首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A sensitive high-performance liquid chromatographic assay has been developed to determine the levels of 3'-amino-3'-deoxy-thymidine (AMT), a cytotoxic metabolite of 3'-azido-3'-deoxy-thymidine (AZT, zidovudine), in human plasma. The sample pretreatment involved solid-phase extraction using cation-exchange extraction columns. Chromatography was carried out on a C8 column, using a mobile phase of methanol—0.01 M ammonium acetate (pH 5)—0.25 M sodium dioctylsulfosuccinate (60:40:4, v/v/v) and ultraviolet detection at 265 nm. The method has been validated, and stability tests under various conditions have been performed. The lower limit of quantitation is 5 ng/ml (using 500-μl human plasma samples). The bioanalytical assay has been used for the determination of AMT in patients with AIDS who used AZT.  相似文献   

2.
All-E-(3R,6′R)-3-hydroxy-3′,4′-didehydro-β,γ-carotene (anhydrolutein I) and all-E-(3R,6′R)-3-hydroxy-2′,3′-didehydro-β,ε-carotene (2′,3′-anhydrolutein II) have been isolated and characterized from extracts of human plasma using semipreparative high-performance liquid chromatography (HPLC) on a C18 reversed-phase column. The identification of anhydroluteins was accomplished by comparison of the UV-Vis absorption and mass spectral data as well as HPLC-UV-Vis-mass spectrometry (MS) spiking experiments using fully characterized synthetic compounds. Partial synthesis of anhydroluteins from the reaction of lutein with 2% H2SO4 in acetone, in addition to anhydrolutein I (54%) and 2′,3′-anhydrolutein II (19%), also gave (3′R)-3′-hydroxy-3,4-dehydro-β-carotene (3′,4′-anhydrolutein III, 19%). While anhydrolutein I has been shown to be usually accompanied by minute quantities of 2′,3′-anhydrolutein II (ca. 7–10%) in human plasma, 3′,4′-anhydrolutein III has not been detected. The presence of anhydrolutein I and II in human plasma is postulated to be due to acid catalyzed dehydration of the dietary lutein as it passes through the stomach. These anhydroluteins have also been prepared by conversion of lutein diacetate to the corresponding anhydrolutein acetates followed by alkaline hydrolysis. However, under identical acidic conditions, loss of acetic acid from lutein diacetate proceeded at a much slower rate than dehydration of lutein. The structures of the synthetic anhydroluteins, including their absolute configuration at C(3) and C(6′) have been unambiguously established by 1H NMR and in part by 13C NMR, and circular dichroism.  相似文献   

3.
A specific and reproducible HPLC method using a Chiral-AGP column and UV detection was developed for the evaluation of the pharmacokinetic profile of oxodipine enantiomers in dog and man. Each enantiomer was determined in plasma in the concentration range 1–400 ng/ml using the internal standard calibration method with linear regression analysis. After extraction of oxodipine and the internal standard at alkaline pH with diethyl ether—n-hexane (50:50, v/v), this method permitted the determination of each enantiomer at levels down to 10 ng/ml in dog plasma and 25 ng/ml in human plasma with sufficient accuracy (relative error <11%, n = 6) and precision (coefficient of variation <16%, n = 6). The extracted plasma volume was 500 μl and after evaporation of the organic phase, the dry residue was dissolved in 100 μl of water—2-propanol; an aliquot of 80 μl was injected into the HPLC system.  相似文献   

4.
A column-switching, reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of a new carbapenem antibiotic assay using ultraviolet detection has been developed for a new carbapenem antibiotic L-749,345 in human plasma and urine. A plasma sample is centrifuged and then injected onto an extraction column using 25 mM phosphate buffer, pH 6.5. After 3 min, using a column-switching valve, the analyte is back-flushed with 10.5% methanol–phosphate buffer for 3 min onto a Hypersil 5 μm C18 BDS 100×4.6 mm analytical column and then detected by absorbance at 300 nm. The sample preparation and HPLC conditions for the urine assay are similar, except for a longer analytical column 150×4.6 mm. The plasma assay is specific and linear from 0.125 to 50 μg/ml; the urine assay is linear from 1.25 to 100 μg/ml.  相似文献   

5.
A method is described for the determination of pyronaridine in plasma using high-performance liquid chromatography with fluorescence detection. The method involves liquid-liquid extraction with phosphate buffer (pH 6.0, 0.05 M) and diethyl ether-hexane (70:30%, v/v) and chromatographic separation on a C18 column (Nucleosil, 250 × 4.6 mm I.D., 5 μm particle size) with acetonitrile-0.05 M phosphate buffer pH 6.0 (60:40%, v/v) as the mobile phase (1 ml/min) and detection by fluorescence (λex = 267 nm, λem = 443 nm). The detector response is linear up to 1000 ng and the overall recoveries pyronaridine and quinine were 90.0 and 60.3%, respectively. The assay procedure was adequately sensitive to measure 10 ng/ml pyronaridine in plasma samples with acceptable precision (< 15% C.V.). The method was found to be suitable for use in clinical pharmacological studies.  相似文献   

6.
A sensitive high-performance liquid chromatographic method is described for the quantification of midazolam and 1′-hydroxymidazolam in human plasma. Sample (1 ml plasma) preparation involved a simple solvent extraction step with a recovery of approximately 90% for both compounds. An aliquot of the dissolved residue was injected onto a 3 μm capillary C18 column (150 mm×0.8 mm I.D.). A gradient elution was used. The initial mobile phase composition (phosphate buffer–acetonitrile, 65:35) was maintained during 16 min and was then changed linearly during a 1-min period to phosphate buffer–acetonitrile, 40:60. The flow-rate of the mobile phase was 16 μl/min and the eluate was monitored by UV detection. The limits of quantification for midazolam and 1′-hydroxymidazolam were 1 ng/ml and 0.5 ng/ml, respectively. The applicability of the method was demonstrated by studying the pharmacokinetics of midazolam, and its major metabolite 1′-hydroxymidazolam, in human volunteers following i.v. bolus administration of a subtherapeutic midazolam dose (40 μg/kg).  相似文献   

7.
A sensitive assay was developed for the quantitation of 5-fluorouracil (5-FU) and uracil using liquid–liquid extraction (LLE) and HPLC with UV detection. Analyses were performed with four μBondapak C18 columns connected in series using 20 mM acetic acid with 1% ACN as mobile phase. The calibration curves were linear across the range of 26–1000 ng ml−1 (0.21–7.8 μM) for 5-FU and 1.0–14.0 μg ml−1 (0.01–110 μM) for uracil. This assay has been implemented to determine the plasma concentrations for pharmacokinetic studies for 5-FU and uracil in conjunction with clinical trials.  相似文献   

8.
From the dichloromethane extract of the flowers of Helichrysum gymnocomum (Asteraceae) two known flavonoids, 4 and 5, and a known acylphloroglucinol, 3B, were isolated. In addition to 1 and 2, the 4′,6′-dibenzyloxy-2′-hydroxy derivative of 2′,4′,6′-trihydroxychalcone and 5,7-dibenzyloxy derivative of pinocembrin, respectively, are reported in Nature for the first time. A compound 3A, related to 3B has the structure 2-methyl-1-[2,4,6-trihydroxy-3-(2-hydroxy-3-methyl-3-butenyl)phenyl]-1-propanone. Compounds 1, 2, 3A, 3B, 4 and 5 have MIC values below 64 μg/ml against a selection of pathogens, with 3B having the highest sensitivity (6.3–45 μg/ml) for eight of the ten pathogens tested, including Staphylococcus aureus (6.3 μg/ml) and methicillin and gentamycin resistant strain of S. aureus (7.8 μg/ml). With the exception of 2, the other compounds had notable activity (45–63 μg/ml) towards Pseudomonas aeruginosa.  相似文献   

9.
A stereoselective high-performance liquid chromatographic (HPLC) method is described for the selective and sensitive quantitation in human plasma of R-(+)- and S-(−)-enantiomers of remoxipride. Remoxipride was extracted from basified plasma into hexane-methyl-tert.-butyl ether (20:80, v/v), washed with sodium hydroxide (1.0 M), then back-extracted into phosphoric acid (0.1 M). A structural analog of remoxipride was used as an internal standard. The sample extracts were chromatographed using a silica-based derivatized cellulose chiral column, Chiralcel OD-R, and a reversed-phase eluent containing 30–32% acetonitrile in 0.1 M potassium hexafluorophosphate. Ultraviolet (UV) absorbance detection was performed at 214 nm. Using 0.5-ml plasma aliquots, the method was validated in the concentration range 0.02-2.0 μg/ml and was applied in the investigation of systemic inversion of remoxipride enantiomers in man.  相似文献   

10.
A reversed-phase high-performance liquid chromatographic method has been developed and validated for the quantification of the novel anticancer drug Ecteinascidin 743 in human plasma. The sample pretreatment of the plasma samples involved a solid-phase extraction (SPE) on cyano columns. Propyl-p-hydroxybenzoate was added after the sample pretreatment to correct for variability in injection volumes. The separation was performed on a Zorbax SB-C18 column (75×4.6 mm I.D., particle size 3.5 μm) with acetonitrile–25 mM phosphate buffer, pH 5.0 (70:30, v/v) as the mobile phase. The flow-rate was 1.0 ml/min and the eluent was monitored at 210 nm. The accuracies and precisions of the assay fall within ±15% for all quality control samples and within ±20% for the lower limit of quantitation, which was 1.0 ng/ml using 500 μl of plasma. The overall recovery of the sample pretreatment procedure for Ecteinascidin 743 was 87.0±5.9%. The drug was found to be stable in human plasma at −30°C for at least 2 months. At room temperature Ecteinascidin 743 was stable in human plasma for 5 h at most.  相似文献   

11.
A gas chromatographic–electron capture detection (GC–ECD) method has been developed for determining Guan-Fu Base A (GFA), an experimental anti-arrhythmic, in human plasma. The method was based on one-step liquid–liquid extraction with toluene and chemical derivatization with pentafluoropropionic anhydride followed by GC–ECD. The derivatives of GFA and metoprolol (Met, internal standard) were confirmed by gas chromatography–mass spectrometry (GC–MS) to be dipentafluoropropionyl-GFA and dipentafluoropropionyl-Met. The method was linear over the concentration ranges of 0.1–20.0 and 1.0–30.0 μg/ml with the detection limit of 0.05 μg/ml at S/N=5. The intra- and inter-assay precisions were less than 6 and 10%, and accuracy 99.70±3.30 and 97.60±5.99%, respectively. The absolute recoveries were 81.88, 77.35, 80.79 and 83.85% for GFA at concentrations of 0.5, 1.0, 5.0 and 14.0 μg/ml and 88.24% for Met at 3.0 μg/ml, respectively.  相似文献   

12.
A solid-phase extraction (SPE) procedure was developed for the quantification of nalbuphine in a small volume (500 μl) of human plasma with subsequent assay by high-performance liquid chromatography (HPLC) and electrochemical detection using 6-monoacetylmorphine as internal standard. Plasma was extracted using Bond Elute certified extraction columns (LCR: 10 ml, 130 mg) after conditioning with methanol and 0.2 M Tris buffer (pH 8). Elution was performed with a CH2Cl2-isopropanol-NH4OH (79:20:, v/v). The organic phase was evaporated to dryness and resuspended in HPLC mobile phase containing 2% isopropanol. Linearity was assessed over the 5–100 ng/ml concentration range and a straight line passing through the origin was obtained. Experiments with spiked plasma samples resulted in recoveries of 95±5.4% and 98±6.2% for nalbuphine and 6-monoacetylmorphine, respectively. The optimal pH conditions for the SPE were found at pH 8. The intra-day coefficients of variation (C.V.) for 5, 40, and 100 ng/ml were 5.3, 3.0 and 2.3% (n=8) and the inter-day C.V.s were 7.7, 3.2 and 3.5% (n=10), respectively. The detection limit for 500 μl plasma sample was 0.02 ng/ml and the limit of quantification 0.1 ng/ml (C.V.=12.4%). The ease of the proposed method of analysis, as well as its high accuracy and sensitivity allow its application to pharmacokinetic studies. A preliminary kinetic profile of nalbuphine after rectal administration in a pediatric patient is presented.  相似文献   

13.
Amphotericin B is a potent polyene antifungal drug for intravenous treatment of severe infections. It is used as amphotericin B-deoxycholate and in order to reduce amphotericin B toxicity as lipid-formulated complex (liposomal or colloidal dispersion). A sensitive and specific analytical method is presented for the separation of lipid-complexed and plasma protein-bound amphotericin B in human heparinized plasma. This separation, which is required for pharmacokinetic studies, is achieved by solid-phase extraction (SPE) via Bond Elut C18. The protein-bound amphotericin B has a higher affinity to the SPE material and is therefore retained, whereas the lipid-complexed amphotericin B is eluted in the first step. The recovery of the SPE was >75% for high concentrations and >95% for low concentrations. Quantification was performed by reversed-phase HPLC using a LiChrosorb-RP-8 column, UV detection (λ=405 nm) and a mixture of acetonitrile–methanol–0.010 M NaH2PO4 buffer (41:10:49, v/v) as mobile phase. The retention time for amphotericin B under the given conditions was 6.7 min. The calibration curves were found to be linear (r≥0.999) in two different ranges (5.0–0.50 μg/ml and 0.50–0.005 μg/ml). Intra- and inter-day precision and accuracy fulfilled the international requirements. No interference from other drugs (typical broad medication for intensive-care patients) or common plasma components was detected in >400 samples analyzed.  相似文献   

14.
15.
A rapid, selective, sensitive and reproducible HPLC with recutive electrochemical detection for quantitatvie determination of artemether (ART) and its plasma metabolite, dihydroartemisinin (DHA: and β isomers) in plasma is described. The procedure involved the extraction of ART, DHA and the internal standard, artemisinin (ARN) with dichloromethane-tert.-methylbutyl ether (1:1, v/v) or n-butyl chloride-ethyl acetate (9:1, v/v). Chromatographic separation was performed with a mobile phase of acetonitrile-water (20:80, v/v) containing 0.1 M acetic acid pH 5.0, running through a μBondapak CN column. The method was capable of separating the two isomeric forms of DHA (, β). The retention times of -DHA, β-DHA, ARN and ART were 4.6, 5.9, 7.9 and 9.6 min, respectively. Validation of the assay method was performed using both extraction systems. The two extraction systems produced comparable recoveries of the various analytes. The average recoveries of ART, DHA and ARN over the concentration range 80–640 ng/ml were 86–93%. The coefficients of variation were below 10% for all three drugs (ART, -DHA, ARN). The minimum detectable concentrations for ART and -DHA in spiked plasma samples were 5 and 3 ng/ml, respectively. The method was found to be suitable for use in clinical pharmacokinetic study.  相似文献   

16.
A high-performance liquid chromatographic method was developed for the determination of a chemoprotective agent, 2-(allylthio)pyrazine (I), in human plasma and urine, and in rat blood and tissue homogenate using diazepam as an internal standard. The sample preparation was simple; 2.5 volumes of acetonitrile were added to the biological sample to deproteinize it. A 50–100 μl aliquot of the supernatant was injected onto a C18 reversed-phase column. The mobile phase employed was acetonitrile–water (55:45, v/v), and it was run at a flow-rate of 1.5 ml/min. The column effluent was monitored using an ultraviolet detector at 330 nm. The retention times for I and the internal standard were 4.0 and 5.1 min, respectively. The detection limits of I in human plasma and urine, and in rat tissue homogenate (including blood) were 20, 20 and 50 ng/ml, respectively. The coefficients of variation of the assay (within-day and between-day) were generally low (below 6.1%) in a concentration range from 0.02 to 10 μg/ml for human plasma and urine, and for rat tissue homogenate. No interferences from endogenous substances were found.  相似文献   

17.
A highly sensitivity liquid chromatography–tandem mass spectrometry method has been developed for the quantitation of sodium cromoglycate (SCG) in human plasma. The method was validated over a linear range of 0.100–50.0 ng/ml, using 13C4 sodium cromoglycate as the internal standard. Compounds were extracted from 1.0 ml of lithium heparin plasma by methanol elution of C18 solid-phase extraction cartridges. The dried residue was reconstituted with 100 μl of 0.01 N HCl, and 30 μl was injected onto the LC–MS–MS system. Chromatographic separation was achieved on a C8 (3.5 μm) column with an isocratic mobile phase of methanol–water–0.5 M ammonium acetate (35:64.8:0.2, v/v/v). The analytes were detected with a PE Sciex API 3000 mass spectrometer using turbo ion spray with positive ionization. Ions monitored in the multiple reaction monitoring (MRM) mode were m/z 469.2 (precursor ion) to m/z 245.1 (product ion) for SCG and m/z 473.2 (precursor ion) to m/z 247.1 (product ion) for 13C4 SCG (I.S.). The average recoveries of SCG and the I.S. from human plasma were 91 and 87%, respectively. The low limit of quantitation was 0.100 ng/ml. Results from a 4-day validation study demonstrated excellent precision (C.V.% values were between 1.9 and 6.5%) and accuracy (−5.4 to −1.2%) across the calibration range of 0.100–50.0 ng/ml.  相似文献   

18.
Sensitive high-performance liquid chromatographic assays have been developed for the quantification of stavudine (2′,3′-didehydro-3′-deoxythymidine, d4T) in human plasma and urine. The methods are linear over the concentration ranges 0.025–25 and 2–150 μg/ml in plasma and urine, respectively. An aliquot of 200 μl of plasma was extracted with solid-phase extraction using Oasis® cartridges, while urine samples were simply diluted 1/100 with HPLC water. The analytical column, mobile phase, instrumentation and chromatographic conditions are the same for both methods. The methods have been validated separately, and stability tests under various conditions have been performed. The detection limit is 12 ng/ml in plasma for a sample size of 200 μl. The bioanalytical assay has been used in a pharmacokinetic study of pregnant women and their newborns.  相似文献   

19.
An HPLC assay for DMP 811, 4-ethyl-2-propyl-1-[(2′-(1H-tetrazol-5-yl)biphenyl-4-yl)-methyl]imidazole-5-carboxylic acid (I) in rat and dog plasma has been developed. Compound I was isolated from plasma using a liquid—liquid back extraction procedure. The extraction recovery was greater than 81%. Separation of I from endogenous components in plasma was achieved on an E. Merck C8 column using a mobile phase of 0.05 M ammonium acetate, brought to pH 3.75 with acetic acid, and acetonitrile (78:22, v/v). The eluent was monitored by fluorescence with excitation and emission set at 235 and 370 nm, respectively. The assay was linear from 2 to 2000 ng/ml. Inter- and intra-day coefficients of variation for the rat-plasma assay ranged from 0.9 to 5.2% (5–2000 ng/ml) and 2.7 to 16.5% (2–2000 ng/ml), respectively. The respective coefficients of variation for the dog-plasma assay were 1.9 to 5.6% and 1.2 to 14.0%. The percent differences from the accuracy results were 12% or less. Using 0.5 ml of plasma for extraction, the minimum quantifiable limit was 2 ng/ml. This method has been used to quantify plasma levels of I in rats or dogs following 3–10 mg/kg i.v. or p.o. doses.  相似文献   

20.
Mycobacterium tuberculosis and Mycobacterium avium infections cause the two most important mycobacterioses, leading to increased mortality in patients with AIDS. Various 5-substituted 2′-deoxyuridines, uridines, 2′-O-methyluridine, 2′-ribofluoro-2′-deoxyuridines, 3′-substituted-2′,3′-dideoxy uridines, 2′,3′-dideoxyuridines, and 2′,3′-didehydro-2′,3′-dideoxyuridines were synthesized and evaluated for their in vitro inhibitory activity against M. bovis and M. avium. 5-(C-1 Substituted)-2′-deoxyuridine derivatives emerged as potent inhibitors of M. avium (MIC90 = 1–5 μg/mL range). The nature of C-5 substituents in the 2′-deoxyuridine series appeared to be a determinant of anti-mycobacterial activity. This new class of inhibitors could serve as useful compounds for the design and study of new anti-tuberculosis agents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号