首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Phosphorylation of rodent cardiac myosin light chain 2: effects of exercise   总被引:1,自引:0,他引:1  
The purpose of this study was to ascertain whether the degree of cardiac myosin light chain 2 (P-light chain) phosphorylation occurs as a function of changes in cardiovascular functional state as induced by 1) treadmill exercise (20-27 m/min, 0% grade for 20, 30, 45 min) (phase I) and 2) pharmacological intervention (phase II) in adult female Sprague-Dawley rats. It was hypothesized that cardiac myosin phosphorylation is regulated in accordance with time-dependent sustained elevations in myocardial work demands requiring alterations in either heart rate or left ventricular pressure development. Exercise heart rates (HR) and double products (HR x DP) were equivalent among the three exercise groups and were significantly elevated in comparison with the normal-rest (NR) group (P less than 0.05). In phase II, isoproterenol elicited higher HR, although the atenolol group exhibited a marked reduction in HR, mean arterial pressure, and double product relative to NR (P less than 0.05). Percent myosin P-light chain phosphorylation exhibited both a HR- and a work load-dependent modulation in P-light chain levels (-9% to +23% change) in the two phases of the study (P less than 0.05). These data are consistent with the view that the above responses are associated with modulations in intracellular calcium concentrations commensurate with the alterations in HR and left ventricular pressure. Also, elevations in P-light chain phosphorylation could serve to augment left ventricular pressure development under these functional states.  相似文献   

2.
Left ventricular functional capacity in the endurance-trained rodent   总被引:3,自引:0,他引:3  
Cardiac myosin P-light chain phosphorylation [P-LC(P)] has been proposed to augment myocardial force production. This study was undertaken to examine the potential for cardiac myosin P-LC(P) for both equivalent heart rate and work load in exercising endurance-trained and nontrained rodents. A 10-wk training protocol elicited a significant reduction in submaximal running O2 uptake while enhancing peak O2 uptake (-17 and 10%, respectively, P less than 0.05). Left ventricular functional index during submaximal exercise, obtained with a high-fidelity Millar ultraminiature pressure transducer, indicated that the trained animals were able to maintain peak left ventricular pressure (LVP) in comparison to their sedentary counterparts, even though both heart rate and rate of LVP development were significantly reduced (P less than 0.05). When expressed on the basis of equivalent submaximal heart rate, peak LVP was augmented in the trained animals. Cardiac myosin P-LC(P) was examined under two conditions known to produce disparate responses in trained vs. sedentary animals. For an equivalent work load, we observed parallel increases in P-LC(P) (20%) and systolic pressure (17%) in both groups, even though the trained animals exhibited significantly lower heart rates (P less than 0.05). For an equivalent heart rate, training evoked a significant increase in systolic pressure (26%, P less than 0.05) and caused a slight increase in P-LC(P) relative to the nontrained controls. Cardiac myosin adenosinetriphosphatase was reduced approximately 10% in the trained animals (P less than 0.05), commensurate with a 2.0-fold increase in the V3 (low adenosinetriphosphatase) isomyosin.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
The effects of beta-adrenergic blockade upon myocardial blood flow and oxygen balance during exercise were evaluated in eight conscious dogs, instrumented for chronic measurements of coronary blood flow, left ventricular pressure, aortic blood pressure, heart rate, and sampling of arterial and coronary sinus venous blood. The administration of propranolol (1.5 mg/kg iv) produced a decrease in heart rate, peak left ventricular (LV) dP/dt, LV (dP/dt/P, and an increase in LV end-diastolic pressure during exercise. Mean coronary blood flow and myocardial oxygen consumption were lower after propranolol than at the same exercise intensity in control conditions. The oxygen delivery-to-oxygen consumption ratio and the coronary sinus oxygen content were also significantly lower. It is concluded that the relationship between myocardial oxygen supply and demand is modified during exercise after propranolol, so that a given level of myocardial oxygen consumption is achieved with a proportionally lower myocardial blood flow and a higher oxygen extraction.  相似文献   

4.
Temporary sequential biventricular pacing (BiVP) is a promising treatment for postoperative cardiac dysfunction, but the mechanism for improvement in right ventricular (RV) dysfunction is not understood. In the present study, cardiac output (CO) was optimized by sequential BiVP in six anesthetized, open-chest pigs during control and acute RV pressure overload (RVPO). Ventricular contractility was assessed by the maximum rate of increase of ventricular pressure (dP/dt(max)). Mechanical interventricular synchrony was measured by the area of the normalized RV-left ventricular (LV) pressure diagram (A(PP)). Positive A(PP) indicates RV pressure preceding LV pressure, whereas zero indicates complete synchrony. In the control state, CO was maximized with nearly simultaneous stimulation of the RV and LV, which increased RV (P = 0.006) and LV dP/dt(max) (P = 0.002). During RVPO, CO was maximized with RV-first pacing, which increased RV dP/dt(max) (P = 0.007), but did not affect LV dP/dt(max), and decreased the left-to-right, end-diastolic pressure gradient (P = 0.023). Percent increase of RV dP/dt(max) was greater than LV dP/dt(max) (P = 0.014). There were no increases in end-diastolic pressure to account for increases in dP/dt(max). In control and RVPO, RV dP/dt(max) was linearly related to A(PP) (r = 0.779, P < 0.001). The relation of CO to A(PP) was curvilinear, with a peak in CO with positive A(PP) in the control state (P = 0.004) and with A(PP) approaching zero during RVPO (P = 0.001). These observations imply that, in our model, BiVP optimization improves CO by augmenting RV contractility. This is mediated by changes in mechanical interventricular synchrony. Afterload increases during RVPO exaggerate this effect, making CO critically dependent on simultaneous pressure generation in the RV and LV, with support of RV contractility by transmission of LV pressure across the interventricular septum.  相似文献   

5.
Twitch tension and maximal unloaded velocity of human knee extensor muscles were studied under conditions of low phosphate content of the phosphorylatable light chains (P-light chains) of myosin and elevated phosphate content, following a 10-s maximal voluntary isometric contraction (MVC). After the MVC, twitch tension was significantly potentiated, with greater potentiation observed at a shorter muscle length (p less than 0.05). The MVC was associated with at least a twofold increase in phosphate content of the fast (LC2F) and two slow (LC2S and LC2S') P-light chains, but this increase was unrelated to muscle length. No significant differences in knee extension velocity were observed between conditions where P-light chains had low or elevated phosphate content. Positive but nonsignificant correlations were noted between the extent of twitch potentiation and phosphate content of individual P-light chains as well as the percentage of type II muscle fibres in vastus lateralis muscle. No significant relationships were determined for myosin light chain kinase activity and either P-light chain phosphorylation or type II fibre percentage. These data suggest that, unlike other mammalian fast muscles, P-light chain phosphorylation of mixed human muscles is not strongly associated with altered contractile performance.  相似文献   

6.
To determine whether endogenous opiates have a role in circulatory regulation during mild to moderate exercise, 11 chronically instrumented dogs were exercised on a treadmill up a 6% incline at 2.5 and 5.0 mph, each for 20 min, after treatment with either the opiate receptor antagonist naloxone (1 mg/kg bolus and 20 micrograms.kg-1.min-1 infusion) or normal saline. Naloxone increased plasma beta-endorphin and adrenocorticotropic hormone at rest but had no effect on resting heart rate, aortic pressure, cardiac output, left ventricular time derivative of pressure (dP/dt) and ratio of dP/dt at a developed pressure of 50 mmHg and the developed pressure (dP/dt/P), or plasma catecholamines. Plasma beta-endorphin and adrenocorticotropic hormone increased during exercise. In addition, graded treadmill exercise produced proportional increases in heart rate, cardiac output, aortic pressure, left ventricular dP/dt and dP/dt/P, and blood flow to exercising muscles, right and left ventricular myocardium, and adrenal glands. However, there were no differences in the circulatory responses to exercise between animals receiving naloxone and normal saline. Thus the endogenous opiate system probably does not play an important role in regulating the systemic hemodynamic and blood flow responses to mild and moderate exercise.  相似文献   

7.
This study was undertaken to determine biochemical and functional (in vivo) adaptations of the rodent neonatal heart in response to a training program of endurance running. Ten day-old rats were progressively trained on a treadmill (final intensity, 21 m/min, 30% grade, 1 h/day) until 75 days of age. The training program induced 14, 57, and 24% increases in relative heart mass, skeletal muscle citrate synthase activity, and whole-body maximal O2 uptake, respectively (P less than 0.05). Cardiac myosin (ATPase) and Ca2+-regulated myofibril ATPase were both reduced by approximately 15% in trained vs. sedentary animals (P less than 0.05). In the majority of trained hearts examined, the myosin isozyme profile reflected an estimated 14 +/- 3% shift toward the V3 or low ATPase isozyme. Left ventricular functional indices during submaximal exercise, derived from a fluid-filled indwelling cannula, indicated that the trained animals maintained similar left ventricular (LV) systolic pressure, LV + the time derivative of pressure, and systemic arterial mean blood pressure compared with their sedentary counterparts. These functional parameters were maintained even though the trained animals performed with lower submaximal exercise heart rate. These findings suggest that maximal exercise capacity can be enhanced in neonatal rats even though the biochemical potential for ATP degradation in the cardiac contractile system is lowered. We speculate that the trend to maintain the myosin isozyme pattern further in the direction of the V3 isozyme in the trained neonatal rat heart may reflect a means to economize cross-bridge cycling while maintaining normal levels of ventricle performance at a given submaximal work load.  相似文献   

8.
The present study evaluated the impact of moderate exercise training on the cardiac tolerance to acute pressure overload. Male Wistar rats were randomly submitted to exercise training or sedentary lifestyle for 14 wk. At the end of this period, the animals were anaesthetized, mechanically ventilated, and submitted to hemodynamic evaluation with biventricular tip pressure manometers. Acute pressure overload was induced by banding the descending aorta to induce a 60% increase of peak systolic left ventricular pressure during 120 min. This resulted in the following experimental groups: 1) sedentary without banding (SED + Sham), 2) sedentary with banding (SED + Band), and 3) exercise trained with banding (EX + Band). In response to aortic banding, SED + Band animals could not sustain the 60% increase of peak systolic pressure for 120 min, even with additional narrowing of the banding. This was accompanied by a reduction of dP/dt(max) and dP/dt(min) and a prolongation of the time constant tau, indicating impaired systolic and diastolic function. This impairment was not observed in EX + Band (P < 0.05 vs. SED + Band). Additionally, compared with SED + Band, EX + Band presented less myocardial damage, exhibited attenuated protein expression of active caspase-3 and NF-κB (P < 0.016), and showed less protein carbonylation and nitration (P < 0.05). These findings support our hypothesis that exercise training has a protective role in the modulation of the early cardiac response to pressure overload.  相似文献   

9.
We have studied the effect of myosin P-light chain phosphorylation on the isometric tension generated by skinned fibers from rabbit psoas muscle at 0.6 and 10 microM Ca2+. At the lower Ca2+ concentration, which produced 10-20% of the maximal isometric tension obtained at 10 microM Ca2+, addition of purified myosin light chain resulted in a 50% increase in isometric tension which correlated with an increase in P-light chain phosphorylation from 0.10 to 0.80 mol of phosphate/mol of P-light chain. Addition of a phosphoprotein phosphatase reversed the isometric tension response and dephosphorylated P-light chain. At the higher Ca2+ concentration, P-light chain phosphorylation was found to have little effect on isometric tension. Fibers prepared and stored at -20 degrees C in a buffer containing MgATP, KF, and potassium phosphate incorporated 0.80 mol of phosphate/mol of P-light chain. Addition of phosphoprotein phosphatase to these fibers incubated at 0.6 microM Ca2+ caused a reduction in isometric tension and dephosphorylation of the P-light chain. There was no difference before and after phosphorylation of P-light chain in the normalized force-velocity relationship for fibers at the lower Ca2+ concentration, and the extrapolated maximum shortening velocity was 2.2 fiber lengths/s. Our results suggest that in vertebrate skeletal muscle, P-light chain phosphorylation increases the force level at submaximal Ca2+ concentrations, probably by affecting the interaction between the myosin cross-bridge and the thin filament.  相似文献   

10.
Concern about the effects of anesthesia on physiological measurements led us to develop methodology to assess left ventricular (LV) pressure in conscious mice. Polyethylene-50 tubing filled with heparinized saline was implanted in the LV cavity through its apex via an abdominal approach and exteriorized to the back of the animal. This surgery was done under anesthesia with either an intraperitoneal injection of ketamine (80 mg/kg) and xylazine (5 mg/kg) (K+X) in 11 mice or isoflurane (ISF; 1.5 vol%) by inhalation in 14 mice. Postoperatively, mice were trained daily to lie quietly head first in a plastic cone. LV pressure, the first derivative of LV pressure (dP/dt), and heart rate (HR) in the conscious state were compared between the two groups at 3 days and 1 wk after recovery from surgery using a 1.4-Fr Millar catheter inserted into the LV through the tubing, with the mice lying quietly in the plastic cone. Acutely during anesthesia, K+X decreased HR (from 698 to 298 beats/min), LV systolic pressure (from 107 to 65 mmHg), and maximal dP/dt (dP/dt(max)) (from 15,724 to 4,445 mmHg/s), all P < 0.01. Similar but less marked negative chronotropic and inotropic effects were seen with ISF. HR and dP/dt(max) were decreased significantly in K+X mice 3 days after surgery compared with those anesthetized with ISF (655 vs. 711 beats/min, P < 0.05; 14,448 vs. 18,048 mmHg/s, P < 0.001) but increased to the same level as in ISF mice 1 wk after surgery. In ISF mice, recovery of function occurred rapidly and there were no differences in LV variables between 3 days and 1 wk. LV pressure and dP/dt can be measured in conscious mice with a micromanometer catheter inserted through tubing implanted permanently in the LV apex. Anesthesia with either K+X or, to a lesser extent, ISF, depressed LV function acutely. This depression of function persisted for 3 days after surgery with K+X (but not ISF) and did not recover completely until 1 wk postanesthesia.  相似文献   

11.
We examined the effects of gender and aging on cardiac and peripheral hemodynamic responses to beta-adrenergic receptor (beta-AR) stimulation in young (male = 5.9 +/- 0.4 yr old and female = 6.5 +/- 0.7 yr old) and old (male = 19.8 +/- 0.7 yr old and female = 21.2 +/- 0.2 yr old) conscious monkeys (Macaca fascicularis), chronically instrumented for measurements of left ventricular (LV) and arterial pressures as well as cardiac output. Baseline LV pressure, the first derivative of LV pressure (LV dP/dt), cardiac index, mean arterial pressure, total peripheral resistance (TPR), and heart rate in conscious monkeys were not different among the four groups. Increases in LV dP/dt in response to 0.1 microg/kg isoproterenol (Iso) were diminished (P < 0.05) in old males (+99 +/- 11%) compared with young males (+194 +/- 18%). In addition, the inotropic responses to norepinephrine (NE) and forskolin (FSK) were significantly depressed (P < 0.05) in old males. Iso-induced reductions of TPR were less (P < 0.05) in old males (-28 +/- 2%) than in young males (-49 +/- 2%). The changes of TPR in response to NE and FSK were also significantly attenuated (P < 0.05) in old males. However, the LV dP/dt responses to BAY y 5959 (15 microg. kg-1. min-1), a Ca2+ channel promotor independent of beta-AR signaling, were not significantly different between old and young males. In contrast to results in male monkeys, LV dP/dt and TPR responses to Iso, NE, and FSK in old females were similar to those observed in young females. Thus both cardiac contractile and peripheral vascular dynamic responses to beta-AR stimulation are preserved in old female but not old male monkeys. This may explain, in part, the reduced cardiovascular risk in the older female population.  相似文献   

12.
Left ventricular hemodynamics during exercise recovery   总被引:1,自引:0,他引:1  
The directional response of human left ventricular stroke volume during exercise recovery is unclear. Stroke volume has been reported to increase and decrease over exercise values during early recovery. The confounding variable may be posture. With the use of pulsed Doppler ultrasound, we tested the hypothesis that there is a significant difference between seated and supine stroke index (SI) during passive recovery from seated ergometer exercise. Thirteen subjects aged 26 +/- 2 yr performed two seated cycle ergometer exercise tests to 70% of predicted maximum heart rate (HR). Recovery was supine on one test and seated on the other. Cardiac index (CI), HR, and SI were calculated during rest, exercise, and 10 min of recovery. At rest, SI and CI were significantly (P less than 0.01) less and HR significantly (P less than 0.01) greater when the subjects were seated than when they were supine. At the last exercise work load, no significant differences were found in any measured variable between tests. During recovery, supine SI was maximal 180 s postexercise (99 +/- 14 ml/m2) and exceeded (P less than 0.01) resting supine (81 +/- 14 ml/m2) and peak exercise (77 +/- 14 ml/m2) SI by 22 and 29%, respectively. Seated SI was constant at peak exercise levels for 2 min. Seated and supine recovery CI never exceeded exercise values. Systolic and diastolic blood pressure recovery curves were similar in the two postures. We conclude that posture significantly affects SI during recovery from submaximal seated exercise. These results have implications for choice of recovery posture after stress testing in cardiac patients where it is desirable to minimize ventricular loading.  相似文献   

13.
Among the various cardiac contractility parameters, left ventricular (LV) ejection fraction (EF) and maximum dP/dt (dP/dt(max)) are the simplest and most used. However, these parameters are often reported together, and it is not clear if they are complementary or redundant. We sought to compare the discriminative value of EF and dP/dt(max) in assessing systolic dysfunction after myocardial infarction (MI) in swine. A total of 220 measurements were obtained. All measurements included LV volumes and EF analysis by left ventriculography, invasive ventricular pressure tracings, and echocardiography. Baseline measurements were performed in 132 pigs, and 88 measurements were obtained at different time points after MI creation. Receiver operator characteristic (ROC) curves to distinguish the presence or absence of an MI revealed a good predictive value for EF [area under the curve (AUC): 0.998] but not by dP/dt(max) (AUC: 0.69, P < 0.001 vs. EF). Dividing dP/dt(max) by LV end-diastolic pressure and heart rate (HR) significantly increased the AUC to 0.87 (P < 0.001 vs. dP/dt(max) and P < 0.001 vs. EF). In na?ve pigs, the coefficient of variation of dP/dt(max) was twice than that of EF (22.5% vs. 9.5%, respectively). Furthermore, in n = 19 pigs, dP/dt(max) increased after MI. However, echocardiographic strain analysis of 23 pigs with EF ranging only from 36% to 40% after MI revealed significant correlations between dP/dt(max) and strain parameters in the noninfarcted area (circumferential strain: r = 0.42, P = 0.05; radial strain: r = 0.71, P < 0.001). In conclusion, EF is a more accurate measure of systolic dysfunction than dP/dt(max) in a swine model of MI. Despite the variability of dP/dt(max) both in na?ve pigs and after MI, it may sensitively reflect the small changes of myocardial contractility.  相似文献   

14.
This study explores the use of interventricular asynchrony (interVA) for optimizing cardiac resynchronization therapy (CRT), an idea emerging from a simple pathway model of conduction in the ventricles. Measurements were performed in six dogs with chronic left bundle branch block (LBBB) and in 29 patients of the Pacing Therapies for Congestive Heart Failure (PATH-CHF)-I study. In the dogs, intraventricular asynchrony (intraVA) was determined using left ventricular (LV) endocardial activation maps. In dogs and patients, the maximum rate of rise of LV pressure (LV dP/dt(max)) and the pulse pressure (PP) and interVA [time delay between upslope of LV and right ventricular (RV) pressure curves] were measured during LV, RV, and biventricular (BiV) pacing with various atrioventricular (AV) delays. Measurements in the canine hearts supported the pathway model in that optimal resynchronization occurred at approximately 50% reduction of intraVA and at an interVA value halfway that during LBBB and LV pacing. In patients with significant hemodynamic response during pacing (n = 22), intrinsic interVA and interVA at peak improvement (interVA(p)) varied widely between patients (from -83 to -15 ms and from -42 to +31 ms, respectively). However, the model predicted individual interVA(p) accurately (SD of +/-6 ms and +/-12 ms for LV dP/dt(max) and PP, respectively). At equal interVA, LV and BiV pacing produced equal hemodynamic response, but in 11 of 22 responders, BiV pacing reduced interVA insufficiently to reach the maximum hemodynamic response. LV pacing at short AV delay proved to result in better hemodynamics than predicted by the model, indicating that additional factors determine hemodynamics during LV preexcitation. Guided by a simple pathway model, interVA measurements accurately predict optimal hemodynamic performance in individual CRT patients.  相似文献   

15.
The effect of changes in muscle length on post-tetanic isometric twitch tension potentiation and myosin P-light chain phosphorylation-was studied at 23°C in the mouse extensor digitorum longus muscle. The length-tension relationship was determined for the same muscles after a 30 min period of quiescence and between 30 s and 3 min after a 1.5 s tetanus at L0. Isometric twitch tension is increased at all muscle lengths after the tetanus; however, the fractional increase in twitch tension rises from 0.2 at L0 to a maximum of 0.3 at 1.2 L0. The fractional increase in twitch tension measured at any fixed muscle length is constant between 30 s and 3 min post-tetanus. P-light chain phosphorylation remains constant between 30 s and 3 min post-tetanus followed by a slow decline to basal values. Under fixed length conditions, there is linear relationship between the relative magnitude of the twitch tension and the extent of P-light chain phosphor-ylation. Net myosin phosphorylalion measured after a 1.5 s tetanus at 1.23 L0 is 35% less than that obtained under the same conditions at L0. Thus, contraction-induced phosphorylation of P-light chain decreases with increased muscle length and post-tetanic potentiation at a constant level of P-light chain phosphorylation increases with increasing muscle length. These observations may be consistent with alterations in the sarcoplasmic Ca2+ ion transient as the muscle is lengthened.  相似文献   

16.
Left ventricular (LV) twist is thought to play an important role in cardiac function. However, how twist affects systolic or diastolic function is not understood in detail. We acquired apical and basal short-axis images of dogs undergoing open-chest procedures (n = 15) using a GE Vivid 7 at baseline and during the use of an apical suction device (Starfish) to limit apical rotation. We measured LV pressure and stroke volume using a micromanometer-tipped catheter and an ultrasonic flow probe, respectively. Peak radial strain, peak rotation, peak twist, peak systolic twisting rate (TR), peak untwisting rate during isovolumic relaxation period (UR(IVR)), and peak early diastolic untwisting rate after mitral valve opening (UR(E)) were determined using speckle tracking echocardiography. Immobilizing the apex with gentle suction significantly decreased apical rotation (-50 ± 27%) and slightly increased basal rotation, resulting in a significant decrease in twist. The time constant of LV relaxation (τ) was prolonged, and LV end-diastolic pressure increased. TR and UR(IVR) decreased. LV systolic pressure, peak positive and negative first derivative of LV pressure (±dP/dt), stroke volume, radial strain, and UR(E) were not changed. The correlation between τ and UR(IVR) (r = 0.63, P = 0.0006) was stronger than that between peak +dP/dt and TR (r = 0.46, P = 0.01). Diastolic function was impaired with reduced apical rotation and UR(IVR) when the apex of the heart was immobilized using an apical suction device.  相似文献   

17.
Left ventricular (LV) diastolic function during atrial fibrillation (AF) remains poorly understood due to the complex interaction of factors and beat-to-beat variability. The purpose of the present study was to elucidate the physiological determinants of beat-to-beat changes in LV diastolic function during AF. The RR intervals preceding a given cardiac beat were measured from the right ventricular electrogram in 12 healthy open-chest mongrel dogs during AF. Doppler echocardiography and LV pressure and volume beat-to-beat analyses were performed. The LV filling time (FT) and early diastolic mitral inflow velocity-time integral (E(vti)) were measured using the pulsed Doppler method. The LV end-diastolic volume (EDV), peak systolic LV pressure (LVP), minimum value of the first derivative of LV pressure curve (dP/dt(min)), and the time constant of LV pressure decay (tau) were evaluated with the use of a conductance catheter for 100 consecutive cardiac cycles. Beat-to-beat analysis revealed a cascade of important causal relations. LV-FT showed a significant positive linear relationship with E(vti) (r = 0.87). Importantly, there was a significant positive linear relationship between the RR interval and LV-EDV in the same cardiac beat (r = 0.53). Consequently, there was a positive linear relationship between LV-EDV and subsequent peak systolic LVP (r = 0.82). Furthermore, there were significant positive linear and negative curvilinear relationships between peak systolic LVP and dP/dt(min) (r = 0.95) and tau (r = -0.85), respectively, in the same cardiac beat. In addition, there was a significant negative curvilinear relationship between dP/dt(min) and tau (r = -0.86). We have concluded that the determinants of LV diastolic function in individual beats during AF depend strongly on the peak systolic LVP. This suggests that the major benefit of slower ventricular rate appears related to lengthening of LV filling interval, promoting subsequent higher peak systolic LVP and greater LV relaxation.  相似文献   

18.
Previous in vivo and in vitro experiments have demonstrated increased cardiac contractility and increased total myocardial blood flow (Qmyocardial) when rats were exposed to normoxic 5-bar (500 kPa) ambient pressure. In the present study, regional blood flow was measured using the microsphere method on nine anaesthetized cats at surface and normoxic 5-bar (500 kPa) ambient pressure. Left ventricular pressure (LVP) and cardiac contractility, measured as peak left ventricular +dP/dt and -dP/dt were measured in six of the cats. Arterial pressure, heart rate and cardiac output remained unchanged after compression, but total Qmyocardial increased by 29% (P less than 0.01) and cerebral blood flow increased by 66% (P less than 0.05). At the same time +dP/dt and -dP/dt was increased by 83% and 102%, respectively (P less than 0.01), while LVP was enhanced by 14% (P less than 0.05). Except for a moderate decrease in partial pressure of oxygen, acid base status in arterial blood remained unchanged. The results indicate that the effects of increased ambient pressure on the heart are general physiological phenomena, which are not only limited to the laboratory rat.  相似文献   

19.
Analysis of postextrasystolic relaxation response in the human heart   总被引:1,自引:0,他引:1  
Postextrasystolic potentiation is the phenomenon in which ventricular contractile force is strengthened by a preceding premature beat. However, the response of diastolic function after an extrasystole is unknown. We studied 58 patients with chronic heart failure (CHF) and two control subjects to evaluate the response of relaxation following extrasystole. At cardiac catheterization, from the derivative of the left ventricular (LV) pressure, the ratio of LV peak negative dP/dt (–dP/dt) of a postextrasystole to a basal beat was calculated and defined as the postextrasystolic relaxation response (PRR). PRR was compared with parameters of left ventriculography: LV end-diastolic volume index (EDVI), LV end-systolic volume index (ESVI), and LV ejection fraction (EF). The PRRs of the two control subjects were 0.80 and 0.84. The mean PRR of the CHF patients was 0.99 ± 0.15. In all subjects, including patients and controls, correlation analysis between (EDVI, ESVI, and EF) and PRR yielded the following: (a) EDVI vs. PRR: R = 0.273, p = 0.036; (b) ESVI vs. PRR: R = 0.446, p < 0.001; and (c) EF vs. PRR: R = –0.520, p < 0.001. Thus, normal or non-failing human hearts showed a decline of –dP/dt in postextrasystole compared with the basal beats, but failing hearts had potentiated relaxation following an extrasystole.  相似文献   

20.
Recently, attention has been focused on comparing left ventricular (LV) endocardial (ENDO) with epicardial (EPI) pacing for cardiac resynchronization therapy. However, the effects of ENDO and EPI lead placement at multiple sites have not been studied in failing hearts. We hypothesized that differences in the improvement of ventricular function due to ENDO vs. EPI pacing in dyssynchronous (DYSS) heart failure may depend on the position of the LV lead in relation to the original activation pattern. In six nonfailing and six failing dogs, electrical DYSS was created by atrioventricular sequential pacing of the right ventricular apex. ENDO was compared with EPI biventricular pacing at five LV sites. In failing hearts, increases in the maximum rate of LV pressure change (dP/dt; r = 0.64), ejection fraction (r = 0.49), and minimum dP/dt (r = 0.51), relative to DYSS, were positively correlated (P < 0.01) with activation time at the LV pacing site during ENDO but not EPI pacing. ENDO pacing at sites with longer activation delays led to greater improvements in hemodynamic parameters and was associated with an overall reduction in electrical DYSS compared with EPI pacing (P < 0.05). These findings were qualitatively similar for nonfailing hearts. Improvement in hemodynamic function increased with activation time at the LV pacing site during ENDO but not EPI pacing. At the anterolateral wall, end-systolic transmural function was greater with local ENDO compared with EPI pacing. ENDO pacing and intrinsic activation delay may have important implications for management of DYSS heart failure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏