首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of the present study was to evaluate retropatellar contact characteristics at different angles of flexion of the knee joint. To this end, 6 cadaveric legs were examined using pressure sensitive film (Fuji Prescale type "super low") at angles of flexion of 45 degrees, 60 degrees, 90 degrees and 120 degrees both in neutral rotation and 10 degrees internal and external rotation of the femur in the same knee joints. A force of 140 N was applied to both the vastus medialis and lateralis, and a comparison made with a medially and a laterally dominating muscle force. The contact areas decreased with increasing angles of flexion. The medially dominating muscle traction increased the contact area. Comparison between internal and external rotation revealed a decrease in contact area on internal rotation. The pressure measurements were comparable in all loading situations. Comparison between neutral and medial traction revealed significant differences in contact area, pressure and force. The influence of femoral rotation showed no significant difference. A comparison of the different angles of flexion revealed only few significant differences. To prevent the development of retropatellar arthrosis, maximum contact areas are necessary. The study has shown an advantage for medially dominating muscle traction, and external rotation of the femur.  相似文献   

2.
The objective of this study was to assess how accurately and repeatably the Iscan system measures force and pressure in the natural patellofemoral joint. These measurements must be made to test widely held assumptions about the relationships between mechanics, pain and cartilage degeneration. We assessed the system's accuracy by using test rigs in a materials testing machine to apply known forces and force distributions across the sensor. The root mean squared error in measuring resultant force (for five trials at each of seven load levels) was 6.5±4.4% (mean±standard deviation over all trials at all load levels), while the absolute error was −5.5±5.6%. For force distribution, the root mean squared error (for five trials at each of five force distributions) was 0.86±0.58%, while the absolute error was −0.22±1.03%. We assessed the repeatability of the system's measurements of patellofemoral contact force, pressure and force distribution in four cadaver specimens loaded in continuous and static flexion. Variability in measurement (standard deviation expressed as a percentage of the mean) was 9.1% for resultant force measurements and 3.0% for force distribution measurements for static loads, and 7.3% for resultant force and 2.2% for force distribution measurements for continuous flexion. Cementing the sensor to the cartilage lowered readings of resultant force by 31±32% (mean±standard deviation), area by 24±13% and mean pressure by 9±34% (relative to the uncemented sensor). Maximum pressure measurement, however, was 24±43% higher in the cemented sensor than in the uncemented sensor. The results suggest that the sensor measures force distribution more accurately and repeatably than absolute force. A limitation of our work, however, is that the sensor must be cemented to the patellar articular surface to make the force distribution measurements, and our results suggest that this process reduces the accuracy of force, pressure and area measurements. Our results suggest that the Iscan system's pressure measurement accuracy and repeatability are comparable to that of Fuji Prescale film, but its advantages are that it is thinner than most Fuji Prescale film, it measures contact area more accurately and that it makes continuous measurements of force, pressure and area.  相似文献   

3.
Recently, high-flexion knee implants have been developed to provide for a large range of motion (ROM>120°) after total knee arthroplasty (TKA). Since knee forces typically increase with larger flexion angles, it is commonly assumed that high-flexion knee implants are subjected to larger loads than conventional knee implants. However, most high-flexion studies do not consider thigh–calf contact which occurs during high-flexion activities such as squatting and kneeling. In this study, we hypothesized that thigh–calf contact reduces the knee forces during deep knee flexion as the tibio-femoral load shifts from occurring inside the knee towards the thigh–calf contact interface. Hence, the effect of thigh–calf contact on the knee loading was evaluated using a free body diagram and a finite element model and both the knee forces and polyethylene stresses were analyzed. Thigh–calf contact force characteristics from an earlier study were included and a squatting movement was simulated. In general, we found thigh–calf contact considerably reduced both the knee forces and polyethylene stresses during deep knee flexion. At maximal flexion (155°), the compressive knee force decreased from 4.89 to 2.90 times the bodyweight (BW) in case thigh–calf contact was included and the polyethylene contact stress at the tibial post decreased from 49.3 to 28.1 MPa. Additionally, there was a clear correlation between a subject's thigh and calf circumference and the force reduction at maximal flexion due to thigh–calf contact (R=0.89). The findings presented in this study can be used to optimize the mechanical behavior of high-flexion total knee arthroplasty designs.  相似文献   

4.
Tarsal adhesive pads of insects are highly dynamic organs that play an important role in locomotion. Many insects combine fast running performance with strong resistance to detachment forces. This capacity requires an effective control of attachment forces at the tarsus and pretarsus. Here we investigate mechanisms of attachment control in Asian weaver ants (Oecophylla smaragdina) by measuring the dynamics of the adhesive contact area and the claws during locomotion. O. smaragdina ants walking upside down on a smooth substrate used only a fraction (approx. 14%) of their maximum possible contact area. When these ants were loaded with 30 mg weights (corresponding to approx. 6 times their own body weight), however, they employed much larger (but still submaximal; approx. 60%) contact areas. The increase of contact area was accompanied by a stronger flexion of the claws, which demonstrates the participation of the claw flexor muscle in the control of adhesive contact. However, only part of the contact area dynamics could be explained by the action of the claw flexor. During the stance phase, adhesive contact area changed while the claws remained motionless. Even when corrected for the effects of claw flexion, adhesive contact areas differed by a factor of 2.1 between loaded and unloaded ants. Our findings give evidence that running ants control their adhesive contact area by a combination of active movements of the claw flexor muscle and passive reactions of the mechanical system.  相似文献   

5.
In designing a posterior-stabilized total knee arthroplasty (TKA) it is preferable that when the cam engages the tibial spine the contact point of the cam move down the tibial spine. This provides greater stability in flexion by creating a greater jump distance and reduces the stress on the tibial spine. In order to eliminate edge loading of the femoral component on the posterior tibial articular surface, the posterior femoral condyles need to be extended. This provides an ideal femoral contact with the tibial articular surface during high flexion angles. To reduce extensor mechanism impingement in deep flexion, the anterior margin of the tibial articular component should be recessed. This provides clearance for the patella and patella tendon. An in vivo kinematic analysis that determined three dimensional motions of the femorotibial joint was performed during a deep knee bend using fluoroscopy for 20 subjects having a TKA designed for deep flexion. The average weight-bearing range-of-motion was 125 degrees . On average, TKA subjects experienced 4.9 degrees of normal axial rotation and all subjects experienced at least -4.4 mm of posterior femoral rollback. It is assumed that femorotibial kinematics can play a major role in patellofemoral kinematics. In this study, subjects implanted with a high-flexion TKA design experienced kinematic patterns that were similar to the normal knee. It can be hypothesized that forces acting on the patella were not substantially increased for TKA subjects compared with the normal subjects.  相似文献   

6.
In vivo patellofemoral forces in high flexion total knee arthroplasty   总被引:1,自引:0,他引:1  
This study compares the in vivo patellofemoral contact forces generated in high flexion fixed bearing posterior cruciate retaining Nexgen CR-Flex (PCR) and high flexion posterior stabilized Nexgen LPS-Flex (LPS) TKAs with that of normal knees from full knee extension to maximum weight bearing flexion. Ten patients with the PCR total knee arthroplasty (TKA), ten with the LPS TKA and seven patients having normal knees were fluoroscoped while performing a deep knee bend activity. In vivo femorotibial kinematics, obtained from 3D-to-2D registration technique, and patellar kinematics obtained by direct measurements from the fluoroscopic images were entered into a 3D inverse dynamics mathematical model to determine the in vivo contact forces at the knee. The variation in the patellofemoral and quadriceps forces with flexion were found to be similar across the three groups-increasing from full extension to 90 degrees of flexion, reaching a maximum between 90 degrees and 120 degrees of flexion and then decreasing until maximum flexion. At maximum knee flexion, these forces were found to be significantly lower in the normal knees than in the TKAs. The patellar ligament to quadriceps force ratio decreased with the increase in knee flexion while the patellofemoral to quadriceps force ratio increased. A strong correlation was found to exist between the patellofemoral forces, the femorotibial contact forces and the forces in the extensor mechanism. The PCR TKA in this study exhibited greater resemblance to the normal patients with respect to the patellofemoral forces than the LPS TKA though significant differences in the two implant types were not observed.  相似文献   

7.
OBJECTIVE: Ex vivo studies have suggested that cartilage contact areas and pressure are of high clinical relevance in the etiology of osteoarthritis in patients with patellar subluxation. The aims of this study were therefore to validate in vivo measurements of contact areas with 3D open magnetic resonance imaging (MRI), and to study knee joint contact areas in patients with patellar subluxation at different angles of knee flexion in comparison with healthy subjects. METHODS: 3D-MRI data sets of 12 healthy volunteers and eight patients with patellar subluxation were acquired using a standard clinical (1.5 T) and an open (0.2 T) MRI scanner. We compared femoro-patellar and femoro-tibial contact areas obtained with two different sequences from open MRI [dual-echo-steady-state (DESS) and fast-low-angle-shot (FLASH) sequences] with those derived from standard clinical 1.5 T MRI. We then analyzed differences in joint contact areas between healthy subjects and patients with patellar subluxation at 0 degree, 30 degrees, and 90 degrees of knee flexion using open MRI. RESULTS: The correlation of the size of contact areas from open MRI with standard clinical MRI data ranged from r = 0.52 to 0.92. Open-MRI DESS displayed a smaller overestimation of joint contact areas (+21% in the femoro-patellar, +12% in the medial femoro-tibial, and +19% in the lateral femoro-tibial compartment) than FLASH (+40%, +37%, +30%, respectively). The femoro-patellar contact areas in patients were significantly reduced in comparison with healthy subjects (-47% at 0 degree, -56% at 30 degrees, and -42% at 90 degrees of flexion; all p < 0.01), whereas no significant difference was observed in femoro-tibial contact areas. CONCLUSIONS: Open MRI allows one to quantify joint contact areas of the knee with reasonable accuracy, if an adequate pulse sequence is applied. The technique permits one to clearly identify differences between patients with patellar subluxation and healthy subjects at different flexion angles, demonstrating a significant reduction and lateralization of contact areas in patients. In the future, application of this in vivo technique is of particular interest for monitoring the efficacy of different types of surgical and conservative treatment options for patellar subluxation.  相似文献   

8.
Analysis of polyethylene component wear and implant loosening in total knee arthroplasty (TKA) requires precise knowledge of in vivo articular motion and loading conditions. This study presents a simultaneous in vivo measurement of tibiofemoral articular contact forces and contact kinematics in three TKA patients. These measurements were accomplished via a dual fluoroscopic imaging system and instrumented tibial implants, during dynamic single leg lunge and chair rising-sitting. The measured forces and contact locations were also used to determine mediolateral distribution of axial contact forces. Contact kinematics data showed a medial pivot during flexion of the knee, for all patients in the study. Average axial forces were higher for lunge compared to chair rising-sitting (224% vs. 187% body weight). In this study, we measured peak anteroposterior and mediolateral forces averaging 13.3% BW during lunge and 18.5% BW during chair rising-sitting. Mediolateral distributions of axial contact force were both patient and activity specific. All patients showed equitable medial-lateral loading during lunge but greater loads at the lateral compartment during chair rising-sitting. The results of this study may enable more accurate reproduction of in vivo loads and articular motion patterns in wear simulators and finite element models. This in turn may help advance our understanding of factors limiting longevity of TKA implants, such as aseptic loosening and polyethylene component wear, and enable improved TKA designs.  相似文献   

9.
Fuji film has been widely used in studies aimed at obtaining the contact mechanics of articular joints. Once sealed for practical use in biological joints, Fuji Pressensor film has a total effective thickness of 0.30 mm, which is comparable to the cartilage thickness in the joints of many small animals. The average effective elastic modulus of Fuji film is approximately 100 MPa in compression, which is larger by a factor of 100-300 compared to that of normal articular cartilage. Therefore, inserting a Pressensor film into an articular joint will change the contact mechanics of the joint. The measurement precision of the Pressensor film has been determined systematically; however, the changes in contact mechanics associated with inserting the film into joints have not been investigated. This study was aimed at quantifying the changes in the contact mechanics associated with inserting sealed Fuji Pressensor film into joints. Spherical and cylindrical articular joint contact mechanics with and without Pressensor film and for varying degrees of surface congruency were analyzed and compared by using finite element models. The Pressensor film was taken as linearly elastic and the cartilage was assumed to be biphasic, composed of a linear elastic solid phase and an inviscid fluid phase. The present analyses showed that measurements of the joint contact pressures with Fuji Pressensor film will change the maximum true contact pressures by 10-26 percent depending on the loading, geometry of the joints, and the mechanical properties of cartilage. Considering this effect plus the measurement precision of the film (approximately 10 percent), the measured joint contact pressures in a joint may contain errors as large as 14-28 percent.  相似文献   

10.
The load-bearing area in the knee joint   总被引:7,自引:0,他引:7  
Measurements were made of the location and size of the contact areas in cadaver knee joints, for a load of 150 Kgf applied for 5 sec down the long axis of the tibia. Results were obtained from a total of 4 knees, considering flexion angles from 0 to 120°. The methods used were to measure directly from castings of the joint cavity; and to calculate from measurements of radii of curvature and joint deflection. Average contact areas for lateral and medial condyles were 1·4 and 1·8 cm2 respectively. Areas for the medial condyle were greater than for the lateral condyle and also the areas diminished as flexion angle increased. The implications of the results to contact stresses, joint lubrication and ‘condylar replacement’ knee prosthesis design were discussed.  相似文献   

11.
Overweight and obese children demonstrate inferior motor performance for strength- and power-related activities requiring support or lifting of body weight. Our purpose here was to determine whether the inferior performance could be attributed to a lower strength to muscle area ratio in the obese. Eleven nonobese (16.6% fat) and 13 obese (35.5% fat) boys (9-13 years old) volunteered for the study. Peak torque was measured during voluntary isometric and isokinetic elbow flexion and knee extension at four joint angles and four velocities, respectively. The contractile properties, twitch torque, time to peak torque, and half-relaxation time were evoked for the elbow flexors by percutaneous stimulation. Elbow flexor and knee extensor cross-sectional areas (CSA) were determined by computed axial tomography taken at the mid-upper arm and mid-thigh, respectively. Isometric and isokinetic elbow flexion and knee extension strength normalized for body weight were significantly (p less than 0.05) higher in the nonobese compared to the obese boys. There were no significant (p greater than 0.05) differences, however, between groups for elbow flexor and knee extensor CSA or for absolute and relative (normalized for muscle CSA or the product of muscle CSA and height, the latter accounting for differences in moment arm length) isometric, isokinetic, or evoked twitch torque for elbow flexion or knee extension. Likewise, there were no differences between groups for the time-related contractile properties, time to peak torque, or half-relaxation time. These findings suggest that there is no difference in the intrinsic strength or contractile properties of the elbow flexor and knee extensor muscles between obese and nonobese pre-adolescent boys and that other factors, such as the handicapping effect of excess fat mass, probably account for the reduced motor performance of the obese child.  相似文献   

12.
In order to assess the changes in talocrural joint contact stress after rotationplasty, 10 lower-leg cadaver specimens were axially loaded with 600 N and investigated in two loading situations: (1) Normal loading with a plantigrade foot; (2) in an equinus position of a simulated rotationplasty. Joint contact stress in the talar facet of the talocrural joint was determined with Fuji Prescale film cut to size and analyzed with digital image analysis for joint contact area, mean and peak pressure, contact force, and location of the load application on the trochlea tali. The results demonstrate a significant transfer on the loading zone to the posterior part of the talus (p = 0.005), a significant reduction of the contact area (p = 0.005) and force (p = 0.005), and a significant increase of the mean (p = 0.022) and maximum pressures (p = 0.013). These results indicate that the rotationplasty causes pronounced changes in joint loading characteristics.  相似文献   

13.
The influence of parachute-resisted sprinting on running mechanics in collegiate track athletes. The aim of this investigation was to compare the acute effects of parachute-resisted (PR) sprinting on selected kinematic variables. Twelve collegiate sprinters (mean age 19.58 ± 1.44 years, mass 69.32 ± 14.38 kg, height 1.71 ± 9.86 m) ran a 40-yd dash under 2 conditions: PR sprint and sprint without a parachute (NC) that were recorded on a video computer system (60 Hz). Sagittal plane kinematics of the right side of the body was digitized to calculate joint angles at initial ground contact (IGC) and end ground contact (EGC), ground contact (GC) time, stride rate (SR), stride length (SL), and the times of the 40-yd dashes. The NC 40-yd dash time was significantly faster than the PR trial (p < 0.05). The shoulder angle at EGC significantly increased from 34.10 to 42.10° during the PR trial (p < 0.05). There were no significant differences in GC time, SR, SL, or the other joint angles between the 2 trials (p > 0.05). This study suggests that PR sprinting does not acutely affect GC time, SR, SL and upper extremity or lower extremity joint angles during weight acceptance (IGC) in collegiate sprinters. However, PR sprinting increased shoulder flexion by 23.5% at push-off and decreased speed by 4.4%. While sprinting with the parachute, the athlete's movement patterns resembled their mechanics during the unloaded condition. This indicates the external load caused by PR did not substantially overload the runner, and only caused a minor change in the shoulder during push-off. This sports-specific training apparatus may provide coaches with another method for training athletes in a sports-specific manner without causing acute changes to running mechanics.  相似文献   

14.
The purpose of this study was to assess kinematic lower extremity motion patterns (hip flexion, knee flexion, knee valgus, and ankle dorsiflexion) during various foot-landing techniques (self-preferred, forefoot, and rear foot) between genders. 3-D kinematics were collected on 50 (25 male and 25 female) college-age recreational athletes selected from a sample of convenience. Separate repeated-measures ANOVAs were used to analyze each variable at three time instants (initial contact, peak vertical ground reaction force, and maximum knee flexion angle). There were no significant differences found between genders at the three instants for each variable. At initial contact, the forefoot technique (35.79 degrees +/- 11.78 degrees ) resulted in significantly (p = .001) less hip flexion than did the self-preferred (41.25 degrees +/- 12.89 degrees ) and rear foot (43.15 degrees +/- 11.77 degrees ) techniques. At peak vertical ground reaction force, the rear foot technique (26.77 degrees +/- 9.49 degrees ) presented significantly lower (p = .001) knee flexion angles as compared with forefoot (58.77 degrees +/- 20.00 degrees ) and self-preferred (54.21 degrees +/- 23.78 degrees ) techniques. A significant difference for knee valgus angles (p = .001) was also found between landing techniques at peak vertical ground reaction force. The self-preferred (4.12 degrees +/- 7.51 degrees ) and forefoot (4.97 degrees +/- 7.90 degrees ) techniques presented greater knee varus angles as compared with the rear foot technique (0.08 degrees +/- 6.52 degrees ). The rear foot technique created more ankle dorsiflexion and less knee flexion than did the other techniques. The lack of gender differences can mean that lower extremity injuries (e.g., ACL tears) may not be related solely to gender but may instead be associated with the landing technique used and, consequently, the way each individual absorbs jump-landing energy.  相似文献   

15.
Newer designs of total knee arthroplasty (TKA), through the use of added degrees of constraint, attempt to provide a "guided motion" to restore more normal and predictable kinematics. Two such design philosophies are the posterior stabilised (PS) using a cam-post and the medial pivot (MP) concepts. Knee kinematics of 12 patients with a PS TKA, 13 subjects with a MP TKA and 10 normal subjects were compared. For kinematic assessment, patients underwent fluoroscopic assessment of the knee during a step-up exercise and deep knee bend. Fluoroscopic images were corrected for distortion and assessed using 3D model fitting to determine relative 3D motion, and a 2D method to measure the patellar tendon angle (PTA) as function of knee flexion. For the PS design the cam-post mechanism engaged between 70 degrees and 100 degrees flexion. Between extension and 50 degrees there was forward motion of the contact points. Beyond 60 degrees both condyles rolled moved posteriorly. The majority of the external rotation of the femur occurred between 50 degrees and 80 degrees . The PTA was lower than normal in extension and higher than normal in flexion. The MP exhibited no anterior movement throughout the rage of motion. The medial condyle moved minimally. The lateral contact point moved posteriorly from extension to flexion. The femur rotated externally throughout the range of flexion analysed. The PTA was similar to normal from extension to mid flexion and then higher than normal beyond to high flexion. The PS design fails to fully restrain paradoxical anterior movement and although the cam engages, it does not contribute significantly to overall rollback. The MP knee does not show significant anterior movement, the medial pivot concept appears to achieve near normal kinematics from extension to 50 degrees of knee flexion. However, the results show that at high flexion this design does not achieve normal knee kinematics.  相似文献   

16.
Tibio-femoral joint contact forces in sheep   总被引:1,自引:0,他引:1  
Although the sheep has become a standard model for understanding the mechanical conditions that occur after injury and investigating surgical treatments such as osteochondral defect healing and ligament reconstruction, no study has yet evaluated the contact forces that occur in the sheep tibio-femoral joint in vivo. In this study, bone pins, together with reflective markers, were used to measure the 3D kinematics of three sheep hind limbs, simultaneously with the ground reaction forces during repetitions of gait trials. Joint contact forces were then calculated using inverse dynamics and optimisation techniques. Whilst average peak axial tibio-femoral contact forces of 2.1 body weight (BW) were calculated across the 3 sheep, only small medio-lateral and antero-posterior shear forces, averaging 0.7 BW, were determined. Average knee flexion angles ranging from 49 degrees to 70 degrees were observed. From the forces determined in this study, we have provided a better understanding of the mechanical loading environment that occurs in sheep. This has important implications for the interpretation of knee studies in quadrupeds and their relevance to the clinical situation.  相似文献   

17.
In high knee flexion, contact between the posterior thigh and calf is expected to decrease forces on tibiofemoral contact surfaces, therefore, thigh-calf contact needs to be thoroughly characterized to model its effect. This study measured knee angles and intersegmental contact parameters in fifty-eight young healthy participants for six common high flexion postures using motion tracking and a pressure sensor attached to the right thigh. Additionally, we introduced and assessed the reliability of a method for reducing noise in pressure sensor output. Five repetitions of two squatting, two kneeling, and two unilateral kneeling movements were completed. Interactions of posture by sex occurred for thigh-calf and heel-gluteal center of force, and thigh-calf contact area. Center of force in thigh-calf regions was farther from the knee joint center in females, compared to males, during unilateral kneeling (82 and 67 mm respectively) with an inverted relationship in the heel-gluteal region (331 and 345 mm respectively), although caution is advised when generalizing these findings from a young, relatively fit sample to a population level. Contact area was larger in females when compared to males (mean of 155.61 and 137.33 cm2 across postures). A posture main effect was observed in contact force and sex main effects were present in onset and max angle. Males had earlier onset (121.0°) and lower max angle (147.4°) with onset and max angles having a range between movements of 8° and 3° respectively. There was a substantial total force difference of 139 N between the largest and smallest activity means. Force parameters measured in this study suggest that knee joint contact models need to incorporate activity-specific parameters when estimating loading.  相似文献   

18.
A method for gait analysis using wearable acceleration sensors and gyro sensors is proposed in this work. The volunteers wore sensor units that included a tri-axis acceleration sensor and three single axis gyro sensors. The angular velocity data measured by the gyro sensors were used to estimate the translational acceleration in the gait analysis. The translational acceleration was then subtracted from the acceleration sensor measurements to obtain the gravitational acceleration, giving the orientation of the lower limb segments. Segment orientation along with body measurements were used to obtain the positions of hip, knee, and ankle joints to create stick figure models of the volunteers. This method can measure the three-dimensional positions of joint centers of the hip, knee, and ankle during movement. Experiments were carried out on the normal gait of three healthy volunteers. As a result, the flexion–extension (F–E) and the adduction–abduction (A–A) joint angles of the hips and the flexion–extension (F–E) joint angles of the knees were calculated and compared with a camera motion capture system. The correlation coefficients were above 0.88 for the hip F–E, higher than 0.72 for the hip A–A, better than 0.92 for the knee F–E. A moving stick figure model of each volunteer was created to visually confirm the walking posture. Further, the knee and ankle joint trajectories in the horizontal plane showed that the left and right legs were bilaterally symmetric.  相似文献   

19.
Osteonecrosis of the femoral head remains a challenging orthopaedic problem. The disease frequently progresses to femoral head collapse, leading to debilitating osteoarthritis in the affected hip(s). Since a major goal of pre-collapse interventions is to forestall the need for hip arthroplasty, it is important that any animal models used to develop or study such interventions also have a natural history of progression to femoral head collapse. The emu (Dromaius novaehollandiae), a large flightless bird native to Australia, consistently progresses to femoral head collapse when osteonecrosis is experimentally induced cryogenically. Full biomechanical characterization of the demands this animal places on its hip is an important consideration in future usage of this model. This study reports in vitro measurement of the contact stress distributions on the emu femoral head during stance phase of the gait cycle, using Fuji pressure-sensitive film. Applied hip loadings were based upon ground reaction forces and hip flexion angles recorded in vivo. The contact stress data showed reasonable homology with the human hip, both in terms of stress magnitude and sites of habitual loading on the femoral head.  相似文献   

20.

Background

Transection of the canine cranial cruciate ligament (CCL) is a well-established osteoarthritis (OA) model. The effect of CCL loss on contact pressure and joint alignment has not been quantified for stifle loading in standing. The purposes of the study were to measure femorotibial contact areas and stresses and joint alignment following transection of the CCL in an ex vivo model. We hypothesized that transection of the CCL would lead to abnormal kinematics, as well as alterations in contact mechanics of the femorotibial joint.

Methodology/Principal Findings

Eight canine hindlimbs were tested in a servo-hydraulic materials testing machine using a custom made femoral jig. Contact area and pressure measurements, and femorotibial rotations and translations were measured in the normal and the CCL–deficient stifle in both standing and deep flexion angles.We found that at standing angle, transection of the CCL caused cranial translation and internal rotation of the tibia with a concurrent caudal shift of the contact area, an increase in peak pressure and a decrease in contact area. These changes were not noted in deep flexion. At standing, loss of CCL caused a redistribution of the joint pressure, with the caudal region of the compartment being overloaded and the rest of the joint being underloaded.

Conclusion

In the Pond-Nuki model alterations in joint alignment are correlated with shifting of the contact points to infrequently loaded areas of the tibial plateau. The results of this study suggest that this cadaveric Pond-Nuki model simulates the biomechanical changes previously reported in the in-vivo Pond-Nuki model.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号