共查询到20条相似文献,搜索用时 15 毫秒
1.
Humphries D Ruterbories K Chan C Narayanan R 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,810(2):229-234
A sensitive and selective LC-MS-MS method for the isolation and quantification of alpha-methyltyrosine (AMT) from human plasma is described. The method employs a simple protein precipitation using zinc sulfate and sodium hydroxide. This precipitation procedure produced samples with high aqueous content that could be directly injected into a LC-MS-MS system without compromising reverse-phase chromatographic performance. Chromatographic separation was performed on a MetaChem MonoChrom C(18) column (2.0 mm x 50 mm; 5 microm) at a flow rate of 1 mL/min. Compounds were eluted using a gradient mixture of water-acetic acid (100:0.1, v/v) and acetonitrile-acetic acid (100:0.1, v/v). The structural analog alpha-hydroxymethyltyrosine was used as the internal standard. Mass spectrometric detection was carried out with a triple quadrupole mass spectrometer. The method was validated and used to determine human plasma AMT concentrations, and has been implemented to derive pharmacokinetic parameters. 相似文献
2.
Bajad S Singla AK Bedi KL 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,776(2):245-249
Piperine, a major alkaloid of Piper longum and Piper nigrum has been reported to have several pharmacological/toxicological effects. Though a number of methods for analysis of this omnipresent food component in pepper fruits are available, its analysis in body fluids has been largely neglected. A high-performance liquid chromatography method for the analysis of piperine in rat plasma is presented in this communication. Analysis was performed using a Symmetry C(18) column (250x4.6 mm) by isocratic elution with 25 mM KH(2)PO(4) (pH 4.5)-acetonitrile (35:65) and UV detection at 340 nm. The calibration plot was linear over the range studied (2-2000 ng) with correlation coefficient of 0.9984. Limit of detection and limit of quantitation were 1 ng/ml and 3 ng/ml, respectively. Good overall recovery (85.5+/-6%) was obtained with 4 ml ethyl acetate and extraction time of 3 min. Intra- and inter-assay coefficient of variation was found to be less than 7.5%. Plasma concentration-time profile of piperine in a conscious rat implanted with jugular vein cannula was obtained using this method. The method is simple, sensitive and reproducible. 相似文献
3.
Chang YW Yao HT Hsieh SH Lu TJ Yeh TK 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,857(1):164-169
A method for the quantification of salidroside, a major biologically active compound in Rhodiola, in rat plasma by on-line SPE LC/MS/MS in negative electrospray mode was developed and validated. A column-switching instrument and two HPLC pumping systems were employed, and salicin was used as the internal standard. A Waters Oasis HLB extraction column and an Agilent TC-C(18) analytical column in a column-switching set-up with gradient elution were utilized. The MS/MS ion transitions monitored were m/z 299.0/119.0 and 285.1/122.9 for salidroside and salicin, respectively. The standard curves were linear within a range of 50-5000 ng/mL using weighted linear regression analysis (1/x). The intra- and inter-day coefficients of variance ranged from 1% to 9%. The recovery was above 90%. The freeze/thaw and long-term stability were validated. This method was subsequently applied to a pharmacokinetic study of salidroside in rats. 相似文献
4.
Verhaeghe T Diels L de Vries R De Meulder M de Jong J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,789(2):337-346
Galantamine is an acetylcholinesterase inhibitor, recently approved for the treatment of mild-to-moderate Alzheimer's disease. To allow a higher throughput of samples, a new bioanalytical method for the determination of galantamine in human plasma was developed and validated. A stable isotope labelled internal standard was used. Sample preparation consisted of a simple one-step liquid-liquid extraction with toluene. The extracts were analysed with positive ion TurboIonspray tandem mass spectrometry (LC-MS-MS). The method was validated in the 1-500-ng/ml range. The accuracy, precision, selectivity, lower limit of quantification, upper limit of quantification, linearity and extraction recovery were evaluated, as well as the stability of the compound in plasma, blood, methanol and 2% BSA solutions under different conditions. The method proved very rugged during the analysis of large numbers of samples from clinical trials. 相似文献
5.
Celli N Mariani B Dragani LK Murzilli S Rossi C Rotilio D 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,810(1):129-136
Caffeic acid phenethyl ester (CAPE) is one of the most bioactive compounds of propolis, a resinous substance collected and elaborated by honeybees. A new liquid chromatography-electrospray ionisation tandem mass spectrometric method was developed and validated for its determination in rat plasma and urine, using taxifolin as internal standard. After sample preparation by liquid/liquid extraction with ethyl acetate, chromatographic separations were carried out with an ODS-RP column using a binary mobile phase gradient of acetonitrile in water. Detection was performed using a turboionspray source operated in negative ion mode and by multiple reaction monitoring. The method was validated, showing good selectivity, sensitivity (LOD = 1 ng/ml), linearity (5-1000 ng/ml; r > or = 0.9968), intra- and inter-batch precision and accuracy (< or =14.5%), and recoveries (94-106%) in both plasma and urine. Stability assays have shown that CAPE is rapidly hydrolysed by plasmatic esterases, which are however inhibited by sodium fluoride. The method was applied to the determination of CAPE levels in rat plasma and urine after oral administration, showing that CAPE is rapidly absorbed and excreted in urine both as unmodified molecule and as glucuronide conjugate. 相似文献
6.
Hongjun Xia Xiaodan WangLi Li Shengjia WangChangchuan Guo Yao LiuLushan Yu Huidi JiangSu Zeng 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(28):2701-2706
A highly sensitive HPLC–ESI-MS method has been developed and validated for the quantification of ginkgolic acid (15:1) in a small quantity of rat plasma (50 μL) using its homologous compound ginkgolic acid (17:1) as an internal standard. GA (15:1) and GA (17:1) were extracted from biological matrix by direct protein precipitation with 5-fold volume of methanol and separated on an Elite hypersil BDS C18 column (2.1 × 100 mm, 3 μm), eluted with acetonitrile:water (92:8, v/v, containing 0.3% glacial acetic acid). Linear range was 8–1000 ng/mL with the square regression coefficient (r2) of 0.996. The lowest concentration (8 ng/mL) in the calibration curve was estimated as LLOQ with both deviation of accuracy and RSD of precision <20% (n = 6). The intra- and inter-day precision ranged from 3.6% to 9.9%, and the intra- and inter-day accuracy was between 89.9% and 101.3%. This method was successfully applied to study pharmacokinetics of GA (15:1) in rats after oral administration at a dose of 10 mg/kg. GA (15:1) pharmacokinetic parameters Cmax, Tmax, t1/2, AUC0–12h are 1552.9 ± 241.0 ng/mL, 0.9 ± 0.7 h, 5.5 ± 2.6 h, 3356.0 ± 795.3 ng h/mL, respectively. 相似文献
7.
Li L Chen X Dai X Chen H Zhong D 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,856(1-2):171-177
A rapid and selective liquid chromatographic/tandem mass spectrometric method for determination of fosfomycin was developed and validated. Following protein-precipitation, the analyte and internal standard (fudosteine) were separated from human plasma using an isocratic mobile phase on an Ultimate XB-CN column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 137-->79 and m/z 178-->91 was performed to quantify fosfomycin and fudosteine, respectively. The method was linear in the concentration range of 0.10-12.0 microg/mL using 50 microL of plasma. The lower limit of quantification was 0.10 microg/mL. The intra- and inter-day relative standard deviation over the entire concentration range was less than 10.6%. Accuracy determined at three concentrations (0.25, 1.00 and 8.00 microg/mL for fosfomycin) ranged from -1.0% to -4.2% in terms of relative error. Each plasma sample was chromatographed within 5.0 min. The method was successfully used in a bioequivalence study of fosfomycin in human plasma after an oral administration of capsules containing 1.0 g fosfomycin (approximately 1.3g calcium fosfomycin). 相似文献
8.
Lin ZJ Abbas R Rusch LM Shum L 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,788(1):159-166
Cromolyn sodium is a safe compound with potent anti-allergic properties when used locally or topically. Clinical data from systemic exposure is not available because of the poor GI absorption when given orally. In order to evaluate a new approach to enhance the absorption and bioavailability of cromolyn sodium, a sensitive assay was needed to support an oral-dose study in humans. This paper describes a liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method for the analysis of cromolyn sodium in human plasma. The method consists of a two-step extraction with subsequent analysis using a high-performance liquid chromatography electrospray tandem mass spectrometer system. The compounds were eluted isocratically on a C(18) column followed by a backflush. The total run time is 6 min. The standard curve of cromolyn sodium was over the range of 0.313 to 750 ng/mL with a lower limit of quantitation (LLOQ) of 0.313 ng/mL when 0.5 mL of plasma was used for analysis. The percent coefficient of variation (C.V.) for accuracy and precision (inter-assay and intra-assay) was less than 15% over the validated concentration range and the coefficients of determination, r(2), were >0.991577. The method is simple, sensitive, and selective, and has been successfully utilized for oral cromolyn sodium clinical studies. 相似文献
9.
Fuentes-Noriega I Ruiz-Ramírez L Tovar Tovar A Rico-Morales H Gracia-Mora I 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,766(1):115-121
In order to measure changes in physiological CO concentrations in blood with good accuracy, a method was developed using gas chromatography with flame ionisation detection (250 degrees C). A nickel catalyst system was fitted to convert CO to methane at 375 degrees C after separation with a molecular sieve column at 35 degrees C. Helium was used as carrier at 30 ml/min. Porcine or human blood (400 microl) was sampled in gastight tubes and treated with sulfuric acid and saponin (800 microl). Accuracy was 1.4% and 1.5% (RSD), respectively. Precision was 2.8% (porcine blood). Limit of detection was 0.01 nmol/ml gas and limit of quantification 12 nmol/ml blood. Calibration was made in the interval 12-514 nmol/ml blood (corresponding to 0.1-6% COHb). Samples were stable for at least a month at +4 degrees C. This paper describes a method with high sensitivity and good accuracy, suitable for analysis of low CO concentrations. 相似文献
10.
Li L Pabbisetty D Carvalho P Avery MA Williamson JS Avery BA 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,867(1):131-137
A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to quantify artemisinin in rat serum. The lower limit of quantification (LLOQ) was 4 ng/mL. The calibration curve was linear from 4 ng/mL to 10,000 ng/mL (R=0.998). The assay was based on the selected reaction monitoring (SRM) transitions at m/z 305.4-151.10 for artemisinin and m/z 335.2-163.10 for arteether (internal standard). The artemisinin and internal standard can be separated from endogenous interferences in rat serum. Inter- and intra-day assay variation was less than 15%. The extraction recoveries ranged from 80.0 to 107.3% at the three concentrations (5000, 2000, and 200 ng/mL). This method was successfully applied to pharmacokinetic studies of artemisinin after intravenous and oral administration to rats. 相似文献
11.
Reyes L Fuentes-Noriega I Ruiz-Ramìrez L Macías L 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,791(1-2):111-116
A sensitive and specific liquid chromatographic method using solid-phase extraction with Sep-pak cartridges has been developed for the determination of Casiopeina IIgly and validated over the linear range 2.5-50 microg/ml in rat plasma. The analysis was performed on a Symetry C(18) (5 microm) column with a Phenomenex C(18) precolumn. The mobile phase was methanol-water (58:42, v/v). The column effluent was monitored at 273 nm. The results showed that the assay is sensitive at 2.5 microg/ml. Maximum intra-day coefficient of variation was 11.47%. The recovery based upon addition of internal standard to rat plasma was 80.98%. The method was used to perform preclinical pharmacokinetic studies in rat plasma and was found to be satisfactory. 相似文献
12.
Bian Z Tian Y Zhang Z Xu F Li J Cao X 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,850(1-2):68-73
A selective and sensitive high performance liquid chromatography-electrospray ionisation-mass spectrometry method has been developed for the determination of balofloxacin (BLFX) in human plasma. The sample preparation was a liquid-liquid extraction, and chromatographic separation was achieved with an Agilent ZORBAX 300SB C18 2.1 mm x 150 mm column using a mobile phase comprised of methanol-water (10 mM CH(3)COONH(4), pH 3.0)=40:60 (v/v). Standard curves were linear (r=0.9992) over the concentration range of 0.03-3 microg/ml and had good accuracy and precision. The within- and between-batch precisions were within 10% relative standard deviation (R.S.D.). The limit of detection (LOD) was 0.02 microg/ml. The validated HPLC-electrospray ionization (ESI)-MS method has been used successfully to study balofloxacin pharmacokinetics in healthy volunteers. 相似文献
13.
Li HL Peng XJ He JC Feng EF Xu GL Rao GX 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(19):1653-1658
A new LC-ESI-MS/MS assay method has been developed and validated for the quantification of swertiamarin, a representative bioactive substance of Swertia plants, in rat plasma using gentiopicroside, an analog of swertiamarin on chemical structure and chromatographic action, as the internal standard (IS). The swertiamarin and IS were extracted from rat plasma using solid-phase extraction (SPE) as the sample clean-up procedure, and they were chromatographed on a narrow internal diameter column (Agilent ZORBAX ECLIPSE XDB-C(18) 100 mm × 2.1 mm, 1.8 μm) with the mobile phase consisting of methanol and water containing 0.1% acetic acid (25:75, v/v) at a flow rate of 0.2 mL/min. The detection was performed on an Agilent G6410B tandem mass spectrometer by negative ion electrospray ionisation in multiple-reaction monitoring mode while monitoring the transitions of m/z 433 [M+CH(3)COO](-)→179 and m/z 415 [M+CH(3)COO](-)→179 for swertiamarin and IS, respectively. The lower limit of quantification (LLOQ) was 5 ng/mL within a linear range of 5-1000 ng/mL (n=7, r(2)≥0.994), and the limit of detection (LOD) was demonstrated as 1.25 ng/mL (S/N≥3). The method also afforded satisfactory results in terms of sensitivity, specificity, precision (intra- and inter-day), accuracy, recovery, freeze/thaw, long-time stability and dilution integrity. This method was successfully applied to determination of the pharmacokinetic properties of swertiamarin in rats after oral administration at a dose of 20 mg/kg. The following pharmacokinetic parameters were obtained (mean): maximum plasma concentration, 1920.1 ng/mL; time to reach maximum plasma concentration, 0.945 h; elimination half-time, 1.10h; apparent total clearance, 5.638 L/h/kg; and apparent volume of distribution, 9.637 L/kg. 相似文献
14.
Zhang L Tian Y Zhang Z Chen Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,854(1-2):91-98
A selective and sensitive high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (ESI-MS/MS) method for simultaneous determination of metformin and rosiglitazone in human plasma using phenformin as internal standard (IS) has been first developed and validated. Plasma samples were precipitated by acetonitrile and the analytes were separated on a prepacked Phenomenex Luna 5u CN 100A (150 mm x 2.0 mm I.D.) column using a mobile phase comprised of methanol:30 mM ammonium acetate pH 5.0 (80:20, v/v) delivered at 0.2 ml/min. Detection was performed on a Finnigan TSQ triple-quadrupole tandem mass spectrometer in positive ion selected reaction monitoring (SRM) mode using electrospray ionization. The ion transitions monitored were m/z 130.27-->71.11 for metformin, m/z 358.14-->135.07 for rosiglitazone and m/z 206.20-->105.19 for the IS. The standard curves were linear (r(2)>0.99) over the concentration range of 5-3000 ng/ml for metformin and 1.5-500 ng/ml for rosiglitazone with acceptable accuracy and precision, respectively. The within- and between-batch precisions were less than 15% of the relative standard deviation. The limit of detection (LOD) of both metformin and rosiglitazone was 1 ng/ml. The method described is precise and sensitive and has been successfully applied to the study of pharmacokinetics of compound metformin and rosiglitazone capsules in 12 healthy Chinese volunteers. 相似文献
15.
Satonin DK McCulloch JD Kuo F Knadler MP 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,852(1-2):582-589
A sensitive bioanalytical method for the measurement of two major circulating metabolites of duloxetine [4-hydroxy duloxetine glucuronide (LY550408) and 5-hydroxy-6-methoxy duloxetine sulfate (LY581920)] in plasma is reported. This method produced acceptable precision and accuracy over the validation range of 1-1000 ng/mL. Several issues had to be addressed in order to develop an LC/MS/MS assay for these metabolites. First, 4-hydroxy duloxetine glucuronide required chromatographic resolution from the 5-, and 6-hydroxy duloxetine glucuronide isomers. Second, the glucuronide conjugate is readily ionized under positive ESI conditions, while the sulfate conjugate required negative ESI conditions to obtain adequate sensitivity. Finally, the chromatographic conditions needed to separate the glucuronide isomers were not suitable for the analysis of the sulfate conjugate. The present method addressed these challenges, and was successfully applied to multiple human pharmacokinetic studies in which subjects received oral doses of duloxetine hydrochloride. 相似文献
16.
Weng Naidong Jean W. Lee James D. Hulse 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1994,654(2)
An isocratic HPLC method was developed and validated for the quantitation of methocarbamol in human plasma. Methocarbamol and internal standard in 200 μl of human plasma were extracted with ethyl acetate, evaporated to dryness and reconstituted in water. Separation was achieved on a reversed-phase C18 column with a mobile phase of methanol—0.1 M potassium phosphate monobasic—water (35:10:55, v/v/v). The detection was by ultraviolet at 272 nm. Linearity was established at 1–100 μg/ml (r > 0.999). The limit of quantitation was designed as 1 μg/ml to suit pharmacokinetic studies. Inter-day precision and accuracy of the calibration standards were 1.0 to 3.6% coefficients of variance (C.V.) and −2.0 to +1.6% relative error (R.E.). Quality controls of 3, 20 and 70 μg/ml showed inter-day precision and accuracy of 2.5 to 3.6% C.V. and −0.9 to −0.4% R.E. Recovery of methocarbamol was 91.4–100.3% in five different lots of plasma. The method was shown to be applicable on different brands of C18 columns. 相似文献
17.
Ptácek P Klíma J Macek J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,858(1-2):263-268
A sensitive and reliable method was developed to quantitate phenylephrine in human plasma using liquid chromatography-electrospray tandem mass spectrometry. The assay was based on solid-phase extraction with C18 cartridges and hydrophilic interaction chromatography performed on a pentafluorophenylpropylsilica column (50 mm x 4 mm, 3 microm particles), the mobile phase consisted of methanol-10 mM ammonium acetate (90:10, v/v). Quantification was through positive-ion mode and selected reaction monitoring at m/z 168.1-->135.0 for phenylephrine and m/z 182.1-->135.0 for internal standard etilefrin, respectively. The lower limit of quantitation was 51 pg/ml using 0.25 ml of plasma and linearity was observed from 51 to 5500 pg/ml. Within-day and between-day precision expressed by relative standard deviation was less than 12% and inaccuracy did not exceed 8% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study. 相似文献
18.
Wang R Wang G Hao H Xie H Zhang J Wu F 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,831(1-2):36-41
Atractylenolide III is a major active component in Atractylodes macrocephala. This paper describes a simple, rapid, specific and sensitive method for the quantification of atractylenolide III in rat plasma using a liquid-liquid extraction procedure followed by liquid chromatography mass spectrometric (LC-MS) analysis. A Kromasil 3.5 microm C(18) column (150 mm x 2.00 mm) was used as the analytical column. Linear detection responses were obtained for atractylenolide III concentration ranging from 5 to 500 ng L(-1). The precision and accuracy data, based on intra-day and inter-day variations over 5 days were within 10.29%. The lower limit of quantitation for atractylenolide III was 5 ng mL(-1), using 0.1 mL plasma for extraction and its recoveries were greater than 85% at the low, medium and high concentrations. The method has been successfully applied to a pharmacokinetic study in rats after an oral administration of atractylenolide III with a dose of 20.0 mg kg(-1). With the lower limits of quantification at 5 ng mL(-1) for atractylenolide III, this method was proved to be sensitive enough for the pharmacokinetics study of atractylenolide III. 相似文献
19.
Vijaya Bharathi D Jagadeesh B Hotha KK Patil U Bhushan I 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(26):2827-2833
A highly sensitive, selective and evaporation free SPE extraction, ESI-LC-MS/MS method has been developed for estimation of misoprostol free acid in human plasma using misoprostol acid-d(5) as an internal standard (IS). The analyte was separated using isocratic mobile phase on reverse phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M-H] anions, m/z 367-249 for misoprostol acid and m/z 372-249 for the IS. The total run time was 5.0 min and the elution of misoprostol acid and misoprostol acid-d(5) (IS) occurred at 3.6 min. The developed method was validated in human plasma with a lower limit of quantification of 2.5 pg/mL. A linear response function was established for the range of concentrations 2.5-1200 pg/mL (r>0.998) for misoprostol acid in human plasma. The intra and inter-day precision values for misoprostol acid met the acceptance as per FDA guidelines. Misoprostol acid was stable in the battery of stability studies viz., bench-top, auto-sampler and freeze/thaw cycles. The developed assay method was applied to an oral pharmacokinetic study in humans. 相似文献
20.
Naruto Tomiyama Hiromi Tsuji Momiko Watanabe Makio Takeda Takanori Harada Hiroko Kobayashi 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,748(2):2184
A sensitive and reliable high-performance liquid chromatographic (HPLC) method, using a solid-phase extraction (SPE), was established and validated for determination of p,p′-DDT [1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane] and its metabolite p,p′-DDE [1,1-(2,2-dichloroethanylidene)-bis(4-chlorobenzene)] in rat plasma, liver and brain. After being diluted with water, plasma, liver and brain samples were applied to a solid-phase extraction C18 cartridge. The extraction containing p,p′-DDT and p,p′-DDE from the cartridge were cleaned-up using a Florisil Sep-Pak cartridge. The samples were analyzed by HPLC using UV detection at 238 nm. The limit of detection for p,p′-DDT and p,p′-DDE was 0.1 mg kg−1 liver or brain and 0.1 mg l−1 plasma. For six replicate samples at 40, 4 and 0.2 mg kg−1, intra-day precision values were within 4.9% for plasma, 6.4% for liver, and 9.7% for brain. Inter-day precision values at 4 mg kg−1 were within 8.2% for plasma and tissues. The method performances were shown to be selective for p,p′-DDT and p,p′-DDE, and linear over the range 0.04–12 mg kg−1 (mg l−1 for plasma). The absolute recoveries of p,p′-DDT and p,p′-DDE in rat plasma and tissues were over 92%. The method was proved to be applicable to the pharmacokinetic study of DDT in rats after a single oral administration. 相似文献