-specific FE model of each acetabular cup was created using μCT and a series of software processes. Each model was analysed under conditions similar to those tested experimentally. Contact stresses and contact areas predicted by the model, immediately after loading, were then compared with the corresponding experimentally measured values. Very high peak contact stresses (maximum experimental: 14.09MPa) were recorded. A maximum difference of 12.42% was found in peak contact stresses. The corresponding error for contact area was 20.69%. Due to a fairly good agreement in predicted and measured values of contact stresses and contact areas, the integrated methodology developed in this study can be used as a basis for future work. In addition, FE predicted total fluid load support was around 80% immediately after loading. This was lower than that observed in conforming contact problems involving biphasic cartilage and was due to a smaller local contact area and variable clearance making fluid exudation easier.  相似文献   

15.
Models of regular cellular-solids representing femoral head 'medial group' bone were used to (1) compare thickness data for plate-like and beam-like structures at realistic surface areas and densities; (2) test the validity of a standard formula for trabecular thickness (Tb.Th); and (3) study how systematic changes in cancellous bone thicknesses, spacing, and face-connectivity affect relative density and surface area. Models of different face-connectivities, produced by plate removal from the unit cell, were fitted to bone density and surface area data. The medial group bone was anisotropic: the supero-inferior (SI) direction was the principal direction for bone plate alignment and the plane normal to this had the largest number of bone/void intersections per unit line length (P(I)). A comparison of boundary perimeter per unit area data, in planes normal to SI, with surface area data placed the medial group bone between prismatic structures in which walls are parallel to one principal direction and isotropic structures. Selective removal of plates from a closed-cell model produced a similar result. For the same relative density and surface-area, plate-like models had significantly thinner cross-sections than beam-like models. The formula for Tb.Th produced overestimates of model plate thickness by up to 20% at realistic femoral cancellous densities. Trends in data on surface area to volume ratio and density observed on sampled medial group bone could be simulated by plate thickness changes on models of intermediate face-connectivity (approximately 1.5) or by plate removal from models with relatively thick and short (low aspect-ratio) plates. The latter mechanism is unrealistic for it resulted in beam-like structures at low 'medial group' densities, an architecture unlike the predominantly plate-like bone in the sample.  相似文献   

16.
The aim of this study is to observe the changes in osteoprotegerin (OPG) and receptor activator for the nuclear factor-κB ligand (RANKL) in a rabbit model, and to explore the therapeutic effect of tissue engineering bone on femoral head necrosis. A total of 60 rabbits were randomly divided into 5 groups. The necrosis model of femoral head defects was created by dexamethasone combined with a horse serum injection. The model of femoral head necrosis was reconstructed by tissue engineering bone. The protein expressions of OPG and RANKL were detected by Western blot analysis. The expression of OPG and the RANKL protein in group E was higher than that in the other 4 groups (P < .05); there was no significant difference between groups C and D ( P > .05). The expression of OPG protein in the rabbit femoral head necrosis group was improved by xenogeneic antigens of cancellous bone/lentiviral-basic fibroblast growth factor/mesenchymal stem cells, which were expected to be used as an effective tissue engineering material to repair the necrosis of the femoral head.  相似文献   

17.
One difficulty that arises in an analysis of the cross-sectional properties of bone is whether to include cancellous bone in the analysis. The purpose of this paper is to determine how different amounts of cancellous bone affect the measurement of structural properties of bone cross-sections. Thirty-two tibial and femoral cross-sections were chosen at random from a series of cross-sectioned nonhuman primate bones. Geometrical properties were calculated for the cross-sections, and torsional and bending stress analyses were performed. The results suggest that the effect of including cancellous bone in the analysis is closely related to the amount of bone, where it lies within the cross-section, and the type of analysis performed. Including cancellous bone in calculations of structural properties of bone cross-sections may cause the strength and stiffness of the bone to be exaggerated.  相似文献   

18.
The effects of femoral prosthetic heads of diameters 22 and 28 mm were investigated on the stability of reconstructed hemi-pelves with cement mantles of thicknesses 1–4 mm and different bone qualities. Materialise medical imaging package and I-Deas finite element (FE) software were used to create accurate geometry of a hemi-pelvis from CT-scan images. Our FE results show an increase in cement mantle stresses associated with the larger femoral head. When a 22 mm femoral head is used on acetabulae of diameters 56 mm and above, the probability of survivorship can be increased by creating a cement mantle of at least 1 mm thick. However, when a 28 mm femoral head is used, a cement mantle thickness of at least 4 mm is needed. Poor bone quality resulted in an average 45% increase in the tensile stresses of the cement mantles, indicating resulting poor survivorship rate.  相似文献   

19.
There are substantial changes in maternal skeletal dynamics during pregnancy, lactation, and after lactation. The purpose of this study was to correlate changes in cortical and cancellous bone mass, structure, and dynamics with mechanical properties during and after the first reproductive cycle in rats. Rats were mated and groups were taken at parturition, end of lactation and 8 wk after weaning, and were compared with age-matched, nulliparous controls. Measurements were taken on femoral cortical bone and lumbar vertebral body cancellous bone. At the end of pregnancy, there was an increase in cortical periosteal bone formation and an increase in cortical volume, but a suppression of turnover in cancellous bone with no change in cancellous or cortical mechanical properties. Lactation was associated with a decrease in cortical and cancellous bone strength with a decrease in bone volume, but an increase in turnover on cancellous and endocortical surfaces. After lactation, there was a partial or full restoration of mechanical properties. This study demonstrates substantial changes in bone mechanics that correlate with changes in bone structure and dynamics during the first reproductive cycle in rats. The greatest changes were observed during the lactation period with partial or full recovery in the postlactational period.  相似文献   

20.
The purpose of the present study was to compare the effects of alendronate and alfacalcidol on cancellous and cortical bone mass and bone mechanical properties in ovariectomized rats. Twenty-six female Sprague-Dawley rats, 7 months of age, were randomized by the stratified weight method into four groups: the sham-operated control (Sham) group and the three ovariectomy (OVX) groups, namely, OVX + vehicle, OVX + alendronate (2.5 mg/kg, p.o., daily), and OVX + alfacalcidol (0.5 mug/kg, p.o., daily). At the end of the 8-week experimental period, bone histomorphometric analyses of cancellous bone at the proximal tibial metaphysis and cortical bone at the tibial diaphysis were performed, and the mechanical properties of the femoral distal metaphysis and femoral diaphysis were evaluated. OVX decreased cancellous bone volume per total tissue volume (BV/TV), and the maximum load of the femoral distal metaphysis, as a result of increases in serum osteocalcin (OC) levels, and also the number of osteoclasts (N.Oc), osteoclast surface (OcS) and bone formation rate (BFR) per bone surface (BS), and BFR/BV, without any effect on cortical area (Ct Ar), or maximum load of the femoral diaphysis. Alendronate prevented this decrease in cancellous BV/TV by suppressing increases in N.Oc/BS, OcS/BS, BFR/BS, and BFR/BV, without any apparent effect on Ct Ar, or maximum load of the femoral distal metaphysis and femoral diaphysis. On the other hand, alfacalcidol increased cancellous BV/TV, Ct Ar, and the maximum load of the femoral distal metaphysis and femoral diaphysis, by mildly decreasing trabecular BFR/BV, maintaining trabecular mineral apposition rate and osteoblast surface per BS, increasing periosteal and endocortical BFR/BS, and preventing an increase in endocortical eroded surface per BS. The present study clearly showed the differential skeletal effects of alendronate and alfacalcidol in ovariectomized rats. Alendronate prevented OVX-induced cancellous bone loss by suppressing bone turnover, while alfacalcidol improved cancellous and cortical bone mass and bone strength by suppressing bone resorption and maintaining or even increasing bone formation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号