共查询到20条相似文献,搜索用时 9 毫秒
1.
Rapid quantitative analysis of a gibberellin-sterol inhibitor using high-performance liquid chromatographic cartridge columns 总被引:1,自引:0,他引:1
Craighton S. Mauk C. Richard Unrath Sylvia M. Blankenship 《Journal of Plant Growth Regulation》1990,9(1-3):181-184
A rapid, sensitive, and economical chemical analysis of the triazole, gibberellin-inhibitor, paclobutrazol (PP333, [(2RS,3RS)-1-(4-chlorophenyl)-4,4-dimethyl-2-(1,2,4 triazol-1-yl) pentan-3-ol]) was sought, featuring high-performance liquid chromatography (HPLC) as the final quantitation step. Three C18-reverse phase columns (conventional, 250×4.6 mm; cartridge type, 125×4.6 mm; and minicolumn, 33×4.6 mm) were evaluated for their performance in HPLC separation and quantitation of PP333 applied to soil and plant foliage. The 125-mm Whatman Partisil 5 ODS-3 cartridge column was superior to the standard 250-mm DuPont Zorbax ODS unit, and provided enhanced resolution and reduced solvent consumption, analysis time, and cost. A Perkin-Elmer Pecosphere 3×3C-C18 cartridge system was also superior to the 125-mm column with respect to these parameters. Although this minicolumn necessitated an additional purification step prior to HPLC analysis, its exceptionally fast analysis time and recovery period coupled with a high degree of sensitivity rendered it the most superior unit. This HPLC technology provided an efficient means of assaying for PP333 in large-scale experiments dealing with the chemical's absorption, translocation, and physiological response. 相似文献
2.
Craighton S. Mauk C. Richard Unrath Sylvia M. Blankenship 《Journal of Plant Growth Regulation》1990,9(1-4):181-184
A rapid, sensitive, and economical chemical analysis of the triazole, gibberellin-inhibitor, paclobutrazol (PP333, [(2RS,3RS)-1-(4-chlorophenyl)-4,4-dimethyl-2-(1,2,4 triazol-1-yl) pentan-3-ol]) was sought, featuring high-performance liquid chromatography (HPLC) as the final quantitation step. Three C18-reverse phase columns (conventional, 250×4.6 mm; cartridge type, 125×4.6 mm; and minicolumn, 33×4.6 mm) were evaluated for their performance in HPLC separation and quantitation of PP333 applied to soil and plant foliage. The 125-mm Whatman Partisil 5 ODS-3 cartridge column was superior to the standard 250-mm DuPont Zorbax ODS unit, and provided enhanced resolution and reduced solvent consumption, analysis time, and cost. A Perkin-Elmer Pecosphere 3×3C-C18 cartridge system was also superior to the 125-mm column with respect to these parameters. Although this minicolumn necessitated an additional purification step prior to HPLC analysis, its exceptionally fast analysis time and recovery period coupled with a high degree of sensitivity rendered it the most superior unit. This HPLC technology provided an efficient means of assaying for PP333 in large-scale experiments dealing with the chemical's absorption, translocation, and physiological response. 相似文献
3.
Anion-exchange high-performance liquid chromatographic analysis of inositol phosphates 总被引:1,自引:0,他引:1
The analysis of inositol phosphates by anion-exchange HPLC is described. The method employs a citrate buffer gradient to resolve several inositol phosphates including inositol 1-phosphate, inositol 1,4-bisphosphate (IP2), and inositol 1,4,5-trisphosphate (IP3), as well as some of the isomers of these compounds. Since the buffer system does not contain any phosphate, we can use a phosphate assay to examine the chromatographic behavior of phosphate-containing compounds. The method shows good resolution and recovery (greater than 95% for IP2 and IP3). Total analysis time, including reequilibration, is about 90 min. In addition, an isocratic system that can rapidly (less than 10 min) measure IP3 is described. The HPLC system was used to characterize inositol phosphate turnover in thrombin-stimulated platelets and formylmethionyl-leucyl-phenylalanine-stimulated HL-60 cells. 相似文献
4.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,691(1):173-178
A rapid high-performance liquid chromatographic method for determination of the dansyl derivative of pentaazapentacosane (PAPC) pentahydrochloride has been developed. The chromatographic system uses a reversed-phase C8 column, a mobile phase of acetic acid buffer and acetonitrile and UV detection. The dansylation conditions were optimized with a pH of 11.0 and a 20-fold dansyl chloride excess. The yield of dansyl PAPC increased 10-fold as the reaction pH was changed from 9.5 to 10.5. Under derivatization conditions of pH 8.5–11.0 and 1–30-fold excess dansyl chloride only perdansyl PAPC was found. 相似文献
5.
Problems encountered in obtaining reliable analytical data by HPLC for the free nucleotide constituents of plant tissues are considered and methods of overcoming them experimentally assessed. Major problems include suppression of residual phosphatase activity during extraction, and removal of pigments, phenolics, alkaloids, and other uv-absorbing nonnucleotides, prior to HPLC. An optimal combination of extraction and pre-HPLC purification techniques is discussed which, in combination with HPLC by anion exchange, yields quantitatively reliable data. The optimized procedure involves extraction with a monophasic mixture of methanol: chloroform:formic acid:water and purification of the nucleotide extract by a batch treatment with poly-N-vinylpyrrolidone, followed by ligand-exchange chromatography. The main HPLC separation uses mu Bondapak NH2 in a linear phosphate gradient and gives good resolution of all the commonly occurring plant nucleotides in a single chromatographic run. 相似文献
6.
A O Brinkmann J Bolt-de Vries W De Boer L M Lindh E Mulder H J van der Molen 《Journal of steroid biochemistry》1985,22(1):85-90
Androgen, estrogen and progesterone receptors have been characterized with anion exchange Fast Protein Liquid Chromatography (FPLC) on a Mono Q column (Pharmacia). In the presence of sodium molybdate androgen receptors in cytosols from rat prostate, rat epididymis and calf uterus eluted as a single sharp peak at 0.32 M NaCl with recoveries of approx 90%. The molybdate-stabilized form of the androgen receptor from rat prostate was purified about 75-fold. The receptor containing FPLC-peak fractions sedimented in high salt (0.4 M KCl) linear sucrose gradients at 3.6 S (prostate) and at 4.6 S (epididymis and calf uterus) respectively. Multiple forms of the androgen receptor were present in cytosols from rat prostate prepared in the absence of sodium molybdate, probably due to proteolytic breakdown of the native form. Calf uterine estradiol and progesterone receptors prepared in the presence of sodium molybdate (20 mM) eluted from the Mono Q column at 0.32 M NaCl. The molybdate-stabilized forms of the oestradiol and progesterone receptors were purified approx 70-fold and 30-fold respectively. In the absence of molybdate the estradiol receptor dissociated into two major forms eluting at 0.23 M NaCl and 0.37 M NaCl. After heat induced transformation (30 min at 25 degrees C) of the estradiol receptor one major peak was eluted at 0.42 M NaCl, indicating a change in the surface charge of the estradiol receptor as a result of the 4 S to 5 S transformation. It is concluded that the FPLC anion exchange system is a powerful, fast tool for characterization and partial purification of steroid receptors. In addition this technique could be applied as a rapid procedure for the quantitative estimation of steroid receptors in small biological samples. 相似文献
7.
E Neufeld R Chayen N Stern 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,718(2):149
Corticosteroids containing a C21 primary hydroxyl group were derivatised with 9-anthroyl cyanide. The reagent was prepared as a solution in acetonitrile, containing 0.1% triethylamine, at a concentration of 2 mg/ml. Approximately 1 μg of corticosteroid was reacted with 100 μl of this reagent, at 45°C for 2 h. The fluorescent derivatives were separated by HPLC on a silica column, 250×4.6 mm I.D., by stepwise elution, with a mobile phase of 2-propanol–hexane (2:98) for 20 min, followed by 2-propanol–hexane (7:93) from 20 to 40 min. The fluorescence detector was set to 370-nm excitation and 470-nm emission. The relatively low temperature for derivatisation avoided reaction with secondary hydroxyl groups and also prevented thermal degradation of the corticosteroids. 相似文献
8.
Phaik Yeong Cheah Kah Hay Yuen Men Long Liong 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2000,745(2):27
A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25–100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25–100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin. 相似文献
9.
Rocket-powered high-performance liquid chromatographic analysis of plant ascorbate and glutathione 总被引:1,自引:0,他引:1
We describe a robust procedure for the extraction and high-performance liquid chromatographic analysis of L-ascorbate (vitamin C), glutathione (gamma-glutamyl cysteinylglycine), and their respective oxidized forms from various plant tissues. Parameters such as the choice of extraction buffer, tissue disruption technique, sample stability, and separation conditions have all been optimized. In particular we found that the inclusion of the reducing agent dithiothreitol as a "stabilizer" in extracts with high phenolic content actually promoted oxidation of these antioxidants. Further, by using commercially available short "Rocket" HPLC columns in combination with high mobile-phase flow rates, analysis times were reduced to only 6min, making the method suitable for the high-resolution screening of large numbers of samples. 相似文献
10.
Teng XW Wang SW Davies NM 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,796(2):225-231
A simple, rapid and sensitive high-performance liquid chromatographic method was developed for determination of ibuprofen, (+/-)-(R, S)-2-(4-isobutylphenyl)-propionic acid, enantiomers in rat serum. Serum (0.1 ml) was extracted with 2,2,4-trimethylpentane/isopropanol (95:5, v/v) after addition of the internal standard, (S)-naproxen, and acidification with H(2)SO(4). Enantiomeric resolution of ibuprofen was achieved on ChiralPak AD-RH column with ultraviolet (UV) detection at 220 nm without interference from endogenous co-extracted solutes. The calibration curve demonstrated excellent linearity between 0.1 and 50 microg/ml for each enantiomer. The mean extraction efficiency was >92%. Precision of the assay was within 11% (relative standard deviation (R.S.D.)) and bias of the assay was lower than 15% at the limit of quantitation (0.1 microg/ml). The assay was applied successfully to an oral pharmacokinetic study of ibuprofen in rats. 相似文献
11.
N Nagai T Shikii K Mihara H Ogata Y Sasaki 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,709(2):508
A simple and practical high-performance liquid chromatographic analysis has been developed for measuring teniposide (VM26) in human plasma. The present analytical method has improved extraction efficiency from human plasma, therefore allowing determination of VM26 in a clinical setting using ultraviolet detection alone. Furthermore, sample preparation was simplified and shortened through use of a one-step extraction procedure. VM26 and internal standard (ibuprofen) were extracted from human plasma (0.5 ml) with ethyl acetate. A phenyl μBondapak column eluted with a mobile phase, consisting of acetonitrile–distilled water–acetic acid (30:68:2, v/v/v) was used for separation, and quantitation was achieved with a UV monitor set at 240 nm. Average extraction efficiency was 96.8±6.6% for VM26 between 1 and 25 μg/ml, and 91.4±4.3% for internal standard, with both intra- and inter-day coefficients of variation being less than 10%. The detection limit with a 100-μl injection was estimated at 0.2 μg/ml with a signal-to-noise ratio of 3 for VM26 in human plasma. The stability data of VM26 in plasma, standard and stock solutions were also obtained. The present method was found to be an alternative to the previously reported method with an electrochemical detection, and can be easily applied to routine clinical pharmacokinetic studies of VM26. 相似文献
12.
13.
A reversed-phase high-performance liquid chromatographic method for characterization of biosynthetic human growth hormone 总被引:1,自引:0,他引:1
An isocratic reversed-phase high-performance liquid chromatographic method for the determination of human growth hormone (HGH) purity is described. This method offers superior resolution of HGH-related substances (e.g., sulfoxide and desamido derivatives) from unmodified HGH when compared to a number of alternative chromatographic and electrophoretic techniques. 相似文献
14.
Phosphorylation of steroid hormone receptors 总被引:1,自引:0,他引:1
V K Moudgil 《Biochimica et biophysica acta》1990,1055(3):243-258
15.
Vadim Klyushnichenko Alice Bernier Amine Kamen Eef Harmsen 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,755(1-2)
We developed a HPLC method on a novel continuous bed matrix (UNO Q, Bio-Rad) for the direct quantification of adenoviral type 5 (Ad5) particles produced in 293S Human Embryonic Kidney cells and compared this with an existing HPLC method on a conventional ion-exchange resin (Resource Q, Pharmacia). The 293S cell extract contained large amounts of DNA. This contaminated the viral peak on the Resource Q column and only after Benzonase treatment was it possible to quantify the viral particles in the cell extract. In contrast, the virus peak on the UNO Q column was resolved from the DNA which eliminates the need for pretreatment of the sample with Benzonase. Cross-analysis of the Ad5 fraction from the UNO Q column using a size-exclusion HPLC column revealed no additional contaminating peaks. We conclude that the purity of the Ad5 virus peak on the continuous bed matrix UNO Q column was superior to the purity of the virus on the conventional Resource Q column, which is essential for reliable quantification. 相似文献
16.
E Gamelin M Boisdron-Celle A Turcant F Larra P Allain J Robert 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,695(2):972
Recent studies have stressed the need for individual adjustment of 5-fluorouracil (5-FU) dosage. Most of the techniques previously reported are not well adapted to routine application. We describe a sensitive, selective and simple HPLC technique under isocratic conditions for the quantitation of 5-FU and other halogenopyrimidines. The proportion of reagents and internal standard were optimised to allow the use of minitubes, particularly adapted to large series of plasma assays. High extraction yield, 75% for 5-FU and 90% for 5-bromouracil and 5-chlorouracil, was obtained using 1.2 ml isopropanol–ethyl acetate (15:85, v/v) following precipitation of plasma proteins with 300 mg ammonium sulfate. The mobile phase was 0.01 M phosphate buffer (pH 3.0). Uracil and 5-fluorouracil were fully resolved with Spherisorb ODS2 column. The limits of quantitation and detection in human plasma were 6 ng ml−1 and 3 ng ml−1, respectively, for all compounds studied. The total analysis time required for each run was 25 min. Final results could be given within 90 min of blood sampling. At least 50 plasma samples could be analysed per day. This method has been successfully used for monitoring 5-FU-based treatments. 相似文献
17.
18.
M. Masood Bhatti Robert T. Foster 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,579(2)
A valid, sensitive high-performance liquid chromatographic technique is reported for the separation of the two enantiomers of metoprolol in human plasma. The procedure involves pre-column derivatization with the homochiral reagent S-(+)-1-(1-naphthyl)-ethyl isocyanate. Once formed, the diastereomers are separated using normal-phase high-performance liquid chromatography. Fluorescence detection (220 nm excitation; no emission filter) was utilized, resulting in baseline resolution (Rs > 1.5). The peaks corresponding to metoprolol enantiomers were free from interference throughout the examined range of 5–500 ng/ml; accuracy and precision were within approximately 10%. Analysis of a plasma sample collected from a healthy volunteer demonstrated that the assay is applicable to clinical studies. 相似文献
19.
Anne Guiochon-Mantel Karine Delabre Pierre Lescop Edwin Milgrom 《The Journal of steroid biochemistry and molecular biology》1996,56(1-6):3-9
The signal responsible for the nuclear localization of the progesterone receptor has been characterized. It is a complex signal. The study of the mechanism of this nuclear localization has revealed that the receptor continuously shuttles between the nucleus and the cytoplasm. The receptor diffuses into the cytoplasm and is constantly and actively transported back into the nucleus. The same phenomenon exists for estradiol and glucocorticoid receptors. The mechanism of entry of proteins into the nucleus is well documented, whereas the mechanism of their outward movement into the cytoplasm is not understood. We have grafted different nuclear localization signals (NLSs) onto β-galactosidase and have studied the traffic of this protein using heterokaryons and microinjection experiments. We have demonstrated that the same NLSs are involved in both the inward and the outward movement of proteins through the nuclear membrane. These results suggest that the nucleocytoplasmic shuttling may be a general phenomenon for nuclear proteins that could possibly undergo modifications in the cytoplasm and exert some biological activities there. These conclusions also imply that at least part of the cellular machinery involved in the nuclear import of proteins may function bidirectionally. Using these techniques, we have shown that two major antiprogestins, RU486 and ZK98299, act at the same distal level of hormone action. 相似文献
20.
It is shown that the testosterone content in skeletal muscles of female albino rats is 2-fold decreased, while the estradiol content-1.5-fold increased and progesteron content showed no changes after systematic physical exercises. The pharmacokinetic investigations showed that androgen half-life in the organism decreased from 8 to 5 h under physical exercises. The amount of androgen receptors in cytosol of skeletal muscles increases from 1.34 +/- 0.08 to 1.71 +/- 0.10 fmol/mg per 1 mg of protein. Kd is 0.40 +/- 0.03 and 0.48 +/- 0.08 nM, respectively. Sensitivity of the organism to hormonal signal play an important role in the metabolism regulation in skeletal muscles along with the hormonal content change during the organism adaptation to physical exercises. 相似文献