首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An automated capillary microinjection system for nuclear and cytoplasmic injections into cells is described. The system has been tested with samples of DNA, RNA and proteins. Movements of the capillary with precise cell positioning and time of injections are controlled by a computer. This first automated microinjection system allows injection of more than 1500 cells per hour with a minimum of practical training, volumes injected are more reproducible and cells are less damaged when compared with the standard manual injection technique. Retrieval of the injected cells is accurate to within 1% without complicated and laborious produced orientation marks on the cell support. The number of successfully injected cells is easily determined with great accuracy and the error of the statistical evaluation of the results is reduced to a minimum. Standardized procedures for pulling, handling and storage of the injection capillaries were developed.  相似文献   

2.
An improved capillary liquid chromatography procedure, incorporating column switching in combination with mass spectrometry, is reported. The dual column system allows for rapid inject-to-inject cycle times to improve the speed of protein identification for proteomics applications. Full gradient elution of peptides from either of the two C18 columns can be achieved in less than 17 min while maintaining sufficient resolution for the peptides to be detected and fragmented by the mass spectrometer for protein identification. Importantly, the use of two columns for subsequent injections is reproducible and without carry-over. The limit of detection for the system is between 25 and 50 fmol per injection. This fully automated system is capable of analyzing and identifying proteins from an entire 96-well plate in about 27 h.  相似文献   

3.
Testing in vitro is an alternative to animal experimentation. The capillary pressure microinjection technique is a supporting technology for efficient in vitro testing. The main benefit of the technique is the possibility of injecting large molecules into a single living cell. The ultimate goal of the research discussed in this paper is to increase the cell survival rate in capillary pressure microinjection. A method to reliably evaluate cell survival rate is therefore needed. A three-phase evaluation process is presented in this paper. The first phase determines the success rate of the injection capillary to penetrate the cell membrane. The second phase studies the success rate of delivering the injection substance inside the cell, while the third phase studies cell survival after the microinjection. In addition to the three-phase evaluation process, this paper describes the initial results of penetration and injection tests performed by using a semi-automatic capillary pressure microinjection system developed by the research group. Three adherent cell lines, namely, retinal pigment epithelial cells, MCF-7 human breast cancer cells and SH-SY5Y neuroblastoma cells, were used in the experiments. The results of the penetration tests show that the average success rate of penetrating the cell membrane using the micromanipulator was 87%. The goal of the injection tests was to demonstrate the successful microinjection of living cells and to study the injection success rate. Fluorescein dextran was injected into MCF-7 cells, and preliminary results showed an injection success rate of 49%. In the survival tests, the neuronal cells were microinjected with KCl. During long-term observation after the microinjection, the microinjected cells first decreased their adhesion to the plate, but later adhered to the bottom of the plate and even grew some dendrites. In the next phase of the study, more tests will be performed in order to obtain a statistically reliable value for the survival rate.  相似文献   

4.
Intracellular fate of ferritin in HeLa cells following microinjection   总被引:1,自引:0,他引:1  
It is known that following iron overload newly synthesized ferritin molecules accumulate in lysosomes. However, the way in which these molecules enter the lysosomes has not been clarified. In order to assess if these molecules can be taken up by lysosomes from the cell sap, i.e., by way of autophagy, ferritin was introduced into HeLa cells through microinjection with a glass capillary. The fate of the ferritin was studied after varying intervals with the electron microscope. Shortly after microinjection ferritin molecules could be observed in the cell sap. After both 1 and 2 h, they were found in clusters and still mainly in the cell sap. After 4 h, ferritin molecules were present not only in the cell sap and in autophagic vacuoles but also in occasional secondary lysosomes. After 12 h, they were seen mainly in lysosomes, undergoing degradation. In no instance were ferritin molecules translocated into other organelles such as mitochondria, Golgi apparatus, or endoplasmic reticulum. The present study demonstrates that ferritin can be introduced into cells by glass capillary microinjection without cell damage. From its initial location in the cell sap ferritin is taken up into the lysosomal vacuome. Autophagy is considered to be the principal mechanism for the transfer of the ferritin molecules into lysosomes.  相似文献   

5.
We report a new design of a fully automated, high-efficiency parallel nonsplit nanoflow capillary HPLC system, coupled on-line with linear ion trap (LTQ) and high performance nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoESI LTQ-FTICR MS). The system, intended for high-throughput proteome analysis of complex protein mixtures, notably serum and plasma, consists of two reversed-phase trap columns for large volume sample injection with high speed sample loading and desalting and two reversed-phase analytical capillary columns. Through a nanoscale two-position, 10-port switching valve, the whole system is terminated by a 10 microm i.d. of nanoemitter mounted on the nanoelectrospray source in front of the sampling cone of the LTQ-FTICR MS. Gradient elution to both nanoflow-rate capillary columns is simultaneously delivered by a single HPLC system via two independent binary gradient pump systems. The parallel capillary column approach eliminates the time delays for column regeneration/equilibration since one capillary column is used for separating the sample mixtures and delivering the separated fractions to the MS, while the other capillary column is being regenerated and equilibrated. The reproducibility of retention time and peak intensity of the present automated parallel nanoflow-rate capillary HPLC system is comparable to that obtained using a single column configuration. Replicate injections of tryptic digests indicated that this system provided good reproducibility of retention time and peak area on both columns with average CV values of less than 1.08% and 7.04%, respectively. Throughput was increased to 100% for 2-h LC-MS analysis compared to the single capillary column LC-MS pipeline. Application of this system is demonstrated in a plasma proteomic study. A total of 312 868 MSMS events were acquired and 1564 proteins identified with high confidence (Protein Prophet > or = 0.9, and peptides matched > or = 2). Comparison of a series of plasma fractions run using the single-column LC-MS versus the parallel-column LC-MS demonstrated that parallel-column LC-MS system significantly reduced the sample carryover, improved MS data quality and increased the number of MS/MS sequence scan events.  相似文献   

6.
The availability of an excellent separation method for fatty acid methyl esters, including separation of cis and trans isomers and of isomers that differ only in the position of double bonds, has become more and more important. The present glass capillary chromatography system combines high separation power with high precision and easy handling. Moreover, the system is completely automated and therefore provides a time saving method. As compared to a conventional packed column, the glass capillary column provides about one hundred fold more theoretical plates (227,000), as well as narrower peaks, thus giving rise to less error when integrating with electronic integrators. The reproducibility for relative retention time is better with the capillary column (0.26%) and reproducibility of the weight percent values is at least similar to that of the packed column (1.53%). When handling only small sample amounts the capillary provides better values because of its low capacity. This powerful system should open up new possibilities in the field of fatty acid investigation.  相似文献   

7.
Nuclear transfer as originally developed for use in amphibians involved microinjecting a nucleus directly into the cytoplasm of the oocyte. A major mammalian modification has been to use cell fusion to introduce the nucleus. Here we report using a microinjection method to introduce small and medium sized fibroblast cells into mature oocytes. Small cells were more likely to result in nuclear formation (30%) than larger cells (15%; P = 0.013). Small, confluent and serum starved cells resulted in nuclear formation more often (P < 0.048) than did cycling cells. The rate of nuclear formation was not dependent upon the media, (NCSU-23 or TL-Hepes without calcium) nor upon the duration of exposure to the media (1 h to 4 h) after microinjection but before activation. While such treatments did not have an effect on nuclear formation, treatment of parthenogenetically activated oocytes with calcium-free TL-Hepes reduced the percentage of blastocysts (P = 0.068. 11.2% vs. 18.3%) and increased the percentage of morula stage embryos (P = 0.007; 27.6% vs. 15.7%) as compared with culture in NCSU. Finally, small confluent cells were used for nuclear transfer and resulted in two presumptive blastocyst stage embryos [2/128 injected or 2/38 (5.3%) successful injections]. These results show that presumptive blastocyst stage embryos can result from microinjection of fibroblast cells to enucleated oocytes and thus may provide a method to create transgenic knockout animals.  相似文献   

8.
M Zafarullah  P E Olsson  L Gedamu 《Gene》1989,83(1):85-93
Endogenous levels of metallothionein (MT) mRNA were detected by RNA probes in several somatic and germ-line tissues of rainbow trout, such as eggs, ovaries and immature testis. These levels may be related to metal-ion homeostasis in the observed tissues. The induction kinetics of trout MT isoform B (MT-B) mRNA were studied after single intraperitoneal injections of CdCl2, CuCl2 and ZnCl2. MT-B mRNA was induced within 12 h in liver, kidney, spleen and gills. However, over the 48-h experimental period, the kinetics of MT-B mRNA accumulation differed in response to the three metal salts, possibly due to differential handling of the salts by these tissues. Multiple metal-salt injections induced high levels of MT-B mRNA in the four tissues studied. In the rainbow trout hepatoma cell line, ZnCl2 was a better inducer of the MT-B gene, as compared to CdCl2 and CuCl2. The expression of the exogenous trout MT-B promoter in Chinook salmon embryonic cell line indicates the presence of MT regulatory factors. In contrast, the endogenous MT genes in these cells are quiescent, possibly due to the methylation of their promoter region.  相似文献   

9.
10.
Sample introduction of an imaged capillary isoelectric focusing (cIEF) instrument is fully automated by using commercially available high-performance liquid chromatography (HPLC) injection valves and autosamplers. Sample carryover can be controlled to under 1% when the valve and separation column are washed for 1 min between sample runs. The standard deviation of peak areas for 20 injections is 3.5%, which includes deviations created by the absorption imaging detector and the isoelectric focusing process inside the 75 μm I.D. column. Sample throughput is up to 10 samples per hour. The instrument has been applied to fast analysis of many proteins including monoclonal antibodies.  相似文献   

11.
At the Center for High-Throughput Minimally Invasive Radiation Biodosimetry, we have developed a rapid automated biodosimetry tool (RABiT); this is a completely automated, ultra-high-throughput robotically based biodosimetry workstation designed for use following a large-scale radiological event, to perform radiation biodosimetry measurements based on a fingerstick blood sample. High throughput is achieved through purpose built robotics, sample handling in filter-bottomed multi-well plates and innovations in high-speed imaging and analysis. Currently, we are adapting the RABiT technologies for use in laboratory settings, for applications in epidemiological and clinical studies. Our overall goal is to extend the RABiT system to directly measure the kinetics of DNA repair proteins. The design of the kinetic/time-dependent studies is based on repeated, automated sampling of lymphocytes from a central reservoir of cells housed in the RABiT incubator as a function of time after the irradiation challenge. In the present study, we have characterized the DNA repair kinetics of the following repair proteins: γ-H2AX, 53-BP1, ATM kinase, MDC1 at multiple times (0.5, 2, 4, 7 and 24 h) after irradiation with 4 Gy γ rays. In order to provide a consistent dose exposure at time zero, we have developed an automated capillary irradiator to introduce DNA DSBs into fingerstick-size blood samples within the RABiT. To demonstrate the scalability of the laboratory-based RABiT system, we have initiated a population study using γ-H2AX as a biomarker.  相似文献   

12.
Oligosaccharides attached to Asn297 in each of the CH2 domains of monoclonal antibodies play an important role in antibody effector functions by modulating the affinity of interaction with Fc receptors displayed on cells of the innate immune system. Rapid, detailed, and quantitative N-glycan analysis is required at all stages of bioprocess development to ensure the safety and efficacy of the therapeutic. The high sample numbers generated during quality by design (QbD) and process analytical technology (PAT) create a demand for high-performance, high-throughput analytical technologies for comprehensive oligosaccharide analysis. We have developed an automated 96-well plate-based sample preparation platform for high-throughput N-glycan analysis using a liquid handling robotic system. Complete process automation includes monoclonal antibody (mAb) purification directly from bioreactor media, glycan release, fluorescent labeling, purification, and subsequent ultra-performance liquid chromatography (UPLC) analysis. The entire sample preparation and commencement of analysis is achieved within a 5-h timeframe. The automated sample preparation platform can easily be interfaced with other downstream analytical technologies, including mass spectrometry (MS) and capillary electrophoresis (CE), for rapid characterization of oligosaccharides present on therapeutic antibodies.  相似文献   

13.
By a direct microinjection through pressurized glass micropipettes,we injected fluorescent Lucifer Yellow, berberine and berberine-boundDNA into protoplasts isolated from cultured Euphorbia milliicells and from tobacco mesophyll cells. The protoplasts to beinjected were held by a holding pipette with which the cytoplasmor nucleus of the protoplasts could be oriented with referenceto the tip of the injection pipette. Upon microinjection ofa berberine-bound DNA, the nucleus and intranuclear organelles,possibly including nucleolus, specifically exhibited yellowfluorescence due to berberine. This provides a direct evidencethat DNA molecules can be microinjected into the intranuclearcompartment of the protoplasts. The injected protoplasts survivedthe capillary microinjection. (Received August 6, 1984; Accepted November 12, 1984)  相似文献   

14.
A very simple and rapid GC-MS procedure for the separation and quantitation of - and -serine has been developed utilizing a conventional bonded-phase capillary column. The procedure involves initial esterification with isobutanol followed by acylation with the chiral derivatizing reagent S-(−)-N-(heptafluorobutyryl)prolyl chloride (HPC). This procedure requires neither extraction nor clean-up steps and is sensitive to 50 pg on-column. Total time of the procedure is under 3 h and derivatives are stable at room temperature for at least 5 days, making this procedure ideal for automated injections. A simple, one-day synthesis of HPC is described which yields >99.9% optical purity.  相似文献   

15.
A single-cell manipulation supporting robot (SMSR) has been developed for the high throughput and easy microinjection. Its concept is to let an experimenter concentrate his/her attention only on the microinjection by facilitating other associated works. SMSR was applied to the microinjection into rice protoplasts and mouse embryonic stem (ES) cells. The microinjection into these cells is exceptionally difficult than usual animal cells such as fibroblasts. In the case of rice protoplast, for example, non-stop microinjection into 100 cells could be done within 1h that was 17-times faster than that of the robot-less work. The success rate was 7-8% that was same level obtained by the robot-less work. The present results indicate that SMSR is a useful machine for the microinjection of specific genes and proteins in living cells to analyze their respective functions, which is an urgent and important subject in the post-genome era.  相似文献   

16.
An important aspect of automated macroarraying is the suitability of the nylon membrane selected on which samples are to be arrayed. PerForma is a positively charged nylon membrane that has been developed specificallyfor automated macroarraying. Tests usingfluorescent hybridization detection methods have shown that immobilized DNA amounts as low as 0.25 pg can be detected and that positive signals are obtainable after 21 stripping cycles. This report describes the improved colony growth, improved handling characteristics, increased hybridization detection sensitivity, and increased stripping and reprobing capability obtained using PerForma.  相似文献   

17.
《The Journal of cell biology》1983,97(5):1566-1572
To determine whether red blood cell-mediated microinjection of antibodies can be used to study nuclear protein localization and function, we microinjected antibodies that have been shown to react specifically with nucleolar acidic phosphoprotein C23 into Walker 256 cells. The intracellular distribution of microinjected anti-C23 antibodies and preimmune immunoglobulins were determined by immunofluorescence. At 3 h after microinjection, affinity-purified anti- C23 antibodies were localized in the cytoplasm and nucleolus. At 17 h after microinjection, the affinity-purified antibody was localized to those nucleolar structures previously shown to contain protein C23. Furthermore, the antibody remained localized in the nucleolus for at least 36 h after microinjection. In contrast to the results obtained with specific antibodies, preimmune immunoglobulins remained in the cytoplasm 36 h after microinjection. These results indicate that red blood cell-mediated microinjection of antibodies can be used to study nucleolar and nuclear antigens.  相似文献   

18.

Background

Methods of manual cell localization and outlining are so onerous that automated tracking methods would seem mandatory for handling huge image sequences, nevertheless manual tracking is, astonishingly, still widely practiced in areas such as cell biology which are outside the influence of most image processing research. The goal of our research is to address this gap by developing automated methods of cell tracking, localization, and segmentation. Since even an optimal frame-to-frame association method cannot compensate and recover from poor detection, it is clear that the quality of cell tracking depends on the quality of cell detection within each frame.

Methods

Cell detection performs poorly where the background is not uniform and includes temporal illumination variations, spatial non-uniformities, and stationary objects such as well boundaries (which confine the cells under study). To improve cell detection, the signal to noise ratio of the input image can be increased via accurate background estimation. In this paper we investigate background estimation, for the purpose of cell detection. We propose a cell model and a method for background estimation, driven by the proposed cell model, such that well structure can be identified, and explicitly rejected, when estimating the background.

Results

The resulting background-removed images have fewer artifacts and allow cells to be localized and detected more reliably. The experimental results generated by applying the proposed method to different Hematopoietic Stem Cell (HSC) image sequences are quite promising.

Conclusion

The understanding of cell behavior relies on precise information about the temporal dynamics and spatial distribution of cells. Such information may play a key role in disease research and regenerative medicine, so automated methods for observation and measurement of cells from microscopic images are in high demand. The proposed method in this paper is capable of localizing single cells in microwells and can be adapted for the other cell types that may not have circular shape. This method can be potentially used for single cell analysis to study the temporal dynamics of cells.  相似文献   

19.
The ELISpot assay is used for the detection of T cell responses in clinical trials and vaccine evaluations. Standardization and reproducibility are necessary to compare the results worldwide, inter- and intra-assay variability being critical factors. To assure operator safety as well as high-quality experiment performance, the ELISpot assay was implemented on an automated liquid handling platform, a Tecan Freedom EVO. After validation of the liquid handling, automated loading of plates with cells and reagents was investigated. With step by step implementation of the manual procedure and liquid dispensing optimization on the robot platform, a fully automated ELISpot assay was accomplished with plates remaining in the system from the plate blocking step to spot development. The mean delta difference amounted to a maximum of 6%, and the mean dispersion was smaller than in the manual assay. Taken together, we achieved with this system not only a lower personnel attendance but also higher throughput and a more precise and parallelized analysis. This platform has the potential to guarantee validated, safe, fast, reproducible and cost-efficient immunological and toxicological assays in the future.  相似文献   

20.
Synthetic mRNAs can be injected to achieve transient gene expression even for 'non-model' organisms in which genetic approaches are not feasible. Here, we have used this technique to express proteins that can serve as lineage tracers or reporters of cellular events in embryos of the glossiphoniid leech Helobdella robusta (phylum Annelida). As representatives of the proposed super-phylum Lophotrochozoa, glossiphoniid leeches are of interest for developmental and evolutionary comparisons. Their embryos are suitable for microinjection, but no genetic approaches are currently available. We have injected segmentation stem cells (teloblasts) with mRNAs encoding nuclear localized green fluorescent protein (nGFP) and its spectral variants, and have used tandem injections of nGFP mRNA followed by antisense morpholino oligomer (AS MO), to label single blast cell clones. These techniques permit high resolution cell lineage tracing in living embryos. We have applied them to the primary neurogenic (N) lineage, in which alternate segmental founder cells (nf and ns blast cells) contribute distinct sets of progeny to the segmental ganglia. The nf and ns blast cell clones exhibit strikingly different cell division patterns: the increase in cell number within the nf clone is roughly linear, while that in the ns clone is almost exponential. To analyze spindle dynamics in the asymmetric divisions of individual blast cells, we have injected teloblasts with mRNA encoding a tau::GFP fusion protein. Our results show that the asymmetric divisions of n blast cells result from a posterior shift of both the spindle within the cell and the midbody within the mitotic spindle, with differential regulation of these processes between nf and ns.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号