共查询到20条相似文献,搜索用时 9 毫秒
1.
The investigation of the stabilities of o-phthalaldehyde/2-mercaptoethanol derivatives of amino acids using a precolumn reaction technique and a high-pressure liquid chromatographic procedure is reported. The amino acid derivatives are shown to be stable on the high-pressure liquid chromatography column. Optimal conditions for the development of these derivatives for their separation using this technique are recommended. 相似文献
2.
3.
Sayuri Matsumura Hiroyuki Kataoka Masami Makita 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,681(2):375
A simple and rapid method for the determination of serum amino acids by gas chromatography (GC) has been developed. Following deproteinization of serum with perchloric acid, free amino acids in the supernatant were converted into their N(O,S)-isobutoxycarbonyl methyl ester derivatives and measured by GC with flame ionization detection using a DB-17 capillary column. All the derivatives of the 22 protein amino acids were completely resolved as single peaks within 9 min by GC. The calibration curves were linear in the range 0.2–50 μg of each amino acid, and the correlation coefficients were above 0.998. By using this method, serum amino acids could be directly analysed without prior clean-up procedure such as ion-exchange column chromatography except for deproteinization of the samples, and without any interference from coexisting substances. Overall recoveries of amino acids added to serum samples were 88–108%. Analytical results for serum amino acids from normal subjects are presented. 相似文献
4.
Besifloxacin hydrochloride is a novel chiral broad-spectrum fluoroquinolone developed for the treatment of bacterial conjunctivitis. R-besifloxacin hydrochloride is used in clinics as a consequence of its higher antibacterial activity. To establish an enantiomeric impurity determination method, some chiral stationary phases (CSPs) were screened. Besifloxacin enantiomers can be separated to a certain extent on Chiral CD-Ph (Shiseido Co., Ltd., Japan), Chiral AGP, and Crownpak CR (+) (Daicel Chemical IND., Ltd., Japan). However, the selectivity and sensitivity were both unsatisfactory on these three CSPs. Therefore, Chiral AGP, Chiral CD-Ph, and Crownpak CR (+) were not used in the enantiomeric impurity determination of besifloxacin hydrochloride. The separation of enantiomers of besifloxacin was further performed using a precolumn derivatization chiral high-performance liquid chromatography method. 2,3,4,6-Tetra-O-acetyl-beta-D-glucopyranosyl isothiocyanate was used as the derivatization reagent. Besifloxacin enantiomer derivates were well separated on a C(18) column (250 × 4.6 mm, 5 μm) with a mobile phase that consisted of methanol-KH(2)PO(4) buffer solution (20 mM; pH 3.0) (50:50, v/v). Selectivity, sensitivity, linearity, accuracy, precision, stability, and robustness of this method were all satisfied with the method validation requirement. The method was suitable for the quality control of enantiomeric impurity in besifloxacin hydrochloride. 相似文献
5.
两种柱前衍生反相高效液相色谱法测定血液和尿液中游离氨基酸 总被引:1,自引:0,他引:1
建立以PITC法和AQC法为柱前衍生试剂测定血液和尿液中游离氨基酸含量的测定方法。采用Waters-e2695操作系统,色谱柱为Shim-vp,ODS(250mm×4.6mm,5μm)(日本,岛津公司),以甲醇/乙腈/水和醋酸钠溶液(pH 6.5)为流动相,梯度洗脱。分别采用紫外和荧光检测器对血液和尿液中游离氨基酸进行含量测定。结果显示,两种衍生化方法灵敏度好、分离度高,具有良好的线性范围(r>0.990 0),准确度高(平均回收率为75.1%~127.0%),进样精密度好(RSD为0.12%~3.42%)。PITC法在尿液中游离氨基酸含量测定中显示了良好的测试准确性;而AQC法测定尿液中组氨酸、苏氨酸、脯氨酸超出线性范围,需要对尿样的前处理进行深入研究。 相似文献
6.
A sensitive and selective HPLC method for the determination of the disaccharides of chondroitin sulfate in horse and dog plasma was validated. Chondroitin sulfate is degraded by chondroitinase ABC to three primary unsaturated disaccharides, (1) 2-acetamido-2-deoxy-3-O-(beta-D-gluco-4-enepyranosyluronic acid)-D-galactose, (2) 2-acetamido-2-deoxy-3-O-(beta-D-gluco-4-enepyranosyluronic acid)-4-O-sulfo-D-galactose, and (3) 2-acetamido-2-deoxy-3-O-(beta-D-gluco-4-enepyranosyluronic acid)-6-O-sulfo-D-galactose, when treated with chondroitinase. Plasma samples (0.5 ml) were treated with 50 mU of chondroitinase ABC in 50 microl of 1 mM sodium phosphate buffer (pH 7.0) at 37 degrees C for 6 h. The samples were extracted with 25% trifluoroacetic acid in ethanol. The resultant samples were derivatized with 1% dansylhydrazine in ethanol at 40 degrees C for 3 h. The chromatographic conditions consisted of fluorescence detection (excitation at 350 nm and emission at 530 nm), mu-Bondapack NH(2) (300 x 3.9 mm), and mobile phase of acetonitrile:100 mM acetate buffer, pH 5.6 (76:24), pumped at 1.0 ml/min. The standard curves for each chondroitin disaccharide showed linearity over the selected concentration range (r > or = 0.99). The intraday percentage relative standard deviation was < or =9.5% and the interday precision was < or =6.9% or less. The relative intraday and interday error ranged from -7.3 to 6.6% for each chondroitin disaccharide in the plasma. The extraction recovery was found to be in the range of 90-96%. The validated method accurately quantitated the disaccharides of chondroitin sulfate after administration to dogs and horses. 相似文献
7.
Summary The collagen study includes the analysis of its characteristic amino acids: proline, hydroxyproline, lysine, hydroxylysine. HPLC offers an interesting device if associated with on-line radiometric detection for the determination of radiolabelled amino acids in the case of metabolism studies. To avoid pre or post-column derivatization which may be poorly quantitative in the case of the hydrolysate of unpurified samples, we developed an ion-paired reversed-phase chromatography using a C8 column (econosphere C8 5µm, length: 250 mm, ID: 4.6 mm from Alltech Ass.) and an elution carried out with an acetonitrile gradient in heptane-sulfonate solution. A direct detection at 210 nm was used. Nineteen amino acids were separated within 40 min. Lag time was 7.3 min between hydroxyproline and proline, and 6.9 min between hydroxylysine and lysine. In the case of radiolabelled amino acid, there was a linear correlation (r = 0.92) between HPLC and ion-exchange chromatography. 相似文献
8.
G. Thorsn J. Bergquist 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,745(2)
A method is presented for the chiral analysis of amino acids in biological fluids using micellar electrokinetic chromatography (MEKC) and laser-induced fluorescence (LIF). The amino acids are derivatized with the chiral reagent (+/−)-1-(9-anthryl)-2-propyl chloroformate (APOC) and separated using a mixed micellar separation system. No tedious pre-purification of samples is required. The excellent separation efficiency and good detection capabilities of the MEKC-LIF system are exemplified in the analysis of urine and cerebrospinal fluid. This is the first time MEKC has been reported for chiral analysis of amino acids in biological fluids. The amino acids
-alanine,
-glutamine, and
-aspartic acid have been observed in cerebrospinal fluid, and
-alanine and
-glutamic acid in urine. To the best of our knowledge no measurements of either
-alanine in cerebrospinal fluid or
-glutamic acid in urine have been presented in the literature before. 相似文献
9.
The structures and masses of amino acids and their more common modified forms (posttranslational and artificial) are presented
as aids to analysis of polypeptides by mass spectrometry. 相似文献
10.
A cation-sensing electrode can be used to monitor enzymatic reactions if their substrates and products differ in the ability to bind the cation. In the first method, the electrode potential vs time curve is recorded. The second, metal-stat method consists of measuring the rate at which substrate must be added to the reaction medium in order to keep the electrode potential at a constant level. These approaches have been used to assay inorganic pyrophosphatase, carboxypeptidase A, and hexokinase with the Mg2+ and Cu2+ ions as the indicators. 相似文献
11.
Summary A method of ion exchange column chromatography was developed for the determination of D- and L-amino acids in the form of diastereomeric dipeptide. First the protein containing samples were hydrolyzed with 6 molar hydrochloric acid, then the single amino acids were separated in an LKB automated amino acid analyzer with the LKB fraction collector. Following lyophilization, the single amino acids were transformed into alanyl dipeptides with tertiary-butyloxycarbonil-L-alanine-N-hydroxy-succinimide (t-BOC-L-Ala-ONSu) active ester. The alanyl dipeptides were easily separated from one another and the initial amino acids. Determination of the D- and L-amino acids in this form is relatively accurate and reproducible but takes some time (33–38 min). Accuracy of the determination is satisfactory. The coefficient of variation amounts to 3–5%. The use of the method is suggested to laboratories having an amino acid analyzer and wish to determine D-and L-amino acids in synthetic-amino acids complements, peptides or natural materials. 相似文献
12.
13.
Namera A Yashiki M Nishida M Kojima T 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,776(1):49-55
The purpose of this study was to develop a simple and accurate analytical method to determine amino acids in urine samples. The developed method involves the employment of an extract derivatization technique together with gas chromatography-mass spectrometry (GC-MS). Urine samples (300 microl) and an internal standard (10 microl) were placed in a screw tube. Ethylchloroformate (50 microl), methanol-pyridine (500 microl, 4:1, v/v) and chloroform (1 ml) were added to the tube. The organic layer (1 microl) was injected to a GC-MS system. In this proposed method, the amino acids in urine were derivatized during an extraction, and the analytes were then injected to GC-MS without an evaporation of the organic solvent extracted. Sample preparation was only required for ca. 5 min. The 15 amino acids (alanine, aspartic acid, cysteine, glutamic acid, glycine, histidine, isoleucine, leucine, lysine, methionine, phenylalanine, proline, tyrosine, tryptophan, valine) quantitatively determined in this proposed method. However, threonine, serine, asparagine, glutamine, arginine were not derivatized using any tested derivatizing reagent. The calibration curves showed linearity in the range of 1.0-300 microg/ml for each amino acid in urine. The correlation coefficients of the calibration curves of the tested amino acids were from 0.966 to 0.998. The limit of detection in urine was 0.5 microg/ml except for aspartic acid. This proposed method demonstrated substantial accuracy for detection of normal levels. This proposed method was limited for the determination of 15 amino acids in urine. However, the sample preparation was simple and rapid, and this method is suitable for a routine analysis of amino acids in urine. 相似文献
14.
Quantitative determination of aromatic amino acids and related compounds in rumen fluid by high-performance liquid chromatography 总被引:2,自引:0,他引:2
Rokibul Islam Khan M. Ruhul Amin Nazimuddin Mohammed Ryoji Onodera 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,710(1-2):17-25
A rapid method for the quantitative determination of tyrosine (Tyr), phenylalanine (Phe), p-hydroxybenzoic acid (HBA), p-hydroxyphenylacetic acid (HPA), benzoic acid (BZA), p-hydroxyphenylpyruvic acid (HPY), phenylacetic acid (PAA), phenyllactic acid (PLA), tryptophan (Trp), indoleacetic acid (IAA), phenylpyruvic acid (PPY), phenylpropionic acid (PPA) and cinnamic acid (CNA) in goat rumen fluid was established by high-performance liquid chromatography (HPLC). The mobile phase used for isocratic elution was 50 mM sodium phosphate buffer (pH 6.5)–methanol (97:3, v/v). The flow-rate was 1.0 ml/min; column temperature 40°C and compounds were monitored at 215 nm with a UV absorbance detector after injection of 10 μl of filtered rumen fluid. Analysis was completed within 40 min. The minimum detectable limits of quantification (μM) of these compounds were Tyr, 2; Phe, 3; HBA, 1; HPA, 2; BZA, 2; HPY, 8; PAA, 3; PLA, 4; Trp, 2; IAA, 2; PPY, 15; PPA, 8 and CNA, 4. Detectable levels of Tyr, Phe, HPA, BZA, HPY, PAA, PLA, Trp and PPA were found in the deproteinized rumen fluid of goat fed a haycube and concentrate mixture. PAA was the predominant compound before and after feeding. The concentrations of HPA, BZA, PAA, PLA and PPA in the goat rumen fluid increased after feeding, while the concentration of Tyr decreased. Phe, HPY and Trp were minor components at all times. PPY, IAA and CNA were not detected and HBA was not completely resolved in the goat rumen fluid. 相似文献
15.
High-performance anion exchange chromatography coupled with pulsed amperometric detection was used for the quantitative determination of total and free sugars in olive oil mill waste waters (OMWW). Automated amino acid ion chromatography was employed to analyse total and free amino acids in the same OMWW. Sugars were analysed in samples pre-purified by means of a three-step purification procedure involving: (i) methanol precipitation of OMWW; (ii) dialysis of the obtained solid and liquid fractions; and (iii) chromatographic purification on RP18 phase followed by Amberlite resin. The amino acids were determined directly in samples obtained from the first two steps performed for sugar analysis. The analysis carried out with the reported methodologies allowed the quantitative determination of total sugars and amino acids and the differentiation between their free and bound forms. The sugars determined were arabinose, fructose, galactose, glucose, rhamnose, xylose, galacturonic and glucuronic acids, and the amino acids were Asp, Glu, Thr, Ser, Pro, Gly, Ala, Val, Met, Ile, Leu, Tyr, Phe, Lys, His, Arg and Cys. Asn, Gin, and Trp were not detected. The technological, biotechnological and environmental advantages arising from this analytical methodology applied to OMWW are briefly discussed. 相似文献
16.
利用反相高效液相色谱法同时分析食用菌中7种有机酸,优化后的色谱条件为:Green ODS-AQ柱(4.6mm×250mm,5μm),流动相为10mmol/L的磷酸二氢钾(pH2.8),流速为1.0mL/min,柱温30℃,检测波长为210nm,进样量10μL。该方法精密度、重复性、稳定性实验中7种有机酸的RSD值均小于5%,加样回收率在94.6%–99.3%之间;该方法简便,可应用于食用菌中7种有机酸的检测。运用建立的方法测定了8种食用菌中7种有机酸成分,结果发现不同食用菌中有机酸的种类和含量均差异显著。 相似文献
17.
Fernández-Fígares I Rodríguez LC González-Casado A 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,799(1):73-79
Free amino acids in plasma, muscle and liver tissues were determined using the Pico-Tag method which involves HPLC and pre-column derivatization. A study of the accuracy in the determination is carried out by means of external calibration, standard-added calibration, Youden calibration and analyte recovery. It is conclusively shown that the method is affected by a proportional systematic error due to matrix effects, but not by a constant one. A new function named matrix-corrected calibration is proposed to correct for proportional bias when free analyte matrices for matrix-matched addition is unavailable. 相似文献
18.
In an attempt to simultaneously detect molecules generated through the metabolism of l-arginine, a high-performance liquid chromatography method with on-line time-controlled preinjection reaction of ortho-phthaldialdehyde derivatization was developed. Plasma concentrations of citrulline, N(G)-hydroxy-l-arginine, N(G)-monomethyl-l-arginine, asymmetric N (G), N (G)-dimethyl-l-arginine, symmetric N (G), N (G')-dimethyl-l-arginine, ornithine, and agmatine were analyzed within 35min, using only 20microl of sample, pretreated by a simple cold ethanol cleanup procedure. Plasma samples of 35 healthy human volunteers were analyzed and results were comparable to other published data. All detection parameters of the method demonstrate that it is a reliable and efficient means for the comprehensive determination of arginine and its metabolites, making this approach suitable for routine clinical applications. 相似文献
19.
Summary. A technique is described for the enantiomeric determination of L- and D-amino acids. It works on the principle that the separation
efficiency of high-performance liquid chromatography is coupled with the specificity of enzymes and the sensitivity of electrochemical
detection. After separation on a lithium cation-exchange column the amino acids are converted into keto acids and hydrogen
peroxide under catalyzation of L- or D-amino acid oxidase. Hydrogen peroxide is detected amperometrically. The method has
been tested by the analysis of beer, port, sherry, wine and fruit juice.
A main emphasis was put onto the determination of D-alanine which can serve as an indicator for bacterial contamination. It
is shown that a coupling of HPLC with enzyme reactors is a suitable technique for the rapid detection of this marker.
Received April 14, 1999, Accepted September 15, 1999 相似文献
20.
Naphthalenedialdehyde (NDA) in the presence of cyanide (CN) reacts with primary amines to produce fluorescent cyano[f]benzoisoindole (CBI) derivatives. These derivatives have been shown to be substantially more stable than the corresponding o-phthalaldehyde derivatives. However, one drawback of this method is that compounds derivatized at more than one site exhibit quenching, precluding the use of fluorescence detection. The CBI derivatives have been found to be electroactive and are oxidized at a modest oxidation potential (+750 mV). Electrochemical detection is especially useful for the analysis of compounds containing more than one primary amine site because the response is not attenuated as it is in fluorescence detection. Desmosine and isodesmosine were of particular interest because of their importance in elastic fiber and the lack of highly sensitive HPLC methods for the determination of these compounds. Both of these compounds react with NDA/CN to produce electrochemically active derivatives. The combination of derivatization with NDA/CN and electrochemical detection was found to be linear over three orders of magnitude. Detection limits for CBI-lysine and CBI-desmosine were 100 fmol at a S/N of 2. Amino acids in elastin were quantitated using this method. The results correlate well with what has been reported previously in the literature. A significant advantage of the use of liquid chromatography with electrochemical detection with precolumn derivatization with NDA/CN for the analysis of desmosine and isodesmosine is that they can be separated and quantitated individually using this method. In addition, the unique voltammetry of multiderivatized CBI-amino acids can be used to verify peak purity. 相似文献