1.

Aims

To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA)

Methods

MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and retrospectively analyzed in this study.

Results

17 patients fulfilled the inclusion criterion. In all 17 patients IOP measurements were performed with RT (34 eyes) and ORA (33 eyes), while PAT measurement was possible in only 12 (24 eyes) patients. The RT, corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated intraocular pressure (IOPg) differed relevantly from IOP assessed with PAT. Corneal clouding in MPS patients correlated positively with PAT, RT and IOPg (r = 0.3, 0.5, and 0.5 respectively), but not with IOPcc (r = 0.07). The MPS-related corneal clouding correlated positively with biomechanical corneal parameters assessed with ORA: corneal hysteresis (r = 0.77) and corneal resistance factor (r = 0.77) either.

Conclusions

RT and ORA measurements were tolerated better than applanation tonometry in MPS patients. IOP measurements assessed with RT and ORA differed relevantly from PAT. Corneal-compensated IOP assessed with ORA seems to be less affected by the MPS-related corneal clouding than applanation or rebound tonometry. RT and ORA measurements should be preferred for IOP assessment in patients with MPS.  相似文献   

2.

Purpose

To study the prevalence of sustained intraocular pressure (IOP) elevation associated with intravitreal injection of anti-vascular endothelial growth factor (anti-VEGF) agents.

Methods

Prospective comparative study. Non-glaucomatous patients scheduled to receive intravitreal injection of anti-VEGF therapy were recruited from an outpatient eye clinic, Songklanagarind Hospital between April 2013 and March 2014. The IOP was measured by Goldmann applanation tonometer before and at 1 hour, 1 week, 1 month, 3 months, and 6 months after injection. The IOP was compared using the repeated measures analysis. Sustained IOP elevation was defined as either an IOP > 21 mmHg or an increase from baseline ≥ 5 mmHg on two consecutive visits.

Results

Seventy eyes of 54 patients met the inclusion criteria. The most common diagnosis was diabetic macular edema (48%). The mean IOP ± standard deviation (SD) before treatment was 13.7 ± 2.8 mmHg. The means ± SDs after treatment at 1 hour, 1 week, 1 month, 3 months, and 6 months were 11.3 ± 2.6, 13.7 ± 3.6, 14.1 ± 3.3, 14.0 ± 2.3, and 13.7 ± 2.4 mmHg, respectively. A mean of IOP difference at 1 hour postinjection and at baseline was −2.36 ± 2.5 mmHg (P < 0.001). Four of 70 treated eyes (5.7%) developed sustained IOP elevation (IOP ≥ 5 mmHg from baseline on two consecutive visits). The IOP returned to baseline levels after 1 month, in three eyes. One eye had sustained IOP elevation at 3 and 6 months follow-up. Thereafter, IOP returned to baseline level. There was no need of anti-glaucoma medication.

Conclusions

After receiving intravitreal injection of anti-VEGF agent, a small proportion of non-glaucomatous eyes developed a sustained IOP elevation without requiring IOP-lowering treatment. At 1 hour postinjection, there was a significant reduction of the mean IOP compared with the baseline level.  相似文献   

3.

Purpose

To investigate whether corneal thickness parameters measured by optical coherence tomography (OCT), such as central corneal thickness (CCT), central corneal stromal thickness (CCST), and central corneal epithelial thickness (CCET), influence the intraocular pressure (IOP) difference measured by Goldmann applanation tonometry (GAT) and non-contact tonometry (NCT).

Methods

In total, 50 eyes from 50 subjects without glaucomatous defects were included in this retrospective, cross-sectional study. We measured IOP using GAT and NCT and calculated the difference between the two methods. CCT was measured by a Cirrus HD-OCT device using anterior segment imaging. The basement membrane of the epithelium, which was seen as a high-reflection line in the OCT image, was taken as a reference line to measure CCST and CCET.

Results

The mean IOP measured by GAT and NCT was 16.7 ± 3.0 and 18.1 ± 3.8 mmHg, respectively. The mean IOP difference was 1.5 ± 1.7 mmHg, and the IOP measured by NCT was 8.4% ± 11.3% higher than that measured by GAT. The CCET and CCST were 57.9 ± 5.6 and 501.7 ± 33.8 μm, respectively. CCT showed a positive correlation with both GAT IOP (r = 0.648, P < 0.001) and NCT IOP (r = 0.676, P < 0.001). Although CCST showed a significant correlation with GAT IOP and NCT IOP, CCET did not. The difference between GAT IOP and NCT IOP increased with CCT (r = 0.333, P = 0.018), and CCET was positively correlated with the IOP difference between GAT and NCT (r = 0.435, P = 0.002).

Conclusions

IOP increased with greater CCT, and CCST seemed to have a more important role than CCET. CCET also increased with greater CCT, and this may be a possible explanation for the increasing difference in IOP between GAT and NCT with increasing CCT.  相似文献   

4.

Purpose

To explore ocular changes in healthy people after exercise.

Methods

Twenty five volunteers underwent exercise for 15 minutes on a treadmill. Measurements of choroidal thickness, intraocular pressure (IOP), ocular biometry, and blood pressure were taken before and after exercise. Enhanced Depth Imaging optical coherence tomography (EDI-OCT) was used to measure choroidal thickness at the fovea. Intraocular pressure (IOP) was measured by Goldmann applanation tonometry. Ocular biometric measures were collected using A scan ultrasound. Blood pressure was measured concurrently with the acquisition of the scans.

Results

Twenty five volunteers (25 eyes) with a mean age of 25.44±3.25 years were measured. There was a significant increase in systolic and diastolic pressure after exercise (P<0.05). The IOP showed a significant decrease after exercise (P<0.05). However there was no significant difference in the mean choroidal thickness, ocular axial length, anterior chamber depth, lens thickness, or vitreous length before and after exercise measurements (P>0.05).

Conclusion

There was a significant decrease in IOP from exercise without a change in choroidal thickness and ocular biometric measures. IOP and choroidal thickness were not correlated, suggesting that the IOP decrease from exercise is not due to changes in choridal thickness.  相似文献   

5.

Purpose

To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups.

Methods

Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes.

Results

The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05).

Conclusions

CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.  相似文献   

6.

Purpose

To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft contact lenses (CLs).

Methods

One eye each in 21 subjects was studied. The cornea was photographed using a high-speed camera at 5,000 frames/sec during non-contact tonometry without contact lenses (NCL), with -5.0 diopters (D), -0.5 D and +5.0 D CL. The displacement of the ocular surface and the factors affecting displacement at the IOP reading and maximum displacement time were investigated.

Results

The IOP readings while wearing +5 D CL were significantly higher than those obtained while wearing -5 D CL. The ocular surface displacement between +5 D CL and other groups were significantly different. A significant positive correlation was found between the ocular surface displacement of subjects at the IOP reading time and the IOP obtained with the non-contact tonometer. A significant negative correlation was found between the ocular surface curvature and the IOP obtained using the non-contact tonometer. The radius of curvature of the ocular surface affected the displacement during the IOP reading and maximum displacement time.

Conclusions

Our results indicate that soft contact lens use changes the ocular surface behavior and IOP readings during non-contact tonometry. The radius of curvature of the eye affects the ocular surface displacement and IOP readings in this situation.  相似文献   

7.

Purpose

To assess the short-term day-to-day reproducibility of 24-hour intraocular pressure (IOP) curves in various respects in untreated primary open-angle glaucoma (POAG) and ocular hypertension (OHT) patients.

Methods

47 subjects with POAG and 34 subjects with OHT underwent IOP measurements every 2 hours in both eyes for consecutive 48 hours by a non-contact tonometer (NCT). IOP values at each time point were recorded. Mean IOP, peak IOP, time difference of peak IOP between two days and IOP fluctuation were also calculated. Intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate reproducibility.

Results

ICCs of the entire IOP values for a complete 24-hour curve were 0.577 and 0.561 in POAG and OHT patients, respectively. ICCs of IOP values at different time points ranged from 0.384 (10am) to 0.686 (4am) in POAG patients and from 0.347 (6am) to 0.760 (4am) in OHT patients. ICCs of mean IOP, peak IOP and IOP fluctuation were respectively 0.832, 0.704, 0.367 in POAG patients and 0.867, 0.816 0.633 in OHT patients. Only 37.23% and 35.29% of the peak IOP time points appeared within the time difference of 2 hours in POAG and OHT patients, respectively, while 53.19% and 48.53% appeared within 4 hours in POAG and OHT patients, respectively.

Conclusion

A 24-hour IOP curve in a single day is not highly reproducible in short-term and has limited use for evaluating individual IOP condition. Mean IOP and peak IOP for a 24-hour IOP curve are useful parameters in clinical follow-up, while IOP value at a certain time point, IOP fluctuation and peak IOP time point should be interpreted with caution.  相似文献   

8.

Main Objective

To compare the course and outcome of first- and fellow-operated eyes in patients who underwent bilateral trabeculectomies and to investigate the factors associated with the difference.

Methods

Preoperative characteristics, including the interval between surgeries, were compared between the first- and fellow-operated eyes in 42 patients who underwent bilateral trabeculectomies. Postoperative intraocular pressure and bleb vascularity, using postoperative anterior segment photos, were compared at various time points between the first- and fellow-operated eyes. Surgical success was evaluated at 1 year after surgery and at the final follow-up. Factors affecting the difference between the first and fellow eyes were analyzed.

Results

There was no significant difference in success or failure rates at 1 year postoperatively and at the final follow-up between the first- and fellow-operated eyes. Early postoperative IOP and the degree of bleb vascularity were higher in the fellow-operated eyes (P = 0.001 and 0.003, respectively at week 1 postoperative). The difference in IOP between the first- and fellow-operated eyes was greater in patients whose interval between surgeries was shorter than 3 weeks (P = 0.026).

Conclusions

In patients undergoing bilateral trabeculectomies, early postoperative IOP was higher in the fellow-operated eyes than the first-operated eyes; the difference was greater when the interval between surgeries was shorter. The first-operated eye may influence the early postoperative inflammatory response in the fellow-operated eye. Our findings have clinical implications for planning treatment of patients who may need bilateral surgery.  相似文献   

9.

Background

Liver dysfunction reflects the status of heart failure, with congestion and low perfusion of the liver serving as causative mechanisms. Previous studies demonstrated relationship between the results of liver function test and the prognosis in patients with heart failure. However, few studies have examined this relationship in patients with pulmonary arterial hypertension (PAH).

Methods

The subjects were 37 patients with PAH (8 men and 29 women; 18 with idiopathic PAH and 19 with connective tissue disease-associated PAH). A blood test was performed after a 3-month period free from hospitalization and without changes in functional class, treatment, heart sounds, body weight, or heart rate.

Results

In a mean follow-up period of 635 ± 510 days, 12 patients died due to heart failure, 2 died due to pulmonary hemorrhage, and 23 patients survived. Cox proportional hazard analyses identified functional class (p < 0.001), plasma concentration of brain natriuretic peptide (BNP) (p = 0.001), and hyperbilirubinemia (serum total bilirubin > 1.2 mg/dL; p < 0.001; hazard ratio = 13.31) as predictors of mortality. Patients with hyperbilirubinemia had a worse functional class (P = 0.003), a higher right atrial pressure (p < 0.001), a higher plasma concentration of BNP (p = 0.004), and a larger Doppler right ventricular index of the right ventricle (p = 0.041).

Conclusion

Elevated serum bilirubin is a risk factor for death in patients with PAH.  相似文献   

10.

Purpose

To investigate the changes of intraocular pressure (IOP) induced by 3-diopter (3 D) accommodation in progressing myopes, stable myopes and emmetropes.

Design

Cross-sectional study.

Participants

318 subjects including 270 myopes and 48 emmetropes.

Methods

195 progressing myopes, 75 stable myopes and 48 emmetropes participated in this study. All subjects had their IOP measured using iCare rebound tonometer while accommodative stimuli of 0 D and 3 D were presented.

Main Outcome Measures

IOP values without accommodation and with 3 D accommodation were measured in all subjects. Baseline IOPs and IOP changes were compared within and between groups.

Results

There was no significant difference in IOPs between progressing myopes, stable myopes and emmetropes when no accommodation was induced (17.47±3.46, 16.62±2.98 and 16.80±3.62 respectively, p>0.05). IOP experienced an insignificantly slight decrease after 3 D accommodation in three groups (mean change -0.19±2.16, -0.03±1.68 and -0.39±2.65 respectively, p>0.05). Subgroup analysis showed in progressing myopic group, IOP of children (<18 years old) declined with accommodation while IOP of adults (≥18 years) increased, and the difference was statistically significant (p = 0.008). However, after excluding the age factor, accommodation induced IOP changes of high progressing myopes (≤-6 D), low, moderate and non-myopes (>-6 D) was not significantly different after Bonferroni correction (p = 0.838).

Conclusions

Although no difference was detected between the baseline IOPs and accommodation induced IOP changes in progressing myopes, stable myopes and emmetropes, this study found accommodation could cause transient IOP elevation in adult progressing myopes.  相似文献   

11.
12.

Purpose

To investigate the effects of lenticule creation and subsequent corneal lenticule extraction on corneal deformation parameters during small incision lenticule extraction (SMILE) procedure.

Materials and Methods

In this prospective study, 18 eyes of 10 patients (27.90±7.11 years, −5.64±2.45 diopters) scheduled for SMILE procedure were enrolled. Changes in the corneal deformation parameters, including deformation amplitude (DA), applanation time(AT1 and AT2), applanation length(AL1 and AL2), corneal velocity(CV1 and CV2), peak distance(P.Dist.), radius and intraocular pressure values were measured preoperatively, immediately after lenticule creation and subsequent to corneal lenticule extraction in all eyes with the Corvis Scheimpflug Technology (Corvis ST, OCULUS, Wetzlar, Germany). Repeated measures analysis of variance (ANOVA) with bonferroni-adjusted post hoc comparisons was performed to investigate changes following each step of the procedure.

Results

All surgical procedures were uneventful. A significant difference was detected among the three time points (pre-operation, post-lenticule creation and post lenticule extraction) for AT1 (P<0.001), AT2 (P = 0.001), DA(P<0.001), and IOP(P = 0.002). Bonferroni-adjusted post hoc comparisons indicated that there was no significant change in AT1, AT2, DA, or IOP after lenticule creation (post hoc P>0.05), but there was a significant change in these parameters following subsequent corneal lenticule extraction (post hoc P<0.01), when compared to values obtained pre-operatively. The scheimpflug camera of the Corvis ST demonstrated the intralamellar small gas bubbles formed from the vaporisation of tissue after lenticule creation and a gray zone was observed between the cap and the residual stromal bed after lenticule extraction.

Conclusions

There is a significant change in corneal deformation parameters following SMILE procedure. The changes may be caused predominantly by stromal lenticule extraction, while lenticule creation with femtosecond laser may not have an obvious effect on corneal deformation properties.  相似文献   

13.
To determine the interdependence of intracranial pressure (ICP) and intraocular pressure (IOP) and how it affects optic nerve pressures, eight normal dogs were examined using pressure-sensing probes implanted into the left ventricle, lumbar cistern, optic nerve subarachnoid space in the left eye, and anterior chamber in the left eye. This allowed ICP, lumbar cistern pressure (LCP), optic nerve subarachnoid space pressure (ONSP) and IOP to be simultaneously recorded. After establishing baseline pressure levels, pressure changes that resulted from lowering ICP (via shunting cerebrospinal fluid (CSF) from the ventricle) were recorded. At baseline, all examined pressures were different (ICP<LCP<ONSP), but correlated (P>0.001). As ICP was lowered during CSF shunting, IOP also dropped in a parallel time course so that the trans-lamina cribrosa gradient (TLPG) remained stable (ICP-IOP dependent zone). However, once ICP fell below a critical breakpoint, ICP and IOP became uncoupled and TLPG changed as ICP declined (ICP-IOP independent zone). The optic nerve pressure gradient (ONPG) and trans-optic nerve pressure gradient (TOPG) increased linearly as ICP decreased through both the ICP-IOP dependent and independent zones. We conclude that ICP and IOP are coupled in a specific pressure range, but when ICP drops below a critical point, IOP and ICP become uncoupled and TLPG increases. When ICP drops, a rise in the ONPG and TOPG creates more pressure and reduces CSF flow around the optic nerve. This change may play a role in the development and progression of various ophthalmic and neurological diseases, including glaucoma.  相似文献   

14.

Background

Opening of an occluded infarct related artery reduces infarct size and improves survival in acute ST-elevation myocardial infarction (STEMI). In this study we performed tissue Doppler analysis (peak strain, displacement, mitral annular movement (MAM)) and compared with visual assessment for the study of the correlation of measurements of global, regional and segmental function with final infarct size and transmurality. In addition, myocardial risk area was determined and a prediction sought for the development of infarct transmurality ≥50%.

Methods

Twenty six patients with STEMI submitted for primary percutaneous coronary intervention (PCI) were examined with echocardiography on the catheterization table. Four to eight weeks later repeat echocardiography was performed for reassessment of function and magnetic resonance imaging for the determination of final infarct size and transmurality.

Results

On a global level, wall motion score index (WMSI), ejection fraction (EF), strain, and displacement all showed significant differences (p ≤ 0.001, p ≤ 0.001, p ≤ 0.001 and p = 0.03) between the two study visits, but MAM did not (p = 0.17). On all levels (global, regional and segmental) and both pre- and post PCI, WMSI showed a higher correlation with scar transmurality compared to strain. We found that both strain and WMSI predicted the development of scar transmurality ≥50%, but strain added no significant information to that obtained with WMSI in a logistic regression analysis.

Conclusions

In patients with acute STEMI, WMSI, EF, strain, and displacement showed significant changes between the pre- and post PCI exam. In a ROC-analysis, strain had 64% sensitivity at 80% specificity and WMSI around 90% sensitivity at 80% specificity for the detection of scar with transmurality ≥50% at follow-up.  相似文献   

15.

Background

In comparison to the well established changes in compliance that occur at the large vessel level in diabetes, much less is known about the changes in compliance of the cardiovascular system at the end-organ level. The aim of this study was therefore to examine whether there was a correlation between resistance of the intrarenal arteries of the kidney and compliance of the left ventricle, as estimated by measurements of diastolic function, in subjects with type 2 diabetes.

Methods

We studied 167 unselected clinic patients with type 2 diabetes with a kidney duplex scan to estimate intrarenal vascular resistance, i.e. the resistance index (RI = peak systolic velocity-minimum diastolic velocity/peak systolic velocity) and a transthoracic echocardiogram (TTE) employing tissue doppler studies to document diastolic and systolic ventricular function.

Results

Renal RI was significantly higher in subjects with diastolic dysfunction (0.72 ± 0.05) when compared with those who had a normal TTE examination (0.66 ± 0.06, p < 0.01). Renal RI values were correlated with markers of diastolic dysfunction including the E/Vp ratio (r = 0.41, p < 0.001), left atrial area (r = 0.36, p < 0.001), the E/A ratio (r = 0.36, p < 0.001) and the E/E' ratio (r = 0.31, p < 0.001). These associations were independent of systolic function, hypertension, the presence and severity of chronic kidney disease, the use of renin-angiotensin inhibitors and other potentially confounding variables.

Conclusion

Increasing vascular resistance of the intrarenal arteries was associated with markers of diastolic dysfunction in subjects with type 2 diabetes. These findings are consistent with the hypothesis that vascular and cardiac stiffening in diabetes are manifestations of common pathophysiological mechanisms.  相似文献   

16.

Purpose

To study age-related changes of intraocular pressure (IOP) and assess the cohort effect in both cross-sectional and longitudinal settings among elderly Chinese adults.

Methods

Participants were enrolled from the Lingtou Eye Cohort Study with Chinese government officials aged 40 years and older at baseline and received physical check-up and ocular examinations from 2010 to 2012. IOP was measured using a non-contact tonometer according to standardized protocols, as well as systolic blood pressure (SBP), diastolic blood pressure (DBP) and body mass index (BMI). Participants who had attended IOP measurements in both 2010 and 2012 were included in this study. Cross-sectional association of IOP with age was assessed using multivariate liner regression analyses and based on the data of 2010. Longitudinal changes in IOP were assessed by paired t-test.

Results

A total of 3372 subjects were enrolled in the current analysis (2010 mean [SD] age, 61.9 [7.1] years; 60.2% men). The mean IOP in 2010 was 15.4±2.3 mmHg for women and 15.2±2.3 mmHg for men with an intersex difference (P = 0.029). Cross-sectional analysis showed that IOP was negatively associated with age (P = 0.003, β = -0.033 for women and P<0.001, β = -0.061 for men) adjusted for baseline SBP, DBP and BMI. Paired t-test suggested that IOP was higher in the year 2012 than 2010 in women (P = 0.006) but did not change significantly in men within 2 years (P = 0.345). In addition, the 2-year changes of IOP were not associated with age adjusted for baseline IOP in 2010 (P = 0.249).

Conclusion

Cross-sectional data suggests that IOP is lower in people with older age. Longitudinal data does not support such findings and thus the identified decreasing pattern with age in cross-sectional analysis is likely caused by cohort effects.  相似文献   

17.

Background

The aim of the present study was to explore the occurrence of fibrocytes in tissue and to investigate whether the appearance of fibrocytes may be linked to structural changes of the parenchyme and vasculature in the lungs of patients with obliterative bronchiolitis (OB) following lung or bone marrow transplantation.

Methods

Identification of parenchyme, vasculature, and fibrocytes was done by histological methods in lung tissue from bone marrow or lung-transplanted patients with obliterative bronchiolitis, and from controls.

Results

The transplanted patients had significantly higher amounts of tissue in the alveolar parenchyme (46.5 ± 17.6%) than the controls (21.7 ± 7.6%) (p < 0.05). The patients also had significantly increased numbers of fibrocytes identified by CXCR4/prolyl4-hydroxylase, CD45R0/prolyl4-hydroxylase, and CD34/prolyl4-hydroxylase compared to the controls (p < 0.01). There was a correlation between the number of fibrocytes and the area of alveolar parenchyma; CXCR4/prolyl 4-hydroxylase (p < 0.01), CD45R0/prolyl 4-hydroxylase (p < 0.05) and CD34/prolyl 4-hydroxylase (p < 0.05). In the pulmonary vessels, there was an increase in the endothelial layer in patients (0.31 ± 0.13%) relative to the controls (0.037 ± 0.02%) (p < 0.01). There was a significant correlation between the number of fibrocytes and the total area of the endothelial layer CXCR4/prolyl 4-hydroxylase (p < 0.001), CD45R0/prolyl 4-hydroxylase (p < 0.001) and CD34/prolyl 4-hydroxylase (p < 0.01). The percent areas of the lumen of the vessels were significant (p < 0.001) enlarged in the patient with OB compared to the controls. There was also a correlation between total area of the lumen and number of fibrocytes, CXCR4/prolyl 4-hydroxylase (p < 0.01), CD45R0/prolyl 4-hydroxylase (p < 0.001) and CD34/prolyl 4-hydroxylase (p < 0.01).

Conclusion

Our results indicate that fibrocytes are associated with pathological remodelling processes in patients with OB and that tissue fibrocytes might be a useful biomarker in these processes.  相似文献   

18.
Effect of cornea material stiffness on measured intraocular pressure   总被引:1,自引:1,他引:0  
Intraocular pressure (IOP) in the human eye as measured by a Goldmann applanation tonometer (GAT) is known to be affected by individual differences in central corneal thickness (CCT). However, data from clinical studies also show considerable scatter in the correlation between measured IOP and CCT. One possible implication of the large observed scatter is that the true IOP (IOPT) also depends significantly on individual variations in the material stiffness properties of the cornea. This hypothesis is explored and evaluated herein using computational simulation of applanation tonometry. A simplified 2D finite element model of the eye, which employs a calibrated nonlinear transversely isotropic material model for the cornea, is developed, and a series of GAT simulations is carried out to study the effect of geometry and material properties of the cornea on the IOP readings obtained via GAT. The results of this parametric study provide a simple correction equation, which quantifies the effect on measured IOP of variations in CCT and corneal material stiffness. In addition, several previously proposed IOP correction equations are compared with the one proposed here.  相似文献   

19.

Background

Biventricular (Biv) pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP) assessment by radial artery tonometry in guiding Biv pacemaker optimization.

Methods

Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV) ejection fraction (EF) 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI), ejection time (ET), myocardial performance index (MPI), radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated.

Results

Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p < 0.001), LV VTI (15.9 ± 4.8 cm to 18.4 ± 5.1 cm, p < 0.001) and MPI (0.57 ± 0.2 to 0.45 ± 0.13, p < 0.001) and in PEP (246.7 ± 36.1 ms to 234.7 ± 35.5 ms, p = 0.003), PEP/ET (0.88 ± 0.21 to 0.79 ± 0.17, p < 0.001), and PEP/VTI (17.3 ± 7 to 13.78 ± 4.7, p < 0.001). The correlation between comprehensive echo Doppler and radial artery tonometry-PEP guided optimal atrioventricular delay (AVD) and optimal interventricular delay (VVD) was 0.75 (p < 0.001) and 0.69 (p < 0.001) respectively. In 29 patients with follow up assessment, New York Heart Association (NYHA) class reduced from 2.5 ± 0.8 to 2.0 ± 0.9 (p = 0.004) at 1.8 ± 1.4 months.

Conclusion

An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.  相似文献   

20.

Purpose

To compare estimates of 24-hour intraocular pressure (IOP) peak timing and variation obtained using a contact lens sensor (CLS) and using a pneumatonometer.

Methods

Laboratory data collected from 30 healthy volunteers (ages, 20-66 years) in a randomized, controlled clinical trial were analyzed. Participants were housed for 24 hours in a sleep laboratory. One randomly selected right or left eye was fitted with a CLS that monitored circumferential curvature in the corneoscleral region related to the change of IOP. Electronic output signals of 30 seconds were averaged and recorded every 5 minutes. In the contralateral eye, habitual IOP measurements were taken using a pneumatonometer once every two hours. Simulated 24-hour rhythms in both eyes were determined by cosinor fitting. Simulated peak timings (acrophases) and simulated data variations (amplitudes) were compared between the paired eyes.

Results

Bilateral change patterns of average 24-hour data for the group were in parallel. The simulated peak timing in the CLS fitted eye occurred at 4:44 AM ± 210 min (mean ± SD) and the IOP peak timing in the contralateral eye at 4:11 AM ± 120 min (P=0.256, Wilcoxon signed-rank test). There was no significant correlation between the simulated data variations in the paired eyes (P=0.820, linear regression).

Conclusions

The 24-hour CLS data showed a simulated peak timing close to the 24-hour IOP peak timing obtained using the pneumatonometer. However, the simulated variations of 24-hour data in the paired eyes were not correlated. Estimated 24-hour IOP rhythms using the two devices should not be considered interchangeable.  相似文献   