首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A biosensor model was developed for a commercial NADH fluorescence probe to describe the single-frequency excitation and emission fluorescence behavior of an aqueous mixture of fluorophores. This model is essential in correlating the measured signals to the concentrations of fluorescent compounds in a bioreactor. In addition to the concentrations of fluorescent components, the relevant parameters of the model are the absorbance at both the excitation and the emission frequencies by the solvent and other absorbing species, the background signals, the light path length of the bioreactor vessel, the fluorescence yield, and the lampdetector configuration. Due to inner-filter effects and other interferences, the probe signal is intrinsically nonlinear in both the fluorophore concentration and the path length. An important parameter in the model is the geometric constant, S, which accounts for variations in the monitoring efficiency throughout the sample because fluorescent light is emitted in all directions. Previous models, derived from an unrealistic assumption that fluorescent light is emitted only in one direction parallel to the probe axis, are shown to be seriously deficient. The validity of the model was verified experimentally for a single-component solution in which both the fluorophore concentration and path length were varied.  相似文献   

2.
Time-resolved fluorescence of the single tryptophan residue Trp41 in fragment 1-86 of factor X (FX F1-86) is studied using a time-correlated single photon counting technique with synchrotron radiation as the excitation source. Calcium ions are believed to induce a conformational change in the N-termini of the activated factor X and other vitamin K dependent proteins, which is accompanied by a decrease in fluorescence intensity. The titration with calcium yields a sigmoidal fluorescence titration curve with a transition midpoint concentration of 0.44 mM. The wavelength-dependent tryptophan fluorescence decays of the apo-FX F1-86 (in the absence of calcium) and Ca-FX F1-86 are characterized by conventional multiexponential analysis and fluorescence lifetime distribution analysis. In the absence of calcium there are three significant classes of fluorescence lifetimes (ns) that are nearly wavelength independent: 0.55 +/- 0.08 (component A), 2.6 +/- 0.1 (component B), and 5.3 +/- 0.3 (component C). However, their preexponential amplitudes vary with wavelength. The decay associated emission spectra of the individual components show that components B and C contribute over 85% to the total fluorescence for all examined wavelengths. However, in the presence of calcium, the analysis of the time-resolved fluorescence data of Ca-FX F1-86 yields four wavelength-independent lifetimes (ns) of 0.30 +/- 0.09 (component D), 0.65 +/- 0.10 (component A), 2.7 +/- 0.2 (component B), and 5.4 +/- 0.3 (component C). Calcium addition to the apo-FX F1-86 leads to a decrease in the fluorescence intensities of components B and C while their decay times remain unaffected. In Ca-FX F1-86 an additional component D arises that has a decay time of 0.30 ns and that contributes up to 35% to the total fluorescence intensity. A comparison with a previous investigation of prothrombin fragment 1 demonstrates the extensive structural and functional homology between the N termini of prothrombin and factor X(a).  相似文献   

3.
The detailed process of excitation transfer among the antenna pigments of the red alga Porphyra perforata was investigated by measuring time-resolved fluorescence emission spectra using a single-photon timing system with picosecond resolution. The fluorescence decay kinetics of intact thalli at room temperature revealed wavelength-dependent multi-component chlorophyll a fluorescence emission. Our analysis attributes the majority of chlorophyll a fluorescence to excitation originating in the antennae of PS II reaction centers and emitted with maximum intensities at 680 and 740 nm. Each of these fluorescence bands was characterized by two kinetic decay components, with lifetimes of 340-380 and 1700-2000 ps and amplitudes varying with wavelength and the photochemical state of the PS II reaction centers. In addition, a small contribution to the long-wavelength fluorescence band is proposed to arise from chlorophyll a antennae coupled to PS I. This component displays fast decay kinetics with a lifetime of approx. 150 ps. Desiccation of the thalli dramatically increases the contribution of this fast decay component.  相似文献   

4.
Seven fluorescent microsphere colors can be used in a single experiment to estimate regional blood flow without correcting for spillover of emitted fluorescence. To extend the method to 13 colors, we compared the accuracy of three methods for spillover correction. Fixed wavelength intensities were corrected by matrix inversion, and synchronous scan spectra were corrected by least squares fit of an overdetermined system of linear equations and by least squares fit of a sum of Gaussian and Lorentzian functions. Correction methods were validated in pigs and sheep by simultaneous injections of radioactive microspheres and fluorescent microspheres of 7, 10, and 13 different colors. We induced extreme changes in flow to create regions with low fluorescent signals bound on either side by high fluorescent signals. Blood flow was determined by radioactivity and by fluorescence using both fixed excitation and emission wavelength pairs and synchronous scanning and then corrected for spillover. Correlation between fluorescent intensity and radioactivity were excellent for all three correction methods [R2 = 0.98 +/- 0.02 (mean +/- SD)]. Low-flow regions requiring large spillover correction had systematic errors for some color combinations in all methods. We conclude that for 13 fluorescent colors spillover error can be minimized so that all three correction methods provide accurate estimates of regional blood flow.  相似文献   

5.
报道了一种利用单一波长激发的同时产生光声和荧光信号的显微成像系统,本成像系统具有超高的成像分辨率(<6μm)。借助外源的造影剂在近红外的吸收特性,利用光声-荧光显微成像系统对活体肿瘤进行光声/荧光成像。实验结果表明,光声-荧光显微镜在早期肿瘤的成像和检测等方面具有潜在的应用价值。因此,通过研究和选择适当的双模态造影剂,该系统在不同病理模型中可以提供更准确的组织信息及生理参数。  相似文献   

6.
The fluorescence decays of barley chloroplasts have been measured by single-photon counting with tunable picosecond dye laser excitation. The fluorescence decays of dark-adapted chloroplasts are best fitted to a sum of three exponential lifetime components with lifetimes of 112, 380 and 2214 ps. The relative magnitude of each component is shown to be dependent on the excitation wavelength and collected emission wavelength. The excitation wavelength dependence is correlated with the Photosystem (PS) I and PS II action study of Ried [36] and with the measured pigment distributions in the photosynthetic unit [37,41]. Experiments varying the single excitation pulse intensity from 108 to 1012 photons/cm2 pulse show that our results are not distorted by singlet-singlet annihilation. Unflowed samples where the cloroplasts are under constant illumination show 2-fold increases in quantum yield of fluorescence primarily in the two longer lifetime components. Theoretical calculations of Shipman [31] on an isolated reaction center with a homogeneous antenna are discussed and the principles extended to discussion of the measured barley chloroplast fluorescence decay components in terms of photosynthetic unit light-harvesting array models and earlier experimental work. Our data support a photosynthetic unit model in which 70–90% of the photons absorbed are quenched by either PS I or efficiently quenching PS II in a process where the fluorescence lifetime is 100 ps. The origin of the intermediate 380 ps. component is probably due to excitation transfer to a PS II reaction center in a redox state which quenches less efficiently.  相似文献   

7.
用于浮游植物探测的三维激光诱导荧光光谱系统   总被引:1,自引:0,他引:1  
本文介绍一个针对浮游植物现场探测的三维激光诱导荧光(3D-LIF)光谱系统。该系统以波长可调谐激光器为光源,使用光栅光谱仪进行光谱分光,输出光谱范围380 nm ~800 nm,并选用32通道光电倍增管模组作为光电探测器。光栅光谱仪和光电倍增管模组之间的耦合选用芯径0.2 mm 的光纤束,对应光谱分辨率约为3 nm,以此采集接收的31通道发射荧光光谱,其光谱范围为410 nm ~710 nm,光谱带宽约10 nm。光电转换电路的模拟带宽约为20 MHz,数据采集频率50 MHz,分辨率14 bit。基于研发的光谱系统,采用光学参量放大器(OPO)以获得405 nm ~615 nm 可调谐激发光源,在实验室对三十余种中国海常见的浮游植物的3D-LIF 光谱进行了测量。测量结果证实了系统的稳定性和用于藻种分类和识别研究的有效性。系统中的激光器和望远镜可灵活更换,接收的光谱范围和光谱分辨率等参数可便利调节,因此,该系统可望发展成为用于现场探测的3D-LIF 光谱系统。  相似文献   

8.
Recent advances in thin film optical coating technology significantly improve the filters available for fluorescence spectroscopy. Bandpass and long- and shortpass filters with very sharply defined edges can provide from 10(-5) to 10(-6) blocking within 10-15 nm of the transmission region and are ideal for use as excitation and emission filters. A variety of nonpolarizing dichroic beamsplitters for use in epi-illumination configurations or in multiple emission configurations provides optimum longpass, shortpass, band reflection, or bandpass spectral control. These dichroics, used with high-performance bandpass, longpass, or shortpass filters, form matched sets that optimize the signal-to-noise ratio and system efficiency for fluorescence spectroscopic systems in single or multiple dye applications. Specially designed dichroic beamsplitters are used to reduce excitation filter overheating. Other dichroic beamsplitters efficiently separate two planes of polarization in a narrow wavelength band. Rejection band filters can be used to measure the fluorescent dye Indo 1 with very low emission signals.  相似文献   

9.
K Ajtai  T P Burghardt 《Biochemistry》1989,28(5):2204-2210
We describe a protocol for the selective covalent labeling of the sulfhydryl 2 (SH2) on the myosin cross-bridge in glycerinated muscle fibers using the sulfhydryl-selective label 4-[N-[(iodoacetoxy)ethyl]-N-methylamino]-7-nitrobenz-2-oxa-1,3-diazole (IANBD). The protocol promotes the specificity of IANBD by using the ability to protect sulfhydryl 1 (SH1) from modification by binding the cross-bridge to the actin filament and using cross-bridge-bound MgADP to promote the accessibility of SH2. We determined the specificity of the probe using fluorescence gel scanning of fiber-extracted proteins to isolate the probe on myosin subfragment 1 (S1), limited proteolysis of the purified S1 to isolate the probe on the 20-kilodalton fragment of S1, and titration of the free SH1's on purified S1 using the radiolabeled SH1-specific reagent [14C]iodoacetamide or enzymatic activity measurements. We estimated the distribution of the IANBD on the fiber proteins to be approximately 77% on SH2, approximately 5% on SH1, and approximately 18% on troponin I. We characterized the angular distribution of the IANBD on cross-bridges in fibers when the fibers are in rigor, in relaxation, in the presence of MgADP, and in isometric contraction using wavelength-dependent fluorescence polarization [Ajtai, K., & Burghardt, T. P. (1987) Biochemistry 26, 4517-4523]. With wavelength-dependent fluorescence polarization we use the ability to rotate the transition dipole in the molecular frame using excitation wavelength variation to investigate the three angular degrees of freedom of the cross-bridge.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
Changes in the fluorescein fluorescence emission and excitation polarization spectra in synchronized cultured S3 fibroblasts at G1, mid-S, and mitosis, as well as in human lymphocytes before and after stimulation with mitogens, were studied. In contrast to those measured in aqueous solutions the emission and excitation polarization spectra in living cells exhibit a wavelength dependence characteristic for the state of the cell cycle. Changes in the temperature and in the amount of intracellular water result in quantitative wavelength-independent changes in the polarization spectra. Possible mechanisms for the qualitative wavelength-dependent changes in the fluorescein emission and excitation polarization spectra during the cell cycle are discussed.  相似文献   

11.
Fluorometric determination of the chlorophyll (Chl) content of cyanobacteria is impeded by the unique structure of their photosynthetic apparatus, i.e., the phycobilisomes (PBSs) in the light-harvesting antennae. The problems are caused by the variations in the ratio of the pigment PC to Chl a resulting from adaptation to varying environmental conditions. In order to include cyanobacteria in fluorometric analysis of algae, a simplified energy distribution model describing energy pathways in the cyanobacterial photosynthetic apparatus was conceptualized. Two sets of mathematical equations were derived from this model and tested. Fluorescence of cyanobacteria was measured with a new fluorometer at seven excitation wavelength ranges and at three detection channels (650, 685 and 720 nm) in vivo. By employing a new fit procedure, we were able to correct for variations in the cyanobacterial fluorescence excitation spectra and to account for other phytoplankton signals. The effect of energy-state transitions on the PC fluorescence emission of PBSs was documented. The additional use of the PC fluorescence signal in combination with our recently developed mathematical approach for phytoplankton analysis based on Chl fluorescence spectroscopy allows a more detailed study of cyanobacteria and other phytoplankton in vivo and in situ.  相似文献   

12.
Molecular sensors based on intramolecular Förster resonance energy transfer (FRET) have become versatile tools to monitor regulatory molecules in living tissue. However, their use is often compromised by low signal strength and excessive noise. We analyzed signal/noise (SNR) aspects of spectral FRET analysis methods, with the following conclusions: The most commonly used method (measurement of the emission ratio after a single short wavelength excitation) is optimal in terms of signal/noise, if only relative changes of this uncalibrated ratio are of interest. In the case that quantitative data on FRET efficiencies are required, these can be calculated from the emission ratio and some calibration parameters, but at reduced SNR. Lux-FRET, a recently described method for spectral analysis of FRET data, allows one to do so in three different ways, each based on a ratio of two out of three measured fluorescence signals (the donor and acceptor signal during a short-wavelength excitation and the acceptor signal during long wavelength excitation). Lux-FRET also allows for calculation of the total abundance of donor and acceptor fluorophores. The SNR for all these quantities is lower than that of the plain emission ratio due to unfavorable error propagation. However, if ligand concentration is calculated either from lux-FRET values or else, after its calibration, from the emission ratio, SNR for both analysis modes is very similar. Likewise, SNR values are similar, if the noise of these quantities is related to the expected dynamic range. We demonstrate these relationships based on data from an Epac-based cAMP sensor and discuss how the SNR changes with the FRET efficiency and the number of photons collected.  相似文献   

13.
蛇毒中含有多种金属蛋白质,它们具有不同的生物学活性,如抗凝血因子(ACF)、糖苷水解酶(NADase)、纤溶组分(FP)及出血毒素等,它们的许多生物活性、荧光光谱和结构的性质等方面的研究已见报道[1].徐洵等[2]从皖南尖吻蝮蛇蛇毒中分离出3种出血毒...  相似文献   

14.
The fluorescence decay spectra and the excitation energy transfer from the phycobiliproteins (PBP) to the chlorophyll-antennae of intact cells of the chlorophyll (Chl) d-dominated cyanobacterium Acaryochloris marina were investigated at 298 and 77 K by time- and wavelength-correlated single photon counting fluorescence spectroscopy. At 298 K it was found that (i) the fluorescence dynamics in A. marina is characterized by two emission peaks located at about 650 and 725 nm, (ii) the intensity of the 650 nm fluorescence depends strongly on the excitation wavelength, being high upon excitation of phycobiliprotein (PBP) at 632 nm but virtually absent upon excitation of chlorophyll at 430 nm, (iii) the 650 nm fluorescence band decayed predominantly with a lifetime of 70 +/- 20 ps, (iv) the 725 nm fluorescence, which was observed independent of the excitation wavelength, can be described by a three-exponential decay kinetics with lifetimes depending on the open or the closed state (F(0) or F(m)) of the reaction centre of Photosystem II (PS II). Based on the results of this study, it is inferred that the excitation energy transfer from phycobiliproteins to Chl d of PS II in A. marina occurs with a time constant of about 70 ps, which is about three times faster than the energy transfer from the phycobilisomes to PS II in the Chl a-containing cyanobacterium Synechococcus 6301. A similar fast PBP to Chl d excitation energy transfer was also observed at 77 K. At 77 K a small long-lived fluorescence decay component with a lifetime of 14 ns was observed in the 640-700 nm spectral range. However, it has a rather featureless spectrum, not typical for Chl a, and was only observed upon excitation at 400 nm but not upon excitation at 632 and 654 nm. Thus, this long-lived fluorescence component cannot be used as an indicator that the primary PS II donor of Acaryochloris marina contains Chl a.  相似文献   

15.
A simple and sensitive high-performance liquid chromatographic (HPLC) method has been developed for the determination of five different quinolones: enrofloxacin, ciprofloxacin, sarafloxacin, oxolinic acid and flumequine in pork and salmon muscle. The method includes one extraction and clean-up step for the five quinolones together which are detected in two separated HPLC runs by means of their fluorescence. The proposed analytical method involves homogenizing of the tissue sample with 0.05 M phosphate buffer, pH 7.4 and clean-up by Discovery DS-18 cartridges. For chromatographic separation a Symmetry C(18) column is used in two different runs: (1) ciprofloxacin, enrofloxacin and sarafloxacin with acetonitrile-0.02 M phosphate buffer pH 3.0 (18:82) as mobile phase and the detector at excitation wavelength: 280 nm and emission wavelength 450 nm; and (2) oxolinic acid and flumequine with acetonitrile-0.02 M phosphate buffer pH 3.0 (34:66) as mobile phase and excitation wavelength: 312 nm and emission wavelength: 366 nm. Detection limit was as low as 5 ng g(-1), except for sarafloxacin which had a limit of 10 ng g(-1). Standard curves using blank muscle tissues spiked at different levels showed a good linear correlation coefficient, r(2) higher than 0.999 for all quinolones.  相似文献   

16.
Multiphoton excitation microscopy at 730 nm and 960 nm was used to image in vivo human skin autofluorescence from the surface to a depth of approximately 200 microm. The emission spectra and fluorescence lifetime images were obtained at selected locations near the surface (0-50 microm) and at deeper depths (100-150 microm) for both excitation wavelengths. Cell borders and cell nuclei were the prominent structures observed. The spectroscopic data suggest that reduced pyridine nucleotides, NAD(P)H, are the primary source of the skin autofluorescence at 730 nm excitation. With 960 nm excitation, a two-photon fluorescence emission at 520 nm indicates the presence of a variable, position-dependent intensity component of flavoprotein. A second fluorescence emission component, which starts at 425 nm, is observed with 960-nm excitation. Such fluorescence emission at wavelengths less than half the excitation wavelength suggests an excitation process involving three or more photons. This conjecture is further confirmed by the observation of the super-quadratic dependence of the fluorescence intensity on the excitation power. Further work is required to spectroscopically identify these emitting species. This study demonstrates the use of multiphoton excitation microscopy for functional imaging of the metabolic states of in vivo human skin cells.  相似文献   

17.
The genetically encoded voltage indicators ArcLight and its derivatives mediate voltage-dependent optical signals by intermolecular, electrostatic interactions between neighboring fluorescent proteins (FPs). A random mutagenesis event placed a negative charge on the exterior of the FP, resulting in a greater than 10-fold improvement of the voltage-dependent optical signal. Repositioning this negative charge on the exterior of the FP reversed the polarity of voltage-dependent optical signals, suggesting the presence of “hot spots” capable of interacting with the negative charge on a neighboring FP, thereby changing the fluorescent output. To explore the potential effect on the chromophore state, voltage-clamp fluorometry was performed with alternating excitation at 390 nm followed by excitation at 470 nm, resulting in several mutants exhibiting voltage-dependent, ratiometric optical signals of opposing polarities. However, the kinetics, voltage ranges, and optimal FP fusion sites were different depending on the wavelength of excitation. These results suggest that the FP has external, electrostatic pathways capable of quenching fluorescence that are wavelength specific. One mutation to the FP (E222H) showed a voltage-dependent increase in fluorescence when excited at 390 nm, indicating the ability to affect the proton wire from the protonated chromophore to the H222 position. ArcLight-derived sensors may therefore offer a novel way to map how conditions external to the β-can structure can affect the fluorescence of the chromophore and transiently affect those pathways via conformational changes mediated by manipulating membrane potential.  相似文献   

18.
In this report, parallax analysis of fluorescence quenching (see the preceding paper in this issue) was used to determine the location (depth) of anthroyloxy and carbazole probes attached to model membrane inserted fatty acids. A monotonic increase in depth was found as the number of carbon atoms between the attachment site of the probe and the fatty acyl carboxyl group is increased. It was also found that depth is sensitive to pH, with an increase in probe depth upon protonation of the fatty acid carboxyl group of around 0.5-2.5 A, depending on probe location and identity. This result shows that carboxyl protonation causes an increase in depth all along a fatty acid chain. In addition, it indicates that parallax analysis is very sensitive to small changes in depth. At a given pH, no significant change in probe depth was observed in vesicles containing anionic phospholipid or at various ionic strengths, suggesting these parameters do not strongly regulate fatty acyl chain location. It was also found that there is a decrease of the apparent depth of each of the fatty acyl attached probes both at longer excitation wavelengths and at longer emission wavelengths. This is consistent with there being a distribution of depth for each fluorophore, with shallower fluorophore dominating the fluorescence at red-shifted wavelengths. Solvent relaxation effects also appear to contribute to this wavelength dependence.  相似文献   

19.
A new fluorescent bioreactor monitoring probe-multiple excitation fluorometric system (MEFS)-has been developed. This probe was compared to the commercially available BioChem Technology FluroMeasure system (NADH probe). In this task the fluorescence behavior of three model fermentation systems, ethanol fermentation by Candida utilis, phenol fermentation by Pseudomonas putida, and glucose fermentation by Saccharomyces cerevisiae, were examined. The results indicated that the fluorescence intensity and behavior of various cellular fluorophors vary significantly between the different fermentation systems. Monitoring a fermentation process using only NAD(P)H fluorescence provided limited information. The NAD(P)H fluorescence was found not to be the best fluorescence signal for monitoring cell concentrations. The best way of monitoring a bioreactor by fluorometry may be to monitor several fluorophors in the whole culture broth simultaneously and to relate these fluorescence signals to various biological parameters.  相似文献   

20.
Fluorometric determination of the chlorophyll (Chl) content of cyanobacteria is impeded by the unique structure of their photosynthetic apparatus, i.e., the phycobilisomes (PBSs) in the light-harvesting antennae. The problems are caused by the variations in the ratio of the pigment PC to Chl a resulting from adaptation to varying environmental conditions. In order to include cyanobacteria in fluorometric analysis of algae, a simplified energy distribution model describing energy pathways in the cyanobacterial photosynthetic apparatus was conceptualized. Two sets of mathematical equations were derived from this model and tested. Fluorescence of cyanobacteria was measured with a new fluorometer at seven excitation wavelength ranges and at three detection channels (650, 685 and 720 nm) in vivo. By employing a new fit procedure, we were able to correct for variations in the cyanobacterial fluorescence excitation spectra and to account for other phytoplankton signals. The effect of energy-state transitions on the PC fluorescence emission of PBSs was documented. The additional use of the PC fluorescence signal in combination with our recently developed mathematical approach for phytoplankton analysis based on Chl fluorescence spectroscopy allows a more detailed study of cyanobacteria and other phytoplankton in vivo and in situ.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号